Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Phys Rev Lett ; 124(18): 185003, 2020 May 08.
Article in English | MEDLINE | ID: mdl-32441981

ABSTRACT

Rayleigh-Taylor instability growth is shown to be hydrodynamically scale invariant in convergent cylindrical implosions for targets that varied in radial dimension and implosion timescale by a factor of 3. The targets were driven directly by laser irradiation providing a short impulse, and instability growth at an embedded aluminum interface occurs as it converges radially inward by a factor of 2.25 and decelerates on a central foam core. Late-time growth factors of 14 are observed for a single-mode m=20 azimuthal perturbation at both scales, despite the differences in laser drive conditions between the experimental facilities, consistent with predictions from radiation-hydrodynamics simulations. This platform enables detailed investigations into the limits of hydrodynamic scaling in high-energy-density systems.

2.
Rev Sci Instrum ; 89(10): 10H117, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399739

ABSTRACT

Synthetic diagnostics are aimed at simulating the response of diagnostic systems under actual experimental scenarios and are the key to drawing quantitative inferences from experimental data. The synthetic Electron Cyclotron Emission Imaging (ECEI) diagnostic is suitable for evaluation of the improvement arising from the application of Field Curvature Adjustment (FCA) lenses in the design of the upgraded Experimental Advanced Superconducting Tokamak (EAST) tokamak ECEI system. In previous ECEI systems, a curved image plane is inevitable in optics systems comprising only convex lenses, which leads to significant crosstalk between vertically adjacent channels and strongly limits the vertical channel resolution of the imaging system. The synthetic ECEI diagnostic results show that, with FCA lenses applied, the upgraded ECEI system has significant advantages to focus on high poloidal wavenumber structures with the aberrations from the spherical surfaces corrected and the various artifacts related to the field curvature suppressed. Also, the synthetic ECEI diagnostic is used for some quantitative calculations to partially decouple the effect of density fluctuations and temperature fluctuations for a given plasma.

3.
Rev Sci Instrum ; 89(10): 10H108, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399905

ABSTRACT

Recent advances in radio-frequency system-on-chip technology have provided mm-wave fusion plasma diagnostics with the capability to overcome major challenges such as space inefficiency, inflexible installation, sensitivity, susceptibility to EMI, and prohibitively high cost of conventional discrete component assemblies as higher imaging resolution and data accuracy are achieved by increasing the number of channels. Nowadays, shrinking transistor gate lengths on fabrication techniques have enabled hundreds of GHz operation, which is suitable for millimeter-wave diagnostics on current and future tokamaks. The Davis Millimeter Wave Research Center (DMRC) has successfully developed V-band (55-75 GHz) transmitter and receiver chips for Microwave Imaging Reflectometer (MIR) instruments. The transmitter can illuminate 8 different frequencies simultaneously within 55-75 GHz. Moreover, the receiver has the capability to amplify the reflected signal (>30 dB) while offering 10-30× reduction in noise temperature compared to current MIR instruments. Plasma diagnostics requires ultra-wideband (more than 20 GHz) operation which is approximately nine times wider bandwidth than the recent commercial impetus for communication systems. Current efforts are underway for gallium-arsenide monolithic microwave integrated circuit receiver chips at W-band (75-110 GHz) and F-band (90-140 GHz) permitting measurements at higher toroidal magnetic fields.

4.
Rev Sci Instrum ; 87(11): 11D901, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910310

ABSTRACT

Millimeter-wave imaging diagnostics, with large poloidal span and wide radial range, have been developed on the EAST tokamak for visualization of 2D electron temperature and density fluctuations. A 384 channel (24 poloidal × 16 radial) Electron Cyclotron Emission Imaging (ECEI) system in F-band (90-140 GHz) was installed on the EAST tokamak in 2012 to provide 2D electron temperature fluctuation images with high spatial and temporal resolution. A co-located Microwave Imaging Reflectometry (MIR) will be installed for imaging of density fluctuations by December 2016. This "4th generation" MIR system has eight independent frequency illumination beams in W-band (75-110 GHz) driven by fast tuning synthesizers and active multipliers. Both of these advanced millimeter-wave imaging diagnostic systems have applied the latest techniques. A novel design philosophy "general optics structure" has been employed for the design of the ECEI and MIR receiver optics with large aperture. The extended radial and poloidal coverage of ECEI on EAST is made possible by innovations in the design of front-end optics. The front-end optical structures of the two imaging diagnostics, ECEI and MIR, have been integrated into a compact system, including the ECEI receiver and MIR transmitter and receiver. Two imaging systems share the same mid-plane port for simultaneous, co-located 2D fluctuation measurements of electron density and temperature. An intelligent remote-control is utilized in the MIR electronics systems to maintain focusing at the desired radial region even with density variations by remotely tuning the probe frequencies in about 200 µs. A similar intelligent technique has also been applied on the ECEI IF system, with remote configuration of the attenuations for each channel.

5.
Rev Sci Instrum ; 87(11): 11D303, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910444

ABSTRACT

A Synthetic Diagnostics Platform (SDP) for fusion plasmas has been developed which provides state of the art synthetic reflectometry, beam emission spectroscopy, and Electron Cyclotron Emission (ECE) diagnostics. Interfaces to the plasma simulation codes GTC, XGC-1, GTS, and M3D-C1 are provided, enabling detailed validation of these codes. In this paper, we give an overview of SDP's capabilities, and introduce the synthetic diagnostic modules. A recently developed synthetic ECE Imaging module which self-consistently includes refraction, diffraction, emission, and absorption effects is discussed in detail. Its capabilities are demonstrated on two model plasmas. The importance of synthetic diagnostics in validation is shown by applying the SDP to M3D-C1 output and comparing it with measurements from an edge harmonic oscillation mode on DIII-D.

6.
Phys Rev Lett ; 114(10): 105001, 2015 Mar 13.
Article in English | MEDLINE | ID: mdl-25815937

ABSTRACT

Density pumpout and edge-localized mode (ELM) suppression by applied n=2 magnetic fields in low-collisionality DIII-D plasmas are shown to be correlated with the magnitude of the plasma response driven on the high-field side (HFS) of the magnetic axis but not the low-field side (LFS) midplane. These distinct responses are a direct measurement of a multimodal magnetic plasma response, with each structure preferentially excited by a different n=2 applied spectrum and preferentially detected on the LFS or HFS. Ideal and resistive magneto-hydrodynamic (MHD) calculations find that the LFS measurement is primarily sensitive to the excitation of stable kink modes, while the HFS measurement is primarily sensitive to resonant currents (whether fully shielding or partially penetrated). The resonant currents are themselves strongly modified by kink excitation, with the optimal applied field pitch for pumpout and ELM suppression significantly differing from equilibrium field alignment.

7.
Rev Sci Instrum ; 85(11): 11D702, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430212

ABSTRACT

The two-dimensional mm-wave imaging reflectometer (MIR) on DIII-D is a multi-faceted device for diagnosing electron density fluctuations in fusion plasmas. Its multi-channel, multi-frequency capabilities and high sensitivity permit visualization and quantitative diagnosis of density perturbations, including correlation length, wavenumber, mode propagation velocity, and dispersion. The two-dimensional capabilities of MIR are made possible with 12 vertically separated sightlines and four-frequency operation (corresponding to four radial channels). The 48-channel DIII-D MIR system has a tunable source that can be stepped in 500 µs increments over a range of 56 to 74 GHz. An innovative optical design keeps both on-axis and off-axis channels focused at the cutoff surface, permitting imaging over an extended poloidal region. The integrity of the MIR optical design is confirmed by comparing Gaussian beam calculations to laboratory measurements of the transmitter beam pattern and receiver antenna patterns. Measurements are presented during the density ramp of a plasma discharge to demonstrate unfocused and focused MIR signals.

8.
Rev Sci Instrum ; 85(11): 11D833, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430246

ABSTRACT

In a major upgrade, the (2D) electron cyclotron emission imaging diagnostic (ECEI) at ASDEX Upgrade has been equipped with a second detector array, observing a different toroidal position in the plasma, to enable quasi-3D measurements of the electron temperature. The new system will measure a total of 288 channels, in two 2D arrays, toroidally separated by 40 cm. The two detector arrays observe the plasma through the same vacuum window, both under a slight toroidal angle. The majority of the field lines are observed by both arrays simultaneously, thereby enabling a direct measurement of the 3D properties of plasma instabilities like edge localized mode filaments.

9.
Rev Sci Instrum ; 85(11): 11D834, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430247

ABSTRACT

A 2D microwave imaging reflectometer system has been developed to visualize electron density fluctuations on the DIII-D tokamak. Simultaneously illuminated at four probe frequencies, large aperture optics image reflections from four density-dependent cutoff surfaces in the plasma over an extended region of the DIII-D plasma. Localized density fluctuations in the vicinity of the plasma cutoff surfaces modulate the plasma reflections, yielding a 2D image of electron density fluctuations. Details are presented of the receiver down conversion electronics that generate the in-phase (I) and quadrature (Q) reflectometer signals from which 2D density fluctuation data are obtained. Also presented are details on the control system and backplane used to manage the electronics as well as an introduction to the computer based control program.

10.
Rev Sci Instrum ; 85(11): 11D854, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430267

ABSTRACT

Significant progress has been made in the imaging and visualization of magnetohydrodynamic and microturbulence phenomena in magnetic fusion plasmas. Of particular importance has been microwave electron cyclotron emission imaging (ECEI) for imaging Te fluctuations. Key to the success of ECEI is a large Gaussian optics system constituting a major portion of the focusing of the microwave radiation from the plasma to the detector array. Both the spatial resolution and observation range are dependent upon the imaging optics system performance. In particular, it is critical that the field curvature on the image plane is reduced to decrease crosstalk between vertical channels. The receiver optics systems for two ECEI on the J-TEXT device have been designed to ameliorate these problems and provide good performance with additional field curvature adjustment lenses with a meniscus shape to correct the aberrations from several spherical surfaces.

11.
Rev Sci Instrum ; 85(11): 11D863, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430276

ABSTRACT

A synthetic microwave imaging reflectometer (MIR) diagnostic employing the full-wave reflectometer code (FWR2D) has been developed and is currently being used to guide the design of real systems, such as the one recently installed on DIII-D. The FWR2D code utilizes real plasma profiles as input, and it is combined with optical simulation tools for synthetic diagnostic signal generation. A detailed discussion of FWR2D and the process to generate the synthetic signal are presented in this paper. The synthetic signal is also compared to a prescribed density fluctuation spectrum to quantify the imaging quality. An example is presented with H-mode-like plasma profiles derived from a DIII-D discharge, where the MIR focal is located in the pedestal region. It is shown that MIR is suitable for diagnosing fluctuations with poloidal wavenumber up to 2.0 cm(-1) and fluctuation amplitudes less than 5%.

12.
Rev Sci Instrum ; 83(10): 10E329, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126987

ABSTRACT

A synthetic diagnostic has been developed that reproduces the highly structured electron cyclotron emission (ECE) spectrum radiated from the edge region of H-mode discharges. The modeled dependence on local perturbations of the equilibrium plasma pressure allows for interpretation of ECE data for diagnosis of local quantities. Forward modeling of the diagnostic response in this region allows for improved mapping of the observed fluctuations to flux surfaces within the plasma, allowing for the poloidal mode number of coherent structures to be resolved. In addition, other spectral features that are dependent on both T(e) and n(e) contain information about pedestal structure and the electron energy distribution of localized phenomena, such as edge filaments arising during edge-localized mode (ELM) activity.

13.
Rev Sci Instrum ; 83(10): 10E338, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126996

ABSTRACT

Microwave imaging reflectometry provides broad poloidal coverage as a density fluctuation measurement tool. 2D imaging systems are evaluated for DIII-D relevant conditions using a full-wave reflectometer code, FWR2D. Reasonable correlation of the synthetic diagnostic signal with density fluctuations at the plasma cutoff surface for a wide range of fluctuation parameters is evaluated and achieved for coherent oscillations; also the frequency spectra are compared for relevant fluctuations. The consequences of non-idealities inherent to imaging fluctuations away from the plasma midplane, where receiving antennas view the plasma cutoff at oblique angles, are evaluated for the optimization of these systems.

14.
Phys Rev Lett ; 106(7): 075003, 2011 Feb 18.
Article in English | MEDLINE | ID: mdl-21405522

ABSTRACT

Two-dimensional images of electron temperature perturbations are obtained with electron cyclotron emission imaging (ECEI) on the DIII-D tokamak and compared to Alfvén eigenmode structures obtained by numerical modeling using both ideal MHD and hybrid MHD-gyrofluid codes. While many features of the observations are found to be in excellent agreement with simulations using an ideal MHD code (NOVA), other characteristics distinctly reveal the influence of fast ions on the mode structures. These features are found to be well described by the nonperturbative hybrid MHD-gyrofluid model TAEFL.

15.
Arterioscler Thromb ; 14(2): 230-4, 1994 Feb.
Article in English | MEDLINE | ID: mdl-8305413

ABSTRACT

Structural analysis of atherosclerotic coronary arteries has suggested that stress concentrations are associated with plaque rupture and that these stress concentrations are critically dependent on the geometry and mechanical properties of the fibrous cap and lipid pool. Recent clinical trials of lipid-lowering therapy have shown a significant reduction in cardiac events associated with plaque rupture perhaps because of the changing composition of subintimal lipid pools. To test the hypothesis that changes in lipid composition can change the mechanical properties of lipid pools, we measured the dynamic shear moduli of combinations of cholesterol monohydrate crystals, phospholipids, and triglycerides similar to those found in atherosclerotic lesions. Increasing the cholesterol monohydrate concentration from 0% to 50% increased the real component of the dynamic shear modulus (storage modulus or stiffness) by 4.5 times at a frequency of 1 Hz (P < .001). All specimens demonstrated an increase in stiffness with increasing frequencies of stress ranging from 0.1 to 3 Hz. We conclude that the stiffness of model atherosclerotic plaque lipid pools is related to the concentration of cholesterol monohydrate crystals. Because the relative concentration of cholesterol monohydrate increases during early regression of experimental atherosclerosis, the resultant stiffening of the lipid pool may reduce stresses in plaque caps. However, the magnitude of the contribution of changing lipid stiffness to the reduction of cardiac events seen in clinical studies is unclear.


Subject(s)
Arteriosclerosis/metabolism , Coronary Vessels/metabolism , Lipid Metabolism , Models, Cardiovascular , Arteriosclerosis/pathology , Arteriosclerosis/physiopathology , Cholesterol/metabolism , Coronary Vessels/pathology , Coronary Vessels/physiopathology , Elasticity , Electric Stimulation , Humans , Osmolar Concentration , Rotation , Stress, Mechanical
SELECTION OF CITATIONS