Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Viruses ; 13(5)2021 05 12.
Article in English | MEDLINE | ID: mdl-34066205

ABSTRACT

This study describes a case of SARS-CoV-2 reinfection confirmed by whole-genome sequencing in a healthy physician who had been working in a COVID-19 hospital in Italy since the beginning of the pandemic. Nasopharyngeal swabs were obtained from the patient at each presentation as part of routine surveillance. Nucleic acid amplification testing was performed on the two samples to confirm SARS-CoV-2 infection, and serological tests were used to detect SARS-CoV-2 IgG antibodies. Comparative genome analysis with whole-genome sequencing was performed on nasopharyngeal swabs collected during the two episodes of COVID-19. The first COVID-19 episode was in March 2020, and the second was in January 2021. Both SARS-CoV-2 infections presented with mild symptoms, and seroconversion for SARS-CoV-2 IgG was documented. Genomic analysis showed that the viral genome from the first infection belonged to the lineage B.1.1.74, while that from the second infection to the lineage B.1.177. Epidemiological, clinical, serological, and genomic analyses confirmed that the second episode of SARS-CoV-2 infection in the healthcare worker met the qualifications for "best evidence" for reinfection. Further studies are urgently needed to assess the frequency of such a worrisome occurrence, particularly in the light of the recent diffusion of SARS-CoV-2 variants of concern.


Subject(s)
COVID-19/transmission , Reinfection/genetics , SARS-CoV-2/pathogenicity , Adult , Antibodies, Viral/genetics , COVID-19/genetics , Female , Genome, Viral/genetics , Health Personnel , Humans , Immunoglobulin G , Italy/epidemiology , Reinfection/metabolism , SARS-CoV-2/genetics , Serologic Tests , Whole Genome Sequencing/methods
2.
Respirology ; 18(6): 968-73, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23600534

ABSTRACT

BACKGROUND AND OBJECTIVE: Nocturnal application of continuous positive airway pressure (CPAP) is the standard treatment for patients with obstructive sleep apnoea (OSA). Determination of the therapeutic pressure (CPAP titration) is usually performed by a technician in the sleep laboratory during attended polysomnography. One possible alternative to manual titration is automated titration. Indeed, during the last 15 years, devices have been developed that deliver autoadjustable CPAP (A-CPAP). The aim of the present study was to compare the titration effectiveness of two A-CPAP devices using different flow-based algorithms in patients with OSA. METHODS: This is a randomized study; 79 subjects underwent two consecutive unattended home A-CPAP titration nights with two different devices (Autoset Resmed; Remstar Auto Respironics); during the third and the fourth night, patients underwent portable monitoring in the sleep laboratory during fixed CPAP at the A-CPAP recommended pressure. RESULTS: Bland Altman plots showed good agreement between the recommended median and maximal pressure levels obtained with the two devices. A significant improvement was observed in all the sleep parameters by both A-CPAP machines to a similar degree. CONCLUSIONS: It was observed that the two A-CPAP devices using different algorithms are equally effective in initial titration of CPAP.


Subject(s)
Algorithms , Continuous Positive Airway Pressure/instrumentation , Sleep Apnea, Obstructive/therapy , Aged , Continuous Positive Airway Pressure/methods , Female , Humans , Male , Middle Aged , Polysomnography , Prospective Studies , Treatment Outcome
3.
Respir Care ; 58(7): 1178-83, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23051680

ABSTRACT

BACKGROUND: Obstructive sleep apnea is a disorder characterized by recurrent obstruction of the upper airways during sleep. The high prevalence of this disease led to proposed new strategies based on the home evaluation and management of patients. OBJECTIVE: To compare home unattended portable monitoring and automatic CPAP titration with attended in-laboratory analysis, in a sample of patients with high risk for moderate to severe obstructive sleep apnea. METHODS: We enrolled 131 subjects, who were randomly divided into 2 groups: the home group (n = 66) was diagnosed and titrated at home; the laboratory group (n = 65) was analyzed in the sleep laboratory of our hospital. Diagnostic evaluations were carried out with portable monitoring at home, and with polysomnography in the sleep laboratory. Titration of CPAP was performed with the same automatic CPAP device in both groups. RESULTS: At the end of the study, 13 (19%) subjects had dropped out of the home group, and 9 (14%) of the laboratory group (P = .50). There were no significant differences among groups in both baseline and with-CPAP values of apnea-hypopnea index, oxygen desaturation index, and total sleep time with SpO2 below 90%. In the home group, the therapeutic pressure values reached at the end of each unattended home titration night were similar. CONCLUSIONS: A home diagnosis and titration approach should be considered in a subset of patients with obstructive sleep apnea. A single unattended titration night is sufficient to determine the therapeutic pressure.


Subject(s)
Continuous Positive Airway Pressure , Home Care Services , Monitoring, Physiologic , Polysomnography/methods , Sleep Apnea, Obstructive , Aged , Comparative Effectiveness Research , Continuous Positive Airway Pressure/instrumentation , Continuous Positive Airway Pressure/methods , Female , Humans , Male , Middle Aged , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Risk Assessment , Severity of Illness Index , Sleep Apnea, Obstructive/diagnosis , Sleep Apnea, Obstructive/physiopathology , Sleep Apnea, Obstructive/therapy , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...