Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr A ; 1646: 462086, 2021 Jun 07.
Article in English | MEDLINE | ID: mdl-33892255

ABSTRACT

Stand-alone electrospray ionization mass spectrometry (ESI-MS) has been advancing through enhancements in throughput, selectivity and sensitivity of mass spectrometers. Unlike traditional MS techniques which usually require extensive offline sample preparation and chromatographic separation, many sample preparation techniques are now directly coupled with stand-alone MS to enable outstanding throughput for bioanalysis. In this review, we summarize the different sample clean-up and/or analyte enrichment strategies that can be directly coupled with ESI-MS and nano-ESI-MS for the analysis of biological fluids. The overview covers the hyphenation of different sample preparation techniques including solid phase extraction (SPE), solid phase micro-extraction (SPME), slug flow micro-extraction/nano-extraction (SFME/SFNE), liquid extraction surface analysis (LESA), extraction electrospray, extraction using digital microfluidics (DMF), and electrokinetic extraction (EkE) with ESI-MS and nano-ESI-MS.


Subject(s)
Spectrometry, Mass, Electrospray Ionization/methods , Miniaturization , Solid Phase Microextraction/methods , Specimen Handling
2.
J Chromatogr A ; 1642: 462032, 2021 Apr 12.
Article in English | MEDLINE | ID: mdl-33714769

ABSTRACT

Liquid-liquid extraction is one of the most widely used and simplest sample preparation techniques. However, consumption of large volumes of organic solvent and manual handling are two major drawbacks of this technique. A multifunction autosampler syringe is introduced which permits automated liquid-liquid extraction in an enclosed operating environment, with low consumption of organic solvents. The device described herein features a micromixer function in addition to common autosampler syringe features like accurate and precise aspirating and dispensing. To test the functionality of the micromixer syringe, manual extraction of caffeine from a tea infusion and semi-automated extraction of dichloroethane from water were carried out. Excellent recoveries of caffeine from a tea infusion (89% recovery with 1.3% RSD) and dichloroethane from water (107% recovery with 10% RSD) were obtained. Two automated workflows were tested using the micromixer syringe mounted in a laboratory autosampler. Standalone automated micro liquid-liquid extraction was performed for sample preparation of selected polychlorinated biphenyl (PCB) congeners prior to comprehensive two-dimensional gas chromatography - electron capture detection analysis. Extraction of PCBs using the described approach used substantially less solvent than a validated solid-phase extraction approach whilst delivering equivalent results for samples with high-level PCBs. Finally, fully automated extraction and GC-MS analysis of polynuclear aromatic hydrocarbons (PAHs) from water samples was performed. Mean recoveries of extraction for PCB and PAH analysis were > 70% using 4 min automated liquid-liquid extractions.


Subject(s)
Liquid-Liquid Extraction/instrumentation , Liquid-Liquid Extraction/methods , Organic Chemicals/isolation & purification , Water/chemistry , Gas Chromatography-Mass Spectrometry , Organic Chemicals/analysis , Polychlorinated Biphenyls/analysis , Polychlorinated Biphenyls/isolation & purification , Polycyclic Aromatic Hydrocarbons/analysis , Polycyclic Aromatic Hydrocarbons/isolation & purification , Solvents , Syringes , Water Pollutants, Chemical/analysis
3.
Angew Chem Int Ed Engl ; 59(51): 23162-23168, 2020 12 14.
Article in English | MEDLINE | ID: mdl-32869436

ABSTRACT

Here, an electrokinetic extraction (EkE) syringe is presented allowing for on-line electrokinetic removal of serum proteins before ESI-MS. The proposed concept is demonstrated by the determination of pharmaceuticals from human serum within minutes, with sample preparation limited to a 5× dilution of the sample in the background electrolyte (BGE) and application of voltage, both of which can be performed in-syringe. Signal enhancements of 3.6-32 fold relative to direct infusion of diluted serum and up to 10.8 fold enhancement, were obtained for basic and acidic pharmaceuticals, respectively. Linear correlations for the basic drugs by EkE-ESI-MS/MS were achieved, covering the necessary clinical range with LOQs of 5.3, 7.8, 6.1, and 17.8 ng mL-1 for clomipramine, chlorphenamine, pindolol, and atenolol, respectively. For the acidic drugs, the EkE-ESI-MS LOQs were 3.1 µg mL-1 and 2.9 µg mL-1 for naproxen and paracetamol, respectively. The EkE-ESI-MS and EkE-ESI-MS/MS methods showed good accuracy (%found of 81 % to 120 %), precision (≤20 %), and linearity (r>0.997) for all the studied drugs in spiked serum samples.


Subject(s)
Blood Proteins/isolation & purification , Syringes , Acetaminophen/blood , Atenolol/blood , Blood Proteins/chemistry , Chlorpheniramine/blood , Clomipramine/blood , Humans , Kinetics , Naproxen/blood , Pindolol/blood , Spectrometry, Mass, Electrospray Ionization
4.
Anal Chem ; 91(13): 8259-8266, 2019 07 02.
Article in English | MEDLINE | ID: mdl-31141347

ABSTRACT

A 25 µL analytical glass syringe has been used for isoelectric focusing (IEF) utilizing the stainless-steel needle and plunger as electrodes. The generation of protons and hydroxyl ions at the electrodes facilitated a neutralization reaction boundary (NRB) mechanism to focus different amphoteric compounds, such as hemoglobin, bovine serum albumin, R-phycoerythrin, and histidine, within minutes. After optimization of different experimental parameters affecting the IEF process and the coupling of the IEF syringe with electrospray ionization mass spectrometry (ESI-MS), a BGE composed of NH4Ac, 1.0 mM, pH 4.0, in 70.0% (v/v) acetonitrile was used for the IEF of histidine. A voltage of -200 V was applied for 5.0 min to accomplish the IEF and increased to -400 V during the infusion to ESI-MS at a flow rate of 4.0 µL/min. The coaxial sheath liquid consisting of 0.2% (v/v) formic acid was added at 4.0 µL/min. The detection limit was found to be 2.2 µg/mL and a nonlinear quadratic fit calibration curve was constructed for histidine over the range of 4.0-64.0 µg/mL with a correlation coefficient ( r) = 0.9998. The determination of histidine in spiked urine samples as relevant for the diagnosis of histidinemia was demonstrated by the IEF syringe-ESI-MS system with accuracy from 88.25% to 102.16% and a relative standard deviation less than 11%.


Subject(s)
Histidine/urine , Isoelectric Focusing/methods , Spectrometry, Mass, Electrospray Ionization/methods , Amino Acid Metabolism, Inborn Errors/diagnosis , Buffers , Histidine Ammonia-Lyase/deficiency , Humans , Reproducibility of Results , Syringes
5.
Electrophoresis ; 38(1): 33-59, 2017 01.
Article in English | MEDLINE | ID: mdl-27678139

ABSTRACT

One of the most cited limitations of capillary (and microchip) electrophoresis is the poor sensitivity. This review continues to update this series of biennial reviews, first published in Electrophoresis in 2007, on developments in the field of on-line/in-line concentration methods in capillaries and microchips, covering the period July 2014-June 2016. It includes developments in the field of stacking, covering all methods from field amplified sample stacking and large volume sample stacking, through to isotachophoresis, dynamic pH junction, and sweeping. Attention is also given to on-line or in-line extraction methods that have been used for electrophoresis.


Subject(s)
Electrophoresis, Capillary/methods , Isotachophoresis/methods , Microchip Analytical Procedures/methods , Capillary Electrochromatography , Cell Line , Humans , Inorganic Chemicals/analysis , Isoelectric Focusing , Nanostructures/analysis , Organic Chemicals/analysis , Sensitivity and Specificity
6.
Biomicrofluidics ; 7(5): 51502, 2013.
Article in English | MEDLINE | ID: mdl-24273628

ABSTRACT

Microfluidic technology provides precise, controlled-environment, cost-effective, compact, integrated, and high-throughput microsystems that are promising substitutes for conventional biological laboratory methods. In recent years, microfluidic cell culture devices have been used for applications such as tissue engineering, diagnostics, drug screening, immunology, cancer studies, stem cell proliferation and differentiation, and neurite guidance. Microfluidic technology allows dynamic cell culture in microperfusion systems to deliver continuous nutrient supplies for long term cell culture. It offers many opportunities to mimic the cell-cell and cell-extracellular matrix interactions of tissues by creating gradient concentrations of biochemical signals such as growth factors, chemokines, and hormones. Other applications of cell cultivation in microfluidic systems include high resolution cell patterning on a modified substrate with adhesive patterns and the reconstruction of complicated tissue architectures. In this review, recent advances in microfluidic platforms for cell culturing and proliferation, for both simple monolayer (2D) cell seeding processes and 3D configurations as accurate models of in vivo conditions, are examined.

SELECTION OF CITATIONS
SEARCH DETAIL