Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Publication year range
1.
Sensors (Basel) ; 23(8)2023 Apr 07.
Article in English | MEDLINE | ID: mdl-37112125

ABSTRACT

Frequency estimation plays a critical role in vital sign monitoring. Methods based on Fourier transform and eigen-analysis are commonly adopted techniques for frequency estimation. Because of the nonstationary and time-varying characteristics of physiological processes, time-frequency analysis (TFA) is a feasible way to perform biomedical signal analysis. Among miscellaneous approaches, Hilbert-Huang transform (HHT) has been demonstrated to be a potential tool in biomedical applications. However, the problems of mode mixing, unnecessary redundant decomposition and boundary effect are the common deficits that occur during the procedure of empirical mode decomposition (EMD) or ensemble empirical mode decomposition (EEMD). The Gaussian average filtering decomposition (GAFD) technique has been shown to be appropriate in several biomedical scenarios and can be an alternative to EMD and EEMD. This research proposes the combination of GAFD and Hilbert transform that is termed the Hilbert-Gauss transform (HGT) to overcome the conventional drawbacks of HHT in TFA and frequency estimation. This new method is verified to be effective for the estimation of respiratory rate (RR) in finger photoplethysmography (PPG), wrist PPG and seismocardiogram (SCG). Compared with the ground truth values, the estimated RRs are evaluated to be of excellent reliability by intraclass correlation coefficient (ICC) and to be of high agreement by Bland-Altman analysis.


Subject(s)
Algorithms , Respiratory Rate , Reproducibility of Results , Photoplethysmography/methods , Normal Distribution , Signal Processing, Computer-Assisted
2.
Micromachines (Basel) ; 12(9)2021 Aug 24.
Article in English | MEDLINE | ID: mdl-34577651

ABSTRACT

We propose a novel liquid jet gyroscope based on electrochemical transducers, which uses electrolyte as the jet medium, and two electrochemical transducers placed symmetrically as the velocity measuring unit. The gyroscope includes a fluid pump to generate a jet flow, which flows into the jet chamber. Then, it is diverged into the shunt channels, pumped into reflux channels and merged by a fluid pump. The velocities of shunt flows are measured by two electrochemical transducers. The feasibility of the method was demonstrated in theory, and a 2D finite element model was built to simulate the dynamics of the liquid jet gyroscope. Simulation results confirm the effectiveness of the gyroscope, which has higher sensitivity in the near DC frequency band.

3.
Sensors (Basel) ; 18(3)2018 Mar 13.
Article in English | MEDLINE | ID: mdl-29534007

ABSTRACT

Magnetic resonance sounding (MRS) is a novel geophysical method to detect groundwater directly. By applying this method to underground projects in mines and tunnels, warning information can be provided on water bodies that are hidden in front prior to excavation and thus reduce the risk of casualties and accidents. However, unlike its application to ground surfaces, the application of MRS to underground environments is constrained by the narrow space, quite weak MRS signal, and complex electromagnetic interferences with high intensities in mines. Focusing on the special requirements of underground MRS (UMRS) detection, this study proposes the use of an antenna with different turn numbers, which employs a separated transmitter and receiver. We designed a stationary coil with stable performance parameters and with a side length of 2 m, a matching circuit based on a Q-switch and a multi-stage broad/narrowband mixed filter that can cancel out most electromagnetic noise. In addition, noises in the pass-band are further eliminated by adopting statistical criteria and harmonic modeling and stacking, all of which together allow weak UMRS signals to be reliably detected. Finally, we conducted a field case study of the UMRS measurement in the Wujiagou Mine in Shanxi Province, China, with known water bodies. Our results show that the method proposed in this study can be used to obtain UMRS signals in narrow mine environments, and the inverted hydrological information generally agrees with the actual situation. Thus, we conclude that the UMRS method proposed in this study can be used for predicting hazardous water bodies at a distance of 7-9 m in front of the wall for underground mining projects.

4.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 23(5): 974-6, 2006 Oct.
Article in Chinese | MEDLINE | ID: mdl-17121334

ABSTRACT

The adaptive filter is an effective method to dealing with such kind of non-steady random signal of the heart rate. The algorithm of clipped- error LMS algorithm with variable step size of segmenting type was proposed. We adopted auto-regression predict filter estimating the noise of heart rate signals through Doppler ultrasound sensor. We used it as the reference signal of the adaptive noise cancelling system, its result is to remove some noise of main input, it made SNR raise by about 36 dB, it realized the abstraction of the heart rate signals.


Subject(s)
Heart Rate/physiology , Signal Processing, Computer-Assisted , Algorithms , Echocardiography, Doppler , Humans , Least-Squares Analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...