Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 40
Filter
1.
Orthop Rev (Pavia) ; 16: 117203, 2024.
Article in English | MEDLINE | ID: mdl-38751453

ABSTRACT

INTRODUCTION The incidence of periprosthetic fractures (PFFs) is estimated to range from 0.1% to 4.1%1, due to the increasing prevalence of joint arthroplasties, coupled with an aging population. Numerous risk factors, including advanced age (>80 years), female gender, implant type, prior diagnoses of osteonecrosis and rheumatoid arthritis, revision surgery, aseptic stem mobilization, and the use of non-cemented stems, have been identified. Survivors of periprosthetic fractures often experience functional deterioration, facing a fourfold higher risk of hospitalization for postoperative complications compared to patients undergoing primary implantation, especially in the first postoperative year. MATERIALS AND METHODS Between 2018 and 2022, at the Maggiore Hospitals in Bologna and the San Matteo Policlinic in Pavia, we performed osteosynthesis on 84 patients with periprosthetic fractures of Vancouver type B1 or C. In 38 patients, we employed angular stable plates with the Zimmer Biomet NCB-PP® system. In 46 patients, we utilized INTRAUMA plates: DF distal femur and PFF proximal. Relevant postoperative follow-up outcomes considered included reintervention, infectious complications, radiographic healing, and functional recovery, with reference to changes in the Glasgow Outcome Scale (GOS) and the Harris Hip Score (HHS). All patients underwent clinical and radiographic evaluations during the follow-up period, averaging 28 months (range: 12-48 months), with a minimum follow-up duration of 12 months. RESULTS At the 4-month postoperative assessment, 71% of patients maintained their preoperative functional level, 19% experienced a 1-point GOS scale drop, and 10% died (GOS 5). The average HHS at 4 months was 80.2 points (range: 65-90). At the 6-month follow-up, 98.2% of patients achieved complete healing on radiographic examination. Only 1 patient (1.2%) developed a pseudoarthrosis site with synthesis device rupture. Only 1 patient (1.2%) required additional surgical treatment 2 years later due to the development of un aseptic perisynthetic fluid collection, while the remaining 5 patients (6%) who developed complications benefited from conservative treatment: 4 patients (3.6%) with infectious complications were treated with intravenous antibiotics. In the 2 patients (2.3%) with mobilization or rupture of synthesis devices, clinical and radiographic monitoring was opted for. 8 patients (10.7%) died: one 48 hours after the surgery, and the other 7 more than one month after the surgery. CONCLUSION Our clinical findings align with to existing scientific literature on periprosthetic fractures (B1 and C according to Vancouver classification). Moreover, good stability has been guaranteed at the radiological follow up by Zimmer Biomet NCB-PP® and INTRAUMA DF distal femur and PFF proximal plates. The locking construct allows for improved stability especially in osteoporotic bone.

2.
SICOT J ; 10: 9, 2024.
Article in English | MEDLINE | ID: mdl-38415767

ABSTRACT

INTRODUCTION: Lateral fractures of proximal femur are the most frequent fractures in elderly people. Internal fixation using medullary nails is the gold standard of treatment (Gamma 3 nail is the most implanted device) due to reduced incidence of complications than other devices. We report our experience in treating this kind of fractures with Gamma 3 nail, between January 2015 and December 2021. METHODS: We performed a retrospective cohort study of patients treated in our orthopaedic department; level of clinical care is III: 559 patients (431 females and 128 males, with an average age of 85.3 years) with lateral femoral neck fracture. All patients were surgically treated with Gamma 3 standard nail (SGN). We evaluated preliminary X-rays to classify fractures, according to AO-OTA classification and post-operative X-ray to verify cephalic screw position site, according to areas described by Cleveland in 1959: we measured tip-to-apex distance (TAD) and tip-to-apex calcar referred distance (CalTAD). Finally Chang reduction quality criteria (CRQC) for fracture reduction of trochanteric fractures were determined using preoperative or postoperative Antero-Posterior (AP) and lateral radiographs in a Picture Archiving and Communication System (PACS). Incidence of cut-out was evaluated in relation with these parameters. Patients were divided into 2 groups: first group had cephalic screw in optimal positions (5-8-9), the other group had cephalic screw in other positions. RESULTS: In 328 patients (58.7%) screw was in positions 5-8-9, in 231 patients (41.2%) screw was in not-optimal position. Median TAD was 19.1 ± 7.0 mm (range = 0.0-50.5); in 463 patients (82.8%) TAD was ≤ 25 mm. Median CalTAD was 21.4 ± 4.7 mm (range = 5.7-39.2); in 105 patients (79.4%) CalTAD was ≤ 25 mm. Cut-out was observed in 8 cases (1.43%). Multivariate analysis showed a significant correlation (p < 0,05) between incidence of cut-out and fracture type 31A2 and with TAD values >25 mm. Cephalic screw position did not influence incidence of cut-out. DISCUSSION: In order to obtain fracture healing with a low risk of failure, in particular cut-out, it is necessary to obtain good reduction of fracture and optimal lag screw position in order to achieve a TAD inferior to 25 mm.

3.
Orthopedics ; 46(5): e273-e280, 2023.
Article in English | MEDLINE | ID: mdl-37561099

ABSTRACT

Although total hip arthroplasty (THA) is considered a successful procedure, hip dislocation remains the main cause of early failure. Dual mobility cups (DMCs) have been shown to significantly reduce the dislocation rate in both primary and revision THAs. During the past several decades, DMCs have evolved in design and fixation interface. There have been three generations of DMCs. This article addresses the rationale for a new cementless highly porous titanium DMC to improve component fixation and implant biocompatibility. [Orthopedics. 2023;46(5):e273-e280.].


Subject(s)
Arthroplasty, Replacement, Hip , Hip Dislocation , Hip Prosthesis , Humans , Hip Prosthesis/adverse effects , Reoperation/adverse effects , Prosthesis Design , Arthroplasty, Replacement, Hip/adverse effects , Hip Dislocation/surgery , Prosthesis Failure , Retrospective Studies
4.
J Orthop Surg Res ; 18(1): 278, 2023 Apr 05.
Article in English | MEDLINE | ID: mdl-37020227

ABSTRACT

PURPOSE: The use of dual mobility cups in total hip arthroplasty has gained popularity in light of the fact it enables to reduce dislocation through increased jumping distance (JD) and impingement-free arc of movement. Modular Dual Mobility Cup (modular DMC) systems have been recently introduced to enable the use of dual mobility cups with standard metal-backed shells. The objective of this study was twofold: calculate the JD for each modular DMC system and conduct a systematic literature review to report clinical outcomes and reasons for failure of this construct. METHODS: The JD was calculated using the Sariali formula: JD = 2Rsin [(π/2 - Ψ - arcsin (offset/R))/2]. A qualitative systematic literature review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A comprehensive search for English and French articles between January 2000 and July 2020 was run on PubMed, EMBASE, Google Scholar, and Scopus with the primary objective of finding articles about modular DMC systems. RESULTS: We identified eight 8 different manufacturers of modular DMC systems and 327 publications on the subject. After screening for duplicates and eligibility, we identified 229 publications: 206 articles were excluded because they contained no reports on modular DMC systems, whereas other three were not included because they focused on biomechanical aspects. Among the 11 included articles, 2 were prospective case series, 9 were retrospective case series. True dislocation occurred in 25 cases (0.9%), and six of them were solved by closed reduction without necessity of revision, while all 5 intraprosthetic dislocations were operated. CONCLUSIONS: Modular DMCs are a valid method to deal with complex THA instability, with good clinical and patient-reported outcomes, low complication rates, and low revision rates at early follow-up. We would advise cautious optimism on the role of modular DMC implants, as it seems safer to use ceramic instead of metallic heads whenever possible to avoid the increase cobalt and chromium trace ion serum levels.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Dislocation , Hip Prosthesis , Joint Dislocations , Humans , Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Retrospective Studies , Prosthesis Failure , Prosthesis Design , Reoperation/adverse effects , Hip Dislocation/surgery , Joint Dislocations/surgery
5.
Int Orthop ; 47(1): 99-106, 2023 01.
Article in English | MEDLINE | ID: mdl-36449052

ABSTRACT

PURPOSE: The purpose of the study was to investigate the outcome of dual-mobility cup (DM) compared with a standard cup (SC) in primary total hip arthroplasty (THA) in the long-term follow-up based on a regional Italian joint registry (RIPO). METHODS: The Registry of Prosthetic Orthopaedic Implant (RIPO) was consulted, looking for all primary THAs implanted from 2000 to 2019. Three thousand seven hundred ten were dual-mobility cup (DM) total hip arthroplasties (THA) and 85.816 were standard cup (SC) THAs, on a total of 89.526 primary THA. Demographics, survival rates and causes of revision were evaluated and compared between the two groups. RESULTS: The use of DM progressively increased from 0.4% in 2000 to 7.5% in 2018 of all primary THAs. Revision rate was 3.5% (128 on 3710) for DMC and 4.7% (4061 on 85,816) for SC. DM presented lower dislocation rate if compared to SC with 22-28-mm femoral head diameter. However, DM showed a higher risk of revision for any causes than SC with 32-mm femoral head diameter in long-term follow-up. Nevertheless, no significant difference was measured in terms of demographics and surgical approach for dislocation rate. CONCLUSIONS: The DM cup represents a valid implant solution and has a lower dislocation rate than 22-28-mm SC. A slight increase in the use of DM implants over time was observed in the RIPO. However, a larger population and a longer follow-up are needed to further monitor the survival rate of new-generation DM implants.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Dislocation , Hip Prosthesis , Joint Dislocations , Orthopedics , Humans , Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Prosthesis Failure , Prosthesis Design , Reoperation/adverse effects , Hip Dislocation/surgery , Joint Dislocations/surgery , Registries , Retrospective Studies , Follow-Up Studies
6.
BMC Musculoskelet Disord ; 23(1): 373, 2022 Apr 20.
Article in English | MEDLINE | ID: mdl-35443656

ABSTRACT

BACKGROUND: Use of dual mobility (DM) in total hip arthroplasty has gained popularity due to the ability to reduce dislocation through increased jumping distance and impingement-free arc of movement. Recently, modular dual mobility (modDM) systems were introduced to give the possibility to use DM with standard metal-backed shells, however few has been studied to date regarding how jumping distance and the center of rotation change with modDM. The objective of this study was to evaluate, through analytical simulation, how jumping distance, center of rotation and arc of movement change between DM and standard cups with modDM or fixed bearings (FB). METHODS: 3D-models of DM and standard press-fit cups with modDM or FB liners were used to simulate DM, modDM and FB implant configurations, matched for same cup size, according to same cup position and different femoral head diameters. Jumping distance was calculated and center of rotation lateralization and oscillation angles were measured for each size of these three implant configurations. RESULTS: Jumping distance with modDM was reduced by -3.9 mm to -8.6 mm in comparison with DM, from 48 to 64 mm size, but resulted comparable to polyethylene 36 mm FB and increased by + 1.1 mm and + 1.4 mm than ceramic 36 and 40 mm FBs for sizes > 54 mm. ModDM lateralized the center of rotation up to + 2.5 mm and + 4.0 mm in comparison with DM and FBs, respectively. Oscillation angle with modDM resulted higher than + 16°, + 23°, + 17° and + 14° in comparison to DM, 28 mm, 32 mm and 36 mm FB cups, respectively, for 56 mm cup size. CONCLUSIONS: According to its specific design, modDM might change hip stability parameters in comparison to DM, worsening jumping distance and center of rotation position, but increasing arc of movement. As not restoring stability parameters in the same fashion, modDM implants should be properly used when DM cups are not feasible.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Dislocation , Hip Prosthesis , Hip Dislocation/surgery , Humans , Prosthesis Design , Prosthesis Failure , Reoperation
7.
Artif Organs ; 46(5): 804-812, 2022 May.
Article in English | MEDLINE | ID: mdl-34153137

ABSTRACT

Although total hip arthroplasty (THA) has shown successful results, instability remains a major complication. In recent years, dual mobility cups (DMC) have gained interest among clinicians thanks to its low rate of dislocation and good clinical results. The main aim of this work was to describe the accuracy of data on DMC from national and regional joint registries (JRs) and the available worldwide literature. We identified topics on DMC among JRs to propose a new harmonized and standardized section for DMC with the aim to understand its surveillance over the time. We extracted survival and implant data for a separate analysis. After performing a critical exclusion process, nine JRs were considered eligible and included for final synthesis; these were the results from the available worldwide data from JRs. In our study, eight analyzed JRs reported a slight increase in DMC use in the last decade. In all the JRs evaluated and the available articles, dislocation remains one of the main reasons for revision and re-revision in hip arthroplasties. DMC is considered to be a valid construct increasingly used worldwide in primary and revision THA with the primary aim of reducing dislocation rates. Annual reports from JRs collect heterogeneous and low-quality information about outcomes and surveillance of DMC, creating a burden for clinicians to extract comparable data from different JRs. Longer follow-up and a systematic registering of DMCs with international registry harmonization are needed to monitor DMC outcomes.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Dislocation , Hip Prosthesis , Joint Dislocations , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Hip Dislocation/complications , Hip Dislocation/surgery , Hip Joint/surgery , Hip Prosthesis/adverse effects , Humans , Joint Dislocations/surgery , Prosthesis Design , Prosthesis Failure , Registries , Reoperation , Retrospective Studies
8.
J Clin Med ; 12(1)2022 Dec 20.
Article in English | MEDLINE | ID: mdl-36614821

ABSTRACT

INTRODUCTION: Calcaneal fractures (CF) are the most common tarsal fractures, representing up to 75% of foot fractures and 2% of all fractures. The aim of this retrospective study is to analyze fixation with Kirschner wires through a mini-invasive approach and dedicated plate and screws through an extended approach at long-term follow-up. MATERIALS AND METHODS: Patients were radiographically and clinically evaluated at final follow-up, by using the validated American Orthopedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score for the clinical-functional assessment, the Short-Form 12 (SF-12) for the physical and psychological domain assessment, and the Visual Analog Scale (VAS) for pain. RESULTS: In total, 38 patients (42 CF) met the inclusion criteria and were retrospectively evaluated and divided into two groups (Kirschner group and plate group) consisting of 19 patients each. The overall mean follow-up was 59.4 ± 11.8 months. The average values of the post-operative clinical outcomes of the two groups KG and PG were, respectively, 70.7 ± 11.9 and 70.1 ± 10.9 (AOFAS), 45.7 ± 6.8 and 46.5 ± 10.8 (SF-12 PCS), 54.7 ± 9.9 and 50.9 ± 11.8 (SF-12 MCS) at the final follow-up. CONCLUSIONS: The present study showed that in the cases analyzed, the two surgical approaches used for the treatment of CF achieved comparable clinical outcomes. The only substantial difference found between the two groups of patients was the re-intervention rate that afflicted them.

9.
Acta Biomed ; 92(4): e2021290, 2021 09 02.
Article in English | MEDLINE | ID: mdl-34487106

ABSTRACT

Preoperative management of acetabular fracture is a major problem and no consensus has been reached in literature on the optimal treatment of this problem. We present the results of the First Italian Consensus Conference on Acetabular fracture. An extensive review of the literature has been undertaken by the organizing committee and forwarded to the panel. Members were appointed by surgical experience with acetabular fractures. From November 2017 to January 2018, the organizing committee undertook the critical revision and prepared the presentation to the Panel on the day of the Conference. Then 11 recommendations were presented according to the 11 submitted questions. The Panel voted the recommendations after discussion and amendments with the audience. Later on, a second debate took place in September 2018 to reach a unanimous consent. We present results of the following questions: does hip dislocation require reduction? Should hip reduction be performed as soon as possible? In case of unsuccessful reduction of the dislocation after attempts in the emergency department, how should it be treated? If there is any tendency toward renewed dislocation, how should it be treated? Should Computed Tomography (CT) scan be performed before reduction? Should traction be used? How can we treat the pain? Is preoperative ultrasound exam to rule out vein thrombosis always necessary? Is tranexamic acid intravenous (IV) preoperatively recommended? Which antibiotic prophylactic protocols should be used? Is any preoperative heterotopic ossification prophylaxis suggested? In this article we present the indications of the First Italian Consensus Conference: a hip dislocation should be reduced as soon as possible. If unsuccessful, surgeon may repeat the attempts optimizing the technique. Preoperative CT scan is not mandatory before reduction. Skeletal traction is not indicated in most of the acetabular fracture. Standard pain and antibiotic prophylactic protocols for trauma patient should be used. Preoperative ultrasound exam is not recommended in all acetabular fracture. Tranexamic acid should be preoperatively used. There is no indication for preoperative heterotopic ossification.


Subject(s)
Fractures, Bone , Hip Dislocation , Hip Fractures , Ossification, Heterotopic , Acetabulum/diagnostic imaging , Acetabulum/surgery , Fracture Fixation, Internal , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Humans , Italy , Treatment Outcome
11.
Materials (Basel) ; 13(9)2020 Apr 27.
Article in English | MEDLINE | ID: mdl-32349434

ABSTRACT

Revision of large-diameter, monoblock acetabular components for both hip resurfacing arthroplasty and metal-on-metal (MoM) total hip arthroplasty (THA) is correlated to a high amount of complications. For this reason, performing a limited revision by conversion to a dual mobility (DM) without acetabular component exchange has been proposed in order to limit these complications. Although DM bearing offers an easy solution avoiding the intraoperative and time-associated complications, concern about polyethylene wear and stability remains due to the difference regarding the design, the coverage angle and the clearance of the two implants. In order to evaluate the performance of this new solution with the new material to prevent the possibility of failure it is essential to conduct a review of the literature A qualitative systematic review of the literature has been conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A comprehensive search of PubMed, EMBASE, Google Scholar, and Scopus for English and French articles between January 2000 and October 2019 was performed, with the primary objective of finding articles about dual mobility bearing coupling with large metal-on-metal cup in the case of hip revision procedure. Various combinations of the key words were used in the search strategy. Thirteen articles with DM bearing mated with MoM cup were analyzed. Of the 130 hip revisions selected, with a follow-up from 6 to 53 months, there were a total of 14 with complications (10.77%): four true dislocations (3.08%); six intra-prosthetic dislocations (IPD, 4.6%), two of which presented plastic deformation and polyethylene wear; four other complications (3.08%), included a cup osteolysis, a clicking noise, a superficial infection and a periprosthetic fracture. All the mentioned true dislocations occurred during the first month while IPDs appeared during the first two years from the index revision. In conclusion, according to the literature analyzed, we can stress that the concerns and doubts about mating a DM bearing with large MoM cup cannot be dissolved. It has been pointed out that a DM bearing is not designed for a MoM cup; it is not mechanically tested on MoM cups, which presents different clearance and coverage angles. Predictable complications may occur, such as IPD, polyethylene wear and true dislocation. These complications have been reported at an even higher rate than they were in the eighties, when the first generation of DM implants were of a lower quality of polyethylene and the characteristic of the design was less optimal than modern ones.

13.
Cells ; 9(2)2020 02 11.
Article in English | MEDLINE | ID: mdl-32053901

ABSTRACT

Mutations in collagen VI genes cause two major clinical myopathies, Bethlem myopathy (BM) and Ullrich congenital muscular dystrophy (UCMD), and the rarer myosclerosis myopathy. In addition to congenital muscle weakness, patients affected by collagen VI-related myopathies show axial and proximal joint contractures, and distal joint hypermobility, which suggest the involvement of tendon function. To gain further insight into the role of collagen VI in human tendon structure and function, we performed ultrastructural, biochemical, and RT-PCR analysis on tendon biopsies and on cell cultures derived from two patients affected with BM and UCMD. In vitro studies revealed striking alterations in the collagen VI network, associated with disruption of the collagen VI-NG2 (Collagen VI-neural/glial antigen 2) axis and defects in cell polarization and migration. The organization of extracellular matrix (ECM) components, as regards collagens I and XII, was also affected, along with an increase in the active form of metalloproteinase 2 (MMP2). In agreement with the in vitro alterations, tendon biopsies from collagen VI-related myopathy patients displayed striking changes in collagen fibril morphology and cell death. These data point to a critical role of collagen VI in tendon matrix organization and cell behavior. The remodeling of the tendon matrix may contribute to the muscle dysfunction observed in BM and UCMD patients.


Subject(s)
Collagen Type VI/genetics , Contracture/genetics , Matrix Metalloproteinase 2/genetics , Muscular Dystrophies/congenital , Sclerosis/genetics , Antigens/genetics , Biopsy , Cell Polarity/genetics , Contracture/diagnostic imaging , Contracture/pathology , Extracellular Matrix/genetics , Extracellular Matrix/metabolism , Female , Fibroblasts/metabolism , Fibroblasts/pathology , Humans , Male , Muscle, Skeletal/pathology , Muscle, Skeletal/ultrastructure , Muscular Dystrophies/diagnostic imaging , Muscular Dystrophies/genetics , Muscular Dystrophies/pathology , Mutation/genetics , Proteoglycans/genetics , Sclerosis/diagnostic imaging , Sclerosis/pathology , Tendons/diagnostic imaging , Tendons/pathology , Tendons/ultrastructure
14.
J Clin Orthop Trauma ; 10(Suppl 1): S197-S200, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31695282

ABSTRACT

We report the case of treatment delay for an early onset of pulmonary embolism due to thrombosis in the femoral vein occurred in a traumatic anterior hip dislocation. Mistakes interpretations of clinical findings and pre-operative chest CT-angiography has endangered our patient's life because of the medical report was focused only on acute traumatic injuries. After all, we were not able to find in the literature any similar report that could explain the pathogenesis of this early onset and help us in the patient management. We have tried to list a number of practical suggestions to use in emergency room in these situations.

17.
Injury ; 48(10): 2311-2317, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28774706

ABSTRACT

Actually, pilon fractures are classified according to AO and Ruedi Allgower classification systems based on X-rays. These classifications are less reproducible and do not provide necessary information for proper surgical planning. Aim of the study is to (1) propose a new classification system based on CT scan; (2) to check the prognostic value of this classification and (3) to evaluate its reliability and (4) reproducibility. We retrospectively reviewed 71 cases of pilon fracture. All fractures were classified according to AO, Ruedi Allgower and new proposed classification system by 5 surgeons. Clinical and radiographic evaluation were performed at a mean follow-up of 36 months. Cohen's K value was calculated in order to evaluate the interobserver and intraobserver agreement. Sixty-four of 71 fractures healed. Average AOFAS score was 91,7±7,8 in the Type I of new classification proposed, 87,7±7,8 in the Type II, 82±18,6 in type III, and 67,2±20,9 in type IV. Using the AO classification system the average K weighted value among the five reviewers was 0,51; using Ruedi Allgower classification it was 0,50 and using the new classification system it was 0,88 (p<0.0005). This study demonstrated that the new classification system is prognostic, reliable and reproducible. Moreover it provides a new treatment-oriented classification for this challenging fracture which affect the quality of life of the patients more than chronic diseases like diabetes and coronaropathy or pelvic fractures.


Subject(s)
Ankle Fractures/diagnostic imaging , Preoperative Care , Tibial Fractures/diagnostic imaging , Tomography, X-Ray Computed , Adult , Aged , Ankle Fractures/classification , Ankle Fractures/surgery , Female , Follow-Up Studies , Fracture Fixation, Internal , Humans , Male , Middle Aged , Observer Variation , Quality of Life , Reproducibility of Results , Retrospective Studies , Tibial Fractures/classification , Tibial Fractures/surgery , Trauma Severity Indices , Young Adult
18.
J Plast Reconstr Aesthet Surg ; 70(6): 715-722, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28351609

ABSTRACT

Open fractures are severe, complex, limb-threatening and high-energy injuries, often involving lesions of both bone and soft tissues. Traditionally, treatment has been piecemeal by orthopaedic and plastic surgeons. This study aimed to prospectively investigate whether combining orthopaedic and plastic surgery in treating these injuries is more effective than the conventional orthopaedic care. A prospective multi-centre cohort study was conducted. Differences in the type of approach to severe limb trauma allowed a comparison between combined orthoplastic and traditional exclusively orthopaedic treatment. Time for fracture and soft tissue healing and the recovery of limb function were the main outcome measures studied. All patients suffering from a severe open tibial fracture were prospectively included between January 2012 and December 2013 and followed until December 2014. Recruiting units were as follows: (1) an established orthoplastic centre, (2) a unit without experience in the orthoplastic approach and (3) a unit where the orthoplastic approach has been recently introduced in a developing country (Pakistan). A total of 160 patients were included in the study. Of these, 70% were treated with an orthoplastic approach, whereas 30% were treated by an orthopaedic team. All outcome measures were statistically improved by the orthoplastic approach. A coordinated, combined pathway to both the bony and the soft tissue components of open tibial fractures through orthoplastic surgery can be successfully delivered with attention to important timelines to achieve better patient outcomes in different socio-economic settings.


Subject(s)
Fracture Fixation , Fractures, Open/surgery , Plastic Surgery Procedures , Soft Tissue Injuries/surgery , Tibial Fractures/surgery , Adult , Female , Humans , Infections/diagnosis , Infections/drug therapy , Male , Middle Aged , Postoperative Complications , Prospective Studies , Plastic Surgery Procedures/adverse effects , Recovery of Function , Socioeconomic Factors , Treatment Outcome
19.
Foot Ankle Surg ; 23(1): e1-e4, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28159051

ABSTRACT

An irreducible ankle-fracture dislocation characterized by the dislocation of the proximal fragment of the fibula posteriorly to the tibial tubercle is defined as "Bosworth injury". In the present report it is described, for the first time in literature, a complex case where the Bosworth injury was associated to a tibial plafond fracture: the proximal fibular fragment was entrapped between the tibial pilon and the fractured posterior tibial tubercle, which acted as a clamp, thus avoiding ankle reduction. Due to the presence of the tibial fracture, it was not possible to observe the typical radiological signs of Bosworth injury and therefore two unsuccessful reductions were attempted before performing a CT scan that revealed the complexity of the case, that required an immediate ORIF procedure to prevent the onset of complications.


Subject(s)
Ankle Fractures/diagnostic imaging , Intra-Articular Fractures/diagnostic imaging , Joint Dislocations/diagnostic imaging , Ankle Fractures/surgery , Fibula/injuries , Humans , Imaging, Three-Dimensional , Intra-Articular Fractures/surgery , Joint Dislocations/surgery , Male , Middle Aged , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...