Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 38
Filter
Add more filters










Publication year range
1.
J Opt Soc Am A Opt Image Sci Vis ; 40(6): 1249-1259, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37706779

ABSTRACT

A new method is developed for 3D reconstruction of multimaterial objects using propagation-based x-ray phase-contrast tomography (PB-CT) with phase retrieval via contrast-transfer-function (CTF) formalism. The approach differs from conventional PB-CT algorithms, which apply phase retrieval to individual 2D projections. Instead, this method involves performing phase retrieval to the CT-reconstructed volume in 3D. The CTF formalism is further extended to the cases of partially coherent illumination and strongly absorbing samples. Simulated results demonstrate that the proposed post-reconstruction CTF method provides fast and stable phase retrieval, producing results equivalent to conventional pre-reconstruction 2D CTF phase retrieval. Moreover, it is shown that application can be highly localized to isolated objects of interest, without a significant loss of quality, thus leading to increased computational efficiency. Combined with the extended validity of the CTF to greater propagation distances, this method provides additional advantages over approaches based on the transport-of-intensity equation.

2.
J Med Imaging (Bellingham) ; 8(5): 052108, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34268442

ABSTRACT

Purpose: Breast cancer is the most common cancer in women in developing and developed countries and is responsible for 15% of women's cancer deaths worldwide. Conventional absorption-based breast imaging techniques lack sufficient contrast for comprehensive diagnosis. Propagation-based phase-contrast computed tomography (PB-CT) is a developing technique that exploits a more contrast-sensitive property of x-rays: x-ray refraction. X-ray absorption, refraction, and contrast-to-noise in the corresponding images depend on the x-ray energy used, for the same/fixed radiation dose. The aim of this paper is to explore the relationship between x-ray energy and radiological image quality in PB-CT imaging. Approach: Thirty-nine mastectomy samples were scanned at the imaging and medical beamline at the Australian Synchrotron. Samples were scanned at various x-ray energies of 26, 28, 30, 32, 34, and 60 keV using a Hamamatsu Flat Panel detector at the same object-to-detector distance of 6 m and mean glandular dose of 4 mGy. A total of 132 image sets were produced for analysis. Seven observers rated PB-CT images against absorption-based CT (AB-CT) images of the same samples on a five-point scale. A visual grading characteristics (VGC) study was used to determine the difference in image quality. Results: PB-CT images produced at 28, 30, 32, and 34 keV x-ray energies demonstrated statistically significant higher image quality than reference AB-CT images. The optimum x-ray energy, 30 keV, displayed the largest area under the curve ( AUC VGC ) of 0.754 ( p = 0.009 ). This was followed by 32 keV ( AUC VGC = 0.731 , p ≤ 0.001 ), 34 keV ( AUC VGC = 0.723 , p ≤ 0.001 ), and 28 keV ( AUC VGC = 0.654 , p = 0.015 ). Conclusions: An optimum energy range (around 30 keV) in the PB-CT technique allows for higher image quality at a dose comparable to conventional mammographic techniques. This results in improved radiological image quality compared with conventional techniques, which may ultimately lead to higher diagnostic efficacy and a reduction in breast cancer mortalities.

4.
Acad Radiol ; 28(1): e20-e26, 2021 01.
Article in English | MEDLINE | ID: mdl-32035759

ABSTRACT

RATIONALE AND OBJECTIVES: Propagation-based phase-contrast CT (PB-CT) is an advanced X-ray imaging technology that exploits both refraction and absorption of the transmitted X-ray beam. This study was aimed at optimizing the experimental conditions of PB-CT for breast cancer imaging and examined its performance relative to conventional absorption-based CT (AB-CT) in terms of image quality and radiation dose. MATERIALS AND METHODS: Surgically excised breast mastectomy specimens (n = 12) were scanned using both PB-CT and AB-CT techniques under varying imaging conditions. To evaluate the radiological image quality, visual grading characteristics (VGC) analysis was used in which 11 breast specialist radiologists compared the overall image quality of PB-CT images with respect to the corresponding AB-CT images. The area under the VGC curve was calculated to measure the differences between PB-CT and AB-CT images. RESULTS: The highest radiological quality was obtained for PB-CT images using a 32 keV energy X-ray beam and by applying the Homogeneous Transport of Intensity Equation phase retrieval with the value of its parameter γ set to one-half of the theoretically optimal value for the given materials. Using these optimized conditions, the image quality of PB-CT images obtained at 4 mGy and 2 mGy mean glandular dose was significantly higher than AB-CT images at 4 mGy (AUCVGC = 0.901, p = 0.001 and AUCVGC = 0.819, p = 0.011, respectively). CONCLUSION: PB-CT achieves a higher radiological image quality compared to AB-CT even at a considerably lower mean glandular dose. Successful translation of the PB-CT technique for breast cancer imaging can potentially result in improved breast cancer diagnosis.


Subject(s)
Breast Neoplasms , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Humans , Mastectomy , Radiation Dosage , Tomography, X-Ray Computed
5.
J Synchrotron Radiat ; 26(Pt 3): 825-838, 2019 May 01.
Article in English | MEDLINE | ID: mdl-31074448

ABSTRACT

The following article describes a method for 3D reconstruction of multi-material objects based on propagation-based X-ray phase-contrast tomography (PB-CT) with phase retrieval using the homogeneous form of the transport of intensity equation (TIE-Hom). Unlike conventional PB-CT algorithms that perform phase retrieval of individual projections, the described post-reconstruction phase-retrieval method is applied in 3D to a localized region of the CT-reconstructed volume. This work demonstrates, via numerical simulations, the accuracy and noise characteristics of the method under a variety of experimental conditions, comparing it with both conventional absorption tomography and 2D TIE-Hom phase retrieval applied to projection images. The results indicate that the 3D post-reconstruction method generally achieves a modest improvement in noise suppression over existing PB-CT methods. It is also shown that potentially large computational gains over projection-based phase retrieval for multi-material samples are possible. In particular, constraining phase retrieval to a localized 3D region of interest reduces the overall computational cost and eliminates the need for multiple CT reconstructions and global 2D phase retrieval operations for each material within the sample.

6.
Curr Protoc Chem Biol ; 11(1): e61, 2019 03.
Article in English | MEDLINE | ID: mdl-30645048

ABSTRACT

For over 20 years, native chemical ligation (NCL) has played a pivotal role in enabling total synthesis and semisynthesis of increasingly complex peptide and protein targets. Classical NCL proceeds by chemoselective reaction of two unprotected polypeptide chains in near-neutral-pH, aqueous solution and is made possible by the presence of a thioester moiety on the C-terminus of the N-terminal peptide fragment and a natural cysteine residue on the N-terminus of the C-terminal peptide fragment. The reaction yields an amide bond adjacent to cysteine at the ligation site, furnishing a native protein backbone in a traceless manner. This unit highlights a number of recent and powerful advances in the methodology and outlines their particular uses, facilitating application in the synthesis of challenging protein targets. © 2019 by John Wiley & Sons, Inc.


Subject(s)
Peptides/chemistry , Peptides/chemical synthesis , Proteins/chemistry , Proteins/chemical synthesis , Hydrogen-Ion Concentration , Solutions
7.
Acad Radiol ; 26(6): e79-e89, 2019 06.
Article in English | MEDLINE | ID: mdl-30149975

ABSTRACT

RATIONALE AND OBJECTIVES: This study employs clinical/radiological evaluation in establishing the optimum imaging conditions for breast cancer imaging using the X-ray propagation-based phase-contrast tomography. MATERIALS AND METHODS: Two series of experiments were conducted and in total 161 synchrotron-based computed tomography (CT) reconstructions of one breast mastectomy specimen were produced at different imaging conditions. Imaging factors include sample-to-detector distance, X-ray energy, CT reconstruction method, phase retrieval algorithm applied to the CT projection images and maximum intensity projection. Observers including breast radiologists and medical imaging experts compared the quality of the reconstructed images with reference images approximating the conventional (absorption) CT. Various radiological image quality attributes in a visual grading analysis design were used for the radiological assessments. RESULTS: The results show that the application of the longest achievable sample-to-detector distance (9.31 m), the lowest employed X-ray energy (32 keV), the full phase retrieval, and the maximum intensity projection can significantly improve the radiological quality of the image. Several combinations of imaging variables resulted in images with very high-quality scores. CONCLUSION: The results of the present study will support future experimental and clinical attempts to further optimize this innovative approach to breast cancer imaging.


Subject(s)
Breast Neoplasms/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Mammography/methods , Tomography, X-Ray Computed/methods , Aged , Algorithms , Breast/diagnostic imaging , Female , Humans
8.
J Synchrotron Radiat ; 25(Pt 5): 1460-1466, 2018 Sep 01.
Article in English | MEDLINE | ID: mdl-30179186

ABSTRACT

The aim of this study was to highlight the advantages that propagation-based phase-contrast computed tomography (PB-CT) with synchrotron radiation can provide in breast cancer diagnostics. For the first time, a fresh and intact mastectomy sample from a 60 year old patient was scanned on the IMBL beamline at the Australian Synchrotron in PB-CT mode and reconstructed. The clinical picture was described and characterized by an experienced breast radiologist, who underlined the advantages of providing diagnosis on a PB-CT volume rather than conventional two-dimensional modalities. Subsequently, the image quality was assessed by 11 breast radiologists and medical imaging experts using a radiological scoring system. The results indicate that, with the radiation dose delivered to the sample being equal, the accuracy of a diagnosis made on PB-CT images is significantly higher than one using conventional techniques.


Subject(s)
Breast Neoplasms/diagnostic imaging , Synchrotrons , Tomography, X-Ray Computed/methods , Breast Neoplasms/surgery , Female , Humans , In Vitro Techniques , Mastectomy , Middle Aged , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Signal-To-Noise Ratio
9.
IEEE Trans Med Imaging ; 37(12): 2642-2650, 2018 12.
Article in English | MEDLINE | ID: mdl-29994112

ABSTRACT

Histopathological analysis is the current gold standard in breast cancer diagnosis and management, however, as imaging technology improves, the amount of potential diagnostic information that may be demonstrable radiologically should also increase. We aimed to evaluate the potential clinical usefulness of 3-D phase-contrast micro-computed tomography (micro-CT) imaging at high spatial resolutions as an adjunct to conventional histological microscopy. Ten breast tissue specimens, 2 mm in diameter, were scanned at the SYRMEP beamline of the Elettra Synchrotron using the propagation-based phase-contrast micro-tomography method. We obtained pixel size images, which were analyzed and compared with corresponding histological sections examined under light microscopy. To evaluate the effect of spatial resolution on breast cancer diagnosis, scans with four different pixel sizes were also performed. Our comparative analysis revealed that high-resolution images can enable, at a near-histological level, detailed architectural assessment of tissue that may permit increased breast cancer diagnostic sensitivity and specificity when compared with current imaging practices. The potential clinical applications of this method are also discussed.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast/diagnostic imaging , Imaging, Three-Dimensional/methods , X-Ray Microtomography/methods , Aged, 80 and over , Algorithms , Female , Humans , Middle Aged
10.
Nanoscale ; 9(29): 10447-10464, 2017 Jul 27.
Article in English | MEDLINE | ID: mdl-28703833

ABSTRACT

Significant efforts are being undertaken to optimize the cargo carrying capacity and especially the cellular delivery efficiency of functionalized nanoparticles for applications in biological research and pharmacological delivery. One approach to increasing nanoparticle surface cargo display capacity is to decrease the number of moieties required for mediating cellular delivery by improving their efficiency. We describe a series of multivalent cell penetrating peptide (CPP) dendrimers that facilitate rapid cellular delivery of prototypical nanoparticle-semiconductor quantum dots (QDs). The modular CPP dendrimers were assembled through an innovative convergent oxime ligation strategy between (Arg9)n motifs and a dendritic QD-coordination scaffold. Dendrimeric peptides sequentially incorporate a terminal (His)6 motif for metal-affinity QD coordination, a Pro9 spacer, a branching poly-lysine scaffold, and wedged display of (Arg9)n binding motifs with n = 1×, 2×, 4×, 8×, 16× multivalency. QD dendrimer display capacity was estimated using structural simulations and QD-(Arg9)1-16 conjugates characterized by dynamic light scattering along with surface plasmon resonance-based binding assays to heparan sulfate proteoglycan surfaces. Cellular uptake via endocytosis was confirmed and peptide delivery kinetics investigated as a function of QD-(Arg9)1-16 conjugate exposure time and QD assembly ratio where cellular viability assays reflected no overt cytotoxicity. The ability of single dendrimer conjugates to facilitate cellular uptake was confirmed for QD-(Arg9)2-16 repeats along with the ability to deliver >850 kDa of protein cargo per QD. Minimizing the number of CPPs required for cellular uptake is critical for expanding nanoparticle cargo carrying capacity and can allow for inclusion of additional sensors, therapeutics and contrast agents on their surface.


Subject(s)
Cell-Penetrating Peptides/chemistry , Dendrimers/chemistry , Nanoparticles/chemistry , Quantum Dots , Animals , Biological Transport , COS Cells , Chlorocebus aethiops , Endocytosis
11.
J Pept Sci ; 22(5): 311-9, 2016 May.
Article in English | MEDLINE | ID: mdl-27005702

ABSTRACT

A new class of arginine-specific bioconjugation reagents for protein labeling has been developed. This method utilizes a triazolyl-phenylglyoxal group on the probe molecule that reacts selectively with the guandinyl group of Arg residues in a protein or peptide. The reaction proceeds in neutral to basic bicarbonate buffers and is selective for arginine residues in peptides and folded proteins. Importantly, the triazolyl-phenylglyoxal group can be introduced into complex molecules containing alkyne groups using CuAAC chemistry, providing a robust approach for the generation of phenylglyoxal reactive groups into molecules to be covalently attached onto the surface of proteins. Copyright © 2016 European Peptide Society and John Wiley & Sons, Ltd.


Subject(s)
Arginine/metabolism , Molecular Probes/chemical synthesis , Peptides/chemistry , Proteins/chemistry , Triazoles/chemistry , Indicators and Reagents , Molecular Probes/chemistry , Molecular Probes/metabolism , Molecular Structure , Phenylglyoxal/chemistry , Protein Folding
12.
J Synchrotron Radiat ; 22(6): 1509-23, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26524316

ABSTRACT

Results are presented of a recent experiment at the Imaging and Medical beamline of the Australian Synchrotron intended to contribute to the implementation of low-dose high-sensitivity three-dimensional mammographic phase-contrast imaging, initially at synchrotrons and subsequently in hospitals and medical imaging clinics. The effect of such imaging parameters as X-ray energy, source size, detector resolution, sample-to-detector distance, scanning and data processing strategies in the case of propagation-based phase-contrast computed tomography (CT) have been tested, quantified, evaluated and optimized using a plastic phantom simulating relevant breast-tissue characteristics. Analysis of the data collected using a Hamamatsu CMOS Flat Panel Sensor, with a pixel size of 100 µm, revealed the presence of propagation-based phase contrast and demonstrated significant improvement of the quality of phase-contrast CT imaging compared with conventional (absorption-based) CT, at medically acceptable radiation doses.


Subject(s)
Breast Neoplasms/diagnostic imaging , Image Enhancement/instrumentation , Imaging, Three-Dimensional/instrumentation , Mammography/instrumentation , Synchrotrons/instrumentation , X-Ray Diffraction/instrumentation , Equipment Design , Equipment Failure Analysis , Feasibility Studies , Female , Humans , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity , Tomography, Optical/instrumentation
13.
Adv Exp Med Biol ; 823: 191-205, 2015.
Article in English | MEDLINE | ID: mdl-25381109

ABSTRACT

This chapter describes a novel way of carrying out image analysis, reconstruction and processing tasks using cloud based service provided on the Australian National eResearch Collaboration Tools and Resources (NeCTAR) infrastructure. The toolbox allows users free access to a wide range of useful blocks of functionalities (imaging functions) that can be connected together in workflows allowing creation of even more complex algorithms that can be re-run on different data sets, shared with others or additionally adjusted. The functions given are in the area of cellular imaging, advanced X-ray image analysis, computed tomography and 3D medical imaging and visualisation. The service is currently available on the website www.cloudimaging.net.au .


Subject(s)
Diagnostic Imaging/methods , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Software , Biomedical Research/methods , Brain Neoplasms/diagnosis , Brain Neoplasms/diagnostic imaging , Humans , Internet , Medical Oncology/methods , Neurites/diagnostic imaging , Neurosciences/methods , Reproducibility of Results , Sensitivity and Specificity , Tomography, X-Ray Computed , X-Rays
14.
Acta Crystallogr D Biol Crystallogr ; 70(Pt 8): 2232-40, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25084341

ABSTRACT

Under physiological conditions, the pentameric human plasma protein serum amyloid P component (SAP) binds hexanoyl bis(D-proline) (R-1-{6-[R-2-carboxy-pyrrolidin-1-yl]-6-oxo-hexanoyl}pyrrolidine-2-carboxylic acid; CPHPC) through its D-proline head groups in a calcium-dependent interaction. Cooperative effects in binding lead to a substantial enhancement of affinity. Five molecules of the bivalent ligand cross-link and stabilize pairs of SAP molecules, forming a decameric complex that is rapidly cleared from the circulation by the liver. Here, it is reported that X-ray analysis of the SAP complex with CPHPC and cadmium ions provides higher resolution detail of the interaction than is observed with calcium ions. Conformational isomers of CPHPC observed in solution by HPLC and by X-ray analysis are compared with the protein-bound form. These are discussed in relation to the development of CPHPC to provide SAP depletion for the treatment of amyloidosis and other indications.


Subject(s)
Proline/chemistry , Serum Amyloid P-Component/chemistry , Calcium/chemistry , Calorimetry , Chromatography, High Pressure Liquid , Crystallography, X-Ray , Proline/analogs & derivatives , Protein Conformation , Thermodynamics
15.
Front Neuroinform ; 8: 30, 2014.
Article in English | MEDLINE | ID: mdl-24734019

ABSTRACT

The Multi-modal Australian ScienceS Imaging and Visualization Environment (MASSIVE) is a national imaging and visualization facility established by Monash University, the Australian Synchrotron, the Commonwealth Scientific Industrial Research Organization (CSIRO), and the Victorian Partnership for Advanced Computing (VPAC), with funding from the National Computational Infrastructure and the Victorian Government. The MASSIVE facility provides hardware, software, and expertise to drive research in the biomedical sciences, particularly advanced brain imaging research using synchrotron x-ray and infrared imaging, functional and structural magnetic resonance imaging (MRI), x-ray computer tomography (CT), electron microscopy and optical microscopy. The development of MASSIVE has been based on best practice in system integration methodologies, frameworks, and architectures. The facility has: (i) integrated multiple different neuroimaging analysis software components, (ii) enabled cross-platform and cross-modality integration of neuroinformatics tools, and (iii) brought together neuroimaging databases and analysis workflows. MASSIVE is now operational as a nationally distributed and integrated facility for neuroinfomatics and brain imaging research.

16.
Biopolymers ; 102(3): 273-9, 2014 May.
Article in English | MEDLINE | ID: mdl-24599728

ABSTRACT

Chemoselective protein labeling remains a significant challenge in chemical biology. Although many selective labeling chemistries have been reported, the practicalities of matching the reaction with appropriately functionalized proteins and labeling reagents is often a challenge. For example, we encountered the challenge of site specifically labeling the cellular form of the murine Prion protein with a fluorescent dye. To facilitate this labeling, a protein was expressed with site specific p-acetylphenylalanine. However, the utility of this acetophenone reactive group is hampered by the severe lack of commercially available aminooxy fluorophores. Here we outline a general strategy for the efficient solid phase synthesis of adapter reagents capable of converting maleimido-labels into aminooxy or azide functional groups that can be further tuned for desired length or solubility properties. The utility of the adapter strategy is demonstrated in the context of fluorescent labeling of the murine Prion protein through an adapted aminooxy-Alexa dye.


Subject(s)
Coloring Agents/metabolism , Prions/metabolism , Staining and Labeling , Amino Acid Sequence , Animals , Chromatography, High Pressure Liquid , Chromatography, Reverse-Phase , Electrophoresis, Polyacrylamide Gel , Indicators and Reagents , Mice , Molecular Sequence Data , Peptides/chemistry
17.
ACS Nano ; 7(5): 3778-96, 2013 May 28.
Article in English | MEDLINE | ID: mdl-23710591

ABSTRACT

Cell penetrating peptides facilitate efficient intracellular uptake of diverse materials ranging from small contrast agents to larger proteins and nanoparticles. However, a significant impediment remains in the subsequent compartmentalization/endosomal sequestration of most of these cargoes. Previous functional screening suggested that a modular peptide originally designed to deliver palmitoyl-protein thioesterase inhibitors to neurons could mediate endosomal escape in cultured cells. Here, we detail properties relevant to this peptide's ability to mediate cytosolic delivery of quantum dots (QDs) to a wide range of cell-types, brain tissue culture and a developing chick embryo in a remarkably nontoxic manner. The peptide further facilitated efficient endosomal escape of large proteins, dendrimers and other nanoparticle materials. We undertook an iterative structure-activity relationship analysis of the peptide by discretely modifying key components including length, charge, fatty acid content and their order using a comparative, semiquantitative assay. This approach allowed us to define the key motifs required for endosomal escape, to select more efficient escape sequences, along with unexpectedly identifying a sequence modified by one methylene group that specifically targeted QDs to cellular membranes. We interpret our results within a model of peptide function and highlight implications for in vivo labeling and nanoparticle-mediated drug delivery by using different peptides to co-deliver cargoes to cells and engage in multifunctional labeling.


Subject(s)
Cell-Penetrating Peptides/chemistry , Cytosol/metabolism , Drug Carriers/chemistry , Maltose-Binding Proteins/metabolism , Quantum Dots , Amino Acid Motifs , Amino Acid Sequence , Animals , Cell Line , Cell-Penetrating Peptides/metabolism , Chick Embryo , Drug Carriers/metabolism , Endosomes/metabolism , Humans , Molecular Sequence Data
18.
Nat Chem Biol ; 8(8): 725-30, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22729149

ABSTRACT

Most of our understanding of G protein-coupled receptor (GPCR) activation has been focused on the direct interaction between diffusible ligands and their seven-transmembrane domains. However, a number of these receptors depend on their extracellular N-terminal domain for ligand recognition and activation. To dissect the molecular interactions underlying both modes of activation at a single receptor, we used the unique properties of the melanocortin-4 receptor (MC4R), a GPCR that shows constitutive activity maintained by its N-terminal domain and is physiologically activated by the peptide α-melanocyte stimulating hormone (αMSH). We find that activation by the N-terminal domain and αMSH relies on different key residues in the transmembrane region. We also demonstrate that agouti-related protein, a physiological antagonist of MC4R, acts as an inverse agonist by inhibiting N terminus-mediated activation, leading to the speculation that a number of constitutively active orphan GPCRs could have physiological inverse agonists as sole regulators.


Subject(s)
Receptor, Melanocortin, Type 4/metabolism , Agouti-Related Protein/metabolism , Cell Membrane , Gene Expression Regulation/physiology , HEK293 Cells , Humans , Models, Molecular , Plasmids , Protein Conformation , Protein Structure, Tertiary , Receptor, Melanocortin, Type 4/agonists , Receptor, Melanocortin, Type 4/genetics , alpha-MSH/genetics , alpha-MSH/metabolism
19.
Med Eng Phys ; 33(5): 590-6, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21239209

ABSTRACT

Additive manufacturing, covering processes frequently referred to as rapid prototyping and rapid manufacturing, provides new opportunities in the manufacture of highly complex and custom-fitting medical devices and products. Whilst many medical applications of AM have been explored and physical properties of the resulting parts have been studied, the characterisation of AM materials in computed tomography has not been explored. The aim of this study was to determine the CT number of commonly used AM materials. There are many potential applications of the information resulting from this study in the design and manufacture of wearable medical devices, implants, prostheses and medical imaging test phantoms. A selection of 19 AM material samples were CT scanned and the resultant images analysed to ascertain the materials' CT number and appearance in the images. It was found that some AM materials have CT numbers very similar to human tissues, FDM, SLA and SLS produce samples that appear uniform on CT images and that 3D printed materials show a variation in internal structure.


Subject(s)
Manufactured Materials , Tomography, X-Ray Computed/methods , Artifacts , Computer-Aided Design/instrumentation , Humans , Phantoms, Imaging , Water
20.
Proc Natl Acad Sci U S A ; 107(47): 20164-71, 2010 Nov 23.
Article in English | MEDLINE | ID: mdl-20980662

ABSTRACT

Background adaptation is used by teleosts as one of a variety of camouflage mechanisms for avoidance of predation. Background adaptation is known to involve light sensing by the retina and subsequent regulation of melanophore dispersion or contraction in melanocytes, mediated by α-melanocyte-stimulating hormone and melanin-concentrating hormone, respectively. Here, we demonstrate that an agouti gene unique to teleosts, agrp2, is specifically expressed in the pineal and is required for up-regulation of hypothalamic pmch and pmchl mRNA and melanosome contraction in dermal melanocytes in response to a white background. floating head, a mutant with defective pineal development, exhibits defective up-regulation of mch mRNAs by white background, whereas nrc, a blind mutant, exhibits a normal response. These studies identify a role for the pineal in background adaptation in teleosts, a unique physiological function for the agouti family of proteins, and define a neuroendocrine axis by which environmental background regulates pigmentation.


Subject(s)
Adaptation, Physiological/genetics , Agouti-Related Protein/metabolism , Pigmentation/genetics , Pineal Gland/metabolism , Zebrafish/metabolism , Animals , Gene Expression Regulation/physiology , Melanosomes/metabolism , Pigmentation/physiology , Receptor, Melanocortin, Type 1/antagonists & inhibitors , Zebrafish/genetics
SELECTION OF CITATIONS
SEARCH DETAIL
...