J Electrocardiol ; 85: 37-38, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38830293

ABSTRACT

We present the case of a 60-year-old male patient who was admitted to our hospital after experiencing a syncopal episode. First ECGs showed sinus rhythm with polymorphic premature ventricular complexes and later ventricular tachycardia with a left bundle branch block morphology were recorded. Imaging with TEE and MRI revealed a space-occupying lesion in the left ventricle, which was ultimately identified as a rare cardiac metastasis of renal cell carcinoma. Treatment was initiated with monoclonal antibodies resulting in lesion regression. This case highlights the importance of comprehensive diagnostic in patients with history of malignancy.

2.
Article in English | MEDLINE | ID: mdl-38750671

ABSTRACT

BACKGROUND: Management of atrial fibrillation (AF) in very severe obese patients is challenging. Cryoballoon ablation (CBA) represents an effective rhythm control strategy. However, data in this patient group were limited. METHODS: Highly symptomatic AF patients with body mass index (BMI) ≥ 40 kg/m2 who had failed antiarrhythmic drug therapy and electrocardioversion and failure to achieve targeted body-weight-reduction underwent CBA. RESULTS: Data of 72 very severe obese AF patients (Group A) and 129 AF patients with normal BMI (Group B, BMI < 25 kg/m2) were consecutively collected. Group A had significantly younger age (60.6 ± 10.4 vs. 69.2 ± 11.2 years), higher BMI (44.3 ± 4.3 vs. 22.5 ± 1.6 kg/m2). Procedural pulmonary vein isolation (PVI) was successful in all patients (2 touch-up ablation in Group A). Compared to Group B, Group A had similar procedural (61.3 ± 22.6 vs. 57.5 ± 19 min), similar fluoroscopy time (10.1 ± 5.5 vs. 9.2 ± 4.8 min) but significantly higher radiation dose (2852 ± 2095 vs. 884 ± 732 µGym2). We observed similar rates of real-time-isolation (78.6% vs. 78.5%), single-shot-isolation (86.5% vs. 88.8%), but significantly longer time-to-sustained-isolation (53.5 ± 33 vs. 43.2 ± 25 s). There was significantly higher rate of puncture-site-complication (6.9% vs. 1.6%) in Group A. One-year clinical success in paroxysmal AF was (Group A: 69.4% vs. Group B: 80.2%; p < .001), in persistent AF was (Group A: 58.1% vs. Group B: 62.8%; p = .889). In Re-Do procedures Group A had a numerically lower PVI durability (75.0% vs. 83.6%, p = .089). CONCLUSION: For very severe obese AF patients, CBA appears feasible, leads to relatively good clinical outcome.

3.
Article in English | MEDLINE | ID: mdl-38652213

ABSTRACT

Catheter ablation of atrial fibrillation using non-thermal electroporation represents a promising ablation modality due to its believed superior safety profile. Still, if electroporation is delivered in proximity to a coronary artery, vasospasms can occur. We report the first case of severe right coronary artery vasospasm resulting in ST-segment elevation and AV block despite a remote distance from the ablation site to the right coronary artery, indicating a different mechanism. In this case, electroporation most likely triggered a previously unknown Prinzmetal vasospastic angina in the patient, resulting in the coronary vasospasm. Thus, meticulous monitoring of ST-segment changes following PFA delivery even from regions remote to coronary arteries is required.

4.
Article in English | MEDLINE | ID: mdl-38573537

ABSTRACT

BACKGROUND: Vascular complications are a common occurrence during atrial fibrillation ablation. Observational studies indicate that the utilization of ultrasound (US)-guided puncture may decrease the incidence of vascular complications; however, its routine use is not established in many centres. METHODS: Patients undergoing catheter ablation for atrial fibrillation were included sequentially. All patients receiving US-guided punctures were prospectively enrolled (US group), while patients who underwent the procedure with standard puncture technique served as control group (No-US group). Periprocedural vascular complications requiring intervention within 30 days of the procedure were defined as the primary endpoint. RESULTS: A total of 599 patients (average age: 69 ± 11 years, 62.9% male) were analysed. The incidence of vascular complications was lower with the US-guided puncture than with the anatomic landmark-guided puncture (14/299 [4.7%] vs. 27/300 [9%], p = 0.036). The US-guided vascular access significantly reduced the rate of false aneurysms (3/299 [1%] vs. 12/300 [4%], p = 0.019). In addition, the occurrence of arteriovenous fistula (2/299 [0.7%] vs. 4/300 [1.3%], p = 0.686) and haematoma requiring treatment (9/299 [3%] vs. 11/300 [3.7%], p = 0.655) were also lower in the US group. US-guided puncture did not prolong the procedure time (mean procedure time: 57.48 ± 24.47 min vs. 56.09 ± 23.36 min, p = 0.478). Multivariate regression analysis identified female gender (OR 2.079, CI 95% 1.096-3.945, p = 0.025) and conventional vascular access (OR 2.079, CI 95% 1.025-3.908, p = 0.042) as predictors of vascular complications. CONCLUSIONS: The implementation of US-guided vascular access for left atrial catheter ablation resulted in a significant decrease of the overall vascular complication rate.

5.
J Cardiovasc Electrophysiol ; 34(12): 2425-2433, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37767744

ABSTRACT

INTRODUCTION: Pulsed field ablation (PFA) is a new ablation technology for atrial fibrillation (AF). Data regarding early recurrences of atrial tachyarrhythmia (ERAT) after PFA-pulmonary vein isolation (PVI) are sparse. METHODS: Consecutive patients with symptomatic AF were enrolled to undergo PFA-PVI. A dedicated catheter delivering bipolar energy (1.9-2.0 kV) was used. Late recurrence (LR) was defined as documented AF/atrial tachycardia (AT) lasting more than 30 s after a 90-day blanking period. RESULTS: Two hundred and thirty-one patients (42% female, age 69 ± 12, 55% paroxysmal AF [PAF]) were included in this analysis. Median follow-up time was 367 days (interquartile range: 253-400). Forty-six patients (21%) experienced ERAT after a median of 23 days (46% in PAF and 54% in persistent AF [persAF]). Kaplan-Meier estimated freedom of AF/AT was 74.2% at 1 year, 81.8% for PAF, and 64.8% for persAF (p = .0079). Of patients experiencing ERAT, an LR was observed in 54%. There was no significant difference of LR between those who presented with very early ERAT (0-45 days) and those with ERAT (46-90 days) (p = .57). In multivariate analysis, ERAT (hazard ratio [HR]: 3.370; 95% confidence interval [95% CI]: 1.851-6.136; p < .001) and female sex (HR: 2.048; 95% CI: 1.114-3.768; p = .021) were the only independent predictors for LR. CONCLUSIONS: ERAT could be recorded in 21% of patients after PFA-PVI and was an independent predictor for LR. We found no difference in the rate of LRs among patients experiencing ERAT before or after 45 days.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Tachycardia, Supraventricular , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Treatment Outcome , Time Factors , Recurrence , Heart Atria , Catheter Ablation/adverse effects , Pulmonary Veins/surgery
6.
Article in English | MEDLINE | ID: mdl-37427302

ABSTRACT

Catheter ablation is a widely used, effective and safe treatment for AF. Pulsed field ablation (PFA), as a novel energy source for cardiac ablation, has been shown to be tissue selective and is expected to decrease damage to non-cardiac tissue while providing high efficacy in pulmonary vein isolation. The FARAPULSE ablation system (Boston Scientific) follows the idea of single-shot ablation and is the first device approved for clinical use in Europe. Since its approval, multiple high-volume centres have performed increasing numbers of PFA procedures in patients with AF and have published their experiences. This review summarises the current clinical experience regarding the use of PFA for AF using the FARAPULSE system. It provides an overview of its efficacy and safety.

7.
JACC Clin Electrophysiol ; 9(9): 1864-1875, 2023 09.
Article in English | MEDLINE | ID: mdl-37480870

ABSTRACT

BACKGROUND: Although the autonomic reaction such as bradycardia is observed frequently during pulsed-field ablation (PFA)-guided pulmonary vein isolation (PVI), its mechanism and effect on the adjacent intrinsic cardiac autonomic nervous system (ICANS) are unclear. OBJECTIVES: This study aimed to reveal the clinical impact of PFA on ICANS by investigating the serum S100 increase (ΔS100), a well-known denervation relevant biomarker. METHODS: Pre- and postprocedural serum S100 analyses were systematically conducted in patients undergoing PVI using either the pentaspline PFA or cryoballoon ablation (CBA) system. ΔS100 release kinetics were compared between both technologies. Cerebral magnetic resonance imaging was conducted to eliminate the effect of central nervous system release. RESULTS: A total of 97 patients (PFA: n = 54 and CBA: n = 43) were enrolled. Overall S100 increased in both groups with a lower amount in PFA (0.035 µg/L; IQR: 0.02-0.063 µg/L) compared with CBA (0.12 µg/L; IQR: 0.09-0.17 µg/L; P < 0.0001). In cerebral magnetic resonance imaging, silent emboli were detected in 10 patients (18.5%) in PFA and 7 patients (16.3%) in CBA (P = 0.773). Even after excluding patients with cerebral emboli, ΔS100 was lower in PFA. During PFA PVI, 30 patients (56%) demonstrated transient bradycardia in 70 of 210 PVs (35%). ΔS100 was similar between patients with or without transient bradycardia. CONCLUSIONS: We report a significantly lower S100 release following PFA PVI vs CBA PVI even if silent cerebral emboli were excluded. Notably, vagal response during PFA was not associated with S100 release. These observations are in line with lower nervous tissue destruction of PFA compared with CBA.


Subject(s)
Intracranial Embolism , Pulmonary Veins , Humans , Bradycardia , Pulmonary Veins/surgery , Heart , Autonomic Nervous System
8.
JACC Clin Electrophysiol ; 9(9): 1990-1994, 2023 09.
Article in English | MEDLINE | ID: mdl-37227358

ABSTRACT

Three cases of ventricular tachycardia ablation with pulsed-field ablation technology performed at 2 separate centers are reported, highlighting the advantages and disadvantages of this tool inside the ventricle: its dependence on proximity rather than contact makes it useful in sites with poor stability, while the speed of application and large scope of action provided by commercially available catheters could help with ablating large diseased areas of endocardium in a fast and hemodynamically well-tolerated fashion. However, lesion depth could be insufficient for guaranteeing efficacy in preventing ventricular tachycardias originating at an epicardial site, even in the right ventricle.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Heart Ventricles/surgery , Electrocardiography , Tachycardia, Ventricular/surgery , Endocardium
9.
Circ Arrhythm Electrophysiol ; 16(7): 389-398, 2023 07.
Article in English | MEDLINE | ID: mdl-37254781

ABSTRACT

BACKGROUND: The cryoballoon (CB) represents the gold standard single-shot device for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Single-shot pulsed field PVI ablation (nonthermal, cardiac tissue selective) has recently entered the arena. We sought to compare procedural data and long-term outcome of both techniques. METHODS: Consecutive AF patients who underwent pulsed field ablation (PFA) and CB-based PVI were enrolled. CB PVI was performed using the second-generation 28-mm CB; PFA was performed using a 31/35-mm pentaspline catheter. Success was defined as freedom from atrial tachyarrhythmia after a 3-month blanking period. RESULTS: Four hundred patients were included (56.5% men; 60.8% paroxysmal AF; age 70 [interquartile range, 59-77] years), 200 in each group (CB and PFA), and baseline characteristics did not differ. Acute PVI was achieved in 100% of PFA and in 98% (196/200) of CB patients (P=0.123; 4 touch-up ablations). Median procedure time was significantly shorter in PFA (34.5 [29-40] minutes) versus CB (50 [45-60] minutes; P<0.001), fluoroscopy time was similar. Overall procedural complications were 6.5% in CB and 3.0% in PFA (P=0.1), driven by a higher rate of phrenic nerve palsies using CB. The 1-year success rates in paroxysmal AF (CB, 83.1%; PFA, 80.3%; P=0.724) and persistent AF (CB, 71%; PFA, 66.8%; P=0.629) were similar for both techniques. CONCLUSIONS: PFA compared with CB PVI shows a similar procedural efficacy but is associated with shorter procedure time and no phrenic nerve palsies. Importantly, 12-month clinical success rates are favorable but not different between both groups.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Male , Humans , Aged , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Follow-Up Studies , Treatment Outcome , Pulmonary Veins/surgery , Paralysis/surgery , Catheter Ablation/methods , Recurrence
10.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37116126

ABSTRACT

AIMS: A novel irrigated radiofrequency (RF) balloon (RFB) for pulmonary vein (PV) isolation (PVI) was released in selected centres. We pooled the procedural data on efficacy and safety of RFB-PVI from two high volume German centres. METHODS AND RESULTS: Consecutive patients with RFB procedures were enrolled. A 3D electroanatomical left atrial map guided the RFB navigation. Every RF delivery lasted 60 s, and duration was automatically reduced to 20 s for electrodes facing the posterior wall. Procedural data and post-procedural endoscopy data (<48 h) were analysed. Data from 140 patients were collected (57% male, 67 ± 11 years, 57% paroxysmal atrial fibrillation). There were 547 PVs identified, and 99.1% could be isolated using solely the RFB. Single-shot PVI was recorded in 330/547 (60%) PVs. Median time to isolation during the first application was 10 s (IQR 8-13). A total of 2.1 ± 1.8 applications per PV were delivered, with the left superior PV requiring more application compared to other PVs. Median procedure and fluoroscopy time were 77 min (61-99) and 13 min (10-17), respectively. Major safety events were recorded only in the first 25 cases at each centre and included 1/140(0.7%) cardiac tamponade, 1/140(0.7%) phrenic nerve palsy, and 2/140 strokes (1.4%). An oesophageal temperature rise was recorded in 81/547 (15%) PVs, and endoscopy detected oesophageal lesions in 7/85 (8%) patients undergoing endoscopy. CONCLUSION: The RFB showed a high efficacy allowing for fast PVI procedures, and 60% of PVs could be isolated at the first application. Most safety events were recorded during the learning phase. An oesophageal temperature monitoring is suggested: oesophageal lesions were detected in 8% of patients.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Male , Female , Treatment Outcome , Catheter Ablation/adverse effects , Catheter Ablation/methods , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Heart Atria , Pulmonary Veins/surgery
12.
Pacing Clin Electrophysiol ; 46(5): 414-418, 2023 05.
Article in English | MEDLINE | ID: mdl-36424836

ABSTRACT

Pulsed field ablation (PFA) using high-voltage electrical energy is a novel and powerful ablation modality. However, PFA as a first-line rhythm control in atrial fibrillation (AF) has been rarely described; whether PFA interacts with the pacemaker (PM) has been seldom reported. We reported PFA of AF in a patient with PM who needed effective rhythm control. Pulmonary vein isolation (PVI) was successfully performed without complication, and the procedure was extremely fast (skin-to-skin 25 min.) with short fluoroscopic time (3.9 min). PFA had no influence on the PM function. Six months' follow-up showed good clinical outcome and significantly decreased AF burden.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Treatment Outcome , Catheter Ablation/methods , Pulmonary Veins/surgery , Recurrence
13.
Europace ; 25(2): 433-440, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36427201

ABSTRACT

AIMS: Pulsed-field ablation (PFA) can offer a novel perspective for atrial fibrillation (AF) ablation. We aimed to characterize the incidence of pulmonary vein (PV) reconnection, types of recurrent atrial tachyarrhythmia (ATa) and lesion quality after PFA-guided PV isolation (PVI). METHODS AND RESULTS: Patients undergoing second ablation for recurrent ATa following the initial PVI using the pentaspline PFA catheter were investigated. The rate of PV reconnection, the features of recurrent ATa, and the amount of isolated posterior wall (PW) surface area (ISAPW%) (ratio of the isolated- to total surface area on PW) were analyzed. RESULTS: Among 360 patients treated with PFA, 25 patients (paroxysmal AF, n = 19) with 99 PVs underwent a second procedure 6.1 ± 4.0 months after the initial procedure. The rate of PV reconnection was 9.1% (9 PVs). Patients presented with atrial tachycardia (AT) (n = 16), AF (n = 8) and typical atrial flutter (n = 1). The mechanism of all but one AT was macro-reentry. The critical isthmus was found to be linked to the initial lesion set at the left atrial (LA) PW in eight patients and linked to pre-existing substrate at the LA anterior wall in four patients. One AT had a focal origin at the septum. In three patients, AT were unmappable. Mean ISAPW% was 72.7 ± 19.0%. CONCLUSION: We revealed a remarkable low reconnection rate with a large antral lesion at the PW after pentaspline PFA catheter-guided PVI. However, macro-reentrant AT with a critical isthmus at the LAPW linked to the PVI lesion set was commonly observed.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Pulmonary Veins , Tachycardia, Supraventricular , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Heart Atria , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence , Treatment Outcome
15.
Herzschrittmacherther Elektrophysiol ; 33(4): 367-372, 2022 Dec.
Article in German | MEDLINE | ID: mdl-36131155

ABSTRACT

Metabolic syndrome is defined by the simultaneous occurrence of the cardiovascular risk factors obesity, hypertension, diabetes and dyslipidemia. Overweight, in particular, is continuously increasing in many countries. In this respect, metabolic syndrome is a strong risk factor for atrial fibrillation. Only few data are available on the influence of obesity on antiarrhythmic drugs. Sodium channel blockers, in particular, appear to show a reduced effectiveness. Direct oral anticoagulants can be used for anticoagulation in obese patients. With a body weight > 140 kg, a plasma level measurement is recommended. Severe overweight reduces the chances of successful ablation treatment and leads to more complications. Consistent treatment of the metabolic syndrome, and in particular weight reduction, can significantly improve the risk and the frequency of atrial fibrillation, the associated symptoms and the success of treatment for maintaining cardiac rhythm.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Metabolic Syndrome , Humans , Atrial Fibrillation/surgery , Catheter Ablation/methods , Metabolic Syndrome/complications , Metabolic Syndrome/drug therapy , Metabolic Syndrome/surgery , Overweight/complications , Overweight/drug therapy , Overweight/surgery , Anti-Arrhythmia Agents/therapeutic use , Anticoagulants/therapeutic use , Obesity/complications , Obesity/epidemiology , Obesity/surgery
16.
Eur Heart J Case Rep ; 6(9): ytac361, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36128440

ABSTRACT

Background: Pulsed field ablation (PFA) is a new feasible and safe method for the ablative treatment of cardiac arrhythmias, such as atrial fibrillation (AF). Through the use of electric fields, it causes pore-like openings in the cell's wall, leading to cell death. The most appealing characteristic of this new technique is its selectivity for cardiomyocytes and consequently its low risk of collateral damage to extracardiac tissues. We present three cases of a PFA-induced transient phrenic nerve (PN) injury documented during pulmonary vein isolation (PVI). Case summaries: Three patients aged 55-81 years underwent PFA for symptomatic AF. Cases 1 and 3 were affected by paroxysmal AF without evidence of structural heart disease. Case 2 had persistent AF and ischaemic cardiomyopathy with preserved ejection fraction. We observed a transient right hemidiaphragm palsy during the delivery of impulses in the right superior pulmonary vein (Cases 1 and 2) and in the right inferior pulmonary vein (Case 3). The palsy lasted <1 min and was followed by spontaneous full recovery in all cases. Discussion: Transient PN dysfunction can be observed following PFA in AF ablation. According to our initial experience, a full recovery of the PN function can be expected within seconds. We hypothesize a hyperpolarization of neuronal cells or a depletion of acetylcholine in the motoric endplate to explain this event. Further studies are required to understand the exact pathophysiological mechanism.

17.
J Interv Card Electrophysiol ; 65(3): 577-578, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36029430

ABSTRACT

We report a case of an incessant atrial tachycardia from the right atrial appendage that was effectively treated with pulsed field ablation after two failed radio frequency ablation attempts.


Subject(s)
Atrial Appendage , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Irreversible Electroporation Therapy
18.
J Arrhythm ; 38(3): 316-326, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35785393

ABSTRACT

Background: Left atrial appendage (LAA) isolation (LAAI) has been described as an adjunctive ablation strategy for patients with recurrent atrial tachyarrhythmia (ATa). Objectives: We compared the clinical impact of persistent durable LAAI between radiofrequency (RF)-guided wide-area LAAI and cryoballoon (CB)-guided ostial LAAI. Methods: Consecutive patients who underwent RF- or CB-guided LAAI were retrospectively analyzed. RF-guided LAAI was performed by combining linear ablation. CB-guided LAAI was performed by LAA ostial ablation. Following LAAI, the patients underwent an invasive remapping study. LAA closure was conducted if persistent durability was confirmed. The procedural data, LAAI durability, and ATa recurrence were assessed. Results: A total of 260 patients (RF: n = 201; CB: n = 59) undergoing LAAI were identified. The acute rate of procedural LAAI was higher in the CB group (CB:94.9% vs. RF:82.6%, p = .02) with a lower pericardial effusion incidence (CB:0% vs. RF:7.5%, p = .03). The 6-week durable LAAI was similar between the two groups (RF:78.3% vs. CB:66.0%, p = .103). During follow-up, one gastrointestinal bleeding and four stroke events including one subsequent intracranial bleeding leading to death occurred in the RF group, while one gastrointestinal bleeding occurred in the CB group.The 1-year ATa recurrence-free rate was higher in patients with durable LAAI following RF-guided LAAI (RF:76.3% vs. CB:56.7%, p = .0017). Multivariate analysis revealed RF-guided LAAI as a predictor of freedom from ATa recurrence (HR: 0.478, 95%CI: 0.336-0.823, p = .017). Conclusions: LAAI can be more readily and safely achieved by CB-guided ostial ablation. In patients with confirmed LAAI, however, the freedom from ATa recurrence was higher after RF-guided wide-area isolation.

19.
Pacing Clin Electrophysiol ; 45(12): 1383-1384, 2022 12.
Article in English | MEDLINE | ID: mdl-35821363

ABSTRACT

An 89-year-old woman underwent left atrial appendage (LAA) closure (LAAC) in our hospital because of recurrent gastrointestinal bleedings. The first transesophageal echocardiography (TEE) follow-up at six weeks revealed a complete sealing of the LAA and no device related thrombus. In a TEE follow-up at one year after the LAA closure, a large device related thrombus (6 × 3 cm) was found. Treated with oral anticoagulation (apixaban) the thrombus showed a partial resolution one year later.


Subject(s)
Atrial Appendage , Thrombosis , Aged, 80 and over , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery
20.
Circ Arrhythm Electrophysiol ; 15(6): e010817, 2022 06.
Article in English | MEDLINE | ID: mdl-35617232

ABSTRACT

BACKGROUND: Pulsed field ablation represents an energy source specific for ablation of cardiac arrhythmias including atrial fibrillation. The aim of the study was to describe the adoption and the process of streamlining procedures with a new ablation technology. METHODS: All-comer atrial fibrillation patients (n=191; mean age 69±12 years) underwent catheter ablation with a pulsed field ablation ablation device exclusively using analog-sedation. In the validation phase (n=25), device electrogram quality was compared with a circular mapping catheter to assess pulmonary vein isolation and esophageal temperature monitoring was used. In the streamline phase (n=166), a single-catheter approach was implemented. Postprocedural cerebral magnetic resonance imaging was performed in 53 patients. In 52 patients, esophageal endoscopy was performed at day 1 after the procedure. Follow-up was performed using 72 hours Holter ECGs. RESULTS: On a pulmonary vein basis, pulmonary vein isolation rate was 100% including a single shot isolation rate of 99.5%. The electrogram information of the pulsed field ablation catheter and the circular mapping catheter were 100% congruent. Neither esophageal temperature rises nor esophageal thermal injury were observed. Two minor strokes occurred, presumable due to air embolism during catheter exchanges through the large bore sheath (13.8 F ID). In the streamline phase, reduced procedure times (46±14 versus 38±13 minutes, P=0.004), no further strokes and a low incidence of silent cerebral injury (10/53 patients; 19%) were noted. During short-term follow-up, 17/191 patients (9%) had a atrial tachyarrhythmia recurrence. CONCLUSIONS: The pulsed field ablation device allows for simple and safe simple single shot pulmonary vein isolation using standard sedation protocols. Procedural speed and efficacy are remarkable and streamlining measures have added safety.