Results 1 - 20 de 95
Filter
2.
Polymers (Basel) ; 16(10)2024 May 11.
Article in English | MEDLINE | ID: mdl-38794563

ABSTRACT

In this study, electrospun scaffolds were fabricated using polycaprolactone (PCL) loaded with varying concentrations of ß-carotene (1.2%, 2.4%, and 3.6%) via the electrospinning technique. The electrospinning process involved the melting of PCL in acetic acid, followed by the incorporation of ß-carotene powder under constant stirring. Raman spectroscopy revealed a homogeneous distribution of ß-carotene within the PCL matrix. However, the ß-carotene appeared in particulate form, rather than being dissolved and blended with the PCL matrix, a result also confirmed by thermogravimetric analysis. Additionally, X-ray diffraction analysis indicated a decrease in crystallinity with increasing ß-carotene concentration. Mechanical testing of the scaffolds demonstrated an increase in ultimate strain, accompanied by a reduction in ultimate stress, indicating a potential plasticizing effect. Moreover, antimicrobial assays revealed a marginal antibacterial effect against Escherichia coli for scaffolds with higher ß-carotene concentrations. Conversely, preliminary biological assessment using KUSA-A1 mesenchymal cells indicated enhanced cellular proliferation in response to the scaffolds, suggesting the potential biocompatibility and cell-stimulating properties of ß-carotene-loaded PCL scaffolds. Overall, this study provides insights into the fabrication and characterization of electrospun PCL scaffolds containing ß-carotene, laying the groundwork for further exploration in tissue engineering and regenerative medicine applications.

3.
3D Print Med ; 10(1): 13, 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38639834

ABSTRACT

BACKGROUND: Bioresorbable patient-specific additive-manufactured bone grafts, meshes, and plates are emerging as a promising alternative that can overcome the challenges associated with conventional off-the-shelf implants. The fabrication of patient-specific implants (PSIs) directly at the point-of-care (POC), such as hospitals, clinics, and surgical centers, allows for more flexible, faster, and more efficient processes, reducing the need for outsourcing to external manufacturers. We want to emphasize the potential advantages of producing bioresorbable polymer implants for cranio-maxillofacial surgery at the POC by highlighting its surgical applications, benefits, and limitations. METHODS: This study describes the workflow of designing and fabricating degradable polymeric PSIs using three-dimensional (3D) printing technology. The cortical bone was segmented from the patient's computed tomography data using Materialise Mimics software, and the PSIs were designed created using Geomagic Freeform and nTopology software. The implants were finally printed via Arburg Plastic Freeforming (APF) of medical-grade poly (L-lactide-co-D, L-lactide) with 30% ß-tricalcium phosphate and evaluated for fit. RESULTS: 3D printed implants using APF technology showed surfaces with highly uniform and well-connected droplets with minimal gap formation between the printed paths. For the plates and meshes, a wall thickness down to 0.8 mm could be achieved. In this study, we successfully printed plates for osteosynthesis, implants for orbital floor fractures, meshes for alveolar bone regeneration, and bone scaffolds with interconnected channels. CONCLUSIONS: This study shows the feasibility of using 3D printing to create degradable polymeric PSIs seamlessly integrated into virtual surgical planning workflows. Implementing POC 3D printing of biodegradable PSI can potentially improve therapeutic outcomes, but regulatory compliance must be addressed.

4.
Heliyon ; 10(8): e29185, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38638944

ABSTRACT

Objective: Cleft lip and palate is the most common craniofacial birth anomaly and requires surgery in the first year of life. However, craniofacial surgery training opportunities are limited. The aim of this study was to present and evaluate an open-source cleft lip and palate hybrid (casting and three-dimensional (3D) printing) simulation model which can be replicated at low cost to facilitate the teaching and training of cleft surgery anatomy and techniques. Design: The soft tissue component of the cleft surgery training model was casted using a 3D printed 5-component mold and silicone. The bony structure was designed to simulate the facial anatomy and to hold the silicone soft tissue. Setting: Two groups, one group of trainees and one group of expert surgeons, at University Hospital Basel in Switzerland and Pontifical Catholic University of Chile in Santiago, Chile, tested the cleft lip and palate simulation model. Participants completed a Likert-based face and content validity questionnaire to assess the realism of the model and its usefulness in surgical training. Results: More than 70 % of the participants agreed that the model accurately simulated human tissues found in patients with unilateral cleft lip and palate. Over 60 % of the participants also agreed that the model realistically replicated surgical procedures. In addition, 80-90 % of the participants found the model to be a useful and appropriate tool for teaching the anatomy and surgical techniques involved in performing unilateral cleft lip and palate repair. Conclusion: This open-source protocol provides a cost-effective solution for surgeons to introduce the cleft morphology and surgical techniques to trainees on a regular basis. It addresses the current financial barrier that limits access to commercially available models during the early stages of surgeon training prior to specialization in the field.

5.
J Craniofac Surg ; 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38526121

ABSTRACT

Primary intraosseous meningioma (PIM) is a rare subtype of extradural meningiomas, with the indication for surgical resection in most cases. With an increasing demand for efficient workflows with optimal functional and cosmetical results, techniques for bone reconstruction after resection are developing rapidly. The authors present 2 cases with one-stage cranioplasty after resection of PIM, using 3D technology for preplanned patient-specific implants. In the first case, a premanufactured patient-specific PEEK implant was used for reconstruction; in the second case, a 3-dimensional (3D)-based premanufactured silicon mold was used to produce a customized PMMA implant intraoperatively. Both techniques enabled the surgeons to achieve optimal intraoperative fit of the implant after craniectomy, leading to satisfying functional and cosmetic results. The use of 3D technology, such as Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) for the production of patient-specific implants can optimize 1-stage cranioplasty after PIM resection.

6.
Dent Mater ; 40(4): 674-688, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38388252

ABSTRACT

OBJECTIVE: Polyetheretherketone (PEEK), a biomaterial with appropriate bone-like mechanical properties and excellent biocompatibility, is widely applied in cranio-maxillofacial and dental applications. However, the lack of antibacterial effect is an essential drawback of PEEK material and might lead to infection and osseointegration issues. This study aims to apply a natural antibacterial agent, totarol coating onto the 3D printed PEEK surface and find an optimized concentration with balanced cytocompatibility, osteogenesis, and antibacterial capability. METHODS: In this study, a natural antibacterial agent, totarol, was applied as a coating to fused filament fabrication (FFF) 3D printed PEEK surfaces at a series of increasing concentrations (1 mg/ml, 5 mg/ml, 10 mg/ml, 15 mg/ml, and 20 mg/ml). The samples were then evaluated for cytocompatibility with L929 fibroblast and SAOS-2 osteoblast using live/dead staining and CCK-8 assay. The antibacterial capability was assessed by crystal violet staining, live/dead staining, and scanning electron microscopy (SEM) utilizing the oral primary colonizer S. gordonii and isolates of mixed oral bacteria in a stirring system simulating the oral environment. The appropriate safe working concentration for totarol coating is selected based on the results of the cytocompatibility and antibacterial test. Subsequently, the influence on osteogenic differentiation was evaluated by alkaline phosphatase (ALP) and alizarin red staining (ARS) analysis of pre-osteoblasts. RESULTS: Our results showed that the optimal concentration of totarol solution for promising antibacterial coating was approximately 10 mg/ml. Such surfaces could play an excellent antibacterial role by inducing a contact-killing effect with an inhibitory effect against biofilm development without affecting the healing of soft and hard tissues around FFF 3D printed PEEK implants or abutments. SIGNIFICANCE: This study indicates that the totarol coated PEEK has an improved antibacterial effect with excellent biocompatibility providing great clinical potential as an orthopedic/dental implant/abutment material.


Subject(s)
Abietanes , Benzophenones , Dental Implants , Osteogenesis , Polymers , Polyethylene Glycols/pharmacology , Polyethylene Glycols/chemistry , Ketones/pharmacology , Ketones/chemistry , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Printing, Three-Dimensional , Surface Properties
8.
J Clin Med ; 13(4)2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38398354

ABSTRACT

Background: The operation planning and production of individualized implants with the help of AI-based software after orbital fractures have become increasingly important in recent years. This retrospective study aimed to investigate the healthy orbitae of 372 patients from CT images in the bone and soft tissue windows using the Disior™ Bonelogic™ CMF Orbital software. (version 2.1.28). Methods: We analyzed the variables orbital volume, length, and area as a function of age and gender and compared bone and soft tissue windows. Results: For all variables, the intraclass correlation showed excellent agreement between the bone and soft tissue windows (p < 0.001). All variables showed higher values when calculated based on bone fenestration with, on average, 1 mL more volume, 0.35 mm more length, and 0.71 cm2 more area (p < 0.001). Across all age groups, men displayed higher values than women with, on average, 8.1 mL larger volume, a 4.78 mm longer orbit, and an 8.5 cm2 larger orbital area (p < 0.001). There was also a non-significant trend in all variables and both sexes toward growth with increasing age. Conclusions: These results mean that, due to the symmetry of the orbits in both the bone and soft tissue windows, the healthy orbit can be mirrored for surgical planning in the event of a fracture.

9.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38310332

ABSTRACT

OBJECTIVES: The aortic root (AoR) rotation and its spatial morphology at the base of the heart were postulated but not described in every detail. AoR rotation modalities may play an important role in decision-making during AoR surgery and its outcome. The aim was to provide a detailed spatial anatomy of the AoR rotation and its relation to the vital surrounding structure. METHODS: The AoR rotation and its relation to the surrounding structure were assessed in 104 patients with tricuspid aortic valve. The interatrial septum was chosen as a reference to describe AoR rotation that marked the midline of the heart base as a landmark for the AoR rotation direction. Intermediate, clockwise and counterclockwise AoR rotations were defined based on the mentioned reference structures. RESULTS: The AoR rotation was successfully assessed in 104 patients undergoing ascending aorta and or AoR intervention by multidetector row computed tomography. AoR was positioned normally in 53.8% of cases (n = 56) and rotated counterclockwise in 5.8% (n = 6) and clockwise in 40.4% (n = 42) of cases. In clockwise AoR rotation, the right coronary sinus was positioned in proximity to the right atrium and of the tricuspid valve, whereas in a counterclockwise rotation, the noncoronary sinus was placed over the tricuspid valve just over the membranous septum. CONCLUSIONS: The AoR's rotation can be diagnosed using multidetector row computed tomography. Understanding the anatomy of the aortic valve related to rotational position helps guide surgical decision-making in performing AoR reconstruction.


Subject(s)
Aorta, Thoracic , Aorta , Humans , Aorta/surgery , Aortic Valve/surgery , Tricuspid Valve , Multidetector Computed Tomography
10.
J Craniofac Surg ; 35(1): 220-222, 2024.
Article in English | MEDLINE | ID: mdl-37603898

ABSTRACT

Orbital cavernous hemangiomas are the most common primary orbital tumors in adults, providing challenges for optimal surgical approach planning within an anatomically complex area with close proximity to vital neurovascular structures. The authors present an individualized lateral mini-orbitozygomatic approach for the resection of an orbital cavernous haemangioma based on a preoperative 3-dimensional-printed model. This individualized approach enabled the surgeons to achieve optimal exposure while maintaining safety during the resection of the lesion, but also to respect the patient's physiognomy and hairline. In addition, the model was used for patient informed consent, helping the patient understand the procedure. Although adding additional effort to preoperative planning, 3-dimensional model-based approaches can offer great benefits when it comes to customizing surgical approaches, especially for anatomically challenging resections.


Subject(s)
Hemangioma, Cavernous , Orbital Neoplasms , Adult , Humans , Orbital Neoplasms/diagnostic imaging , Orbital Neoplasms/surgery , Orbital Neoplasms/pathology , Hemangioma, Cavernous/diagnostic imaging , Hemangioma, Cavernous/surgery , Printing, Three-Dimensional
11.
Plast Reconstr Surg ; 153(2): 462-465, 2024 02 01.
Article in English | MEDLINE | ID: mdl-37184464

ABSTRACT

SUMMARY: Documenting complex three-dimensional (3D) cleft lip and palate malformation with plaster casts based on maxillary impressions is standard care. Presurgical orthopedic treatment also requires an impression. Digital impression-taking in patients with cleft lip and palate is feasible, but procurement costs hinder clinical implementation. Individualized impression trays allow for a precise impression, limiting airway risk. The authors present an open-source impression tray library with scalable impression trays not requiring 3D modeling knowledge. The cleft lip and palate impression tray library is accessible on Open Science Framework. Different shapes are available, and the tray size is selected based on the tuber distance. This allows 3D printing with biocompatible material at the point of care complying with local regulations. The open-source cleft tray library presented offers a hybrid solution for cleft centers, pending the implementation of digital impression.


Subject(s)
Cleft Lip , Cleft Palate , Humans , Cleft Lip/surgery , Cleft Palate/surgery , Workflow , Printing, Three-Dimensional , Dental Impression Technique
12.
J Hand Surg Eur Vol ; 49(3): 350-358, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37458129

ABSTRACT

We compared patient satisfaction and clinical effectiveness of 3D-printed splints made of photopolymer resin to conventional fibre glass casts in treating distal radial fractures. A total of 39 patients with minimally displaced distal radius fractures were included and randomized. Of them, 20 were immobilized in a fibre glass cast and 19 in a 3D-printed forearm splint. The 3D-printed splints were custom-designed based on forearm surface scanning with a handheld device and printed in-house using digital light processing printing technology. Patient satisfaction and clinical effectiveness were assessed with questionnaires 1 and 6 weeks after the initiation of immobilization. Fracture healing, pain, range of motion, grip strength and the DASH and PRWE scores were assessed up to 1-year follow-up. 3D-printed splints proved to be equally well tolerated by the patients and equally clinically effective as conventional fibre glass casts although there was a higher rate of minor complications. 3D-printed splints present a safe alternative, especially in young, active patients, for non-operative treatment of distal radial fractures.Level of evidence: I.


Subject(s)
Joint Diseases , Radius Fractures , Wrist Fractures , Humans , Radius Fractures/surgery , Splints , Casts, Surgical , Treatment Outcome , Printing, Three-Dimensional
13.
J Vasc Surg Cases Innov Tech ; 9(4): 101354, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38078283

ABSTRACT

An aorto-esophageal fistula (AEF) is a rare complication of aortic surgery but can cause potentially lethal upper gastrointestinal tract bleeding. A patient presented with an AEF secondary to emergency endovascular repair of a contained penetrating atherosclerotic ulcer rupture of the thoracic aorta and was successfully treated with endoscopic closure using fibrin glue. As endovascular repair becomes increasingly common, a greater incidence of AEFs should be anticipated and the treatment options better described.

15.
Oral Maxillofac Surg ; 2023 Jul 29.
Article in English | MEDLINE | ID: mdl-37516667

ABSTRACT

OBJECTIVES: This study aimed to compare the reconstruction with type 2.4 and three-dimensional (3D) grid plates relating the areas of weakness to anatomical regions of force incidence in atrophic mandibles with and without segmentation using finite element analysis (FEA). MATERIALS AND METHODS: Strength and force quality in the mandible were also determined. The atrophic mandible models with and without segmentation were divided into four groups, and the behavior of each plate was analyzed using finite element analysis. In the atrophic mandible without segmentation using the type 2.4 reconstruction plate, the highest stress concentration in the plate was observed in the posterior region of the mandibular body and in the grid type 3D reconstruction plate was observed in the mandibular angle. RESULTS: In the segmented atrophic mandible with the 2.4 reconstruction plate, higher stress concentration was observed in the mandibular segment defect. Analysis of the 3D grid-like reconstruction plate revealed that the geometry of the plate conferred greater stiffness to the assembly, as the most significant stress concentration was observed at the mandibular angle. CONCLUSION: The width of the plate design may influence the strength, not the thickness.

16.
J Mech Behav Biomed Mater ; 144: 105948, 2023 08.
Article in English | MEDLINE | ID: mdl-37348171

ABSTRACT

Only a few mandibular bone finite element (FE) models have been validated in literature, making it difficult to assess the credibility of the models. In a comparative study between FE models and biomechanical experiments using a synthetic polyamide 12 (PA12) mandible model, we investigate how material properties and boundary conditions affect the FE model's accuracy using the design of experiments approach. Multiple FE parameters, such as contact definitions and the materials' elastic and plastic deformation characteristics, were systematically analyzed for an intact mandibular model and transferred to the fracture fixation model. In a second step, the contact definitions for the titanium screw and implant (S-I), implant and PA12 mandible (I-M), and interfragmentary (IF) PA12 segments were optimized. Comparing simulated deformations (from 0 to -5 mm) and reaction forces (from 10 to 1'415 N) with experimental results showed a strong sensitivity to FE mechanical properties and contact definitions. The results suggest that using the bonded definition for the screw-implant contact of the fracture plate is ineffective. The contact friction parameter set with the highest agreement was identified: titanium screw and implant µ = 0.2, implant and PA12 mandible µ = 0.2, interfragmentary PA12 mandible µ = 0.1. The simulated reaction force (RMSE = 26.60 N) and surface displacement data (RMSE = 0.19 mm) of the FE analysis showed a strong agreement with the experimental biomechanical data. The results were generated through parameter optimization which means that our findings need to be validated in the event of a new dataset with deviating anatomy. Conclusively, the predictive capability of the FE model can be improved by FE model calibration through experimental testing. Validated preoperative quasi-static FE analysis could allow engineers and surgeons to accurately estimate how the implant's choice and placement suit the patient's biomechanical needs.


Subject(s)
Mandibular Fractures , Humans , Mandibular Fractures/surgery , Finite Element Analysis , Titanium , Fracture Fixation, Internal/methods , Biomechanical Phenomena , Mandible , Bone Plates , Stress, Mechanical
17.
J Clin Med ; 12(10)2023 May 12.
Article in English | MEDLINE | ID: mdl-37240532

ABSTRACT

This study aimed to perform a systematic review and meta-analysis to compare pre-shaped implants on a patient-specific 3D-printed (3DP) model to manual free-hand shaping (MFS) for orbital wall reconstruction. The PRISMA protocol was followed in this study, and the review was registered in the PROSPERO database (CRD42021261594). A search was conducted in MEDLINE (PubMed), Embase, Cochrane Library, Clinicaltrials.gov, Google Scholar, and the grey literature. Ten articles were included, and six outcomes were analyzed. In total, 281 patients were in the 3DP group and 283 were in the MFS group. The studies had an overall high risk of bias. 3DP models resulted in a better accuracy of fit, anatomical angle reproduction, and defect area coverage. The correction of orbital volume was also superior with statistical significance. There was a higher percentage of the correction of enophthalmos and diplopia in the 3DP group. Intraoperative bleeding and hospital stay were reduced in the 3DP group. The meta-analysis of operative time showed a reduction in the average operative time by 23.58 min (95% CI: -43.98 to -3.19), which was statistically significant (t(6) = -2.8299, p = 0.0300). The 3DP models appear advantageous for an accurate orbital wall reconstruction, with fewer complications than those for conventional free-hand-shaped implants.

18.
Bioengineering (Basel) ; 10(5)2023 May 17.
Article in English | MEDLINE | ID: mdl-37237673

ABSTRACT

Medical image segmentation, whether semi-automatically or manually, is labor-intensive, subjective, and needs specialized personnel. The fully automated segmentation process recently gained importance due to its better design and understanding of CNNs. Considering this, we decided to develop our in-house segmentation software and compare it to the systems of established companies, an inexperienced user, and an expert as ground truth. The companies included in the study have a cloud-based option that performs accurately in clinical routine (dice similarity coefficient of 0.912 to 0.949) with an average segmentation time ranging from 3'54″ to 85'54″. Our in-house model achieved an accuracy of 94.24% compared to the best-performing software and had the shortest mean segmentation time of 2'03″. During the study, developing in-house segmentation software gave us a glimpse into the strenuous work that companies face when offering clinically relevant solutions. All the problems encountered were discussed with the companies and solved, so both parties benefited from this experience. In doing so, we demonstrated that fully automated segmentation needs further research and collaboration between academics and the private sector to achieve full acceptance in clinical routines.

19.
J Clin Med ; 12(8)2023 Apr 19.
Article in English | MEDLINE | ID: mdl-37109288

ABSTRACT

This study aimed to evaluate the availability and use of dental and maxillofacial emergency algorithms in Swiss hospitals. A survey was performed among physicians at Swiss emergency departments (ED) and participants of the "36th Annual Meeting of the Society for Oral and Cranio-Maxillofacial Surgery". Eighty-nine EDs in Switzerland were questioned about the availability and use of electronic algorithms in their hospitals. Eighty-one (91%) participated in the study. In 75 (93%) of the EDs, electronic algorithms are used, mainly "medStandards". Six have no available algorithms. Fifty-two (64%) use algorithms daily. Eight (10%) Swiss EDs have maxillofacial and dental algorithms, and 73 (90%) have no access to or do not know about them. For dental algorithms, 28 (38%) of the respondents would like to have access, and 16 (22%) do not desire access. For maxillofacial algorithms, 23 (32%) want to have access and 21 (29%) do not want it. Most (74%) of the participating maxillofacial surgeons did not know about the existence of ED algorithms regarding their specialty. Our study shows that the existence of specific algorithms is often not known. Furthermore, there is a demand for dental and maxillofacial algorithms in Swiss EDs.

20.
J Clin Med ; 12(7)2023 Mar 25.
Article in English | MEDLINE | ID: mdl-37048579

ABSTRACT

Polyetheretherketone (PEEK) has become the biomaterial of choice for repairing craniofacial defects over time. Prospects for the point-of-care (POC) fabrication of PEEK customized implants have surfaced thanks to the developments in three-dimensional (3D) printing systems. Consequently, it has become essential to investigate the characteristics of these in-house fabricated implants so that they meet the necessary standards and eventually provide the intended clinical benefits. This study aimed to investigate the effects of the steam sterilization method on the dimensional accuracy of POC 3D-printed PEEK customized cranial implants. The objective was to assess the influence of standard sterilization procedures on material extrusion-based 3D-printed PEEK customized implants with non-destructive material testing. Fifteen PEEK customized cranial implants were fabricated using an in-house material extrusion-based 3D printer. After fabrication, the cranial implants were digitalized with a professional-grade optical scanner before and after sterilization. The dimensional changes for the 3D-printed PEEK cranial implants were analyzed using medically certified 3D image-based engineering software. The material extrusion 3D-printed PEEK customized cranial implants displayed no statistically significant dimensional difference with steam sterilization (p > 0.05). Evaluation of the cranial implants' accuracy revealed that the dimensions were within the clinically acceptable accuracy level with deviations under 1.00 mm. Steam sterilization does not significantly alter the dimensional accuracy of the in-house 3D-printed PEEK customized cranial implants.