Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Endosc Ultrasound ; 13(2): 115-122, 2024.
Article in English | MEDLINE | ID: mdl-38947747

ABSTRACT

Background and Objectives: EUS tissue acquisition (EUS-TA) is the standard diagnostic method for solid pancreatic lesions (SPLs); however, there are few reports on EUS-TA results for SPLs ≤10 mm. Furthermore, given the recent advent of fine-needle biopsy, the current diagnostic accuracy of EUS-TA for SPLs ≤10 mm is unknown. This study aimed to evaluate the diagnostic accuracy and efficacy of EUS-TA for SPLs ≤10 mm. Methods: We retrospectively analyzed the data of 109 patients with SPLs ≤10 mm who underwent EUS-TA. All patients underwent rapid on-site specimen evaluation. Results: The median tumor diameter was 8 mm (range, 2.5-10 mm), and the technical success rate was 99.1% (108/109). Adverse events were observed in 3 patients (2.8%). The diagnostic performance was as follows: sensitivity, 90.1% (64/71); specificity, 97.3% (36/37); accuracy, 92.6% (100/108); positive predictive value, 98.5% (64/65); and negative predictive value, 83.7% (36/43). Multivariate analysis revealed that the number of punctures (odds ratio, 7.03; 95% confidence interval, 1.32-37.5; P = 0.023) and tumor type (odds ratio, 11.90; 95% confidence interval, 1.38-102.0; P = 0.024) were independent risk factors for inaccurate EUS-TA results. The diagnostic accuracy of EUS-TA for pancreatic ductal adenocarcinoma was 87.5% (14/16). No EUS-TA-related needle-tract seeding was observed in patients with pancreatic ductal adenocarcinoma during the observation period. Conclusions: EUS-TA for SPLs ≤10 mm showed adequate diagnostic accuracy and was safe for use with rapid on-site specimen evaluation in all cases.

2.
Article in English | MEDLINE | ID: mdl-38845460

ABSTRACT

BACKGROUND AND AIM: Endoscopic ultrasound-guided gastroenterostomy is a procedure used to connect the stomach and dilated afferent loop using a stent under endoscopic ultrasound for afferent loop syndrome. However, the actual efficacy and safety of this procedure remain unclear. Therefore, this retrospective study aimed to evaluate the efficacy and safety of endoscopic ultrasound-guided gastroenterostomy using a laser-cut-type fully covered self-expandable metallic stent and an anchoring plastic stent for afferent loop syndrome. METHODS: Technical and clinical success rates, adverse events, recurrent intestinal obstruction rates, time to recurrent intestinal obstruction, and technical and clinical success rates of re-intervention were evaluated in intended patients who underwent endoscopic ultrasound-guided gastroenterostomy for afferent loop syndrome from October 2018 to August 2022. RESULTS: In 25 intended patients with afferent loop syndrome who intended endoscopic ultrasound-guided gastroenterostomy, the technical success rate was 100% (25/25), whereas the clinical success rate was 96% (24/25). Two patients experienced grade ≥ 3 early adverse events, including one with intra-abdominal abscess and one with hypotension. Both events were attributed to intestinal fluid leakage. No late adverse events were observed. The recurrent intestinal obstruction rate was 32% (8/25), and the median time to recurrent intestinal obstruction was 6.5 months (95% confidence interval: 2.8-not available). The technical and clinical success rates of re-intervention were both 100% (8/8). CONCLUSIONS: Endoscopic ultrasound-guided gastroenterostomy using a fully covered self-expandable metallic stent and an anchoring plastic stent is effective and safe as a treatment procedure for afferent loop syndrome.

3.
Endosc Int Open ; 12(3): E367-E376, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38464977

ABSTRACT

Background and study aims Endoscopic gastroduodenal stent (GDS) deployment is currently a standard treatment for malignant gastric outlet obstruction (mGOO) in patients with limited life expectancy; however, stent dysfunction (SD) and complicated pancreatitis often occur after GDS deployment. We investigated incidence and contributing factors of SD and complicated pancreatitis. Patients and methods We retrospectively reviewed 203 patients who underwent initial GDS deployment for palliation of mGOO symptoms between October 2017 and July 2022, including 109 who underwent GDS deployment across the duodenal papilla (sub-cohort). Results SDs, including tumor ingrowth (n = 26), kinking (n = 14), and migration (n = 13), occurred in 68 patients (33.5%). Cumulative SD incidence was 41.1% (95% confidence interval, 32.6-49.4%). SD incidence increased to 0.4%, 0.16%, and 0.06% per day at < 8, 8-16, and>16 weeks, respectively. On multivariate analysis, Niti-S pyloric/duodenal stent deployment (sub-distribution hazard ratio [sHR] 0.26, P = 0.01) and survival length ≥ 90 days (sHR 2.5, P = 0.01) were respectively identified as favorable and risk factors significantly associated with SD. Pancreatitis developed in 14 patients (12.8%) in the sub-cohort, which had significantly higher parenchymal diameter ( P < 0.01) and lower main pancreatic duct (MPD) caliber ( P < 0.01) than the non-pancreatitis cohort. On multivariate analysis, MPD caliber < 3 mm independently predicted pancreatitis (odds ratio 6.8, P = 0.03). Conclusions Deployment of the Niti-S pyloric/duodenal stent, with conformability even for angulated strictures, significantly reduced the incidence of SD. Stent selection, life expectancy, and MPD caliber should be taken into consideration during decision-making for GDS deployment for mGOO.

4.
BMJ Open ; 13(12): e078967, 2023 12 10.
Article in English | MEDLINE | ID: mdl-38072497

ABSTRACT

INTRODUCTION: The current endoscopic treatment for postoperative benign hepaticojejunostomy anastomotic stricture (HJAS) has a high technical success rate and is highly effective in the short term. However, long-term results have shown a high rate of stenosis recurrence, which indicates an insufficient response to treatment. Three prospective studies on fully covered self-expandable metallic stent (FC-SEMS) treatment for benign HJAS used the stenosis resolution rate as the primary endpoint, and no study has yet used the long-term non-stenosis rate (at 12 months) as the primary endpoint. METHODS AND ANALYSIS: We launched the 'saddle-cross study', which will be conducted as a multicentre, prospective intervention of endoscopic treatment using two modified FC-SEMSs (BONASTENT️ M-Intraductal) that have been improved for benign stenosis in patients with benign HJAS, with the long-term non-restenosis rate (at 12 months) as the primary endpoint. This study aims to evaluate the long-term non-restenosis rate (at 12 months) and safety of the saddle-cross technique for benign HJAS. We plan to enrol 50 participants. ETHICS AND DISSEMINATION: This study has been approved by the Certified Review Board of the National Cancer Center, Japan (CRB3180009). The results will be reported at various conferences and published in international peer-reviewed journals.


Subject(s)
Self Expandable Metallic Stents , Humans , Constriction, Pathologic/etiology , Constriction, Pathologic/surgery , Prospective Studies , Treatment Outcome , Retrospective Studies , Self Expandable Metallic Stents/adverse effects , Stents , Clinical Trials, Phase II as Topic , Multicenter Studies as Topic
5.
J Gastroenterol ; 58(7): 693-703, 2023 07.
Article in English | MEDLINE | ID: mdl-37154933

ABSTRACT

BACKGROUND: For non-functioning pancreatic neuroendocrine tumors (pNETs) ≤ 20 mm, most guidelines consider follow-up observations as an option; however, the various treatment strategies are defined by size alone, even though the Ki-67 index is important for malignancy grading. Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is the standard for the histopathological diagnosis of solid pancreatic lesions; however, recent results for small lesions remain unclear. Therefore, we examined the efficacy of EUS-TA for solid pancreatic lesions ≤ 20 mm suspected as pNETs or requiring differentiation and the non-increase rate in tumor size in follow-up cases. METHODS: We retrospectively analyzed data of 111 patients (median age = 58 years) with lesions ≤ 20 mm suspected as pNETs or requiring differentiation who underwent EUS-TA. All patients underwent specimen evaluation by rapid onsite evaluation (ROSE). RESULTS: EUS-TA led to a diagnosis of pNETs in 77 patients (69.4%) and tumors other than pNETs in 22 patients (19.8%). The histopathological diagnostic accuracy of EUS-TA was 89.2% (99/111) overall, 94.3% (50/53) for 10-20 mm lesions, and 84.5% (49/58) for ≤ 10 mm lesions, with no significant difference in diagnostic accuracy (p = 0.13). The Ki-67 index was measurable in all patients with a histopathological diagnosis of pNETs. Among 49 patients with a diagnosis of pNETs who were followed up, one patient (2.0%) showed tumor enlargement. CONCLUSIONS: EUS-TA for solid pancreatic lesions ≤ 20 mm suspected as pNETs or requiring differentiation is safe and has adequate histopathological diagnostic accuracy, suggesting that follow-up observations of pNETs with a histological pathologic diagnosis are acceptable in the short term.


Subject(s)
Neuroectodermal Tumors, Primitive , Neuroendocrine Tumors , Pancreatic Neoplasms , Humans , Middle Aged , Neuroendocrine Tumors/diagnostic imaging , Neuroendocrine Tumors/pathology , Retrospective Studies , Ki-67 Antigen , Endoscopic Ultrasound-Guided Fine Needle Aspiration , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/pathology
6.
Diagnostics (Basel) ; 13(3)2023 Jan 26.
Article in English | MEDLINE | ID: mdl-36766558

ABSTRACT

Attempts at performing endoscopic ultrasound-guided tissue acquisition (EUS-TA) with a 19G needle are increasing because histological diagnosis and comprehensive genomic profiling are a necessity. However, the diagnostic ability of the 19G fine-needle biopsy (FNB) needle, especially the third-generation FNB needle, is unclear and has been retrospectively reviewed. The 19G TopGain needle was used in 147 patients and 160 lesions between September 2020 and December 2021. The technical success rate of the biopsies was 99.4% (159/160). The early adverse event rate was 4.1% (6/147), and moderate or severe adverse event rate occurrence was 2.0% (3/147). The sensitivity, specificity, and accuracy of the 19G TopGain needle for 157 lesions with a confirmed diagnosis were 96.7%, 100%, and 96.8%, respectively. Rescue EUS-TA using the 19G TopGain needle was performed for nine lesions, and a successful diagnosis was made in six of these lesions (66.7%). The diagnostic ability of EUS-TA using the third-generation 19G TopGain needle was favorable. However, the use of 19G FNB needles may increase adverse events. Therefore, EUS-TA with a 19G FNB needle is mainly indicated in lesions where comprehensive genomic profiling may be necessary or the diagnosis could not be determined via EUS-TA using the 22G needle.

7.
Endosc Int Open ; 11(1): E97-E104, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36712906

ABSTRACT

Background and study aims Recently, the utility of endoscopic ultrasound-guided intervention without fistula dilation (EUS-IV WoD) has been reported to prevent adverse events. We clinically evaluated cases in which EUS-IV WoD was attempted using a novel self-expandable metallic stent (SEMS); this is a fully covered, laser-cut SEMS that has a tapered and stiff tip specifically designed for a 0.025-inch guidewire and a relatively thin, 7F delivery system. Patients and methods We retrospectively evaluated cases wherein EUS-IV WoD was attempted using the novel SEMS between March and December 2021. Results Treatment of 11 patients by EUS-IV WoD with the novel SEMS was attempted. The technical success rate for EUS-IV was 100 % and the clinical success rate was 100 %; the success rate for EUS-IV WoD was 72.8 %. Of these, the procedural success rate for EUS-IV WoD was 100 % in EUS-biliary drainage (BD) and 57.1 % in non-EUS-BD. Early adverse events were observed in 27.3 % of patients (3/11): mild abdominal pain in two patients and moderate bleeding in one patient. The abdominal pain cases were both cases of EUS-IV WoD failure and required fistula dilation. Conclusions The novel stent may be useful for EUS-IV WoD, especially in EUS-BD.

8.
Dig Endosc ; 35(1): 124-133, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35993898

ABSTRACT

OBJECTIVES: Comprehensive genomic profiling (CGP) has been approved in Japan since June 2019, enabling mutation-specific therapy. Although tissue sampling via endoscopic ultrasound-guided tissue acquisition (EUS-TA) is standard in pancreatic cancer, reports on obtaining appropriate samples for CGP, especially for the OncoGuide NCC Oncopanel System (NOP) and FoundationOne CDx (FOne), are lacking. Therefore, we investigated the success rate and factors related to appropriate EUS-TA sampling for CGP analysis suitability in unresectable pancreatic ductal adenocarcinoma (UR-PDAC). METHODS: Participants comprised 150 UR-PDAC patients who underwent EUS-TA and tumor sample evaluation for CGP analysis suitability between June 2019 and December 2021. The proportion of patients meeting the criteria was evaluated considering tumor size, puncture lesion, presence of metastasis, type and size of puncture needle, suction method, number of punctures, and puncture route. RESULTS: In total, 39.2% (60/153) of samples met NOP analysis suitability criteria and 0% met FOne analysis suitability criteria. The suitability rate was significantly higher with 19G fine-needle biopsy (FNB) (56.0%; 42/75) than with 22G FNB (32.6%; 14/43) and 22G fine-needle aspiration (11.4%; 4/35). Nineteen-gauge needle (odds ratio [OR] 2.53; 95% confidence interval [CI] 1.15-5.57; P = 0.021) and FNB (OR 3.57; 95% CI 1.05-12.20; P = 0.041) were independent factors contributing to NOP analysis suitability. Among 30 patients who underwent actual NOP analysis, the analysis success rate was 100% (30/30). CONCLUSION: In sample collection via EUS-TA, 19G and FNB needles contribute to NOP analysis suitability.


Subject(s)
Adenocarcinoma , Pancreatic Neoplasms , Humans , Pancreas/diagnostic imaging , Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Pancreatic Neoplasms/genetics , Pancreatic Neoplasms/pathology , Adenocarcinoma/pathology , Genomics , Pancreatic Neoplasms
10.
BMJ Case Rep ; 15(1)2022 Jan 07.
Article in English | MEDLINE | ID: mdl-34996768

ABSTRACT

An 82-year-old man presented to the emergency department with abdominal pain and febrile symptoms that had been present for 4 days. Blood tests showed elevated liver enzymes and white blood cell count, and abdominal contrast-enhanced CT revealed a 35 mm cystic lesion in the left lateral liver lobe. On closer examination, the cystic lesion was found to have contiguous bile duct dilatation and internal nodules. Furthermore, mucus production was observed during endoscopic retrograde cholangiopancreatography, which led to the diagnosis of intraductal papillary neoplasm of the bile duct (IPNB), with cystic infection. Although the patient was an older adult, there was no background disease that would have prevented surgery, and resection was performed. Pathological examination revealed type 1 IPNB, with invasive carcinoma. The number of reports of IPNB is expected to increase with an increasing older population in Asia, and we report the findings of this case.


Subject(s)
Bile Duct Neoplasms , Carcinoma, Papillary , Carcinoma , Aged , Aged, 80 and over , Bile Duct Neoplasms/diagnostic imaging , Bile Duct Neoplasms/surgery , Bile Ducts , Bile Ducts, Intrahepatic/surgery , Humans , Male
11.
BMJ Case Rep ; 14(3)2021 Mar 30.
Article in English | MEDLINE | ID: mdl-33785604

ABSTRACT

A 78 year-old female status post subarachnoid haemorrhage developed abdominal pain and obstructive jaundice. CT scan showed acute cholecystitis and dilation of the intrahepatic ducts. Endoscopic retrograde cholangiography revealed hepatic duct stenosis due to compression by an enlarged gallbladder. No stones were seen in the common hepatic duct and the cystic duct was patent. An endoscopic retrograde biliary drain was placed to relieve the obstructive jaundice due to acute acalculous cholecystitis. Percutaneous transhepatic drainage was performed to treat the acute acalculous cholecystitis. Hepatic duct stenosis was improved on endoscopic retrograde cholangiography performed 19 days after percutaneous transhepatic drainage. It may be reasonable to treat 'Mirizzi-like syndrome' non-operatively.


Subject(s)
Acalculous Cholecystitis , Cholecystitis, Acute , Jaundice, Obstructive , Acalculous Cholecystitis/complications , Acalculous Cholecystitis/diagnostic imaging , Acalculous Cholecystitis/surgery , Aged , Cholangiography , Cholangiopancreatography, Endoscopic Retrograde , Cholecystitis, Acute/complications , Cholecystitis, Acute/diagnostic imaging , Cholecystitis, Acute/surgery , Female , Hepatic Duct, Common , Humans , Jaundice, Obstructive/etiology
12.
Case Rep Gastroenterol ; 14(3): 593-597, 2020.
Article in English | MEDLINE | ID: mdl-33250702

ABSTRACT

Most cases of anisakiasis occur in the stomach. Colonic anisakiasis, especially when asymptomatic, is extremely rare. We report a case of asymptomatic colonic anisakiasis and present a literature review of cases of colonic anisakiasis. A 52-year-old man underwent colonoscopy for colorectal cancer screening. Although no colorectal neoplasm was found, an Anisakis larva was detected in the transverse colon and the larva was removed by grasping forceps. Our review of PubMed revealed that 40% of cases of colonic anisakiasis are asymptomatic. We conclude that asymptomatic colonic anisakiasis may not be as rare as conventionally assumed.

SELECTION OF CITATIONS
SEARCH DETAIL
...