Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
J Magn Reson Imaging ; 49(3): 744-751, 2019 03.
Article in English | MEDLINE | ID: mdl-30211442

ABSTRACT

BACKGROUND: Safe and accurate imaging of the peripheral arterial system is important for diagnosis and treatment planning of patients with peripheral artery disease (PAD). PURPOSE: To evaluate image quality and diagnostic performance of unenhanced magnetic resonance angiography (MRA) based on velocity-selective (VS) magnetization preparation (termed VS-MRA). STUDY TYPE: Prospective. POPULATION: Thirty-one symptomatic PAD patients underwent VS-MRA. Twenty-four of them underwent clinical digital subtraction angiography (DSA) examination, 18.8 ± 5.2 days after the MR scans. FIELD STRENGTH/SEQUENCE: 1.5T MRI that included VS-MRA (homemade research sequence) and phase-contrast flow imaging (clinical sequence). ASSESSMENT: Image quality (0: nondiagnostic, 3: excellent) and stenosis severity (0: normal, 3: occlusion) of VS-MRA images were assessed independently by three reviewers. Arterial signal-to-noise-ratio (SNR) and artery-to-muscle contrast-to-noise ratio (CNR) were calculated. STATISTICAL TESTS: The sensitivity and specificity of VS-MRA were calculated for the detection of significant stenosis (>50%) with DSA as the reference standard. Interobserver agreement among the three reviewers was evaluated by using Cohen κ-statistics. RESULTS: The image quality score of VS-MRA was 2.7 ± 0.5 for Reader 1, 2.8 ± 0.5 for Reader 2, and 2.8 ± 0.4 for Reader 3; SNR and CNR were 37.8 ± 12.5 and 30.5 ± 11.8, respectively. Segment-based analysis revealed that VS-MRA had sensitivities of 85.3%, 74.5%, and 78.4%, respectively, for the three reviewers, and specificities of 93.5%, 96.8%, and 95.2%. The interobserver agreement for the stenosis grading was good, as demonstrated by Cohen κ values of 0.76 (Reader 1 vs. Reader 2), 0.82 (Reader 1 vs. Reader 3), and 0.79 (Reader 2 vs. Reader 3). DATA CONCLUSION: Unenhanced VS-MRA allows clear depiction of the peripheral arteries and accurate stenosis grading, as evidenced by high image quality scores and strong agreement with DSA. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:744-751.


Subject(s)
Angiography, Digital Subtraction , Image Processing, Computer-Assisted/methods , Magnetic Resonance Angiography , Peripheral Arterial Disease/diagnostic imaging , Aged , Contrast Media/chemistry , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity
2.
Am J Cardiol ; 122(10): 1712-1717, 2018 11 15.
Article in English | MEDLINE | ID: mdl-30266255

ABSTRACT

Atrioventricular conduction disturbances requiring implantation of permanent pacemaker (PPM) are a common complication following transcatheter aortic valve implantation (TAVI). Previous registry data are conflicting but suggestive of an increased risk in heart failure admissions in the post-TAVI PPM cohort. Given the expanding use of TAVI, the present study evaluates the effects of chronic right ventricular pacing (RV pacing) in post-TAVI patients. This is a single-center study of 672 patients who underwent TAVI from 2011 to 2017 of which 146 underwent PPM. Follow-up 1-year post-TAVI outcome data were available for 55 patients and were analyzed retrospectively. Patients who underwent PPM were more likely to have heart failure admissions (17.1% vs 10.1%; hazard ratio [HR] 1.70; 95% confidence interval [CI] 1.10 to 2.64; p 0.019) and a trend toward increased mortality (21.9% vs 15.4%; HR 1.42; 95% CI 0.99 to 2.05; p 0.062). At 1-year follow-up, 30 of 55 (54.5%) patients demonstrated >40% RV pacing. Compared with patients who had <40% RV pacing, those with >40% RV pacing were more likely to have heart failure admissions (8% vs 40%; HR 5.0; 95% CI 1.23 to 20.27; p 0.007) and demonstrated a trend toward increased mortality (12% vs 33.3%; HR 2.78; 95% CI 0.86 to 9.00; p 0.064). This is suggestive that the post-TAVI PPM cohort is particularly sensitive to chronic RV pacing.


Subject(s)
Aortic Valve Stenosis/surgery , Arrhythmias, Cardiac/therapy , Heart Ventricles/physiopathology , Pacemaker, Artificial , Postoperative Complications/therapy , Transcatheter Aortic Valve Replacement/adverse effects , Ventricular Function, Right/physiology , Adult , Aged , Aged, 80 and over , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/etiology , Cause of Death/trends , Electrocardiography , Female , Follow-Up Studies , Humans , Incidence , Male , Middle Aged , Ohio/epidemiology , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Prognosis , Registries , Retrospective Studies , Risk Factors , Survival Rate/trends
SELECTION OF CITATIONS
SEARCH DETAIL