ABSTRACT
Fluid dynamics studies have proposed that coronary flow reserve can be calculated from coronary artery pressure instead of coronary blood flow. We sought to investigate the diagnostic performance of pressure-bounded coronary flow reserve (pb-CFR) compared with CFR measured by conventional thermodilution method (CFRthermo) in the clinical setting. Pressure guidewire was used to measure CFRthermo and fractional flow reserve (FFR) in left anterior descending coronary artery in 62 patients with stable coronary artery disease. Pb-CFR was calculated only with resting distal coronary artery pressure (Pd), resting aortic pressure (Pa) and FFR. Pb-CFR was moderately correlated with CFRthermo (r = 0.54, P < 0.001). Pb-CFR showed a poor agreement with CFRthermo, presenting large values of mean difference and root mean square deviation (1.5 ± 1.4). Pb-CFR < 2.0 predicted CFRthermo < 2.0 with an accuracy of 79%, sensitivity of 83%, specificity of 78%, positive predictive value of 48%, negative predictive value of 95%. The discordance presenting CFRthermo < 2.0 and pb-CFR ≥ 2.0 was associated with diffuse disease (P < 0.001). The discordance presenting CFRthermo ≥ 2 and pb-CFR < 2 was associated with a high FFR (P = 0.002). Pb-CFR showed moderate correlation and poor agreement with CFRthermo. Pb-CFR might be reliable in excluding epicardial coronary artery disease and microcirculatory disorders.
Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Humans , Coronary Artery Disease/diagnosis , Fractional Flow Reserve, Myocardial/physiology , Microcirculation , Lead , Coronary Vessels/diagnostic imaging , Predictive Value of Tests , Coronary Stenosis/diagnosis , Coronary AngiographyABSTRACT
BACKGROUND: Fractional flow reserve (FFR) and nonhyperemic pressure ratios (NHPRs) have been widely used to assess the functional severity of coronary stenosis. However, their measurement requires using a pressure wire, making their use in all patients difficult. The recently developed vessel fractional flow reserve (vFFR), derived from three-dimensional quantitative coronary angiography, is expected to serve as a surrogate for pressure wire assessment. METHODS: This retrospective study was conducted on patients with intermediate coronary stenosis who underwent FFR and NHPR measurements. The vFFR and NHPR values were compared for diagnosing coronary stenosis as defined by an FFR of ≤0.80, and the number of patients not requiring wire-based assessment was estimated. RESULTS: In a total of 90 lesions from 74 patients (median [SD] age 75 [12] years; men 80%), the median FFR was 0.78 (0.72-0.84), and 57% of these lesions (N = 51) exhibited an FFR of ≤0.80. vFFR provided high discrimination for coronary stenosis (area under the curve 0.80, 95% confidence interval 0.70-0.90), which was comparable to that of NHPRs (p = 0.42). High diagnostic accuracy was consistently observed across a variety of clinical presentations (i.e., old age, diabetes, target coronary artery, and left ventricular hypertrophy) (pinteraction > 0.05). In total, 55 lesions (61%) demonstrated positive or negative likelihood of coronary stenosis when vFFR was <0.73 (specificity 90%) or >0.87 (sensitivity 88%), respectively. CONCLUSION: vFFR demonstrated excellent diagnostic performance for detecting functionally significant coronary stenosis as evaluated by FFR. vFFR may be used as a surrogate for pressure wire assessment.