Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 145
Filter
1.
J Clin Med ; 13(10)2024 May 16.
Article in English | MEDLINE | ID: mdl-38792480

ABSTRACT

Background: Due to lower age thresholds for cataract surgery and increased longevity, cases with intraocular lens (IOL) dislocation requiring removal have increased. Traditional methods, such as cutting or folding the IOL within the eye, pose a high risk of complications, including corneal endothelial and iris damage. Methods: We developed a new minimally invasive technique for direct IOL removal using specially designed lens-grabbing forceps. These forceps can grasp and remove the IOL through a small incision in a single motion, significantly reducing intraocular manipulations compared to conventional methods. Results: In our test cases, IOL removal through a 2.2 mm corneal incision was completed in approximately 95 s, with minimal incision enlargement (about 0.16 mm) and a slight decrease in corneal endothelial cells. Conclusions: Our findings suggest that this technique is minimally invasive and safe for IOL removal, offering a promising alternative to existing methods.

2.
Bioengineering (Basel) ; 11(4)2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38671805

ABSTRACT

BACKGROUND: Facial recognition systems utilizing deep learning techniques can improve the accuracy of facial recognition technology. However, it remains unclear whether these systems should be available for patient identification in a hospital setting. METHODS: We evaluated a facial recognition system using deep learning and the built-in camera of an iPad to identify patients. We tested the system under different conditions to assess its authentication scores (AS) and determine its efficacy. Our evaluation included 100 patients in four postures: sitting, supine, and lateral positions, with and without masks, and under nighttime sleeping conditions. RESULTS: Our results show that the unmasked certification rate of 99.7% was significantly higher than the masked rate of 90.8% (p < 0.0001). In addition, we found that the authentication rate exceeded 99% even during nighttime sleeping. Furthermore, the facial recognition system was safe and acceptable for patient identification within a hospital environment. Even for patients wearing masks, we achieved a 100% success rate for authentication regardless of illumination if they were sitting with their eyes open. CONCLUSIONS: This is the first systematical study to evaluate facial recognition among hospitalized patients under different situations. The facial recognition system using deep learning for patient identification shows promising results, proving its safety and acceptability, especially in hospital settings where accurate patient identification is crucial.

3.
Br J Ophthalmol ; 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38485215

ABSTRACT

BACKGROUND: Artificial intelligence (AI) in medical imaging diagnostics has huge potential, but human judgement is still indispensable. We propose an AI-aided teaching method that leverages generative AI to train students on many images while preserving patient privacy. METHODS: A web-based course was designed using 600 synthetic ultra-widefield (UWF) retinal images to teach students to detect disease in these images. The images were generated by stable diffusion, a large generative foundation model, which we fine-tuned with 6285 real UWF images from six categories: five retinal diseases (age-related macular degeneration, glaucoma, diabetic retinopathy, retinal detachment and retinal vein occlusion) and normal. 161 trainee orthoptists took the course. They were evaluated with two tests: one consisting of UWF images and another of standard field (SF) images, which the students had not encountered in the course. Both tests contained 120 real patient images, 20 per category. The students took both tests once before and after training, with a cool-off period in between. RESULTS: On average, students completed the course in 53 min, significantly improving their diagnostic accuracy. For UWF images, student accuracy increased from 43.6% to 74.1% (p<0.0001 by paired t-test), nearly matching the previously published state-of-the-art AI model's accuracy of 73.3%. For SF images, student accuracy rose from 42.7% to 68.7% (p<0.0001), surpassing the state-of-the-art AI model's 40%. CONCLUSION: Synthetic images can be used effectively in medical education. We also found that humans are more robust to novel situations than AI models, thus showcasing human judgement's essential role in medical diagnosis.

4.
Sci Rep ; 14(1): 5292, 2024 03 04.
Article in English | MEDLINE | ID: mdl-38438495

ABSTRACT

To evaluate the visual performance of a diffractive bifocal intraocular lens (IOL) with + 4.0 D near addition (ZMB00) and a diffractive trifocal IOL with + 2.17 D and + 3.25 D near addition (AcrySof IQ PanOptix TFNT00), we investigated the 10-week postoperative parameters after cataract surgery in which ZMB00 or TFNT00 lenses were implanted bilaterally from 2011 to 2020 (with a 3-month interval between implantation of the right and left lenses). The study included 1448 eyes of 724 patients. The diffractive bifocal group comprised 1326 eyes of 663 patients (aged 67.0 ± 7.8 years; females/males, 518/145), and the diffractive trifocal group comprised 122 eyes of 61 patients (aged 66.6 ± 7.3 years; females/males, 35/26). A linear mixed-effects model using data for both eyes, with strict adjustments for sex, age, subjective refraction spherical equivalent, subjective refraction cylinder, corneal astigmatism, axial length, corneal higher-order aberrations, and pupil diameter, ensured statistical validity. Uncorrected near visual acuity and higher-order aberrations (ocular/internal, scaled to a pupil size of 4 mm) (Wavefront_4mm_postoperative_Ocular/Internal_Spherical) were significantly better in the bifocal group (p < 0.00068, Wald test). Uncorrected intermediate visual acuity, contrast sensitivity (6.3/4.0/2.5/1.6/1.0/0.7 degrees), and contrast sensitivity with glare (4.0/1.6/1.0/0.7 degrees) were significantly better in the trifocal group (p < 0.00068, Wald test).


Subject(s)
Lens, Crystalline , Lenses, Intraocular , Lenses , Female , Male , Humans , Eye, Artificial , Cornea
5.
Case Rep Ophthalmol ; 15(1): 129-135, 2024.
Article in English | MEDLINE | ID: mdl-38322312

ABSTRACT

Introduction: This case report aims to shed light on a rare presentation of familial exudative vitreoretinopathy (FEVR) co-existing with a large full-thickness macular hole (FTMH) in a 16-year-old male and discuss its successful surgical management, thereby adding to the limited existing knowledge on this topic. Case Presentation: Over an 8-month period, the patient had experienced progressively worsening visual blurring and distortion in his left eye. Following a comprehensive examination, diagnosis confirmed FEVR and an accompanying large FTMH. It was hypothesized that this unusual manifestation resulted from the tractional forces exerted by a thick posterior vitreous membrane and a thin epiretinal membrane - a distinctive attribute of FEVR. The patient underwent surgical intervention, which included pars plana vitrectomy (PPV), internal limiting membrane (ILM) peeling, gas tamponade, and the inverted ILM flap technique. Postoperative outcomes were favorable, with the FTMH successfully closed and substantial improvement observed in the patient's visual acuity at the 3-month follow-up visit. Conclusion: This case report highlights a rare association of FEVR with FTMH, thereby broadening our understanding of potential complications in patients with FEVR. The successful surgical intervention reinforces the utility of the PPV and the inverted ILM flap technique in managing such complications. It underscores the need for clinicians to maintain vigilance for such atypical manifestations in FEVR patients.

7.
Ophthalmol Sci ; 4(2): 100418, 2024.
Article in English | MEDLINE | ID: mdl-38146527

ABSTRACT

Purpose: The aim of this study was to examine the effects of foveal thickness (FT) fluctuation (FTF) on 2-year visual and morphological outcomes of eyes with central retinal vein occlusion (CRVO) undergoing anti-VEGF treatment for recurrent macular edema (ME) based on a pro re nata regimen. Design: Retrospective, observational case series. Participants: We analyzed 141 treatment-naive patients (141 eyes) with CRVO-ME at a multicenter retinal practice. Methods: We assessed FT using OCT at each study visit. Patients were divided into groups 0, 1, 2, and 3 according to increasing FTF. Main Outcome Measures: We evaluated the logarithm of the minimal angle of resolution (logMAR) best-corrected visual acuity (BCVA), the length of the foveal ellipsoid zone (EZ) band defect measured using OCT, and the association of FTF with VA and EZ band defect length. Results: The mean baseline logMAR BCVA and FT were 0.65 ± 0.52 (Snellen equivalent range: 20/20-20/2000) and 661.1 ± 257.4 µm, respectively. The mean number of anti-VEGF injections administered was 5.6 ± 3.6. At the final examination, the mean logMAR BCVA and FT values were significantly improved relative to the baseline values (both P < 0.01). During the observation, BCVA longitudinally improved in Groups 0 and 1, remained unchanged in Group 2, and worsened in Group 3. Likewise, the length of the foveal EZ band defect did not increase in Group 0; however, it gradually increased in Groups 1, 2, and 3. Foveal thickness fluctuation was significantly and positively associated with the logMAR BCVA and length of the foveal EZ band defect at the final examination (P < 0.01). The final logMAR BCVA of patients developing neovascular complications was 1.27 ± 0.72 (Snellen equivalent range: 20/50-counting fingers), which was significantly poorer than that of patients without complications (P < 0.001). There was no significant difference in the neovascular complication rate among the FTF groups (P = 0.106, Fisher exact test). Conclusions: In eyes receiving anti-VEGF treatment for CRVO-ME, FTF can longitudinally impair the visual acuity and foveal photoreceptor status during the observation period, thus influencing the final outcomes. However, neovascular complications, which would also lead to a poor visual prognosis, may not be associated with FTF. Financial Disclosures: The authors have no proprietary or commercial interest in any materials discussed in this article.

8.
Cureus ; 15(11): e48532, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38074014

ABSTRACT

Chorioretinal atrophy with pigmentation along the retinal veins was observed in the right fundus of a 49-year-old patient. Extensive retinitis pigmentosa (RP) was observed in the left eye. Dynamic quantitative visual field testing revealed a scotoma in the right eye that corresponded to the area of ​​retinochoroidal atrophy and afferent visual field constriction was observed on the left eye. An electroretinogram test revealed that the right eye showed attenuated type and the left eye showed negative type. Thus, the conditions of his right eye and left eye were diagnosed as pigmented paravenous retinochoroidal atrophy (PPRCA) and RP, respectively. Thus, there may be a higher proportion of PPRCA patients with unilateral RP than expected.

9.
Bioengineering (Basel) ; 10(12)2023 Dec 15.
Article in English | MEDLINE | ID: mdl-38136017

ABSTRACT

(1) Background: Age-related Macular Degeneration (AMD) is a critical condition leading to blindness, necessitating lifelong clinic visits for management, albeit with existing challenges in monitoring its long-term progression. This study introduced and assessed an innovative tool, the AMD long-term Information Viewer (AMD VIEWER), designed to offer a comprehensive display of crucial medical data-including visual acuity, central retinal thickness, macular volume, vitreous injection treatment history, and Optical Coherent Tomography (OCT) images-across an individual eye's entire treatment course. (2) Methods: By analyzing visit frequencies of patients with a history of invasive AMD treatment, a comparative examination between a Dropout group and an Active group underscored the clinical importance of regular visits, particularly highlighting better treatment outcomes and maintained visual acuity in the Active group. (3) Results: The efficiency of AMD VIEWER was proven by comparing it to manual data input by optometrists, showing significantly faster data display with no errors, unlike the time-consuming and error-prone manual entries. Furthermore, an elicited Net Promoter Score (NPS) of 70 from 10 ophthalmologists strongly endorsed AMD VIEWER's practical utility. (4) Conclusions: This study underscores the importance of regular clinic visits for AMD patients. It suggests the AMD VIEWER as an effective tool for improving treatment data management and display.

10.
Eur J Ophthalmol ; : 11206721231214142, 2023 Nov 08.
Article in English | MEDLINE | ID: mdl-37941398

ABSTRACT

INTRODUCTION: Many adverse occurrences in the eye have been reported after severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccination. This is the first report of a patient with an unruptured retinal arterial macroaneurysm (RAM) who developed branch retinal artery occlusion (BRAO) one day after SARS-CoV-2 vaccination (BNT162b2 by Pfizer-BioNTech). PATIENT REPORT: A 75-year-old man with a pertinent history of type-2 diabetes mellitus visited the hospital complaining of sudden visual loss in his right eye 1 day after receiving the fourth dose of the SARS-CoV-2 mRNA vaccine; his best-corrected visual acuity (BCVA) decreased from 1.0 to 0.7 (Snellen decimal). The patient had previously been diagnosed with an unruptured RAM and superior paracentral acute middle maculopathy in the same eye. Fundus examination showed increased sheathing of blood vessels. Indocyanine green showed a hyperfluorescent area suggestive of RAM on the right eye disc. Fluorescein angiography and optical coherence tomography angiography revealed arterial obstruction findings in the upper retinal area. DIAGNOSIS AND INTERVENTION: The patient was diagnosed with BRAO with RAM and was followed up without any additional treatment. Follow-up examination after 4 months did not show any improvement in BCVA value. CONCLUSION: This case suggested that BRAO could develop after SARS-CoV-2 vaccination in patients with unruptured RAM; however, more research is required to investigate the causes.

11.
Am J Ophthalmol Case Rep ; 32: 101914, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37654426

ABSTRACT

Purpose: This case report aims to describe the detailed time course of eccentric macular hole (MH) formation following pars plana vitrectomy (PPV) for epiretinal membrane (ERM) treatment, using optical coherence tomography (OCT) images. Observations: A 60-year-old male patient presented to our hospital with complaints of blurred vision and distortion in his left eye. He was diagnosed with an ERM in the affected eye and subsequently underwent PPV with internal limiting membrane peeling. The patient's initial postoperative course was unremarkable; however, one month later, macular edema worsened, as evidenced by OCT findings. Initially, the edema was observed in both nasal and temporal to the fovea. However, four months postoperatively, the retina fluid in the area nasal to the fovea resolved, and the resolution was delayed in the area temporal to the fovea. At 18 months postoperatively, an eccentric macular hole was detected in the temporal to the fovea. The patient remained asymptomatic, and at the two-year follow-up, the eccentric macular hole demonstrated no signs of enlargement. Conclusions and Importance: This case demonstrates the progression of an unusual asymptomatic parafoveal full-thickness retinal hole after PPV for ERM treatment. Since the development of this condition may occur over a more extended postoperative period than previously reported, long-term patient monitoring is essential following ERM or MH surgery.

12.
Cureus ; 15(8): e43828, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37736463

ABSTRACT

Superior sagittal sinus (SSS) obstruction causes intracranial hypertension, often requiring surgical stenting. Consensus on treating brain venous sinus stenosis, another cause, is lacking. This study reports a case of SSS stenosis and intracranial hypertension treated with venous stenting, improving bilateral papilledema. A 51-year-old with a headache and visual disturbance had papilledema and visual field loss. MR venography showed SSS stenosis, leading to a neurosurgery referral. Lumbar puncture confirmed intracranial hypertension (>35 cmH2O), prompting venous stenting. Post-procedure, papilledema, headache, and visual field loss improved. Venous stenting could be effective for SSS stenosis with clinically proven or recurrent pressure differences. Further cases are needed for standardization.

14.
PLoS One ; 18(7): e0288602, 2023.
Article in English | MEDLINE | ID: mdl-37440544

ABSTRACT

We compared the visual performance of a bifocal intraocular lens (IOL) (ZMB00) and an extended-depth-of-focus (EDOF) IOL (ZXR00V) by evaluating postoperative parameters at 10 weeks after the last surgery in cataract patients who underwent bilateral ZMB00 or ZXR00V implantation between 2011 and 2020. The right and left lenses were implanted within 3 months of each other. The study enrolled 1536 eyes of 768 patients; the ZMB00 group comprised 1326 eyes of 663 patients (age: 67.0 ± 7.8 years; female/male, 518/145), and the ZXR00V group comprised 210 eyes of 105 patients (age: 67.8 ± 6.9 years; female/male, 39/66). A linear mixed-effects model using data for both eyes, with strict adjustments for sex, age, subjective refraction spherical equivalent, subjective refraction cylinder, corneal astigmatism, axial length, corneal higher-order aberrations and pupil diameter, ensured statistical validity. Uncorrected near visual acuity, corrected near visual acuity, and near spectacle independence were significantly better in the ZMB00 group (p<0.00068, Wald test) than in the ZXR00V group. Contrast sensitivity (visual angle of the test target: 4.0°/2.5°/1.6°/1.0°/0.7°) and contrast sensitivity with glare (4.0°/2.5°/1.6°/1.0°/0.7°) were significantly better in the ZXR00V group (p<0.00068, Wald test) than in the ZMB00 group. Uncorrected intermediate visual acuity, contrast sensitivity with glare (6.3°), and 25-item National Eye Institute Visual Function Questionnaire (VFQ-25) scores for General Vision were slightly but significantly better in the ZXR00V group than in the ZMB00 group (p<0.05, Wald test). At high-performance levels, the two IOL groups had different characteristics regarding various visual performance parameters.


Subject(s)
Lenses, Intraocular , Phacoemulsification , Humans , Male , Female , Middle Aged , Aged , Lens Implantation, Intraocular , Eyeglasses , Visual Acuity , Refraction, Ocular , Patient Satisfaction , Prosthesis Design
15.
Sci Rep ; 13(1): 11348, 2023 07 13.
Article in English | MEDLINE | ID: mdl-37443278

ABSTRACT

This retrospective study examined the effect of the size of training data on the accuracy of machine learning-assisted SRK/T power calculation. Clinical records of 4800 eyes of 4800 Japanese patients with intraocular lenses (IOLs) were reviewed. A support vector regressor (SVR) was used for refining the SRK/T formula, and dataset sizes for training and evaluation were reduced from full to 1/64. The prediction errors from the postoperative refractions were calculated, and the proportion within ± 0.25 D, ± 0.50 D, and ± 1.00 D of errors were compared with those using full data. The influence of the difference in A-constant was also evaluated. Prediction errors within ± 0.50 D in the use of full data were obtained with the dataset of ≥ 150 eyes (P = 0.016), whereas the datasets of ≥ 300 eyes were required for the error within ± 0.25 D (P < 0.030). The prediction errors did not alter with the A-constant values among IOLs with open-loop haptics, except for IOLs with plated haptics. In conclusion, the accuracy of SVR-assisted SRK/T could be achieved with the training dataset of ≥ 150 eyes for the Japanese population, and the calculation was versatile for any open-looped IOLs.


Subject(s)
Lenses, Intraocular , Phacoemulsification , Humans , Refraction, Ocular , Lens Implantation, Intraocular , Visual Acuity , Retrospective Studies , Biometry , Optics and Photonics
16.
Sci Rep ; 13(1): 10650, 2023 06 30.
Article in English | MEDLINE | ID: mdl-37391497

ABSTRACT

A higher serum vascular endothelial growth factor (VEGF) level can cause choroidal thickening in the choroid of patients with polyneuropathy, organomegaly, endocrinopathy, monoclonal gammopathy, and skin changes (POEMS) syndrome. We aimed to determine whether fluctuations in serum VEGF levels affect choroidal vascular structures in patients with POEMS syndrome. This retrospective observational case series examined 17 left eyes of 17 patients with POEMS syndrome. Enhanced depth imaging optical coherence tomography (EDI-OCT) images were obtained, and serum VEGF levels were measured at baseline and 6 months after transplantation with dexamethasone (n = 6), thalidomide (n = 8), or lenalidomide (n = 3). EDI-OCT images were binarized using ImageJ software, and we calculated the areas of the whole choroid and the luminal and stromal areas. Subsequently, we determined whether the choroidal vascular structure had changed significantly between baseline and 6 months after treatment. Six months after treatment, serum VEGF levels and the whole choroid, luminal, and stromal areas had decreased significantly compared to the baseline values (all, P < 0.001). The mean luminal area to the whole choroidal area ratio at 6 months after treatment was 0.70 ± 0.03, which was significantly smaller than the ratio at baseline (0.72 ± 0.03; P < 0.001). Whole choroid and luminal area fluctuations were significantly positively correlated with fluctuations in serum VEGF levels (r = 0.626, P = 0.007 and r = 0.585, P = 0.014, respectively). Choroidal thickening induced by VEGF might be caused by increases in the choroidal vessel lumen area. These results may offer insights into the pathogenesis of POEMS syndrome and the role of serum VEGF in choroidal vascular structure, which may apply to other ocular diseases.


Subject(s)
Monoclonal Gammopathy of Undetermined Significance , POEMS Syndrome , Humans , Vascular Endothelial Growth Factor A , Retrospective Studies , Choroid/diagnostic imaging
17.
Int Ophthalmol ; 43(9): 3279-3286, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37227617

ABSTRACT

PURPOSE: The pathology of branch retinal vein occlusion (BRVO), a retinal circulatory disease, is related to monocular metamorphopsia-related vision impairment of the affected eyes, but the association of binocular metamorphopsia in such patients is unclear. This study aimed to examine the frequency of binocular metamorphopsia and its association with the clinical characteristics of patients with BRVO. METHODS: A total of 87 patients who were treated for BRVO-associated macular edema (ME) were included in this study. At baseline and 1 and 3 months after the initiation of anti-vascular endothelial growth factor (VEGF) treatment, we quantified metamorphopsia in the affected eyes and binocular metamorphopsia using the M-CHARTS® diagnostic tool. RESULTS: At baseline, 53 and 7 patients had metamorphopsia in the affected eyes and binocular metamorphopsia, respectively. Although the visual acuity improved significantly after the initiation of anti-VEGF treatment, the mean M-CHARTS score in the affected eyes did not change from the baseline score. At 3 months, 9 patients showed binocular metamorphopsia; it was significantly associated with metamorphopsia in the affected eyes with a 95% confidence interval of 0.021-0.122 (ß = 0.306, p = 0.006). CONCLUSION: Metamorphopsia in the affected eyes can cause binocular metamorphopsia in patients with BRVO-ME.


Subject(s)
Macular Edema , Retinal Vein Occlusion , Humans , Retinal Vein Occlusion/complications , Retinal Vein Occlusion/diagnosis , Retinal Vein Occlusion/drug therapy , Macular Edema/diagnosis , Vascular Endothelial Growth Factor A , Eye/pathology , Vision Disorders/diagnosis , Vision Disorders/etiology , Intravitreal Injections , Tomography, Optical Coherence , Angiogenesis Inhibitors/therapeutic use , Retrospective Studies
18.
J Clin Med ; 12(5)2023 Feb 24.
Article in English | MEDLINE | ID: mdl-36902602

ABSTRACT

The aim of this study was to analyze the refraction and iris capture tendency regarding the fixation position with respect to the intrascleral fixation (ISF) of intraocular lenses. Consecutive patients who underwent ISF 1.5 mm (ISF 1.5, 45 eyes) and 2.0 mm (ISF 2.0, 55 eyes) from the corneal limbus with NX60, as well as those who underwent normal phacoemulsification with in-the-bag ZCB00V (ZCB, 50 eyes), were enrolled. The anterior chamber depth (post-op ACD), the estimated ACD when using the SRK/T (post-op ACD-predicted ACD), and the refractive error (post-op MRSE, and the predicted MRSE) were all calculated. In addition, the postoperative iris capture was also investigated. The post-op MRSE-predicted MRSE values were: -0.59, 0.02, and 0.00 D (ISF 1.5, ISF 2.0, and ZCB) (p < 0.05, between ISF 1.5 vs. ISF 2.0 and ZCB); the post-op ACD values were: 4.00, 4.17, and 4.29 mm (p < 0.05, ISF 1.5 vs. ZCB); and the post-op ACD-predicted ACD values were: -2.03, -1.98, and -1.60 mm (p < 0.05, between ZCB vs. ISF 1.5 and ISF 2.0). The iris capture occurred in four eyes with regard to ISF 1.5 and three eyes with ISF 2.0 (p = 0.52). Moreover, ISF 2.0 possessed 0.6D hyperopia and 0.17 mm deeper anterior chamber depth. The refractive error of ISF 2.0 was less than that of ISF 1.5. Lastly, no significant iris capture onset was noted between ISF 1.5 mm and 2.0 mm.

19.
Cureus ; 15(1): e33295, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36741669

ABSTRACT

BACKGROUND: It is important to maintain intraocular pressure during cataract surgery. When the intraocular pressure sharply drops during phacoemulsification, it is important to ensure a compensatory maximum fluid supply. To the best of our knowledge, this is the first study presenting the maximum irrigation flow supply using an ultrasonic tip shape and torsional power setting. METHODS: The weight of BSS PLUS 500 ejected during torsional oscillation fitted with a mini-tip or balanced tip and nano sleeve with IOP set at 20 mmHg (IOP20) or 40 mmHg (IOP40) was measured. The weight of the BSS ejected from the sleeve over 3.0 s (15 measurements taken at 200-ms intervals) was measured to calculate the irrigation flow feeding rate. Measurements were made four times at each torsional power setting (TP). RESULTS: With a balanced tip, the irrigation flow rate rose as TP was increased, whereas, at 60% or 90% TP, the irrigation flow rate markedly decreased. With the mini-tip, the irrigation flow rate remained relatively stable, up to 60% or 80% TP but decreased dramatically at higher power settings. Compared with IOP20, the irrigation flow rate increased by 1.21- to 1.28-fold with the balanced tip and by 1.28- to 1.41-fold with the mini-tip at IOP40. At IOP20, the irrigation flow rate was higher with the mini-tip at 0% and 5% TP but equal to or higher with the balanced tip at TP of ≥10%. At IOP40, the irrigation flow rate with the mini-tip was equal to or higher than that with the balanced tip at all TP. CONCLUSIONS: The irrigation flow rate tends to vary with changes in TP and tip shape.

20.
J Clin Med ; 12(3)2023 Feb 02.
Article in English | MEDLINE | ID: mdl-36769842

ABSTRACT

This article compares the visual performance of a violet light-filtering colored lens (ZCB00V) and blue light-filtering intraocular lens (IOL; SN60WF) before and after modifying the manufacturing process for glistening suppression. In this retrospective study, conducted at Saneikai Tsukazaki Hospital, Himeji, Japan, a consecutive sample of 8943 eyes of 5119 patients were included and implanted with blue-filtering IOLs before and after modifying the manufacturing process (SN60WF-J (1318 eyes) and SN60WF-Q,A (1418 eyes), respectively), noncolored UV-cut IOLs (ZCB00 (1418 eyes)), and ZCB00V (3717 eyes). For each patient, the corrected distance visual acuity (CDVA) at 3 months postoperative (3MCDVA) and the area under log contrast sensitivity function (AULCSF) were measured. The 3MCDVA was -0.076 ± 0.1, -0.11 ± 0.13, -0.10 ± 0.17, and -0.11 ± 0.13, for SN60WF-J, SN60WF-Q,A, ZCB00, and ZCB00V, respectively. The SN60WF-J group revealed significant differences as compared to the other three groups (all p < 0.05). The mesopic AULCSF was 2.59 ± 0.20, 2.68 ± 0.19, -2.69 ± 0.18, and 2.76 ± 0.19, respectively, whereas the photopic AULSCF was 2.63 ± 0.23, 2.76 ± 0.25, -2.77 ± 0.25, and 2.88 ± 0.25. The SN60WF-J and ZCB00V groups exhibited significant differences as compared to the other three groups, whereas no significant differences were noted between the SN60WF-Q,A and the ZCB00 groups (all p < 0.05). The violet-filtering lens offers higher visual acuity and contrast sensitivity than the clear and blue-filtering lens. It was also found that the above functions were improved by modifying the manufacturing process.

SELECTION OF CITATIONS
SEARCH DETAIL
...