1.
Magn Reson Med ; 89(1): 77-94, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36128895

ABSTRACT

PURPOSE: To evaluate the benefits and challenges of dynamic parallel transmit (pTx) pulses for fat saturation (FS) and water-excitation (WE), in the context of CEST MRI. METHODS: "Universal" kT -points (for FS) and spiral non-selective (for WE) trajectories were optimized offline for flip angle (FA) homogeneity. Routines to optimize the pulse shape online, based on the subject's fields maps, were implemented (target FA of 110°/0° for FS, 0°/5° for WE at fat/water frequencies). The pulses were inserted in a CEST sequence with a pTx readout. The different fat suppression schemes and their effects on CEST contrasts were compared in 12 volunteers at 7T. RESULTS: With a 25%-shorter pulse duration, pTx FS largely improved the FA homogeneity (root-mean-square-error (RMSE) = 12.3° vs. 53.4° with circularly-polarized mode, at the fat frequency). However, the spectral selectivity was degraded mainly in the cerebellum and close to the sinuses (RMSE = 5.8° vs. 0.2° at the water frequency). Similarly, pTx WE showed a trade-off between FA homogeneity and spectral selectivity compared to pTx non-selective pulses (RMSE = 0.9° and 1.1° at the fat and water frequencies, vs. 4.6° and 0.5°). In the brain, CEST metrics were reduced by up to 31.9% at -3.3 ppm with pTx FS, suggesting a mitigated lipid-induced bias. CONCLUSION: This clinically compatible implementation of dynamic pTx pulses improved the fat suppression homogeneity at 7T taking into account the subject-specific B0 heterogeneities online. This study highlights the lipid-induced biases on the CEST z-spectrum. The results are promising for body applications where B0 heterogeneities and fat are more substantial.


Subject(s)
Magnetic Resonance Imaging , Water , Humans , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Contrast Media , Lipids , Algorithms
2.
Magn Reson Med ; 86(1): 346-362, 2021 07.
Article in English | MEDLINE | ID: mdl-33634505

ABSTRACT

PURPOSE: To enable whole-brain quantitative CEST MRI at ultra-high magnetic field strengths (B0 ≥ 7T) within short acquisition times. METHODS: Multiple interleaved mode saturation (MIMOSA) was combined with fast online-customized (FOCUS) parallel transmission (pTx) excitation pulses and B1+ correction to achieve homogenous whole-brain coverage. Examinations of 13 volunteers were performed on a 7T MRI system with 3 different types of pulse sequences: (1) saturation in circular polarized (CP) mode and CP mode readout, (2) MIMOSA and CP readout, and (3) MIMOSA and FOCUS readout. For comparison, the inverse magnetic transfer ratio metric for relayed nuclear Overhauser effect and amide proton transfer were calculated. To investigate the number of required acquisitions for a good B1+ correction, 4 volunteers were measured with 6 different B1 amplitudes. Finally, time point repeatability was investigated for 6 volunteers. RESULTS: MIMOSA FOCUS sequence using B1+ correction, with both single and multiple points, reduced inhomogeneity of the CEST contrasts around the occipital lobe and cerebellum. Results indicate that the most stable inter-subject coefficient of variation was achieved using the MIMOSA FOCUS sequence. Time point repeatability of MIMOSA FOCUS with single-point B1+ correction showed a maximum coefficient of variation below 8% for 3 measurements in a single volunteer. CONCLUSION: A combination of MIMOSA FOCUS with a single-point B1+ correction can be used to achieve quantitative CEST measurements at ultra-high magnetic field strengths. Compared to previous B1+ correction methods, acquisition time can be reduced as additional scans required for B1+ correction can be omitted.


Subject(s)
Algorithms , Magnetic Resonance Imaging , Brain/diagnostic imaging , Contrast Media , Humans , Protons
3.
Magn Reson Med ; 82(2): 693-705, 2019 08.
Article in English | MEDLINE | ID: mdl-31002432

ABSTRACT

PURPOSE: To mitigate B1+ inhomogeneity in quantitative CEST MRI at ultra-high magnetic field strengths (B0 ≥ 7 Tesla) using a parallel transmit system. METHODS: Multiple interleaved mode saturation employs interleaving of 2 complementary phase sets during the saturation pulse train. Phase differences of 45° (first mode) and 90° (second mode) between 2 adjacent transmitter coil channels are used. The influence of the new saturation scheme on the CEST contrast was analyzed using Bloch-McConnell simulations. The presented method was verified in phantom and in vivo measurements of the healthy human brain. The relayed nuclear Overhauser effect was evaluated, and the inverse magnetic transfer ratio metric was calculated. Results were compared to a published B1+ correction method. All measurements were conducted on a whole-body 7 Tesla MRI system using an 8 transmitter and 32 receiver channel head coil. RESULTS: Simulations showed that the inverse magnetic transfer ratio metric contrast of relayed nuclear Overhauser effect shows a smaller dependency on the relative amplitudes of the 2 different modes than the contrasts of Cr and amide proton transfer. Measurements of an egg white phantom showed markedly improved homogeneity compared to the uncorrected inverse magnetic transfer ratio metric (relayed nuclear Overhauser effect) images and slightly improved results compared to B1+ corrected images. In vivo multiple interleaved mode saturation images showed similar contrast compared to B1+ corrected images. CONCLUSION: Multiple interleaved mode saturation can be used as a simple method to mitigate B1+ inhomogeneity effects in CEST MRI at ultra-high magnetic field strengths. Compared to previous B1+ correction methods, acquisition time can be reduced because an additional scan, usually required for B1+ correction, can be omitted.


Subject(s)
Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Adult , Amides , Brain/diagnostic imaging , Computer Simulation , Female , Humans , Male , Phantoms, Imaging , Protons , Young Adult