1.
Clin Chem ; 70(4): 669-679, 2024 04 03.
Article in English | MEDLINE | ID: mdl-38385453

ABSTRACT

BACKGROUND: The harmonization status of most tumor markers (TMs) is unknown. We report a feasibility study performed to determine whether external quality assessment (EQA) programs can be used to obtain insights into the current harmonization status of the tumor markers α-fetoprotein (AFP), prostate specific antigen (PSA), carcinoembryonic antigen (CEA), cancer antigen (CA)125, CA15-3 and CA19-9. METHODS: EQA sample results provided by 6 EQA providers (INSTAND [Germany], Korean Association of External Quality Assessment Service [KEQAS, South Korea], National Center for Clinical Laboratories [NCCL, China], United Kingdom National External Quality Assessment Service [UK NEQAS, United Kingdom], Stichting Kwaliteitsbewaking Medische Laboratoriumdiagnostiek [SKML, the Netherlands], and the Royal College of Pathologists of Australasia Quality Assurance Programs [RCPAQAP, Australia]) between 2020 and 2021 were used. The consensus means, calculated from the measurement procedures present in all EQA programs (Abbott Alinity, Beckman Coulter DxI, Roche Cobas, and Siemens Atellica), was used as reference values. Per measurement procedure, the relative difference between consensus mean for each EQA sample and the mean of all patient-pool-based EQA samples were calculated and compared to minimum, desirable, and optimal allowable bias criteria based on biological variation. RESULTS: Between 19040 (CA15-3) and 25398 (PSA) individual results and 56 (PSA) to 76 (AFP) unique EQA samples were included in the final analysis. The mean differences with the consensus mean of patient-pool-based EQA samples for all measurement procedures were within the optimum bias criterion for AFP, the desirable bias for PSA, and the minimum bias criterion for CEA. However, CEA results <8 µg/L exceeded the minimum bias criterion. For CA125, CA15-3, and CA19-9, the harmonization status was outside the minimum bias criterion, with systematic differences identified. CONCLUSIONS: This study provides relevant information about the current harmonization status of 6 tumor markers. A pilot harmonization investigation for CEA, CA125, CA15-3, and CA19-9 would be desirable.


Subject(s)
Biomarkers, Tumor , Carcinoembryonic Antigen , Male , Humans , alpha-Fetoproteins/analysis , Prostate-Specific Antigen , CA-19-9 Antigen , Feasibility Studies , Mucin-1 , CA-125 Antigen
2.
Clin Chem Lab Med ; 62(6): 1158-1166, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38353154

ABSTRACT

OBJECTIVES: To accurately evaluate non-ST-elevated acute cardiac syndrome (NSTE-ACS), the quality of high-sensitive cardiac troponin (hs-cTn) assays is of vital importance. The 2020 revision of the NSTE-ACS guideline includes clinical decision-limits (CDL's) to both rule-in and rule-out NSTE-ACS for most commercially available platforms, providing both 0/1 h and 0/2 h delta limits. Our study evaluated whether laboratories are able to meet the analytical performance specifications for imprecision (APS) for hs-cTnT. METHODS: Results from external quality assurance (EQA) in commutable samples were used to evaluate the current and historic performance of analyzers. The performance of analyzers that either passed or failed to comply with 0/1 h-APS were used on a real-world dataset of first hs-cTnT-values to simulate 10.000 samples of t=0, t=1 and t=2 h values with multiple delta's for all relevant CDL's. We compared the simulated values to the input values to obtain the percentage of aberrant results simulated. RESULTS: The majority of analyzers complies with APS for rule-in in 2022 (0/1 h: 90.4 % and 0/2 h: 100 %), compliance for the 0/1 h rule-out is still far from optimal (0/1 h: 30.7 %, 0/2 h: 75.4 %), with improving compliance over the past years (rule-in p=<0.0001, rule-out p=0.011, χ2). Whilst 0/1 h-APS-passing analyzers have a minute risk to falsely rule-out patients whom should be ruled-in (0.0001 %), failing performance increases this risk to 2.1 % upon using 0/1 h CDL's. Here, adopting 0/2 h CDL's is favorable (0.01 %). CONCLUSIONS: Laboratories that fail to meet hs-cTnT 0/1 h-APS should improve their performance to the required and achievable level. Until performance is reached clinics should adopt the 0/2 h CDL's.


Subject(s)
Troponin T , Humans , Troponin T/blood , Troponin T/analysis , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/blood , Quality Control , Quality Assurance, Health Care , Practice Guidelines as Topic
3.
Clin Chem Lab Med ; 2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38353157

ABSTRACT

ISO 15189 requires laboratories to estimate the uncertainty of their quantitative measurements and to maintain them within relevant performance specifications. Furthermore, it refers to ISO TS 20914 for instructions on how to estimate the uncertainty and what to take into consideration when communicating uncertainty of measurement with requesting clinicians. These instructions include the responsibility of laboratories to verify that bias is not larger than medically significant. If estimated to be larger than acceptable, such bias first needs to be eliminated or (temporarily) corrected for. In the latter case, the uncertainty of such correction becomes part of the estimation of the total measurement uncertainty. If small enough to be acceptable, bias becomes part of the long term within laboratory random variation. Sources of possible bias are (not limited to) changes in reagent or calibrator lot variation or calibration itself. In this paper we clarify how the rationale and mathematics from an EFLM WG ISO/A position paper on allowable between reagent lot variation can be applied to calculate whether bias can be accepted to become part of long-term imprecision. The central point of this rationale is to prevent the risk that requesting clinicians confuse changes in bias with changes in the steady state of their patients.

4.
EClinicalMedicine ; 68: 102414, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38299045

ABSTRACT

Background: Chronic kidney disease (CKD) is often detected late, leading to substantial health loss and high treatment costs. Screening the general population for albuminuria identifies individuals at high risk of kidney events and cardiovascular disease (CVD) who may benefit from early start of preventive interventions. Previous studies on the cost-effectiveness of albuminuria population screening were inconclusive, but were based on survey or cohort data rather than an implementation study, modelled screening as performed by general practitioners rather than home-based screening, and often included only benefits with respect to kidney events. We evaluated the cost-effectiveness of home-based general population screening for increased albuminuria based on real-world data obtained from a prospective implementation study taking into account prevention of CKD as well as CVD events. Methods: We developed an individual-level simulation model to compare home-based screening using a urine collection device with usual care (no home-based screening) in individuals of the general population aged 45-80, based on the THOMAS study (Towards HOMe-based Albuminuria Screening). Cost-effectiveness was assessed from the Dutch healthcare perspective with a lifetime horizon. The costs of the screening process and benefits of preventing CKD progression (dialysis and kidney transplantation) and CVD events (non-fatal myocardial infarction, non-fatal stroke, fatal CVD event) were reflected. Albuminuria detection led to treatment of identified risk factors. The model subsequently simulated CKD progression, the occurrence of CVD events, and death. The risks of experiencing CVD events were calculated using the SCORE2 CKD risk prediction model and individual-level data from the THOMAS study. Relative treatment effectiveness, quality of life scores, resource use, and cost inputs were obtained from literature. Model outcomes were the number of CKD and CVD-related events, total costs, quality-adjusted life years (QALYs), and the incremental cost-effectiveness ratio (ICER) per QALY gained by screening versus usual care. All results were obtained through probabilistic analysis. Findings: The absolute difference between screening versus usual care in lifetime probability of dialysis, kidney transplantation, non-fatal myocardial infarction, non-fatal stroke, and fatal CVD events were 0.2%, 0.05%, 0.6%, 0.6%, and 0.2%, respectively. This led to relative decreases compared to usual care in lifetime incidence of these events of 10.7%, 11.1%, 5.1%, 4.1%, and 1.6%, respectively. The incremental costs and QALYs of screening were €1607 and 0.17 QALY, respectively, which led to a corresponding ICER of €9225/QALY. The probability of screening being cost-effective for the Dutch willingness-to-pay threshold for preventive population screening of €20,000/QALY was 95.0%. Implementing the screening in the subgroup of 45-64 years old reduced the ICER (€7946/QALY), whereas implementing screening in the subgroup of 65-80 years old increased the ICER (€10,310/QALY). A scenario analysis assuming treatment optimization in all individuals with newly diagnosed risk factors or known risk factors not within target range reduced the ICER to €7083/QALY, resulting from the incremental costs and QALY gain of €2145 and 0.30, respectively. Interpretation: Home-based screening for increased albuminuria to prevent CVD and CKD events is likely cost-effective. More health benefits can be obtained by screening younger individuals and better optimization of care in individuals identified with newly diagnosed or known risk factors outside target range. Funding: Dutch Kidney Foundation, Top Sector Life Sciences & Health of the Dutch Ministry of Economic Affairs.

5.
J Cardiothorac Vasc Anesth ; 38(3): 667-674, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38233243

ABSTRACT

OBJECTIVES: To investigate the incidence of preoperative abnormal iron status and its association with packed red blood cell (PRBC) transfusion, postoperative major complications, and new onset of clinically significant disability in patients undergoing elective cardiac surgery. DESIGN: A prospective, observational multicenter cohort study. SETTING: Three cardiac surgical centers in the Netherlands between 2019 and 2021. Recruitment was on hold between March and May 2020 due to COVID-19. PATIENTS: A total of 427 patients aged 60 years and older who underwent elective on-pump cardiac surgery. MEASUREMENTS AND MAIN RESULTS: The primary endpoint was a 30-day PRBC transfusion. Secondary endpoints were postoperative major complications within 30 days (eg, acute kidney injury, sepsis), and new onset of clinically significant disability within 120 days of surgery. Iron status was evaluated before surgery. Abnormal iron status was present in 45.2% of patients (n = 193), and most frequently the result of iron deficiency (27.4%, n = 117). An abnormal iron status was not associated with PRBC transfusion (adjusted relative risk [ARR] 1.2; 95% CI 0.9-1.8: p = 0.227) or new onset of clinically significant disability (ARR 2.0; 95% CI 0.9-4.6: p = 0.098). However, the risk of postoperative major complications was increased in patients with an abnormal iron status (ARR 1.7; 95% CI 1.1-2.5: p = 0.012). CONCLUSIONS: An abnormal iron status before elective cardiac surgery was associated with an increased risk of postoperative major complications but not with PRBC transfusion or a new onset of clinically significant disability.


Subject(s)
Cardiac Surgical Procedures , Iron , Humans , Middle Aged , Aged , Prospective Studies , Cohort Studies , Cardiac Surgical Procedures/adverse effects , Elective Surgical Procedures/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology
6.
Clin Chem Lab Med ; 62(4): 597-607, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-37978287

ABSTRACT

OBJECTIVES: According to ISO 15189:2022, analytical performance specifications (APS) should relate to intended clinical use and impact on patient care. Therefore, we aimed to develop a web application for laboratory professionals to calculate APS based on a simulation of the impact of measurement uncertainty (MU) on the outcome using the chosen decision limits, agreement thresholds, and data of the population of interest. METHODS: We developed the "APS Calculator" allowing users to upload and select data of concern, specify decision limits and agreement thresholds, and conduct simulations to determine APS for MU. The simulation involved categorizing original measurand concentrations, generating measured (simulated) results by introducing different degrees of MU, and recategorizing measured concentrations based on clinical decision limits and acceptable clinical misclassification rates. The agreements between original and simulated result categories were assessed, and values that met or exceeded user-specified agreement thresholds that set goals for the between-category agreement were considered acceptable. The application generates contour plots of agreement rates and corresponding MU values. We tested the application using National Health and Nutrition Examination Survey data, with decision limits from relevant guidelines. RESULTS: We determined APS for MU of six measurands (blood total hemoglobin, plasma fasting glucose, serum total and high-density lipoprotein cholesterol, triglycerides, and total folate) to demonstrate the potential of the application to generate APS. CONCLUSIONS: The developed data-driven web application offers a flexible tool for laboratory professionals to calculate APS for MU using their chosen decision limits and agreement thresholds, and the data of the population of interest.


Subject(s)
Clinical Laboratory Techniques , Laboratories , Humans , Uncertainty , Clinical Laboratory Techniques/methods , Nutrition Surveys , Fasting
7.
Clin Chem Lab Med ; 2023 Nov 28.
Article in English | MEDLINE | ID: mdl-38008748

ABSTRACT

OBJECTIVES: This paper evaluates 16 year results of the Allergy EQA program shared by EQA organisers in Belgium, Finland, Portugal, and The Netherlands. METHODS: The performance of Thermo Fisher and Siemens user groups (in terms of concordance between both groups, between laboratory CV, prevalence of clinically significant errors) and suitability of samples (stability and validity of dilution of patient samples) are evaluated using data of 192 samples in the EQA programs from 2007 to 2022. Measurands covered are total IgE, screens and mixes, specific IgE extracts and allergen components. RESULTS: There is perfect (53 %), acceptable (40 %) and poor (6 %) concordance between both method groups. In case of poor concordance the best fit with clinical data is seen for Thermo Fisher (56 %) and Siemens (26 %) respectively. The between laboratory CV evolves from 7.8 to 6.6 % (Thermo Fisher) and 7.3 to 7.7 % (Siemens). The prevalence of blunders by individual laboratories is stable for Siemens (0.4 %) and drops from 0.4 to 0.2 % for Thermo Fisher users. For IgE, the between year CV of the mean of both user groups is 1 %, and a fifteen-fold dilution of a patient sample has an impact of 2 and 4 % on the recovery of Thermo Fisher and Siemens user groups. CONCLUSIONS: The analytical performance of Thermo Fisher is slightly better than that of Siemens users but the clinical impact of this difference is limited. Stability of the sample and the low impact of dilution on the recovery of measurands demonstrates the suitability for purpose of the EQA program.

8.
Lancet ; 402(10407): 1052-1064, 2023 09 23.
Article in English | MEDLINE | ID: mdl-37597522

ABSTRACT

BACKGROUND: Chronic kidney disease (CKD) has a rising global prevalence and is expected to become the fifth leading cause of death by 2030. Increased albuminuria defines the early stages of CKD and is among the strongest risk factors for progressive CKD and cardiovascular disease. The value of population screening for albuminuria to detect CKD in an early phase has yet to be studied. We aimed to evaluate the effectiveness of two home-based albuminuria population screening methods. METHODS: Towards Home-based Albuminuria Screening (THOMAS) was a prospective, randomised, open-label implementation study that invited Dutch adults aged 45-80 years for albuminuria screening. Individuals were randomly assigned (1:1) to screening by applying either a urine collection device (UCD) that was sent by post to a central laboratory for measurement of the albumin-to-creatinine ratio (ACR) by immunoturbidimetry or to screening via a smartphone application that measures the ACR with a dipstick method at home. Randomisation was done with a four-block method via a web-based system and was stratified by age, sex, and socioeconomic status. If two or more individuals per household were invited to participate, these individuals were randomly assigned to the same group. In case of confirmed increased albuminuria at home, participants were invited for an elaborate screening in a regional hospital (Amphia Hospital, Breda, Netherlands) for CKD and cardiovascular risk factors. When abnormalities were found, participants were referred to their general practitioner for treatment. The primary outcomes were the participation rate and yield of the home-based screening and elaborate screening. Participation rate was assessed in the intention-to-screen population (ie, all participants who were invited for the home-based screening or elaborate screening). Yield was assessed in the per-protocol population (ie, all individuals who participated in the home-based screening or elaborate screening). An exploratory analysis assessed the sensitivity and specificity of both home-based screening methods. To this end, an additional quantitative ACR test was performed among people participating in the elaborate screening, and a substudy was performed among participants with a first negative home-based screening test, who were invited for an additional test. The study is registered with ClinicalTrials.gov, NCT04295889. FINDINGS: 15 074 participants were enrolled between Nov 14, 2019, and March 19, 2021. 7552 (50·1%) were randomly assigned to home-based albuminuria screening by the UCD method and 7522 (49·9%) were assigned to albuminuria screening by the smartphone application method. The participation rate of the home-based screening was 4484 (59·4% [95% CI 58·3-60·5]) of the 7552 invited individuals for the UCD method and 3336 (44·3% [43·2-45·5]) of 7522 invited individuals for the smartphone application method (p<0·0001). Increased ACR was confirmed by home-based testing in 150 (3·3% [95% CI 2·9-3·9]) of 4484 individuals for the UCD method and 171 (5·1% [4·4-5·9]) of 3336 indivduals for the smartphone application method. 124 (82·7% [95% CI 75·8-87·9]) of 150 individuals assigned to the UCD method and 142 (83·0% [76·7-87·9]) of 171 participants assigned to the smartphone application method attended the elaborate screening. Sensitivity to detect increased ACR was 96·6% (95% CI 91·5-99·1) for the UCD method and 98·1% (89·9-99·9) for the smartphone application method, and specificity was 97·3% (94·7-98·8) for the UCD method and 67·9% (62·0-73·3) for the smartphone application method, indicating that the test characteristics of only the UCD method were sufficient for screening. Albuminuria, hypertension, hypercholesterolaemia, and decreased kidney function were newly diagnosed in 77 (62·1%), 44 (35·5%), 30 (24·2%), and 27 (21·8%) of 124 participants for the UCD method, respectively. Of the 124 participants assigned to the UCD method who completed elaborate screening, 111 (89·5%) were referred to their general practitioner for treatment because of newly diagnosed CKD or cardiovascular disease risk factors or known risk factors outside the target range. INTERPRETATION: Home-based screening of the general population for increased ACR using a UCD had a high participation rate and correctly identified individuals with increased albuminuria and yet unknown or known but outside target range CKD and cardiovascular risk factors. By contrast, the smartphone application method had a lower at-home participation rate than the UCD method and the test specificity was too low to accurately assess individuals for risk factors during the elaborate screening. The UCD screening strategy could allow for an early start of treatment to prevent progressive kidney function loss and cardiovascular disease in patients with CKD. FUNDING: Dutch Kidney Foundation, Top Sector Life Sciences & Health of the Dutch Ministry of Economic Affairs.


Subject(s)
Cardiovascular Diseases , Renal Insufficiency, Chronic , Humans , Albuminuria/diagnosis , Cardiovascular Diseases/epidemiology , Creatinine , Netherlands/epidemiology , Prospective Studies , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/epidemiology , Middle Aged , Aged , Aged, 80 and over
9.
Clin Chem Lab Med ; 61(12): 2167-2177, 2023 11 27.
Article in English | MEDLINE | ID: mdl-37401696

ABSTRACT

OBJECTIVES: Measurement of plasma albumin is pivotal for clinical decision-making in patients with chronic kidney disease (CKD). Routinely used methods as bromocresol green (BCG) and bromocresol purple (BCP) can suffer from aselectivity, but the impact of aselectivity on the accuracy of plasma albumin results of CKD-patients is still unknown. Therefore, we evaluated the performance of BCG-, BCP- and JCTLM-endorsed immunological methods in patients with various stages of CKD. METHODS: We evaluated the performance of commonly used albumin methods in patients with CKD stages G1 through G5, the latter divided in two groups based on whether they received hemodialysis treatment. In total, 163 patient plasma samples were measured at 14 laboratories, on six different BCG and BCP-platforms, and four different immunological platforms. The results were compared with an ERM-DA-470k-corrected nephelometric assay. The implications on outcome is evaluated by the proportion of patient results <38 g/L for the diagnosis of protein energy wasting. RESULTS: Albumin results determined with BCP- and immunological methods showed the best agreement with the target value (92.7 and 86.2 %, respectively vs. 66.7 % for BCG, namely due to overestimation). The relative agreement of each method with the target value was platform-dependent, with larger variability in agreement between platforms noted for BCG and immunological methods (3.2-4.6 and 2.6-5.3 %) as opposed to BCP (0.7-1.5 %). The stage of CKD had similar effects on the variability in agreement for the three method-groups (0.6-1.8 % vs. 0.7-1.5 % vs. 0.4-1.6 %). The differences between methods cause discrepancies in clinical decision-making, as structurally fewer patients were diagnosed with protein energy wasting upon using BCG-based albumin results. CONCLUSIONS: Our study shows that BCP is fit for the intended use to measure plasma albumin levels in CKD patients from all stages, including patients on hemodialysis. In contrast, most BCG-based platforms falsely overestimate the plasma albumin concentration.


Subject(s)
Bromcresol Green , Renal Insufficiency, Chronic , Humans , Serum Albumin/analysis , Bromcresol Purple , Renal Dialysis , Renal Insufficiency, Chronic/diagnosis
11.
Clin Chem Lab Med ; 61(4): 608-626, 2023 03 28.
Article in English | MEDLINE | ID: mdl-36716120

ABSTRACT

The EU In-Vitro Diagnostic Device Regulation (IVDR) aims for transparent risk-and purpose-based validation of diagnostic devices, traceability of results to uniquely identified devices, and post-market surveillance. The IVDR regulates design, manufacture and putting into use of devices, but not medical services using these devices. In the absence of suitable commercial devices, the laboratory can resort to laboratory-developed tests (LDT) for in-house use. Documentary obligations (IVDR Art 5.5), the performance and safety specifications of ANNEX I, and development and manufacture under an ISO 15189-equivalent quality system apply. LDTs serve specific clinical needs, often for low volume niche applications, or correspond to the translational phase of new tests and treatments, often extremely relevant for patient care. As some commercial tests may disappear with the IVDR roll-out, many will require urgent LDT replacement. The workload will also depend on which modifications to commercial tests turns them into an LDT, and on how national legislators and competent authorities (CA) will handle new competences and responsibilities. We discuss appropriate interpretation of ISO 15189 to cover IVDR requirements. Selected cases illustrate LDT implementation covering medical needs with commensurate management of risk emanating from intended use and/or design of devices. Unintended collateral damage of the IVDR comprises loss of non-profitable niche applications, increases of costs and wasted resources, and migration of innovative research to more cost-efficient environments. Taking into account local specifics, the legislative framework should reduce the burden on and associated opportunity costs for the health care system, by making diligent use of existing frameworks.


Subject(s)
Clinical Laboratory Services , Reagent Kits, Diagnostic , Humans , Reagent Kits, Diagnostic/standards , European Union , Clinical Laboratory Services/legislation & jurisprudence
12.
PLoS One ; 17(12): e0279321, 2022.
Article in English | MEDLINE | ID: mdl-36548281

ABSTRACT

BACKGROUND: Chronic kidney disease (CKD) is a rising public health problem that may progress to kidney failure, requiring kidney replacement therapy. It is also associated with an increased incidence of cardiovascular disease (CVD). Because of its asymptomatic nature, CKD is often detected in a late stage. Population screening for albuminuria could allow early detection of people with CKD who may benefit from preventive treatment. In case such screening is performed in a general practitioner (GP) setting, this will result in relatively high costs. Home-based screening might be an effective and cost-effective alternative. AIM: The THOMAS study (Towards HOMe-based Albuminuria Screening) is designed to prospectively investigate two methods for home-based population screening for increased albuminuria to detect yet undiagnosed CKD and risk factors for progression and CVD. METHODS: This investigator initiated, randomized population-based study will include 15.000 individuals aged 45-80 years, who will be randomly assigned to be invited for a home-based screening test for albuminuria with a more conventional urine collection device or an innovative smartphone application. If the test result is positive upon confirmation (i.e., elevated albuminuria), participants are invited to a central screening facility for an elaborate screening for CKD and CVD risk factors. Participants are referred to their GP for appropriate treatment, if abnormalities are found. Primary endpoints are the participation rate, yield, and cost-effectiveness of the home-based screening and elaborate screening. CONCLUSIONS: The THOMAS study will evaluate the effectiveness and cost-effectiveness of home-based albuminuria screening in the general population for the early detection of CKD and CVD risk factors. It will provide insight into the willingness to participate in population screening for CKD and into the compliance of the general population to a corresponding screening protocol and compliance to participate. Thus, it may help to develop an attractive novel screening strategy for the early detection of CKD. TRIAL REGISTRATION: ClinicalTrials.gov, registration number NCT04295889, registered 05 March 2020. https://www.google.com/search?client=firefox-b-d&q=NCT04295889.


Subject(s)
Cardiovascular Diseases , Renal Insufficiency, Chronic , Humans , Albuminuria/epidemiology , Feasibility Studies , Mass Screening/methods , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/epidemiology , Renal Insufficiency, Chronic/therapy , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/epidemiology , Randomized Controlled Trials as Topic
14.
PLoS One ; 17(5): e0268522, 2022.
Article in English | MEDLINE | ID: mdl-35588100

ABSTRACT

The aim of this study was to determine reference intervals in an outpatient population from Vall d'Hebron laboratory using an indirect approach previously described in a Dutch population (NUMBER project). We used anonymized test results from individuals visiting general practitioners and analysed during 2018. Analytical quality was assured by EQA performance, daily average monitoring and by assessing longitudinal accuracy between 2018 and 2020 (using trueness verifiers from Dutch EQA). Per test, outliers by biochemically related tests were excluded, data were transformed to a normal distribution (if necessary) and means and standard deviations were calculated, stratified by age and sex. In addition, the reference limit estimator method was also used to calculate reference intervals using the same dataset. Finally, for standardized tests reference intervals obtained were compared with the published NUMBER results. Reference intervals were calculated using data from 509,408 clinical requests. For biochemical tests following a normal distribution, similar reference intervals were found between Vall d'Hebron and the Dutch study. For creatinine and urea, reference intervals increased with age in both populations. The upper limits of Gamma-glutamyl transferase were markedly higher in the Dutch study compared to Vall d'Hebron results. Creatine kinase and uric acid reference intervals were higher in both populations compared to conventional reference intervals. Medical test results following a normal distribution showed comparable and consistent reference intervals between studies. Therefore a simple indirect method is a feasible and cost-efficient approach for calculating reference intervals. Yet, for generating standardized calculated reference intervals that are traceable to higher order materials and methods, efforts should also focus on test standardization and bias assessment using commutable trueness verifiers.


Subject(s)
Laboratories , Outpatients , Creatine Kinase , Creatinine , Humans , Reference Standards , Reference Values
15.
Clin Chem Lab Med ; 60(5): 681-688, 2022 04 26.
Article in English | MEDLINE | ID: mdl-35172415

ABSTRACT

Clinicians trust medical laboratories to provide reliable results on which they rely for clinical decisions. Laboratories fulfil their responsibility for accurate and consistent results by utilizing an arsenal of approaches, ranging from validation and verification experiments to daily quality control procedures. All these procedures verify, on different moments, that the results of a certain examination procedure have analytical performance characteristics (APC) that meet analytical performance specifications (APS) set for a particular intended use. The APC can in part be determined by estimating the measurement uncertainty component under conditions of within-laboratory precision (uRw), which comprises all components influencing the measurement uncertainty of random sources. To maintain the adequacy of their measurement procedures, laboratories need to distinguish aspects that are manageable vs. those that are not. One of the aspects that may influence uRw is the momentary significant bias caused by shifts in reagent and/or calibrator lots, which, when accepted or unnoticed, become a factor of the APC. In this paper, we postulate a model for allocating a part of allowable uRw to between-reagent lot variation, based on the need for long-term consistency of the measurement variability for that specific measurand. The allocation manages the ratio between short-term and long-term variation and indicates laboratories when to reject or correct certain variations due to reagent lots.


Subject(s)
Laboratories , Calibration , Humans , Indicators and Reagents , Quality Control , Uncertainty
16.
Clin Chem Lab Med ; 60(3): 361-369, 2022 02 23.
Article in English | MEDLINE | ID: mdl-35041777

ABSTRACT

OBJECTIVES: Medical laboratories may, at their own discretion, exceed but not undercut regulatory quality requirements. Available economic resources, however, may drive or hinder eagerness to exceed minimum requirements. Depending on the respective scopes of regulatory and economic framework conditions, differing levels of quality efforts to safeguard laboratory performance can be anticipated. However, this has not yet been investigated. METHODS: Immunohaematology external quality assessment (EQA) results collected by 26 EQA providers from their participant laboratories in 73 countries from 2004 to 2019 were evaluated. Error rates were aggregated in groups according to the respective national regulatory and economic framework conditions, to whether or not expert advice was provided in case of incorrect results, and the frequency of EQA samples. RESULTS: These representative data indicate no association between national regulatory (mandatory participation in EQA, monitoring of performance of individual laboratories by authorities, financial consequences of incorrect results) and economic (level of national income, share of national health expenditure) conditions to the quality performance of medical laboratories in immunohaematology. However, EQA providers' support for laboratories in the event of incorrect results appear to be associated with lower error rates, but a high EQA sample frequency with higher error rates. CONCLUSIONS: Further research into the impact of introducing or changing services of EQA providers is needed to confirm the results found in this first of its kind study.


Subject(s)
Hematology , Laboratories , Humans , Quality Assurance, Health Care
17.
Nephrol Dial Transplant ; 37(10): 1792-1799, 2022 09 22.
Article in English | MEDLINE | ID: mdl-33367921

ABSTRACT

Serum albumin is a widely used biomarker in clinical nephrology. Serum albumin cut-off values are used to define disease, to predict outcome and to guide patient care. The available commercial assays to measure serum albumin rely on different analytical principles, all with their own (analytical) specifications. This article provides an overview of the different clinical applications of serum albumin measurements in nephrology, the (dis)advantages of the available assays and the estimates of the effects of the measurement uncertainty between different assays in clinical decision making. This article concludes that harmonization of serum albumin assay results is needed.


Subject(s)
Nephrology , Clinical Decision-Making , Humans , Serum Albumin , Uncertainty
18.
Clin Chim Acta ; 522: 167-173, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34418364

ABSTRACT

The ISO 15189:2012 standard section 5.9.1 requires laboratories to review results before release, considering quality control, previous results, and clinical information, if any, and to issue documented procedures about it. While laboratory result reporting is generally regarded as part of the post-analytical phase, the result release process requires a general view of the total examination process. Reviewing test results may follow with troubleshooting and test repetition, including reanalyzing an individual sample or resampling. A systematic understanding of the result release may help laboratory professionals carry out appropriate test repetition and ensure the plausibility of laboratory results. In this paper, we addressed the crucial steps in the result release process, including evaluation of sample quality, critical result notification, result reporting, and recommendations for the management of the result release, considering quality control alerts, instrument flags, warning messages, and interference indexes. Error detection tools and plausibility checks mentioned in the present paper can support the daily practice of results release.


Subject(s)
Accreditation , Laboratories , Clinical Laboratory Techniques , Humans , Quality Control
20.
Clin Chem Lab Med ; 59(10): 1610-1622, 2021 09 27.
Article in English | MEDLINE | ID: mdl-34147043

ABSTRACT

Sepsis represents a global health priority because of its high mortality and morbidity. The key to improving prognosis remains an early diagnosis to initiate appropriate antibiotic treatment. Procalcitonin (PCT) is a recognized biomarker for the early indication of bacterial infections and a valuable tool to guide and individualize antibiotic treatment. To meet the increasing demand for PCT testing, numerous PCT immunoassays have been developed and commercialized, but results have been questioned. Many comparison studies have been carried out to evaluate analytical performance and comparability of results provided by the different commercially available immunoassays for PCT, but results are conflicting. External Quality Assessment Schemes (EQAS) for PCT constitute another way to evaluate results comparability. However, when making this comparison, it must be taken into account that the variety of EQA materials consist of different matrices, the commutability of which has not yet been investigated. The present study gathers results from all published comparison studies and results from 137 EQAS surveys to describe the current state-of-the-art harmonization of PCT results. Comparison studies globally highlight a significant variability of measurement results that nonetheless seem to have a moderate impact on medical decision-making. For their part, EQAS for PCT provides highly discrepant estimates of the interlaboratory CV. Due to differences in commutability of the EQA materials, the results from different peer groups could not be compared. To improve the informative value of the EQA data, the existing limitations such as non-harmonized conditions and suboptimal and/or unknown commutability of the EQA materials have to be overcome. The study highlights the need for commutable reference materials that could be used to properly evaluate result comparability and possibly standardize calibration, if necessary. Such an initiative would further improve the safe use of PCT in clinical routine.


Subject(s)
Procalcitonin , Sepsis , Calibration , Humans , Immunoassay , Quality Control , Sepsis/diagnosis