1.
Environ Toxicol Pharmacol ; 110: 104499, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39019244

ABSTRACT

This study aimed to evaluate the environmental impact of dental materials: commercial composite Tetric EvoCeram®, glass ionomer Equia Forte® HT Fil, laboratory-prepared composite, alkasite Cention® Forte, amalgam Amalcap® Plus, and samples from dental chair drainage systems (DCDS). Methacrylate monomers were detected in the eluates of experimental and commercials composites, and alkasite. In DCDS samples solely mercury was found at concentrations of 0.08-1.86 µg/L. The experimental composite (48 h incubation) exhibited the highest toxicity on zebrafish Danio rerio (LC50=0.70 g/L), followed by amalgam (LC50=8.27 g/L) < Tetric EvoCeram® (LC50=10.94 g/L) < Equia Forte® HT Fil (LC50=24.84 g/L) < Cention® Forte (LC50=32.22 g/L). Exposure of zebrafish to DCDS samples resulted in decreased larval body length and increased occurrences of edema and blood accumulation. The results obtained highlight the need for additional monitoring and further research on the release of unreacted monomers and mercury from dental materials and their environmental impact.

2.
Materials (Basel) ; 17(11)2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38894041

ABSTRACT

This study aimed to evaluate the micro-mechanical and macro-mechanical properties of self-cured and light-cured alkasite and to investigate how accelerated degradation in acidic, alkaline, and ethanol solutions affects the macro-mechanical properties of self-cured and light-cured alkasite. The specimens of the alkasite material (Cention Forte, Ivoclar Vivadent) were prepared according to the following three curing modes: (1) light-cured immediately, (2) light-cured after a 5-min delay, and (3) self-cured. Microhardness was tested before and after immersion in absolute ethanol to indirectly determine crosslink density, while flexural strength and flexural modulus were measured using a three-point bending test after accelerated aging in the following solutions: (1) lactic acid solution (pH = 4.0), (2) NaOH solution (pH = 13.0), (3) phosphate-buffered saline solution (pH = 7.4), and (4) 75% ethanol solution. The data were statistically analyzed using a two-way ANOVA and Tukey post hoc test. The results showed that the microhardness, flexural strength, and flexural modulus were significantly lower in self-cured specimens compared to light-cured specimens. A 5-min delay between the extrusion of the material from the capsule and light curing had no significant effect on any of the measured properties. A significant effect of the accelerated aging solutions on macro-mechanical properties was observed, with ethanol and alkaline solutions having a particularly detrimental effect. In conclusion, light curing was preferable to self-curing, as it resulted in significantly better micro- and macro-mechanical properties, while a 5-min delay between mixing the capsule and light curing had no negative effects.

3.
Materials (Basel) ; 17(10)2024 May 13.
Article in English | MEDLINE | ID: mdl-38793364

ABSTRACT

This study investigated the effect of 3 s light-curing with a high-power LED curing unit on the shear bond strength of bulk-fill composites. Four bulk-fill composites were bonded to dentin with a universal adhesive (Scotchbond Universal Plus): two materials designed for rapid curing (Tetric PowerFill and Tetric PowerFlow) and two controls (Filtek One Bulk Fill Restorative and SDR Plus Bulk Fill Flowable). The 4 mm composite layer was light-cured with Bluephase PowerCure for 20 s at 1000 mW/cm2 ("20 s") or for 3 s at 3000 mW/cm2 ("3 s"). The samples were stored at 37 °C in distilled water and tested after 1, 6 and 12 months. The samples polymerised in the "3 s" mode had statistically similar or higher bond strength than the samples cured in "20 s" mode, except for the Tetric PowerFlow (1 month) and SDR+ (6 month). The flowable materials Tetric PowerFlow and SDR Plus initially showed the highest values in the "3 s" and "20 s" groups, which decreased after 12 months. The bond strength was statistically similar for all materials and curing protocols after 12 months, except for Tetric PowerFill cured with the "3 s" protocol (21.22 ± 5.0 MPa), which showed the highest value. Tetric PowerFill showed the highest long-term bond strength. While "3 s" curing resulted in equal or better shear bond strength, its use can only be recommended for a material with an AFCT agent such as Tetric PowerFill.

4.
Acta Stomatol Croat ; 58(1): 30-38, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38562217

ABSTRACT

Objective: The aim of this study was to compare the light transmission of monowave and polywave-curing devices by a bulk-fill composite containing only camphorquinone as a photoinitiator. Materials and methods: Three light-curing devices were used to cure bulk-fill composite QuiXfil: one monowave (Translux® Wave) and two polywave (VALO Cordless and Bluephase® PowerCure. The NIST-calibrated spectrometer (MARC Resin Calibrator, BlueLight Analytics Inc.) was used to measure the incident and transmitted light through a 2-mm composite specimen over 20 s. Light transmittance was calculated from the ratio of the amount of transmitted and incident light. For data analysis (ANOVA, α = 0.05), total irradiation of the entire spectrum, irradiation with wavelengths of 360-420 nm for the violet spectrum, and 420-540 nm for the blue spectrum were selected. Results: Monowave curing unit Translux® Wave had the lowest light transmission (13.78 ± 0.5%), similar to the violet light transmission of polywave devices (12.02 ± 0.94% and 13.81 ± 1.72% for Valo Cordless and Bluephase PowerCure, respectively). Blue light transmittance (32.15-23.70%) was more than twofold higher than for the wavelengths in the violet region of the spectrum (13.81-12.02%) for the two polywave devices. VALO Cordless showed the highest total and blue light transmission (p<0.001). There was no significant difference in the transmission of the violet part of the spectrum between VALO Cordless and Bluephase® PowerCure (p = 0.465). Conclusion: Within the limitations of this study, we could conclude that polywave curing devices can be used for the polymerization of the bulk-fill composite with camphorquinone as the sole photoinitiator.

5.
Polymers (Basel) ; 16(3)2024 Jan 24.
Article in English | MEDLINE | ID: mdl-38337207

ABSTRACT

The aim of this study was to examine the influence of the orthodontic bracket material on the short-term and long-term post-cure development of the degree of conversion (DC) of resin-based orthodontic adhesive systems. Five commercially available materials characterized by different compositions and curing modes (light-curable or dual-curable) were tested under three different light curing conditions: without brackets (control group, CO), and in the presence of metal brackets (MB group) or ceramic brackets (CB group). Fourier-transform infrared spectroscopy was used to determine the post-cure DC development, both after "short-term" periods (2, 6, and 10 min) and "long-term" periods (1, 7, and 28 days). The short-term DC values ranged from 43.9% to 76.1%, and the long-term DC values were higher and ranged from 54.3% to 85.3%. The MB group demonstrated significantly lower short-term DC values compared to the CO and the CB groups, while the CB group had statistically similar or slightly lower DC values compared to the CO group. Long-term DC values in the MB and the CB groups were statistically lower or similar compared to the CO group, which depended on the post-cure time. The results indicated that the post-cure DC development was highly material-dependent and affected by the presence of different types of bracket material.