Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Physiotherapy ; 99(2): 107-12, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23219638

ABSTRACT

OBJECTIVES: Manual hyperinflation (MHI) has been shown to improve lung compliance, reduce airway resistance, and enhance secretion removal and peak expiratory flow. The aims of this study were to investigate whether there is a difference in airflow distribution through patients' lungs when using the Laerdal and Mapleson-C circuits at a set level of positive end-expiratory pressure (PEEP), and to establish whether differences in lung compliance and haemodynamic status exist when patients are treated with both these MHI circuits. DESIGN: Crossover randomised controlled trial. SETTING: Adult multidisciplinary intensive care unit (ICU) at an academic hospital. PARTICIPANTS: Fifteen adult patients were recruited and served as their own controls. INTERVENTION: In the Nuclear Medicine Department, MHI with PEEP 7.5 cmH(2)O was performed in the supine position (Day 1) with either Laerdal or Mapleson-C circuits, in a random order, while technetium-99m (Tc-99m) aerosol was administered and images were taken with a gamma camera. Changes in heart rate (HR), mean arterial pressure (MAP) and dynamic lung compliance (C(D)) were documented at baseline, immediately after return to ICU, and 10, 20 and 30 minutes after return to ICU. The alternative circuit was used on Day 2. RESULTS: Tc-99m deposition was greater in the right lung field (62% and 63% for Laerdal and Mapleson-C circuits, respectively) than the left lung field (38% and 37%, respectively) for all patients, and least deposition occurred in the left lower segments (6% and 6%, respectively). No differences in Tc-99m deposition in the lungs, HR, MAP or C(D) were noted between the two MHI circuits. CONCLUSION: Airflow distribution through patients' lungs was similar when the Laerdal and Mapleson-C MHI circuits were compared using a set level of PEEP in the supine position.


Subject(s)
Critical Illness/therapy , Lung Volume Measurements/methods , Positive-Pressure Respiration/methods , Radionuclide Imaging/methods , Adolescent , Adult , Aged , Airway Resistance/physiology , Cross-Over Studies , Female , Hemodynamics/physiology , Humans , Lung Compliance/physiology , Male , Middle Aged , Peak Expiratory Flow Rate/physiology , Technetium , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...