Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Musculoskelet Disord ; 25(1): 350, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702748

ABSTRACT

BACKGROUND: Metacarpal shaft fracture is a common type of hand fracture. Numerous studies have explored fixing transverse fractures in the midshaft of the metacarpal bone. However, this section of the metacarpal bone is often susceptible to high-energy injury, resulting in comminuted fracture or bone loss. In such cases, wedge-shaped bone defects can develop in the metacarpal shaft, increasing the difficulty of performing fracture fixation. Notably, the research on this type of fracture fixation is limited. This study compared the abilities of four fixation methods to fix metacarpal shaft fractures with wedge-shaped bone defects. METHODS: In total, 28 artificial metacarpal bones were used. To create wedge-shaped bone defects, an electric saw was used to create metacarpal shaft fractures at the midshaft of each bone. The artificial metacarpal bones were then divided into four groups for fixation. The bones in the first group were fixed with a dorsal locked plate (DP group), those in the second group were fixed with a volar locked plate (VP group), and those in the third group were fixed by combining dorsal and volar locked plates (DP + VP group), and those in the fourth group were fixed with two K-wires (2 K group). Cantilever bending tests were conducted using a material testing machine to measure yielding force and stiffness. The four groups' fixation capabilities were then assessed through analysis of variance and Tukey's test. RESULTS: The DP + VP group (164.1±44.0 N) achieved a significantly higher yielding force relative to the 2 K group (50.7 ± 8.9 N); the DP group (13.6 ± 3.0 N) and VP group (12.3 ± 1.0 N) did not differ significantly in terms of yielding force, with both achieving lower yielding forces relative to the DP + VP group and 2 K group. The DP + VP group (19.8±6.3 N/mm) achieved the highest level of stiffness, and the other three groups did not differ significantly in terms of stiffness (2 K group, 5.4 ± 1.1 N/mm; DP group, 4.0 ± 0.9 N/mm; VP group, 3.9 ± 1.9 N/mm). CONCLUSIONS: The fixation method involving the combined use of dorsal and volar locked plates (DP + VP group) resulted in optimal outcomes with respect to fixing metacarpal shaft fractures with volar wedge bone defects.


Subject(s)
Bone Plates , Bone Wires , Fracture Fixation, Internal , Fractures, Bone , Metacarpal Bones , Metacarpal Bones/injuries , Metacarpal Bones/surgery , Humans , Biomechanical Phenomena , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fractures, Bone/surgery
2.
Quant Imaging Med Surg ; 14(1): 123-135, 2024 Jan 03.
Article in English | MEDLINE | ID: mdl-38223084

ABSTRACT

Background: Lung ultrasound (LUS) and diaphragm ultrasound (DUS) are the appropriate modalities for conservative observation to those patients who are with stable pneumothorax, as well as for the timely detection of life-threatening pneumothorax at any location, due to they are portable, real-time, relatively cost effective, and most important, without radiation exposure. The absence of lung sliding on LUS M-mode images and the abnormality of diaphragmatic excursion (DE) on DUS M-mode images are the most common and novel diagnostic criteria for pneumothorax, respectively. However, visual inspection of M-mode images remains subjective and quantitative analysis of LUS and DUS M-mode images are required. Methods: Shannon entropy of LUS M-mode image (ShanEnLM) and DE based on the automated measurement (DEAM) are adapted to the objective pneumothorax diagnoses and the severity quantifications in this study. Mild, moderate, and severe pneumothoraces were induced in 24 male New Zealand rabbits through insufflation of room air (5, 10 and 15, and 25 and 40 mL/kg, respectively) into their pleural cavities. In vivo intercostal LUS and subcostal DUS M-mode images were acquired using a point-of-care system for estimating ShanEnLM and DEAM. Results: ShanEnLM and DEAM as functions of air insufflation volumes exhibited U-shaped curves and were exponentially decreasing, respectively. Either ShanEnLM or DEAM had areas under the receiver operating characteristic curves [95% confidence interval (CI)] of 1.0000 (95% CI: 1.0000-1.0000), 0.9833 (95% CI: 0.9214-1.0000), and 0.9407 (95% CI: 0.8511-1.0000) for differentiating between normal and mild pneumothorax, mild and moderate pneumothoraces, and moderate and severe pneumothoraces, respectively. Conclusions: Our findings imply that the combination of ShanEnLM and DEAM give the promising potential for pneumothorax quantitative diagnosis.

SELECTION OF CITATIONS
SEARCH DETAIL