Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 147
Filter
1.
Article in English | MEDLINE | ID: mdl-38639138

ABSTRACT

Despite progressively uncommon in Western countries, rheumatic heart disease still portrays a significant global burden. In elderly or high-surgical risk patients, plurivalvular disease may require a complex percutaneous approach. Transcatheter aortic valve implantation (TAVI) in patients with previous monoleaflet mitral prosthesis is challenging due to interference between the aortic valve and the rigid mitral mechanical prosthesis "ring." Prior cases report the use of CoreValve or Edwards Sapien aortic valves in patients with adequate mitro-aortic distance. Performing a second major procedure, such as tricuspid valve-in-valve (TVIV), sequentially during a single percutaneous intervention, increases treatment complexity. An 83-year-old woman with rheumatic heart disease, with previous implantation of a Bjork-Shiley monoleaflet mitral prosthesis, and Carpentier-Edwards 29 tricuspid bioprosthesis presented with decompensated heart failure due to severe aortic stenosis and tricuspid bioprosthesis stenosis. After HeartTeam discussion, the patient was deemed as inoperable due to a prohibitive surgical risk. As an alternative, a TAVI (Navitor FlexNav) and a transcatheter TVIV replacement (Edwards Sapiens 3 Ultra) were discussed and proposed, with both techniques being performed sequentially in a single procedure. TAVI in a patient with a previous monoleaflet mitral mechanical prosthesis and TVIV may be a feasible approach in inoperable patients with plurivalvular disease.

2.
Am Heart J ; 270: 86-94, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38309610

ABSTRACT

BACKGROUND: Patients with severe aortic stenosis (AS) frequently present with concomitant obstructive coronary artery disease (CAD). In those, current guidelines recommend combined coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) as the preferred treatment option, although this surgical approach is associated with a high rate of clinical events. Combined transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) with or without FFR have evolved as a valid alternative for cardiac surgery in patients with AS and multivessel or advanced CAD. To date, no dedicated trial has prospectively evaluated the outcomes of a percutaneous versus surgical treatment for patients with both severe AS and CAD. AIMS: To investigate whether fractional-flow reserve (FFR)-guided PCI and TAVI is noninferior to combined CABG and SAVR for the treatment of severe AS and multivessel or advanced CAD. METHODS: The Transcatheter Valve and Vessels (TCW) trial (clinicaltrial.gov: NCT03424941) is a prospective, randomized, controlled, open label, international trial. Patients ≥ 70 years with severe AS and multivessel (≥ 2 vessels) or advanced CAD, deemed feasible by the heart team for both; a full percutaneous or surgical treatment, will be randomised in a 1:1 fashion to either FFR-guided PCI followed by TAVI (intervention arm) vs. CABG and SAVR (control arm). The primary endpoint is a patient-oriented composite of all-cause mortality, myocardial infarction, disabling stroke, unscheduled clinically-driven target vessel revascularization, valve reintervention, and life threatening or disabling bleeding at 1 year. The TCW trial is powered for noninferiority, and if met, superiority will be tested. Assuming a primary endpoint rate of 30% in the CABG-SAVR arm, with a significance level α of 5%, a noninferiority limit delta of 15% and a loss to follow-up of 2%, a total of 328 patients are needed to obtain a power of 90%. The primary endpoint analysis is performed on an intention-to-treat basis. SUMMARY: The TCW Trial is the first prospective randomized trial that will study if a less invasive percutaneous treatment for severe AS and concomitant advanced CAD (i.e., FFR-guided PCI-TAVI) is noninferior to the guidelines recommended approach (CABG-SAVR).


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Fractional Flow Reserve, Myocardial , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Humans , Coronary Artery Disease/complications , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Aortic Valve/surgery , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Coronary Artery Bypass , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Treatment Outcome
3.
JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38180419

ABSTRACT

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Pandemics , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/epidemiology , Treatment Outcome , COVID-19/epidemiology , Registries , Risk Factors
4.
Article in English | MEDLINE | ID: mdl-38262740

ABSTRACT

BACKGROUND AND AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing transcatheter aortic valve intervention (TAVI). METHODS: We followed the European Society of Cardiology (ESC) methodology for the development of QIs. Key domains were identified by constructing a conceptual framework for the delivery of TAVI care. A list of candidate QIs were developed by conducting a systematic review of the literature. A modified Delphi method was then used to select the final set of QIs. Finally, we mapped the QIs to the EuroHeart Data Standards for TAVI to ascertain the extent to which the EuroHeart TAVI registry captures information to calculate the QIs. RESULTS: We formed an international group of experts in quality improvement and TAVI, including representatives from the European Association of Percutaneous Cardiovascular Interventions, the European Association of Cardiovascular Imaging and the Association of Cardiovascular Nursing & Allied Professions. In total, 27 QIs were selected across eight domains of TAVI care, comprising 22 main (81%) and five secondary (19%) QIs. Of these, 19/27 (70%) are now being utilised in the EuroHeart TAVI registry. CONCLUSION: We present the 2023 ESC QIs for TAVI, developed using a standard methodology and in collaboration with ESC Associations. The EuroHeart TAVI registry allows calculation of the majority of the QIs, which may be used for benchmarking care and quality improvement initiatives.

5.
Clin Res Cardiol ; 113(1): 86-93, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37391628

ABSTRACT

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic valve stenosis in elderly patients, but there is uncertainty on their long-term effectiveness. We aimed to assess the long-term outcome of patients undergoing TAVI with the Portico valve. METHODS: We retrospectively collected the data on patients in whom TAVI with Portico was attempted from 7 high-volume centres. Only patients theoretically eligible for 3 or more years of follow-up were included. Clinical outcomes, including death, stroke, myocardial infarction, reintervention for valve degeneration and hemodynamic valve performance were systematically assessed. RESULTS: A total of 803 patients were included, with 504 (62.8%) women, mean age of 82 years, median EuroSCORE II of 3.1%, and 386 (48.1%) subjects at low/moderate risk. The median follow-up was 3.0 years (3.0; 4.0). The composite of death, stroke, myocardial infarction, and reintervention for valve degeneration occurred in 37.5% (95% confidence interval: 34.1-40.9%), with all-cause death in 35.1% (31.8-38.4%), stroke in 3.4% (1.3-3.4%), myocardial infarction in 1.0% (0.3-1.5%), and reintervention for valve degeneration in 1.1% (0.6-2.1%). The mean aortic valve gradient at follow-up was 8.1 ± 4.6 mmHg, and at least moderate aortic regurgitation was present in 9.1% (6.7-12.3%). Independent predictors of major adverse events or death were: peripheral artery disease, chronic obstructive pulmonary disease, estimated glomerular filtration rate, atrial fibrillation, prior pacemaker implantation, EuroSCORE II, and reduced left ventricular ejection fraction (all p < 0.05). CONCLUSIONS: Portico use is associated with favorable long-term clinical outcomes. Clinical outcomes were largely impacted by baseline risk factors and surgical risk.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Myocardial Infarction , Stroke , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Retrospective Studies , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Aortic Valve Stenosis/surgery , Stroke/etiology
6.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37138103

ABSTRACT

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Treatment Outcome , Aortic Valve/surgery , Registries , Prosthesis Design
7.
Hellenic J Cardiol ; 2023 Sep 07.
Article in English | MEDLINE | ID: mdl-37689181

ABSTRACT

OBJECTIVE: Aortic stenosis and coronary artery disease (CAD) are frequently associated. The preprocedural evaluation and indications for treatment in patients undergoing transcatheter aortic valve intervention (TAVI) remain controversial. This study sought to 1) determine the prevalence and angiographic characteristics of CAD in TAVI candidates, along with revascularization patterns, and 2) to evaluate the impact of the presence and complexity of CAD, as well as angiography-guided percutaneous coronary intervention, on prognosis after TAVI. METHODS: Single-center retrospective study from a prospectively collected institutional registry that included all patients that underwent TAVI between 2009 and 2018 and pre TAVI coronary angiography (CA) in our institution in the context of pre-procedure work-up. A multivariate analysis was performed to determine the effect of CAD and PCI on 2-year mortality. RESULTS: A total of 379 patients were included: 55 patients (14.5%) presented with normal coronary arteries, 120 (31.6%) with non-obstructive CAD, and 204 (53.8%) with obstructive CAD (the mean SxS was 8.2). Ultimately, 110 patients (29%) underwent PCI. Two-year survival after TAVI was decreased in patients with complex coronary lesions (SS > 22), while it was not affected by the overall presence of non-obstructive CAD, obstructive CAD, residual SxS, or pre-TAVI PCI of angiographically significant lesions (OR 0.631, 95%CI 0.192-1.406). CONCLUSION: In our population, the overall presence and management of obstructive CAD did not appear to impact mortality at 2 years after TAVI. Survival was decreased in patients with baseline complex coronary anatomies.

8.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Article in English | MEDLINE | ID: mdl-37668097

ABSTRACT

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Retrospective Studies , Prosthesis Design , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects
9.
EuroIntervention ; 19(8): 634-651, 2023 Oct 23.
Article in English | MEDLINE | ID: mdl-37624587

ABSTRACT

Valvular heart disease (VHD) is one of the most frequent causes of heart failure (HF) and is associated with poor prognosis, particularly among patients with conservative management. The development and improvement of catheter-based VHD interventions have broadened the indications for transcatheter valve interventions from inoperable/high-risk patients to younger/lower-risk patients. Cardiogenic shock (CS) associated with severe VHD is a clinical condition with a very high risk of mortality for which surgical treatment is often deemed a prohibitive risk. Transcatheter valve interventions might be a promising alternative in this setting given that they are less invasive. However, supportive scientific evidence is scarce and often limited to small case series. Current guidelines on VHD do not contain specific recommendations on how to manage patients with both VHD and CS. The purpose of this clinical consensus statement, developed by a group of international experts invited by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) Scientific Documents and Initiatives Committee, is to perform a review of the available scientific evidence on the management of CS associated with left-sided VHD and to provide a rationale and practical approach for the application of transcatheter valve interventions in this specific clinical setting.

10.
Front Cardiovasc Med ; 10: 1227217, 2023.
Article in English | MEDLINE | ID: mdl-37645516

ABSTRACT

Background: A steep rise in the use of transcatheter aortic valve implantation (TAVI) for the management of symptomatic severe aortic stenosis occurred. Minimalist TAVI procedures and streamlined patient pathways within experienced Heart Valve Centres are designed to overcome the challenges of ever-increasing procedural volume. Aims: The 2022 European TAVI Pathway Survey aims to describe contemporary TAVI practice across Europe. Materials and methods: Between October and December 2022, TAVI operators from 32 European countries were invited to complete an online questionnaire regarding their current practice. Results: Responses were available from 147 TAVI centres in 26 countries. In 2021, the participating centres performed a total number of 27,223 TAVI procedures, with a mean of 185 TAVI cases per centre (median 138; IQR 77-194). Treatment strategies are usually (87%) discussed at a dedicated Heart Team meeting. Transfemoral TAVI is performed with local anaesthesia only (33%), with associated conscious sedation (60%), or under general anaesthesia (7%). Primary vascular access is percutaneous transfemoral (99%) with secondary radial access (52%). After uncomplicated TAVI, patients are transferred to a high-, medium-, or low-care unit in 28%, 52%, and 20% of cases, respectively. Time to discharge is day 1 (12%), day 2 (31%), day 3 (29%), or day 4 or more (28%). Conclusion: Reported adoption of minimalist TAVI techniques is common among European TAVI centres, but rates of next-day discharge remain low. This survey highlights the significant progress made in refining TAVI treatment and pathways in recent years and identifies possible areas for further improvement.

11.
Clin Res Cardiol ; 112(9): 1322-1330, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37337010

ABSTRACT

BACKGROUND AND AIM: Parenteral anticoagulation is recommended for all patients presenting with ST-segment elevation myocardial infarction (STEMI) during primary percutaneous coronary intervention (PPCI). Whether upstream anticoagulation improves clinical outcomes is not well established. We conducted a systematic review and meta-analysis of contemporary evidence on parenteral anticoagulation timing for STEMI patients. METHODS: We performed a systematic search of electronic databases (PubMed, CENTRAL, and Scopus) until December 2022. Studies were eligible if they (a) compared upstream anticoagulation with administration at the catheterization laboratory and (b) enrolled patients with STEMI undergoing PPCI. Efficacy outcomes included in-hospital or 30-day mortality, in-hospital cardiogenic shock (CS), and TIMI flow grade pre- and post-PPCI. Safety outcome was defined as in-hospital or 30-day major bleeding. RESULTS: Overall, seven studies were included (all observational), with a total of 69,403 patients. Upstream anticoagulation was associated with a significant reduction in the incidence of in-hospital or 30-day all-cause mortality (OR 0.61; 95% CI 0.45-0.81; p < 0.001) and in-hospital CS (OR 0.68; 95% CI 0.58-0.81; p < 0.001) and with an increase in spontaneous reperfusion (pre-PPCI TIMI > 0: OR 1.46; 95% CI 1.35-1.57; p < 0.001). Pretreatment was not associated with an increase in major bleeding (OR 1.02; 95% CI 0.70-1.48; p = 0.930). CONCLUSIONS: Upstream anticoagulation was associated with a significantly lower risk of 30-day all-cause mortality, incidence of in-hospital CS, and improved reperfusion of the infarct-related artery (IRA). These findings were not accompanied by an increased risk of major bleeding, suggesting an overall clinical benefit of early anticoagulation in STEMI. These results require confirmation in a dedicated randomized clinical trial.


Subject(s)
Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , ST Elevation Myocardial Infarction/diagnosis , ST Elevation Myocardial Infarction/therapy , ST Elevation Myocardial Infarction/etiology , Percutaneous Coronary Intervention/methods , Hemorrhage/chemically induced , Catheterization , Anticoagulants/therapeutic use , Treatment Outcome , Randomized Controlled Trials as Topic
12.
Rev Port Cardiol ; 42(9): 787-793, 2023 09.
Article in English, Portuguese | MEDLINE | ID: mdl-37257584

ABSTRACT

INTRODUCTION AND OBJECTIVES: Randomized controlled trials comparing stress cardiac magnetic resonance (CMR) and single-photon emission computed tomography (SPECT) suggest similar diagnostic accuracy for detecting obstructive coronary artery disease (CAD). There are few data on whether this remains true in routine clinical practice. The aim of this study was to assess clinical and angiographic characteristics of patients undergoing invasive coronary angiography (ICA) after stress CMR or SPECT, and to compare their positive predictive value with published results from the CE-MARC trial. METHODS: In this retrospective tertiary-center analysis, we included 429 patients undergoing ICA after a positive stress CMR or positive SPECT performed within the previous 12 months. Obstructive CAD was defined as any coronary artery stenosis ≥50% in a vessel compatible with the ischemic territory on stress testing. RESULTS: Of the total 429 patients, 356 (83%) were referred after a positive SPECT, and 73 (17%) after a positive stress CMR. Patients did not differ according to age, cardiovascular risk factors, previous revascularization or left ventricular dysfunction, but patients with SPECT were more frequently male (p=0.046). The prevalence of obstructive CAD was similar in patients with positive SPECT vs. positive stress CMR (76.1% vs. 80.8%, respectively, p=0.385). The positive predictive values of both techniques were similar to those reported in the CE-MARC trial. CONCLUSION: In this tertiary center analysis, stress CMR and SPECT showed similar positive predictive values, comparable to those reported in the CE-MARC trial. This finding supports the emerging adoption of CMR in clinical practice for the diagnosis and management of CAD.


Subject(s)
Coronary Artery Disease , Myocardial Perfusion Imaging , Humans , Male , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Myocardial Perfusion Imaging/methods , Retrospective Studies , Tomography, Emission-Computed, Single-Photon/methods
13.
EuroIntervention ; 19(6): 502-511, 2023 Aug 21.
Article in English | MEDLINE | ID: mdl-37203860

ABSTRACT

BACKGROUND: Prospective data about transcatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BAV) patients are limited. AIMS: We aimed to evaluate the clinical impact of the Evolut PRO and R (34 mm) self-expanding prostheses in BAV patients and explore the impact of different computed tomography (CT) sizing algorithms in a prospective registry. METHODS: A total of 149 bicuspid patients were treated in 14 countries. The primary endpoint was the intended valve performance at 30 days. Secondary endpoints were 30-day and 1-year mortality, severe patient-prosthesis mismatch (PPM) and the ellipticity index at 30 days. All study endpoints were adjudicated according to Valve Academic Research Consortium 3 criteria. RESULTS: The mean Society of Thoracic Surgeons score was 2.6% (1.7-4.2). Type I L-R BAV was observed in 72.5% of the patients. Evolut valve sizes 29 and 34 mm were utilised in 49.0% and 36.9% of the cases, respectively. The 30-day cardiac death rate was 2.6%; the 1-year cardiac death rate was 11.0%. Valve performance at 30 days was observed in 142/149 (95.3%) patients. The mean aortic valve area post-TAVI was 2.1 (1.8-2.6) cm2, and the mean aortic gradient was 7.2 (5.4-9.5) mmHg. No patient had more than moderate aortic regurgitation at 30 days. PPM was observed in 13/143 (9.1%) surviving patients and was severe in 2 patients (1.6%). Valve function was maintained at 1 year. The mean ellipticity index remained 1.3 (interquartile range 1.2-1.4). Overall, 30-day and 1-year clinical and echocardiography outcomes were similar between the two sizing strategies. CONCLUSIONS: BIVOLUTX demonstrated a favourable bioprosthetic valve performance and good clinical outcomes after TAVI with the Evolut platform in patients with bicuspid aortic stenosis. No impact from the sizing methodology could be identified.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Heart Valve Prosthesis , Mitral Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Bicuspid Aortic Valve Disease/etiology , Bicuspid Aortic Valve Disease/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Constriction, Pathologic , Treatment Outcome , Prosthesis Design , Prospective Studies , Heart Valve Diseases/surgery , Mitral Valve Stenosis/surgery , Registries , Death
14.
EuroIntervention ; 18(17): 1418-1427, 2023 Apr 24.
Article in English | MEDLINE | ID: mdl-36880333

ABSTRACT

BACKGROUND: Initial data about the performance of the new-generation SAPIEN 3 Ultra (S3U) valve are highly promising. However, evidence about the longer-term performance and safety of the S3U is scarce. AIMS: We aimed to investigate the 1-year clinical and echocardiographic outcomes of transcatheter aortic valve implantation (TAVI) using the S3U compared with its predecessor, the SAPIEN 3 valve (S3). METHODS: The SAPIEN 3 Ultra registry included consecutive patients who underwent transfemoral TAVI at 12 European centres with the S3U or S3 between October 2016 and December 2020. One-to-one propensity score (PS) matching was performed to account for differences in baseline characteristics. The primary outcomes of interest were all-cause death and the composite of all-cause death, disabling stroke and hospitalisation for heart failure at 1 year. RESULTS: The overall study cohort encompassed 1,692 patients treated with either the S3U (n=519) or S3 (n=1,173). The PS-matched population had a total of 992 patients (496 per group). At 1 year, the rate of death from any cause was 4.9% in the S3U group and 6.3% in the S3 group (p=0.743). Similarly, there were no significant differences in the rates of the primary composite outcome (9.5% in the S3 group and 6.6% in the S3U group; p=0.162). The S3U was associated with lower rates of mild paravalvular leak (PVL) compared with the S3 (odds ratio 0.63, 95% confidence interval: 0.44 to 0.88; p<0.01). No significant differences in transprosthetic gradients were observed between the two groups. CONCLUSIONS: Compared with the S3, the S3U transcatheter heart valve was associated with similar 1-year clinical outcomes but reduced rates of mild PVL.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Treatment Outcome , Registries , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Prosthesis Design
15.
Int J Cardiol ; 379: 16-23, 2023 05 15.
Article in English | MEDLINE | ID: mdl-36863420

ABSTRACT

BACKGROUND: Sex-specific characteristics in patients with aortic stenosis and small annuli undergoing transcatheter aortic valve implantation (TAVI) might affect clinical outcomes and hemodynamics. METHODS: TAVI-SMALL 2 international retrospective registry included 1378 patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area < 400 mm2) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Women (n = 1233) were compared with men (n = 145). One-to-one propensity score (PS) matching resulted in 99 pairs. Primary endpoint was incidence of all-cause mortality. Incidence of pre-discharge severe prosthesis-patient mismatch (PPM) and its association with all-cause mortality were investigated. Binary logistic and Cox regression were performed to adjust the treatment effect for PS quintiles. RESULTS: Incidence of all-cause mortality at a median follow-up of 377 days did not differ between sex in the overall (10.3 vs. 9.8%, p = 0.842) and PS-matched (8.5 vs. 10.9%, p = 0.586) populations. After PS matching, pre-discharge severe PPM was numerically higher in women vs. men (10.2 vs. 4.3%), even though no evidence of a difference was found (p = 0.275). Within the overall population, women with severe PPM suffered a higher incidence of all-cause mortality when compared to those with less than moderate PPM (log-rank p = 0.024) and less than severe PPM (p = 0.027). CONCLUSIONS: No difference in all-cause mortality at medium-term follow-up was observed between women and men with aortic stenosis and small annuli undergoing TAVI. Incidence of pre-discharge severe PPM was numerically higher in women than men, and it was associated with increased all-cause mortality in women.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Male , Humans , Female , Aortic Valve/surgery , Retrospective Studies , Propensity Score , Treatment Outcome , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Risk Factors
16.
EuroIntervention ; 19(3): 256-266, 2023 Jun 19.
Article in English | MEDLINE | ID: mdl-36950893

ABSTRACT

BACKGROUND: Treatment of aortic stenosis in patients with small annuli is challenging and can result in prosthesis-patient mismatch (PPM). AIMS: We aimed to compare the forward flow haemodynamics and clinical outcomes of contemporary transcatheter valves in patients with small annuli. METHODS: The TAVI-SMALL 2 international retrospective registry included 1,378 patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2) treated with transfemoral self-expanding (SEV; n=1,092) and balloon-expandable valves (BEV; n=286) in 16 high-volume centres between 2011 and 2020. Analyses comparing SEV versus BEV and supra-annular (SAV; n=920) versus intra-annular valves (IAV; n=458) included inverse probability of treatment weighting (IPTW). The primary endpoints were the predischarge mean aortic gradient and incidence of severe PPM. The secondary endpoint was the incidence of more than mild paravalvular leak (PVL). RESULTS: The predischarge mean aortic gradient was lower after SAV versus IAV (7.8±3.9 vs 12.0±5.1; p<0.001) and SEV versus BEV implantation (8.0±4.1 vs 13.6±4.7; p<0.001). Severe PPM was more common with IAV and BEV when compared to SAV and SEV implantation, respectively, (8.8% vs 3.6%; p=0.007 and 8.7% vs 4.6%; p=0.041). At multivariable logistic regression weighted by IPTW, SAV protected from severe PPM regardless of its definition. More than mild PVL occurred more often with SEV versus BEV (11.6% vs 2.6%; p<0.001). CONCLUSIONS: In small aortic annuli, implantation of SAV and SEV was associated with a more favourable forward haemodynamic profile than after IAV and BEV implantation, respectively. More than mild PVL was more common after SEV than BEV implantation.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Prosthesis Design , Aortic Valve Stenosis/surgery , Registries , Treatment Outcome
17.
EuroIntervention ; 19(1): 37-52, 2023 May 15.
Article in English | MEDLINE | ID: mdl-36811935

ABSTRACT

Significant coronary artery disease (CAD) is a frequent finding in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI), and the management of these two conditions becomes of particular importance with the extension of the procedure to younger and lower-risk patients. Yet, the preprocedural diagnostic evaluation and the indications for treatment of significant CAD in TAVI candidates remain a matter of debate. In this clinical consensus statement, a group of experts from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) in collaboration with the European Society of Cardiology (ESC) Working Group on Cardiovascular Surgery aims to review the available evidence on the topic and proposes a rationale for the diagnostic evaluation and indications for percutaneous revascularisation of CAD in patients with severe aortic stenosis undergoing transcatheter treatment. Moreover, it also focuses on commissural alignment of transcatheter heart valves and coronary re-access after TAVI and redo-TAVI.


Subject(s)
Aortic Valve Stenosis , Cardiology , Coronary Artery Disease , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Coronary Artery Disease/surgery , Coronary Artery Disease/etiology , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Treatment Outcome
18.
Rev. esp. cardiol. (Ed. impr.) ; 76(1): 25-31, Ene-Feb. 2023. tab, graf, ilus
Article in Spanish | IBECS | ID: ibc-214450

ABSTRACT

Introducción y objetivos: PASCAL es un dispositivo novedoso de terapia mitral transcatéter basada en la reparación borde a borde. Algunas características únicas podrían tener un impacto relevante en sus resultados. Hay pocos datos sobre los resultados clínicos en registros de la vida real. El objetivo de este estudio es publicar la experiencia ibérica precoz (centros de España y Portugal) del sistema PASCAL. Métodos: Se incluyó prospectivamente a los pacientes tratados consecutivamente de insuficiencia mitral (IM) grave sintomática en 10 centros. El objetivo primario de eficacia fue el éxito técnico y el grado de regurgitación al alta. El objetivo primario de seguridad fueron los eventos adversos mayores (MAE) a 30 días. Resultados: Se incluyó a 68 pacientes (75 [68-81] años, 38% mujeres, EuroSCORE II 4,5%). La IM fue degenerativa en el 25% de los casos, funcional en el 65%, y mixta en el 10%. El 71% de pacientes estaban en clase funcional New York Heart Association (NYHA)≥III. El éxito técnico fue del 96% y la captura independiente se usó en el 73% de los procedimientos. Toda la población tratada obtuvo una IM al alta≤2+ (100%) y no hubo muertes intrahospitalarias. A los 30 días, los MAE fueron del 5,9%, la mortalidad global del 1,6%, el 98% estuvieron en clase NYHA≤II y el 95% tuvieron IM≤2+ (p <0,001). Conclusiones: El sistema PASCAL de terapia transcatéter mitral fue efectivo y seguro, con elevado éxito técnico y baja tasa de MAE. A los 30 días la IM se redujo significativamente, y hubo una mejoría en la clase funcional.(AU)


Introduction and objectives: The PASCAL system is a novel device for transcatheter mitral valve repair based on the edge-to-edge concept. The unique features of this device might have a relevant impact on the repair outcomes. There are few data on clinical outcomes in real-life registries. The aim of this study was to report the early Iberian experience (Spain and Portugal) of the PASCAL system. Methods: Procedural and 30-day outcomes were investigated in consecutive patients with symptomatic severe mitral regurgitation (MR) treated with the PASCAL system at 10 centers. Primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE) at 30 days. Results: We included 68 patients (age, 75 [68-81] years; 38% women; EuroSCORE II 4.5%). MR etiology was degenerative in 25%, functional in 65%, and mixed in 10%. A total of 71% of patients were in New York Heart Association (NYHA) functional class≥III. Technical success was achieved in 96% and independent capture was used in 73% of procedures. In the treated population, MR at discharge was≤2+ in 100%, with no in-hospital deaths. At 30 days, the MAE rate was 5.9%, the all-cause mortality rate was 1.6%, 98% were in NYHA functional class≤II, and 95% had MR≤2+ (P<.001). Conclusions: Transcatheter mitral valve repair with the PASCAL system was safe and effective, with high procedural success and low rates of MAE. At 30 days, MR was significantly reduced, with a significant improvement in functional status.(AU)


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Mitral Valve Insufficiency , Long Term Adverse Effects , Equipment and Supplies , Heart Valve Diseases , Cardiology , Spain , Cardiovascular Diseases , Portugal
19.
Am Heart J ; 256: 139-147, 2023 02.
Article in English | MEDLINE | ID: mdl-36410441

ABSTRACT

BACKGROUND: Surgical aortic valve bioprostheses may degenerate over time and require redo intervention. Transcatheter aortic valve replacement (TAVR) is a less invasive alternative to redo surgery. The BAlloon Expandable vs. SElf Expanding Transcatheter VaLve for Degenerated BioprosthesIs (BASELINE) trial was designed to compare the performance of the balloon-expandable SAPIEN-3 Ultra and the self-expanding EVOLUT PRO+ valve systems in symptomatic patients with a failing surgical bioprosthesis. METHODS: The BASELINE trial is an investigator-initiated, non-funded, prospective, randomized, open-label, superiority trial enrolling a total of 440 patients in up to 50 sites in 12 countries in Europe and North-America. The primary endpoint is device success at 30-days defined by the Valve Academic Research Consortium-3 Criteria as the composite of technical success, freedom from mortality, freedom for surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication with an intended performance of the valve (mean gradient <20 mmHg and less than moderate aortic regurgitation). The co-primary endpoint at 1 year is defined as the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems. Independent Core Laboratories will conduct uniform analyses of echocardiography (pre-, post-, 1-year post-procedure), multi-sliced computed tomography (pre-, and if available post-procedure) and cine-fluoroscopy studies. CONCLUSIONS: The BASELINE trial is a head-to-head comparative trial investigating the 2 most used contemporary transcatheter heart valves for the treatment of a failing surgical aortic bioprosthesis. (ClinicalTrials.gov number NCT04843072).


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Prospective Studies , Prosthesis Design , Treatment Outcome , Transcatheter Aortic Valve Replacement/methods
20.
Eur Heart J Case Rep ; 7(1): ytac469, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36582595

ABSTRACT

Background: Transcatheter aortic valve implantation (TAVI) has rapidly evolved and changed the field of structural cardiovascular intervention. Its advances lead to a marked reduction in the risk of complications and improved outcomes. However, TAVI is still associated with potential serious complications. Case summary: A 73-year-old man with severe aortic stenosis underwent TAVI using a 34-mm self-expanding aortic bioprosthesis. After valve deployment, the patient rapidly progressed to cardiac arrest. Acute left main occlusion, due to high valve implantation, was promptly recognized and advanced life support immediately initiated. Concomitantly, the valve was successfully retrieved toward the ascending aorta using the snare technique, resulting in immediate restoration of flow and successful cardiopulmonary resuscitation. Subsequently, a 29-mm balloon-expandable aortic bioprosthesis was uneventfully implanted. After TAVI, the patient had a remarkable clinical evolution and was discharged home at hospitalization day five without relevant electrocardiographic nor echocardiographic disturbances. At six-month follow-up, the patient remains asymptomatic and transthoracic echocardiography revealed a normofunctional aortic bioprosthesis with preserved left ventricular ejection fraction. Discussion: Acute coronary occlusion is a rare and life-threating complication of TAVI that may be prevented with accurate procedure planning. Pre-procedural computed tomography angiography is essential for a comprehensive patient evaluation, allowing appropriate valve selection, a key factor for successful management. Self-expandable valve retrieval with snare technique can be an appropriate strategy for the management of this complication. This case highlights the importance of performing these procedures in highly experienced centres and with fully equipped catheterization laboratories to allow timely interventions when facing unexpected events.

SELECTION OF CITATIONS
SEARCH DETAIL
...