1.
Article in English | MEDLINE | ID: mdl-38604832

ABSTRACT

BACKGROUND: The impact of new-onset left bundle branch block (N-LBBB) developing after Transcatheter Aortic Valve Replacement (TAVR) on cardiac function and mechanical dyssynchrony is not well defined. METHODS: We retrospectively screened all patients who underwent TAVR in our centre between Oct 2018 and Sept 2021 (n = 409). We identified 38 patients with N-LBBB post-operatively (of which 28 were persistent and 10 were transient), and 17 patients with chronic pre-existent LBBB (C-LBBB). We excluded patients requiring pacing post TAVR. For all groups, we retrospectively analysed stored echocardiograms at 3 time points: before TAVR (T0), early after TAVR (T1, 1.2 ± 1.1 days), and late follow-up (T2, 1.5 ± 0.8 years), comparing LV mass and volumes, indices of LV function (LV ejection fraction, LVEF; global longitudinal strain, GLS), and mechanical dyssynchrony indices (systolic stretch index, severity of septal flash). RESULTS: At baseline (T0), C-LBBB had worse cardiac function, and larger LV volumes and LV mass, compared with patients with N-LBBB. At T1, N-LBBB resulted in mild dyssynchrony and decreased LVEF and GLS. Dyssynchrony progressed at T2 in persistent N-LBBB but not C-LBBB. In both groups however, LVEF remained stable at T2, although individual response was variable. Patients with better LVEF at baseline demonstrated a higher proportion of developing LBBB-induced LV dysfunction at T2. Lack of improvement of LVEF immediately after TAVR predicted deteriorating LVEF at T2. In transient LBBB, cardiac function and most dyssynchrony indices returned to baseline. CONCLUSIONS: N-LBBB after TAVR results in an immediate reduction of cardiac function, in spite of only mild dyssynchrony. When LBBB persists, patients with better cardiac function before TAVR are more likely to have LBBB-induced LV dysfunction after TAVR.

2.
Article in English | MEDLINE | ID: mdl-37427306

ABSTRACT

Background: Hypersensitivity reactions (HSRs) to components of cardiac implantable electronic devices (CIEDs) are rare but difficult to differentiate from device infection. Data on best management strategies of HSRs to CIEDs are lacking. The aims of this systematic review are to summarise the available literature on the aetiology, diagnosis and management of HSR in CIED patients and to provide guidance on best management strategies for these patients. Methods and results: A systematic search for publications on HSR to CIED in PubMed from January 1970 to November 2022 was conducted, resulting in 43 publications reporting on 57 individual cases. The quality of data was low. The mean age was 57 ± 21 years, and 48% of patients were women. The mean time from implant to diagnosis was 29 ± 59 months. Multiple allergens were identified in 11 patients (19%). In 14 cases (25%) no allergen was identified. Blood tests were mostly normal (55%), but eosinophilia (23%), raised inflammatory markers (18%) and raised immunoglobulin E (5%) were also encountered. Symptoms included local reactions, systemic reactions or both in 77%, 21% and 7% of patients, respectively. Explantation of CIED and reimplantation of another CIED coated with a non-allergenic material was usually successful. Use of topical or systemic steroids was associated with high failure rates. Conclusion: Based on the limited data available, the treatment of choice for HSRs to CIEDs is full CIED removal, reassessment of CIED indication and reimplantation of devices coated in non-allergenic materials. Steroids (topical/systemic) have limited efficiency and should not be used. There is an urgent need for further research in this field.

3.
J Electrocardiol ; 68: 150-152, 2021.
Article in English | MEDLINE | ID: mdl-34455113

ABSTRACT

We present an artefactual ECG created by a digital ECG-recording machine, caused by deletion of the first 80 ms of the QRS complex immediately following the pacing spike in a patient with complete atrio-ventricular block, biventricular pacing and chronic atrial fibrillation. The artefact was mistaken for inferior ST elevation myocardial infarction and the patient underwent unnecessary urgent coronary angiogram. We are not aware of this particular artefact pattern being previously reported in the literature.


Subject(s)
Atrial Fibrillation , Cardiac Resynchronization Therapy , ST Elevation Myocardial Infarction , Atrial Fibrillation/diagnosis , Electrocardiography , Heart Ventricles , Humans , ST Elevation Myocardial Infarction/diagnosis
4.
J Electrocardiol ; 65: 146-150, 2021.
Article in English | MEDLINE | ID: mdl-33621799

ABSTRACT

We present a complex ECG displaying a combination of atrial tachycardia with Mobitz type I AV block, and right bundle branch block (RBBB) alternans (RBBB alternating with normal QRS conduction) during Wenckebach cycle. A detailed explanation regarding the mechanism of this complex arrhythmia is provided, and the mechanism of bundle branch alternans is reviewed. A unique feature of our case is the added complexity given by the presence of atrial tachycardia and AV Wenckebach, which departs from the previous description of bundle branch alternans during 1:1 AV conduction.


Subject(s)
Atrioventricular Block , Electrocardiography , Bundle-Branch Block/diagnosis , Heart Conduction System , Humans , Tachycardia
6.
J Electrocardiol ; 57: 77-80, 2019.
Article in English | MEDLINE | ID: mdl-31518910

ABSTRACT

We report a case of ST segment elevation and PR depression in inferolateral leads in a patient with small bowel occlusion and gastric distension that disappeared immediately after gastric evacuation. Contrary to prior reports, we believe that these ECG changes do not represent an intrinsic cardiac electrical abnormality, but are likely artefactual. We hypothesise that the accumulated air between the heart, lower limbs and left precordial electrodes result in a significant departure from the simplified assumptions of standard 12 lead ECG analysis (that the electrical activity of the heart can be described by an electrical dipole at a fixed location in an electrical homogeneous sphere) in such a way that the ECG filtering process will not compensate for this bias and will artificially create the ECG pattern described in this report.


Subject(s)
Myocardial Infarction , ST Elevation Myocardial Infarction , Arrhythmias, Cardiac , Electrocardiography , Electrodes , Humans
8.
J Cardiol Cases ; 14(1): 29-31, 2016 Jul.
Article in English | MEDLINE | ID: mdl-30546655

ABSTRACT

Techniques to overcome challenging venous anatomy have become an increasingly important part of modern day cardiac device implantation. Complete superior vena cava (SVC) obstruction, however, is a rare and serious clinical entity, and consequently there is limited clinical experience in addressing this pathology in the context of transvenous pacemaker implantation. We present the case of a 48-year-old renal transplant patient with sick sinus syndrome and recurrent syncope, who had an upper SVC occlusion and a failed epicardial pacing system. The SVC was re-canalized and stented using techniques derived from chronic total occlusion coronary angioplasty, thus allowing successful implantation of a transvenous pacemaker lead. This case highlights the increased risk of developing central venous occlusion that exists in renal dialysis patients, and demonstrates the benefits of utilizing transferable interventional coronary and radiology techniques to overcome this pathology and facilitate pacemaker implantation. .

10.
Open Heart ; 2(1): e000224, 2015.
Article in English | MEDLINE | ID: mdl-26019880

ABSTRACT

BACKGROUND: The application of a clinical magnet over an implantable cardioverter defibrillator (ICD) can be used to suspend tachycardia therapies in patients receiving recurrent or inappropriate shocks. In our institution, they have been routinely issued to patients undergoing ICD implantation during the past 5 years. The purpose of this survey was to investigate how well information concerning their use had been retained, and in what circumstances the magnets had been used. METHODS: We sent a questionnaire to 476 patients, and received a response from 343 (72%). Data was collated using 'Microsoft Excel', cross-referenced against our own pacing database, and analysed using basic statistical methods. RESULTS: 256 (74.6%) patients recalled being issued with a magnet. 48% of these were still in possession of their written information leaflet at the time of survey; 62% felt that they were able to remember when and how to use the magnet-with patients who had received written instructions and verbal reinforcement demonstrating the best recall. 8% of patients had used their magnets and the most common reason for use was multiple or inappropriate shocks. In addition, almost half of the patients who had suffered inappropriate shocks had been able to successfully use their magnets. No cases of harm related to magnet use were identified. CONCLUSIONS: The results of our survey suggest that routinely issuing clinical magnets to ICD patients is a safe and effective practice, and a small but significant number of patients were able to utilise their magnets in clinically important situations.

11.
Future Cardiol ; 11(3): 293-5, 2015 May.
Article in English | MEDLINE | ID: mdl-26021635

ABSTRACT

We present the case of a 28-year-old female with Emery-Dreifuss muscular dystrophy and breast hypoplasia, who underwent implantation of a subpectoral defibrillator and bilateral breast augmentation during a single elective procedure at our institution.


Subject(s)
Breast Diseases/surgery , Defibrillators, Implantable , Mastectomy, Segmental/methods , Muscular Dystrophy, Emery-Dreifuss/complications , Tachycardia, Ventricular/therapy , Adult , Breast Diseases/complications , Death, Sudden, Cardiac/prevention & control , Electrocardiography, Ambulatory , Female , Humans , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/physiopathology
12.
J Am Soc Echocardiogr ; 23(4): 423-31, 431.e1-6, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20202789

ABSTRACT

BACKGROUND: Myocardial acceleration during isovolumic contraction (IVA) has been validated as a relatively load-insensitive noninvasive index of contractility. Its feasibility, reproducibility, and variation between segments have not been studied in detail, and thus its utility in clinical practice has not been established. METHODS: We analyzed myocardial velocity loops (median frame rate 182 s(-1)) from 20 young volunteers (10 men, aged 25.7 +/- 2.9 years), 20 patients with type 2 diabetes (14 men, aged 64.1 +/- 8.5 years), and 20 patients with heart failure (17 men, aged 64.6 +/- 7.7 years). Long-axis IVA was measured in all walls at the annulus and in basal and mid-ventricular segments. Intraobserver reproducibility for 1 observer in all subjects and interobserver reproducibility among 3 observers in 10 subjects from each group were assessed. RESULTS: In control subjects, subjects with diabetes, and subjects with heart failure, the feasibility of measuring IVA was 97%, 89%, and 82%, respectively; intraobserver reproducibility was 12%, 18%, and 30%, respectively (pooled coefficients of variation); and mean interobserver reproducibility was 23%, 21%, and 28%, respectively. IVA was lower in the mid-ventricular segments by 24% to 43% compared with the annulus, and IVA was higher in the right than the left ventricle (P < .001). IVA of the medial mitral annulus discriminated those with heart failure from those with diabetes and controls, and had acceptable intraobserver reproducibility across groups (mean coefficient of variation 13%). CONCLUSION: IVA may be used as a research tool if it is measured at the medial mitral annulus, but its clinical applicability is hampered by low reproducibility, especially in patients with impaired left ventricular function in whom it would otherwise be most useful.


Subject(s)
Myocardial Contraction/physiology , Ventricular Function/physiology , Adult , Aged , Diabetes Mellitus, Type 2/physiopathology , Heart Failure/physiopathology , Humans , Male , Middle Aged , Observer Variation , Reproducibility of Results
13.
Eur J Echocardiogr ; 10(8): iii15-21, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19889654

ABSTRACT

Dilated cardiomyopathy (DCM) is a common and malignant condition, which carries a poor long-term prognosis. Underlying disease aetiologies are varied, and often carry specific implications for treatment and prognosis. The role of echocardiography is essential in not only establishing the diagnosis, but also in defining the aetiology, and understanding the pathophysiology. This article therefore explores the pivotal role of echocardiography in the evaluation and management of patients with DCM.


Subject(s)
Cardiomyopathy, Dilated/diagnostic imaging , Cardiomyopathy, Dilated/therapy , Echocardiography/methods , Cardiomyopathy, Dilated/etiology , Cardiomyopathy, Dilated/physiopathology , Diagnosis, Differential , Humans , Prognosis
14.
Eur J Heart Fail ; 11(8): 779-88, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19549647

ABSTRACT

AIMS: Dyssynchrony assessment in cardiac resynchronization therapy (CRT) is controversial, and there are no standard protocols for optimizing treatment. We studied the feasibility and reproducibility of several echocardiographic measures to optimize CRT pacemaker settings. We also assessed the utility of 'stroke distance' [left ventricular outflow tract velocity-time integral (LVOT VTI)] in performing this function. METHODS AND RESULTS: Thirty patients underwent the following functional assessments; 6 min walk test distance, peak VO(2) consumption on cardiopulmonary exercise testing (VO(2) peak), quality-of-life scoring, and echocardiography; before and at 3 and 6 months after implantation of the CRT device. At 3 months, patients received LVOT VTI-guided optimization of interventricular (VV) and atrioventricular (AV) delays. The feasibility and reproducibility of each optimization measurement was statistically analysed, and the functional benefits of optimization examined. Left ventricular outflow tract VTI, interventricular mechanical delay (IVMD), and tissue Doppler lateral-septal delay showed good feasibility (>90%), whereas LVOT VTI, IVMD, and the 12-segment tissue Doppler dyssynchrony index showed good reproducibility (coefficient of variation <20%). The most feasible and reproducible measure was LVOT VTI. Our optimization protocol necessitated alteration of AV and/or VV delays in 60% of patients at 3 months and was associated with a 50% improvement in functional responder status between 3 and 6 months. CONCLUSION: Left ventricular outflow tract VTI provides us with a single, direct measure of global LV function which is robust, and easily applicable in routine clinical practice, and which is effective at improving response to CRT.


Subject(s)
Cardiac Pacing, Artificial/methods , Heart Failure/therapy , Oxygen Consumption , Stroke Volume , Ultrasonography, Doppler , Analysis of Variance , Cardiac Output , Exercise Test , Feasibility Studies , Female , Health Status Indicators , Humans , Male , Middle Aged , Myocardial Ischemia/diagnostic imaging , Myocardial Ischemia/therapy , Prospective Studies , Quality of Life , Reproducibility of Results , Statistics as Topic , Surveys and Questionnaires
15.
Adv Exp Med Biol ; 645: 21-5, 2009.
Article in English | MEDLINE | ID: mdl-19227445

ABSTRACT

This study uses an organ chamber bioactivity assay to characterise the direct effect of sodium nitrite upon rabbit blood vessels (aorta (Ao), inferior vena cava (IVC) and pulmonary artery (PA)) in a haemoglobin independent/variable oxygen environment. In 95% oxygen constriction to 8g (Ao), 6g (PA) and 4g (IVC) was achieved using 1 microM phenylephrine. The same constriction in 1% oxygen required 3 microM. During 95% oxygen constriction was consistent and sustained for all vessels. However under 1% oxygen PA was quick to constrict but rapidly gave up this tension whereas Ao was slower to constrict but exhibited a more sustained response. Relaxation of each vessel was assessed post constriction using 10 microM sodium nitrite. Results were expressed as a percentage loss in tension compared to the maximum achieved and corrected by controls which received no nitrite. At 95% oxygen PA relaxed greater than Ao (10.04% +/- 2.28% vs. 5.25% +/- 1.51%). IVC response was varied (2.26% +/- 9.43%). At 1% oxygen all vessels relaxed more. However the pattern was reversed with both IVC (14.20% +/- 3.63%) and PA (16.55% +/- 0.93%) relaxing less than Ao (42.20% +/- 5.21%). These results suggest that relatively low concentrations of sodium nitrite can vasodilate blood vessels. This effect is independent of haemoglobin and tissue specific.


Subject(s)
Blood Vessels/drug effects , Blood Vessels/metabolism , Hypoxia/metabolism , Nitrites/pharmacology , Oxygen/metabolism , Animals , Male , Rabbits