Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Life (Basel) ; 13(3)2023 Mar 15.
Article in English | MEDLINE | ID: mdl-36983949

ABSTRACT

Primary mucosal melanoma (PMM) and pancreatic ductal adenocarcinoma (PDAC) are two aggressive malignancies, characterized by intrinsic radio-chemoresistance and neurotropism, a histological feature resulting in frequent perineural invasion (PNI), supported by neurotrophic factors secreted in the tumour microenvironment (TME), such as neurotrophin-3 (NT-3). Carbon-ion radiotherapy (CIRT) could represent an effective option in unresectable PMM and PDAC. Only a few data about the effects of CIRT on PNI in relation to NT-3 are available in the literature, despite the numerous pieces of evidence revealing the peculiar effects of this type of radiation on tumour cell migration. This in vitro study investigated for the first time the response of PMM and PDAC cells to NT-3 and evaluated the effects of conventional photon beam radiotherapy (XRT) and CIRT on cell viability, proliferation, and migration. Our results demonstrated the greater capacity of C-ions to generally decrease cell viability, proliferation, and migration, while the addition of NT-3 after both types of irradiation determined an increase in these features, maintaining a dose-dependent trend and acting more effectively as a chemoattractant than inductor in the case of migration.

2.
Int J Mol Sci ; 24(3)2023 Feb 03.
Article in English | MEDLINE | ID: mdl-36769302

ABSTRACT

Colorectal cancer (CRC) is the most prominent form of colon cancer for both incidence (38.7 per 100,000 people) and mortality (13.9 per 100,000 people). CRC's poor response to standard therapies is linked to its high heterogeneity and complex genetic background. Dysregulation or depletion of the tumor suppressor p53 is involved in CRC transformation and its capability to escape therapy, with p53null cancer subtypes known, in fact, to have a poor prognosis. In such a context, new therapeutic approaches aimed at reducing CRC proliferation must be investigated. In clinical practice, CRC chemotherapy is often combined with radiation therapy with the aim of blocking the expansion of the tumor mass or removing residual cancer cells, though contemporary targeting of amino acid metabolism has not yet been explored. In the present study, we used the p53null Caco-2 model cell line to evaluate the effect of a possible combination of radiation and L-Asparaginase (L-ASNase), a protein drug that blocks cancer proliferation by impairing asparagine and glutamine extracellular supply. When L-ASNase was administered immediately after IR, we observed a reduced proliferative capability, a delay in DNA-damage response and a reduced capability to adhere and migrate. Our data suggest that a correctly timed combination of X-rays and L-ASNase treatment could represent an advantage in CRC therapy.


Subject(s)
Colonic Neoplasms , Colorectal Neoplasms , Humans , Asparagine/metabolism , Glutamine/metabolism , Caco-2 Cells , Tumor Suppressor Protein p53/genetics , Asparaginase/metabolism , Cell Line, Tumor , Radiation, Ionizing , Colorectal Neoplasms/genetics
3.
Radiother Oncol ; 168: 113-120, 2022 03.
Article in English | MEDLINE | ID: mdl-35033602

ABSTRACT

AIM: To quantify the dosimetric impact of contouring variability of axillary lymph nodes (L2, L3, L4) in breast cancer (BC) locoregional radiotherapy (RT). MATERIALS AND METHODS: 18 RT centres were asked to plan a locoregional treatment on their own planning target volume (single centre, SC-PTV) which was created by applying their institutional margins to the clinical target volume of the axillary nodes of three BC patients (P1, P2, P3) previously delineated (SC-CTV). The gold standard CTVs (GS-CTVs) of P1, P2 and P3 were developed by BC experts' consensus and validated with STAPLE algorithm. For each participating centre, the GS-PTV of each patient was created by applying the same margins as those used for the SC-CTV to SC-PTV expansion and replaced the SC-PTV in the treatment plan. Datasets were imported into MIM v6.1.7 [MIM Software Inc.], where dose-volume histograms (DVHs) were extracted and differences were analysed. RESULTS: 17/18 centres used intensity-modulated RT (IMRT). The CTV to PTV margins ranged from 0 to 10 mm (median 5 mm). No correlation was observed between GS-CTV coverage by 95% isodose and GS-PTV margins width. Doses delivered to 98% (D98) and 95% (D95) of GS-CTVs were significantly lower than those delivered to the SC-CTVs. No significant difference between SC-CTV and GS-CTV was observed in maximum dose (D2), always under 110%. Mean dose ≥99% of the SC-CTVs and GS-CTVs was satisfied in 84% and 50%, respectively. In less than one half of plans, GS-CTV V95% was above 90%. Breaking down the GS-CTV into the three nodal levels (L2, L3 and L4), L4 had the lowest probability to be covered by the 95% isodose. CONCLUSIONS: Overall, GS-CTV resulted worse coverage, especially for L4. IMRT was largely used and CTV-to-PTV margins did not compensate for contouring issues. The results highlighted the need for delineation training and standardization.


Subject(s)
Breast Neoplasms , Radiotherapy, Intensity-Modulated , Breast Neoplasms/radiotherapy , Female , Humans , Lymph Nodes , Radiometry/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
4.
Br J Radiol ; 94(1123): 20201177, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-33882239

ABSTRACT

OBJECTIVES: To determine interobserver variability in axillary nodal contouring in breast cancer (BC) radiotherapy (RT) by comparing the clinical target volume of participating single centres (SC-CTV) with a gold-standard CTV (GS-CTV). METHODS: The GS-CTV of three patients (P1, P2, P3) with increasing complexity was created in DICOM format from the median contour of axillary CTVs drawn by BC experts, validated using the simultaneous truth and performance-level estimation and peer-reviewed. GS-CTVs were compared with the correspondent SC-CTVs drawn by radiation oncologists, using validated metrics and a total score (TS) integrating all of them. RESULTS: Eighteen RT centres participated in the study. Comparative analyses revealed that, on average, the SC-CTVs were smaller than GS-CTV for P1 and P2 (by -29.25% and -27.83%, respectively) and larger for P3 (by +12.53%). The mean Jaccard index was greater for P1 and P2 compared to P3, but the overlap extent value was around 0.50 or less. Regarding nodal levels, L4 showed the highest concordance with the GS. In the intra-patient comparison, L2 and L3 achieved lower TS than L4. Nodal levels showed discrepancy with GS, which was not statistically significant for P1, and negligible for P2, while P3 had the worst agreement. DICE similarity coefficient did not exceed the minimum threshold for agreement of 0.70 in all the measurements. CONCLUSIONS: Substantial differences were observed between SC- and GS-CTV, especially for P3 with altered arm setup. L2 and L3 were the most critical levels. The study highlighted these key points to address. ADVANCES IN KNOWLEDGE: The present study compares, by means of validated geometric indexes, manual segmentations of axillary lymph nodes in breast cancer from different observers and different institutions made on radiotherapy planning CT images. Assessing such variability is of paramount importance, as geometric uncertainties might lead to incorrect dosimetry and compromise oncological outcome.


Subject(s)
Axilla , Breast Neoplasms/radiotherapy , Lymphatic Metastasis/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Breast Neoplasms/pathology , Female , Humans , Italy , Lymphatic Metastasis/pathology , Observer Variation
5.
Front Immunol ; 11: 1077, 2020.
Article in English | MEDLINE | ID: mdl-32655551

ABSTRACT

In vitro co-culture models between tumor cells and peripheral blood mononuclear cells (PBMCs) allow studying the interplay between these cell populations, potentially gaining insight into the in vivo response of the immune system to the presence of the tumor, as well as to possible other agents as radiation used for therapeutic purposes. However, great care is needed in the experimental optimization of models and choice of conditions, as some setups might offer a limited possibility to capture subtle immune perturbations. A co-culture model of PBMCs from healthy donors and colorectal adenocarcinoma Caco-2 cells was successfully adopted in a previous work to measure effects on Caco-2 and modulation of signaling when these latter are irradiated. We here tested if the same experimental setting allows to measure perturbations to the main PBMC subsets: we performed immunophenotyping by means of flow cytometry and quantified helper and cytotoxic T cells, NK cells, and B cells, when PBMCs are cultured alone (control), in presence of non-irradiated Caco-2 cells or when these latter are exposed to a 10 Gy X-ray dose from a conventional radiotherapy accelerator. To measure a baseline response in all experimental conditions, PBMCs were not further stimulated, but only followed in their time-evolution up to 72 h post-irradiation of Caco-2 and assembly of the co-culture. In this time interval PBMCs maintain a high viability (measured via the MTT assay). Caco-2 viability (MTT) is slightly affected by the presence of PBMCs and by the high radiation dose, confirming their radioresistance. Immunophenotyping results indicate a large inter-individual variability for different population subsets already at the control level. We analyzed relative population changes and we detected only a small but significant perturbation to cytotoxic T cells. We conclude that this model, as it is, is not adequate for the measurements of subtler immune perturbations (if any, not washed-out by inter-individual differences). For this purpose, the model needs to be modified and further optimized e.g., including a pre-treatment strategy for PBMCs. We also performed a pooled analysis of all experimental observations with principal component analysis, suggesting the potential of this tool to identify subpopulations of similarly-responding donors.


Subject(s)
Adenocarcinoma/immunology , Adenocarcinoma/radiotherapy , Colorectal Neoplasms/immunology , Colorectal Neoplasms/radiotherapy , Leukocytes, Mononuclear/immunology , Adenocarcinoma/pathology , Caco-2 Cells , Cell Survival/immunology , Cell Survival/radiation effects , Coculture Techniques/methods , Colorectal Neoplasms/pathology , Humans , Immunophenotyping , Leukocytes, Mononuclear/classification , Models, Immunological , Principal Component Analysis , Radiotherapy Dosage , T-Lymphocytes, Cytotoxic/immunology
6.
J Vis Exp ; (131)2018 01 30.
Article in English | MEDLINE | ID: mdl-29443050

ABSTRACT

The protocol adopted in this work aims at unraveling how X-rays perturb the functioning of the intestinal barrier, focusing on the interplay between colorectal tumor cells and the immune system. Colorectal carcinoma is among the most common type of cancer, typically treated by surgery, chemotherapy, and radiotherapy. Advantages of radiotherapy in targeting the tumor are well known. However, even limited exposures of healthy tissues are of great concern, particularly regarding the effects on the intestinal barrier and the immune system. The adopted setup allows to study the interplay between two cell populations in a condition more similar to the physiological one, when compared to normal cell cultures. For this purpose, we resort to different techniques and we used an in vitro co-culture model, based on Caco-2 cells differentiated as a monolayer and PBMC, sharing the same culture medium. This protocol has been developed to focus on both macroscopic effects, i.e. cell viability and Trans-Epithelial Electrical Resistance (TEER), and, through western blot, molecular alterations, i.e. the activation of inflammatory pathway in immune cells and the tight junction protein expression in Caco-2 cells. Initial evaluation of radiation effects on Caco-2 cell viability was assessed via the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) and Trypan blue assays, while TEER was measured at fixed time intervals through an ohmmeter specifically designed for co-culture systems. In this way, the effects due to radiation, the presence of Peripheral Blood Mononuclear Cells (PBMC), and eventually their synergistic effect, can be demonstrated. Through these complementary techniques, we observed a high radio-resistance of Caco-2 within the range of 2 - 10 Gy of X-rays and an increased Caco-2 monolayer permeability when PBMCs were added. In particular, PBMC presence was found to be associated with the variation in the tight junction scaffold proteins expression.


Subject(s)
Caco-2 Cells/cytology , Coculture Techniques/methods , Leukocytes, Mononuclear/cytology , Caco-2 Cells/radiation effects , Cell Differentiation/radiation effects , Humans , Leukocytes, Mononuclear/radiation effects , X-Rays
7.
J Appl Clin Med Phys ; 15(1): 4494, 2014 Jan 04.
Article in English | MEDLINE | ID: mdl-24423845

ABSTRACT

Deep inspiration breath hold (DIBH) in left-sided breast cancer radiotherapy treatments allows for a reduction in cardiac and pulmonary doses without compromising target coverage. The selection of the most appropriate technology for DIBH monitoring is a crucial issue. We evaluated the stability and reproducibility of DIBHs controlled by a spirometric device, by assessing the variability of the external surface position within a single DIBH (intra-DIBH) and between DIBHs performed in the same treatment session (intrafraction) or in different sessions (interfraction). The study included seven left-breast cancer patients treated with spirometer-based DIBH radiotherapy. Infrared optical tracking was used to record the 3D coordinates of seven to eleven passive markers placed on the patient's thoraco-abdominal surface during 29-43 DIBHs performed in six to eight treatment sessions. The obtained results showed displacements of the external surface between different sessions up to 6.3mm along a single direction, even at constant inspired volumes. The median value of the interfraction variability in the position of breast passive markers was 2.9 mm (range 1.9-4.8 mm) in the latero-lateral direction, 3.6 mm (range 2.2-4.6mm) in the antero-posterior direction, and 4.3mm (range 2.8-6.2 mm) in the cranio-caudal direction. There were no significant dose distribution variations for target and organs at risk with respect to the treatment plan, confirming the adequacy of the applied clinical margins (15 mm) to compensate for the measured setup uncertainties. This study demonstrates that spirometer-based control does not guarantee a stable and reproducible position of the external surface in left-breast DIBH radiotherapy, suggesting the need for more robust DIBH monitoring techniques when reduced margins and setup uncertainties are required for improving normal tissue sparing and decreasing cardiac and pulmonary toxicity.


Subject(s)
Breast Neoplasms/radiotherapy , Heart/radiation effects , Lung/radiation effects , Radiation Injuries/prevention & control , Radiation Monitoring , Respiration , Spirometry/methods , Algorithms , Computer Simulation , Female , Humans , Phantoms, Imaging , Prognosis , Radiotherapy Dosage , Radiotherapy, Adjuvant , Reproducibility of Results , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...