Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Diabetes Res Clin Pract ; 214: 111772, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38972600

ABSTRACT

INTRODUCTION: Diabetes Mellitus (DM) is a common chronic disease, affecting 435 million people globally. Impaired vasculature in DM patients leads to complications like lower extremity arterial disease (LEAD) and foot ulcers, often resulting in amputations. DM causes additional peripheral neuropathy leading to multifactorial wound problems. Current diagnostics often deem unreliable, but Near-Infrared Fluorescence with Indocyanine Green (ICG NIR) can be used to assess the foot perfusion. Therefore, this study explores DM's impact on foot perfusion using ICG NIR. METHODS: Baseline ICG NIR fluorescence imaging was performed in LEAD patients with and without DM. Ten perfusion parameters were extracted and analyzed to assess differences in perfusion patterns. RESULTS: Among 109 patients (122 limbs) of the included patients, 32.8 % had DM. Six of ten perfusion parameters, mainly inflow-related, differed significantly between DM and non-DM patients (p-values 0.007-0.039). Fontaine stage 4 DM patients had the highest in- and outflow values, with seven parameters significantly higher (p-values 0.004-0.035). CONCLUSION: DM is associated with increased in- and outflow parameters. Patients with- and without DM should not be compared directly due to different vascular pathophysiology and multifactorial wound problems in DM patients. Quantified ICG NIR fluorescence imaging offers additional insight into the effect of DM on foot perfusion.


Subject(s)
Diabetic Foot , Foot , Indocyanine Green , Humans , Female , Male , Middle Aged , Aged , Diabetic Foot/physiopathology , Diabetic Foot/diagnostic imaging , Diabetic Foot/diagnosis , Foot/blood supply , Foot/diagnostic imaging , Foot/physiopathology , Optical Imaging/methods , Diabetes Mellitus/physiopathology , Diabetes Mellitus/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/diagnosis
2.
Angiology ; : 33197231186096, 2023 Jun 26.
Article in English | MEDLINE | ID: mdl-37358400

ABSTRACT

Contemporary quality control methods are often insufficient in predicting clinical outcomes after revascularization in lower extremity arterial disease (LEAD) patients. This study evaluates the potential of near-infrared fluorescence imaging with indocyanine green to predict the clinical outcome following revascularization. Near-infrared fluorescence imaging was performed before and within 5 days following the revascularization procedure. Clinical improvement was defined as substantial improvement of pain free walking distance, reduction of rest- and/or nocturnal pain, or tendency toward wound healing. Time-intensity curves and 8 perfusion parameters were extracted from the dorsum of the treated foot. The quantified postinterventional perfusion improvement was compared within the clinical outcome groups. Successful near-infrared fluorescence imaging was performed in 72 patients (76 limbs, 52.6% claudication, 47.4% chronic limb-threatening ischemia) including 40 endovascular- and 36 surgical/hybrid revascularizations. Clinical improvement was observed in 61 patients. All perfusion parameters showed a significant postinterventional difference in the clinical improvement group (P-values <.001), while no significant differences were seen in the group without clinical improvement (P-values .168-.929). Four parameters demonstrated significant differences in percentage improvement comparing the outcome groups (P-values within .002-.006). Near-infrared fluorescence imaging has promising additional value besides clinical parameters for predicting the clinical outcome of revascularized LEAD patients.

3.
Surg Endosc ; 37(9): 6824-6833, 2023 09.
Article in English | MEDLINE | ID: mdl-37286750

ABSTRACT

BACKGROUND: Indocyanine green near-infrared fluorescence bowel perfusion assessment has shown its potential benefit in preventing anastomotic leakage. However, the surgeon's subjective visual interpretation of the fluorescence signal limits the validity and reproducibility of the technique. Therefore, this study aimed to identify objective quantified bowel perfusion patterns in patients undergoing colorectal surgery using a standardized imaging protocol. METHOD: A standardized fluorescence video was recorded. Postoperatively, the fluorescence videos were quantified by drawing contiguous region of interests (ROIs) on the bowel. For each ROI, a time-intensity curve was plotted from which perfusion parameters (n = 10) were derived and analyzed. Furthermore, the inter-observer agreement of the surgeon's subjective interpretation of the fluorescence signal was assessed. RESULTS: Twenty patients who underwent colorectal surgery were included in the study. Based on the quantified time-intensity curves, three different perfusion patterns were identified. Similar for both the ileum and colon, perfusion pattern 1 had a steep inflow that reached its peak fluorescence intensity rapidly, followed by a steep outflow. Perfusion pattern 2 had a relatively flat outflow slope immediately followed by its plateau phase. Perfusion pattern 3 only reached its peak fluorescence intensity after 3 min with a slow inflow gradient preceding it. The inter-observer agreement was poor-moderate (Intraclass Correlation Coefficient (ICC): 0.378, 95% CI 0.210-0.579). CONCLUSION: This study showed that quantification of bowel perfusion is a feasible method to differentiate between different perfusion patterns. In addition, the poor-moderate inter-observer agreement of the subjective interpretation of the fluorescence signal between surgeons emphasizes the need for objective quantification.


Subject(s)
Colorectal Neoplasms , Colorectal Surgery , Humans , Indocyanine Green , Colorectal Neoplasms/surgery , Anastomosis, Surgical/methods , Colorectal Surgery/methods , Reproducibility of Results , Anastomotic Leak/prevention & control , Perfusion
4.
Eur J Surg Oncol ; 49(5): 990-995, 2023 05.
Article in English | MEDLINE | ID: mdl-36914531

ABSTRACT

INTRODUCTION: Anastomotic leakage is a severe complication after oesophageal resection with gastric conduit reconstruction. Poor perfusion of the gastric conduit plays an important role in the development of anastomotic leakage. Quantitative near-infrared (NIR) fluorescence angiography with indocyanine green (ICG-FA) is an objective technique that can be used for perfusion assessment. This study aims to assess perfusion patterns of the gastric conduit with quantitative ICG-FA. METHODS: In this exploratory study, 20 patients undergoing oesophagectomy with gastric conduit reconstruction were included. A standardized NIR ICG-FA video of the gastric conduit was recorded. Postoperatively, the videos were quantified. Primary outcomes were the time-intensity curves and nine perfusion parameters from contiguous regions of interest on the gastric conduit. A secondary outcome was the inter-observer agreement of subjective interpretation of the ICG-FA videos between six surgeons. The inter-observer agreement was tested with an intraclass correlation coefficient (ICC). RESULTS: In a total of 427 curves, three distinct perfusion patterns were recognized: pattern 1 (steep inflow, steep outflow); pattern 2 (steep inflow, minor outflow); and pattern 3 (slow inflow, no outflow). All perfusion parameters were significantly different between the perfusion patterns. The inter-observer agreement was poor - moderate (ICC:0.345,95%CI:0.164-0.584). DISCUSSION: This was the first study to describe perfusion patterns of the complete gastric conduit after oesophagectomy. Three distinct perfusion patterns were observed. The poor inter-observer agreement of the subjective assessment underlines the need for quantification of ICG-FA of the gastric conduit. Further studies should evaluate the predictive value of perfusion patterns and parameters on anastomotic leakage.


Subject(s)
Anastomotic Leak , Indocyanine Green , Humans , Anastomotic Leak/diagnostic imaging , Anastomotic Leak/etiology , Esophagectomy/adverse effects , Stomach/diagnostic imaging , Stomach/surgery , Perfusion/adverse effects , Anastomosis, Surgical/methods
5.
Ann Vasc Surg ; 93: 283-290, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36642169

ABSTRACT

BACKGROUND: The angiosome concept is defined as the anatomical territory of a source artery within all tissue layers. When applying this theory in vascular surgery, direct revascularization (DR) is preferred to achieve increased blood flow toward the targeted angiosome of the foot in patients with lower extremity arterial disease (LEAD). This study evaluates the applicability of the angiosome concept using quantified near-infrared (NIR) fluorescence imaging with indocyanine green (ICG). METHODS: This study included patients undergoing an endovascular- or surgical revascularization of the leg between January 2019 and December 2021. Preinterventional and postinterventional ICG NIR fluorescence imaging was performed. Three angiosomes on the dorsum of the foot were determined: the posterior tibial artery (hallux), the anterior tibial artery (dorsum of the foot) and the combined angiosome (second to fifth digit). The angiosomes were classified from the electronic patient records and the degree of collateralization was classified based on preprocedural computed tomography angiography and/or X-ray angiography. Fluorescence intensity was quantified in all angiosomes. A subgroup analysis based on endovascular or surgical revascularized angiosomes, and within critical limb threatening ischemia (CLTI) patients was performed. RESULTS: ICG NIR fluorescence measurements were obtained in 52 patients (54 limbs) including a total of 157 angiosomes (121 DR and 36 indirect revascularizations [IR]). A significant improvement of all perfusion parameters in both the directly and indirectly revascularized angiosomes was found (P-values between <0.001-0.007). Within the indirectly revascularized angiosomes, 90.6% of the scored collaterals were classified as significant. When comparing the percentual change in perfusion parameters between the directly and indirectly revascularized angiosomes, no significant difference was seen in all perfusion parameters (P-values between 0.253 and 0.881). Similar results were shown in the CLTI patients subgroup analysis, displaying a significant improvement of perfusion parameters in both the direct and indirect angiosome groups (P-values between <0.001 and 0.007), and no significant difference when comparing the percentual parameter improvement between both angiosome groups (P-values between 0.134 and 0.359). Furthermore, no significant differences were observed when comparing percentual changes of perfusion parameters in directly and indirectly revascularized angiosomes for both endovascular and surgical interventions (P-values between 0.053 and 0.899). CONCLUSIONS: This study proves that both DR and IR of an angiosome leads to an improvement of perfusion. This suggests that interventional strategies should not only focus on creating in-line flow to the supplying angiosome. One can argue that the angiosome concept is not applicable in patients with LEAD.


Subject(s)
Indocyanine Green , Limb Salvage , Humans , Treatment Outcome , Limb Salvage/methods , Foot/blood supply , Tibial Arteries , Ischemia , Regional Blood Flow
6.
J Endovasc Ther ; 30(3): 364-371, 2023 06.
Article in English | MEDLINE | ID: mdl-35236169

ABSTRACT

PURPOSE: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) is gaining popularity for the quantification of tissue perfusion, including foot perfusion in patients with lower extremity arterial disease (LEAD). However, the absolute fluorescence intensity is influenced by patient-and system-related factors limiting reliable and valid quantification. To enhance the quality of quantitative perfusion assessment using ICG NIR fluorescence imaging, normalization of the measured time-intensity curves seems useful. MATERIALS AND METHODS: In this cohort study, the effect of normalization on 2 aspects of ICG NIR fluorescence imaging in assessment of foot perfusion was measured: the repeatability and the region selection. Following intravenous administration of ICG, the NIR fluorescence intensity in both feet was recorded for 10 mins using the Quest Spectrum platform®. The effect of normalization on repeatability was measured in the nontreated foot in patients undergoing unilateral revascularization preprocedural and postprocedural (repeatability group). The effect of normalization on region selection was performed in patients without LEAD (region selection group). Absolute and normalized time-intensity curves were compared. RESULTS: Successful ICG NIR fluorescence imaging was performed in 54 patients (repeatability group, n = 38; region selection group, n = 16). For the repeatability group, normalization of the time-intensity curves displayed a comparable inflow pattern for repeated measurements. For the region selection group, the maximum fluorescence intensity (Imax) demonstrated significant differences between the 3 measured regions of the foot (P = .002). Following normalization, the time-intensity curves in both feet were comparable for all 3 regions. CONCLUSION: This study shows the effect of normalization of time-intensity curves on both the repeatability and region selection in ICG NIR fluorescence imaging. The significant difference between absolute parameters in various regions of the foot demonstrates the limitation of absolute intensity in interpreting tissue perfusion. Therefore, normalization and standardization of camera settings are essential steps toward reliable and valid quantification of tissue perfusion using ICG NIR fluorescence imaging.


Subject(s)
Indocyanine Green , Lower Extremity , Humans , Cohort Studies , Treatment Outcome , Optical Imaging/methods , Perfusion
SELECTION OF CITATIONS
SEARCH DETAIL