Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
J Anus Rectum Colon ; 8(2): 61-69, 2024.
Article in English | MEDLINE | ID: mdl-38689788

ABSTRACT

Objectives: Detailed superiority of CAD EYE (Fujifilm, Tokyo, Japan), an artificial intelligence for polyp detection/diagnosis, compared to endoscopists is not well examined. We examined endoscopist's ability using movie sets of colorectal lesions which were detected and diagnosed by CAD EYE accurately. Methods: Consecutive lesions of ≤10 mm were examined live by CAD EYE from March-June 2022 in our institution. Short unique movie sets of each lesion with and without CAD EYE were recorded simultaneously using two recorders for detection under white light imaging (WLI) and linked color imaging (LCI) and diagnosis under blue laser/light imaging (BLI). Excluding inappropriate movies, 100 lesions detected and diagnosed with CAD EYE accurately were evaluated. Movies without CAD EYE were evaluated first by three trainees and three experts. Subsequently, movies with CAD EYE were examined. The rates of accurate detection and diagnosis were evaluated for both movie sets. Results: Among 100 lesions (mean size: 4.7±2.6 mm; 67 neoplastic/33 hyperplastic), mean accurate detection rates of movies without or with CAD EYE were 78.7%/96.7% under WLI (p<0.01) and 91.3%/97.3% under LCI (p<0.01) for trainees and 85.3%/99.0% under WLI (p<0.01) and 92.6%/99.3% under LCI (p<0.01) for experts. Mean accurate diagnosis rates of movies without or with CAD EYE for BLI were 85.3%/100% for trainees (p<0.01) and 92.3%/100% for experts (p<0.01), respectively. The significant risk factors of not-detected lesions for trainees were right-sided, hyperplastic, not-reddish, in the corner, halation, and inadequate bowel preparation. Conclusions: Unique movie sets with and without CAD EYE could suggest it's efficacy for lesion detection/diagnosis.

2.
J Gastroenterol ; 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38466371

ABSTRACT

OBJECTIVE: Prevalence of colonoscopy (CS) is an important countermeasure against colorectal cancer (CRC). In this study, we used large-scale data for a comparison of CS with esophagogastroduodenoscopy (EGD) in Japan. METHODS: This was a retrospective descriptive study. Commercially anonymized patient data were collected from various health insurance societies (JMDC, Inc. Tokyo, Japan) generated from the insurance registry, receipts (inpatient, outpatient, and prescription), and health checkup data. The data also included healthy subjects who had never been examined in a hospital. The data of 2,760,048 persons who were 50-75 years old during January 2012-December 2019 were extracted from the original data source. The annual rate, the prevalence rate (frequency of those undergoing at least one endoscopy during the period), and the percentage of repeaters (undergoing endoscopy at least twice during the period) of CS were calculated and compared to those of EGD. RESULTS: The annual rates in 2012/2015/2019 were 3.4%/4.5%/5.3% for CS, respectively, and increased gradually from 2012 to 2019. Those rates were 7.0%/7.9%/7.4% for EGD, respectively, and did not increase. The prevalence rates of CS and EGD were 25.3% and 36.2%, respectively, among the 137,246 participants over 8 years. The prevalence rates of individuals in their 50 s/60 s/70 s were 23.0%/25.9%/31.4% for CS and 33.0%/37.6%/40.7% for EGD, respectively. The proportions of males/females were 27.9%/20.7% for CS, and 36.4%/35.8% for EGD, respectively. The repeat rates of CS and EGD were 40.3% and 44.8%, respectively, over 8 years. CONCLUSIONS: Using large-scale data, we determined the status of CS and EGD in Japan.

3.
JGH Open ; 8(1): e13029, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38268964

ABSTRACT

Background and Aim: A hemostatic gel, PuraStat (3-D Matrix, Tokyo, Japan), is used for various gastrointestinal hemostasis. In this study, we analyzed the efficacy of PuraStat for perioperative bleeding (POB) and prevention of delayed bleeding (DB) to colorectal cold snare polypectomy (CSP) with continuous anticoagulant. Methods: This was a single-center, retrospective study. Subjects were lesions of 2-9 mm under continuous anticoagulant from 2021 to 2023 and treated with PuraStat for POB. The definition of POB was bleeding which did not stop spontaneously by 1.0-1.5 min after resection and needed hemostasis. Successful hemostasis was defined as cessation of bleeding within 1.0-1.5 min after spraying PuraStat and the rate of it and risk factors of POB were analyzed. For comparison, cases receiving previous CSP without PuraStat were extracted from all cases with CSP (2018-2021), and POB and DB rate (DBR) were analyzed after propensity score matching. Results: One hundred twenty-two lesions (91: direct oral anticoagulant (DOAC), 31: warfarin) with anticoagulant were analyzed and the rate of successful hemostasis with PuraStat was 92.6% (DOAC/warfarin: 93.4%/80.6%, P = 0.01). The rate of DB was 0.0%. Multivariate analysis showed that significant risk factors about unsuccessful hemostasis for POB with PuraStat were lesion size 8-9 mm (P < 0.01), warfarin (P = 0.01), and combination of antiplatelet (P = 0.01). Regarding the comparison about CSP with/without PuraStat, the clipping rate and DBR were 8.5%/94.9% (P < 0.01) and 0%/1.7% (P = 1.0). Conclusion: The effects of PuraStat for POB and DB in colorectal CSP with continuous anticoagulant were acceptable.

4.
Am J Gastroenterol ; 2023 Oct 30.
Article in English | MEDLINE | ID: mdl-37782280

ABSTRACT

INTRODUCTION: The efficacy of texture and color enhancement imaging (TXI) in the novel light-emitting diode endoscopic system for polyp detection has not been examined. We aimed to evaluate the noninferiority of the additional 30-second (Add-30-s) observation of the right-sided colon (cecum/ascending colon) with TXI compared with narrow band imaging (NBI) for detecting missed polyps. METHODS: We enrolled 381 patients ≥40 years old who underwent colonoscopy from September 2021 to June 2022 in 3 institutions and randomly assigned them to either the TXI or NBI groups. The right-sided colon was first observed with white light imaging in both groups. Second, after reinsertion from hepatic flexure to the cecum, the right-sided colon was observed with Add-30-s observation of either TXI or NBI. The primary endpoint was to examine the noninferiority of TXI to NBI using the mean number of adenomas and sessile serrated lesions per patient. The secondary ones were to examine adenoma detection rate, adenoma and sessile serrated lesions detection rates, and polyp detection rates in both groups. RESULTS: The TXI and NBI groups consisted of 177 and 181 patients, respectively, and the noninferiorities of the mean number of adenomas and sessile serrated lesions per patients in the second observation were significant (TXI 0.29 [51/177] vs NBI 0.30 [54/181], P < 0.01). The change in adenoma detection rate, adenoma and sessile serrated lesions detection rate, and polyp detection rate for the right-sided colon between the TXI and NBI groups were not different (10.2%/10.5% [ P = 0.81], 13.0%/12.7% [ P = 0.71], and 15.3%/13.8% [ P = 0.71]), respectively. DISCUSSION: Regarding Add-30-s observation of the right-sided colon, TXI was noninferior to NBI.

5.
Gastroenterol Res Pract ; 2023: 6359165, 2023.
Article in English | MEDLINE | ID: mdl-37808965

ABSTRACT

Objectives: Oral sulfate solution (OSS) is used for bowel preparation (BP) during colonoscopy. The way of taking this agent can be used a same-day regimen (only on the day of colonoscopy) and split regimen (the day before and on the day of colonoscopy) for receiving it. In this study, we analyzed the efficacy of a same-day regimen of 480 ml OSS for insufficient bowel preparation (BP) with high-concentrated polyethylene glycol (H-PEG). Materials and Methods: This multicenter retrospective study was conducted from December 2021 to December 2022 at three related institutions on patients aged ≥ 20 years with a fair or poor Aronchick score of BP with 1 l H-PEG in previous colonoscopy. All patients received a low-residual diet and 10 ml of 0.75% picosulfate sodium a day before the colonoscopy and 480 ml of OSS and ≥1 l of water 3 hours before the colonoscopy. We analyzed the rate of improvement with OSS compared to H-PEG and other efficacies, and adverse events (AE). Results: We evaluated 125 cases (77 males) with an average age of 72.1 ± 8.8 years. The completion rate of 480 ml of OSS was 97.6% (122/125). The improvement rate of BP showing good or excellent score with OSS was 70.4% (88/125). Compared OSS with previous H-PEG, the insertion time (min) was 7.0 ± 4.8 vs. 8.1 ± 6.0 (p = 0.01), and the adenoma detection rates were 67.2% vs. 63.2% (p = 0.05). The cleansing time (min) was 131 ± 46 vs. 165 ± 53 (p < 0.01). The rate of AE with OSS was 10.4% (13/125). There were no significant differences about AE in age and gender. The tolerance of OSS compared with H-PEG (good/similar/bad) was 72.0%/24.8%/3.2% (amounts), 26.4%/39.2%/34.4% (taste), and 76.8%/10.4%/12.8% (overall preference), respectively. Conclusions: The same-day regimen of 480 ml OSS effectively improved the insufficient BP of 1 l H-PEG.

6.
Dig Dis Sci ; 68(10): 3943-3952, 2023 10.
Article in English | MEDLINE | ID: mdl-37558800

ABSTRACT

INTRODUCTION: In light-emitting diode (LED) and LASER colonoscopy, linked color imaging (LCI) and blue light/laser imaging (BLI) are used for lesion detection and characterization worldwide. We analyzed the difference of LCI and BLI images of colorectal lesions between LED and LASER in a multinational study. METHODS: We prospectively observed lesions with white light imaging (WLI), LCI, and BLI using both LED and LASER colonoscopies from January 2020 to August 2021. Images were graded by 27 endoscopists from nine countries using the polyp visibility score: 4 (excellent), 3 (good), 2 (fair), and 1 (poor) and the comparison score (LED better/similar/LASER better) for WLI/LCI/BLI images of each lesion. RESULTS: Finally, 32 lesions (polyp size: 20.0 ± 15.2 mm) including 9 serrated lesions, 13 adenomas, and 10 T1 cancers were evaluated. The polyp visibility scores of LCI/WLI for international and Japan-expert endoscopists were 3.17 ± 0.73/3.17 ± 0.79 (p = 0.92) and 3.34 ± 0.78/2.84 ± 1.22 (p < 0.01) for LED and 3.30 ± 0.71/3.12 ± 0.77 (p < 0.01) and 3.31 ± 0.82/2.78 ± 1.23 (p < 0.01) for LASER. Regarding the comparison of lesion visibility about between LED and LASER colonoscopy in international endoscopists, a significant difference was achieved not for WLI, but for LCI. The rates of LED better/similar/LASER better for brightness under WLI were 54.5%/31.6%/13.9% (International) and 75.0%/21.9%/3.1% (Japan expert). Those under LCI were 39.2%/35.4%/25.3% (International) and 31.3%/53.1%/15.6% (Japan expert). There were no significant differences in the diagnostic accuracy and the comparison score of BLI images between LED and LASER. CONCLUSIONS: The differences of lesion visibility for WLI/LCI/BLI between LED and LASER in international endoscopists could be compared to those in Japanese endoscopists.


Subject(s)
Adenoma , Colonic Polyps , Colorectal Neoplasms , Humans , Colonoscopy/methods , Colorectal Neoplasms/diagnostic imaging , Colorectal Neoplasms/pathology , Colonic Polyps/diagnostic imaging , Colonic Polyps/pathology , Adenoma/diagnostic imaging , Adenoma/pathology , Lasers , Color
7.
J Gastroenterol ; 58(11): 1105-1113, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37646980

ABSTRACT

BACKGROUND: Colorectal endoscopic resection (C-ER) is spreading due to the increase of colorectal cancer (CRC) in Japan. Gastric cancer (GC) sometimes occurs after C-ER. We aimed to analyze the status of GC after C-ER using large-scale data. METHODS: We retrospectively used commercially anonymized health insurance claims data of 5.71 million patients from 2005 to 2018, and extracted 62,392 patients ≥ 50 years old who received C-ER. The incidence and risk factors of GC were analyzed. Additionally, subjects were divided into ≥ 2 cm group and < 2 cm group and risks of GC were analyzed. RESULTS: The median age (range) was 58 (50-75) years and the overall rate of GC was 0.68% (423/62,392). Multivariate analysis showed that significant risk factors for GC [odds rates (OR), 95% confidence interval (CI)] were colorectal lesion size ≥ 2 cm (1.75, 1.24-2.47, p = 0.002), age ≥ 65 y.o. (1.65, 1.31-2.07, p < 0.001), male (2.35, 1. 76-3.13, p < 0.001), diabetes mellitus (1.40, 1.02-1.92, p = 0.035), liver disease (1.54, 1.06-2.24, p = 0.025), Helicobacter pylori infection (2.10, 1.65-2.67, p < 0.001), chronic atrophic gastritis (1.58, 1.14-2.18, p = 0.006), and CRC (1.72, 1.10-2.68, p = 0.017). The rate of GC in the ≥ 2 cm was significantly higher than that in < 2 cm groups (1.17% and 0.65%, p < 0.001). According to the number of significant risk factors, the rates of GC and the hazard ratios of GC (95%CI) were 0.64% and 3.64 (2.20-6.02) and 1.95% and 11.17 (6.57-19.00) for patient with 1-2 and ≥ 3 risk factors, compared with patients without risk factors. CONCLUSIONS: Using large-scale data, risk factors for GC, including colorecal lesions ≥ 2 cm after C-ER could be investigated.

8.
BMC Pregnancy Childbirth ; 23(1): 398, 2023 May 30.
Article in English | MEDLINE | ID: mdl-37254041

ABSTRACT

BACKGROUND: Person-centered maternity care is a component of quality care, which includes effective communication, respect, and dignity. Supportive care has a positive effect on mothers' perinatal experience. In contrast, negative childbirth experiences can cause psychological problems. However, the impact of person-centered maternity care experience on mothers' mental health after delivery remains unknown. Therefore, in this study, we examined the association between person-centered maternity care experience at healthcare facilities and maternal mental health after delivery among Nepali women. METHODS: We conducted a cross-sectional study in urban and rural areas in Dhading District, Nepal. Participants were women who gave birth at public healthcare facilities, and their baby's age was between 1 and 12 months. After purposively selecting the target areas, we recruited the women from July to August 2019 and interviewed them using questionnaires. We conducted multiple regression analyses to analyze the association between delivery care experience and depressive symptoms and the association between delivery care experience and mental well-being. RESULTS: In total, 595 women were included in the data analysis. The experience of better person-centered maternity care was associated with lower depressive symptom scores in urban (unstandardized coefficient [B]= - 0.09, p < 0.001) and rural areas (B= - 0.10, p < 0.001). Moreover, the experience of better person-centered maternity care was associated with higher mental well-being scores in both urban (B= 0.30, p < 0.001) and rural areas (B= 0.15, p = 0.017). CONCLUSIONS: Person-centered maternity care was associated with lower depressive symptom scores and higher mental well-being, regardless of the setting in Nepal. Person-centered maternity care during childbirth can potentially improve mental health after delivery. Maternity care should be improved with more attention to person-centered maternity care aspects.


Subject(s)
Maternal Health Services , Patient-Centered Care , Female , Humans , Infant , Male , Pregnancy , Cross-Sectional Studies , Mental Health , Nepal , Parturition/psychology
9.
Dig Dis Sci ; 68(5): 2030-2039, 2023 05.
Article in English | MEDLINE | ID: mdl-36881195

ABSTRACT

INTRODUCTION: SOUTEN (KANEKA Co., Tokyo, Japan) is a unique snare with a disk tip. We analyzed the efficacy of precutting endoscopic mucosal resection with SOUTEN (PEMR-S) for colorectal lesions. METHODS: We retrospectively reviewed 57 lesions of 10-30 mm treated with PEMR-S at our institution from 2017 to 2022. The indications were lesions that were difficult for standard EMR due to size, morphology, and poor elevation by injection. Various therapeutic results of PEMR-S such as en bloc resection, procedure time, and perioperative hemorrhage were analyzed, and the results of 20 lesions of 20-30 mm with PEMR-S were compared to those of lesions with standard EMR (2012-2014) using propensity score matching. Additionally, the stability of the SOUTEN disk tip was analyzed in a laboratory experiment. RESULTS: The polyp size was 16.5 ± 4.2 mm and the non-polypoid morphology rate was 80.7%. Histopathological diagnosis included 10 sessile-serrated lesions, 43 low-grade and high-grade dysplasias, and 4 T1 cancers. After matching, the en bloc resection and histopathological complete resection rates of lesions of 20-30 mm between PEMR-S and standard EMR (90.0% vs. 58.1%, p = 0.03 and 70.0% vs. 45.0%, p = 0.11). The procedure time (min) was 14.8 ± 9.7 and 9.7 ± 8.3 (p < 0.01). The en bloc resection (%) and procedure time of expert/non-expert were 89.7/85.7 (p = 0.96) and 6.1 ± 2.2/18.5 ± 7.2 (p < 0.01). The perioperative bleeding and hemostasis success rates with SOUTEN were 43.9% and 96.0%. In the experiment, the SOUTEN disk tip was fixed stably compared to other EMR snares. CONCLUSIONS: PEMR-S achieved high en bloc resection of colorectal lesions of 20-30 mm though it leaded to long procedure time.


Subject(s)
Adenoma , Colorectal Neoplasms , Endoscopic Mucosal Resection , Humans , Colonoscopy/methods , Retrospective Studies , Endoscopic Mucosal Resection/methods , Adenoma/surgery , Adenoma/pathology , Colorectal Neoplasms/surgery , Colorectal Neoplasms/pathology , Treatment Outcome , Intestinal Mucosa/surgery , Intestinal Mucosa/pathology
10.
Dig Endosc ; 34(7): 1413-1421, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35656632

ABSTRACT

OBJECTIVES: In light-emitting diode (LED) and laser colonoscopy, linked color imaging (LCI) superiority to white-light imaging (WLI) for polyp detection is shown separately. We analyzed the noninferiority of LCI between LED and laser colonoscopy and that of WLI (LECOL study). METHODS: We prospectively collected nonpolypoid lesions with WLI and LCI using LED and laser colonoscopy from January 2021 to August 2021. All images were evaluated randomly by 12 endoscopists (six nonexperts and six experts in three institutions) using the polyp visibility score: 4, excellent; 3, good; 2, fair; and 1, poor. The comparison score (LED better/similar/laser better) for redness and brightness was evaluated for WLI and LCI pictures of each lesion. RESULTS: Finally, 63 nonpolypoid lesions were evaluated, and the mean polyp size was 24.5 ± 13.4 mm. Histopathology revealed 13 serrated lesions and 50 adenomatous/cancerous lesions. The mean polyp visibility scores of LCI pictures were significantly higher than those of WLI in the LED (3.35 ± 0.85 vs. 3.08 ± 0.91, P < 0.001) and the laser (3.40 ± 1.71 vs. 3.05 ± 0.97, P < 0.001) group, and the noninferiority of LCI pictures between LED and laser was significant (P < 0.001). The comparison scores revealed that the evaluation of redness and brightness (LED better/similar/laser better) were 26.8%/40.1%/33.1% and 43.5%/43.5%/13.0% for LCI pictures (P < 0.001) and 20.6%/44.3%/35.1% and 60.3%/31.7%/8.0% for WLI pictures (P < 0.001), respectively. CONCLUSION: The noninferiority of polyp visibility with WLI and LCI in LED and laser colonoscopy was shown. WLI and LCI of LED tended to be brighter and less reddish than those of laser.


Subject(s)
Adenoma , Colorectal Neoplasms , Humans , Colonoscopy/methods , Adenoma/pathology , Narrow Band Imaging/methods , Lasers , Colorectal Neoplasms/diagnostic imaging , Colorectal Neoplasms/pathology , Color
11.
Gastroenterol Res Pract ; 2022: 9998280, 2022.
Article in English | MEDLINE | ID: mdl-35462983

ABSTRACT

Background: A compact and cost-effective light source-processor combined 3-color light-emitting diode (LED) endoscopic system (ELUXEO-Lite: EP-6000, Fujifilm Co., Tokyo) with a magnified colonoscope (EC-6600ZP, Fujifilm Co.) has been released. Aims: In this study, we analyzed the efficacy of this system for colorectal tumor characterization with magnified blue light imaging (BLI-LED) and image's subjective and objective evaluations, compared to a magnified blue laser imaging (BLI-LASER) using a standard LASER endoscopic system. Methods: We retrospectively reviewed 37 lesions observed with both BLI-LED and BLI-LASER systems from 2019 using the Japanese narrow band imaging classification. Two representative magnified images, one BLI-LED and one BLI-LASER, of the same area of a lesion were evaluated for diagnostic accuracy and visualization quality by three experts and three non-experts. Their color difference values (CDVs) and brightness values (BVs) were also calculated as objective indicators. Results: Among 37 lesions, mean tumor size was 18.9 ± 13.1 mm, and 21 lesions were nonpolypoid. Histopathology revealed 14 sessile serrated lesions, 7 adenomas, 12 high-grade dysplasias and T1a cancers, and 4 T1b cancers. The diagnostic accuracy rates of BLI-LED/BLI-LASER of experts and non-experts were 90.1% and 87.4% (p = 0.52) and 89.2% and 89.2% (p = 0.99). The percentages of instances where BLI-LED images were better, the two imaging types were equivalent, or BLI-LASER images were better were 16%/83%/1% for experts and 19%/58%/23% for non-experts (p < 0.001). CDVs and BVs between BLI-LED and BLI-LASER were not significantly different (CDVs: p = 0.653, BVs: p = 0.518). Conclusions: BLI-LED using the compact system was noninferior to BLI-LASER for colorectal tumor characterization and image quality.

12.
DEN Open ; 2(1): e47, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35310751

ABSTRACT

An endoscope system using 5-color light-emitting diodes (LEDs) (EVIS X1: CV-1500, Olympus Co., Tokyo, Japan) was released worldwide in July 2020. In addition to the improvement of narrow band imaging (NBI), this system enables texture and color enhancement imaging (TXI). TXI makes the lesion reddish and supports better visibility of colorectal lesions in comparison to white light imaging for improving lesion detection. On the other hand, another 4-color LED endoscope system (ELUXEO: BL-7000; Fujifilm, Tokyo, Japan) has been on the market in the West since 2017. This system enables blue light imaging (BLI) and linked color imaging (LCI). Generally, the accurate comparison between two images obtained by two different endoscope systems is difficult. To resolve this problem, we developed a method named the tablet-image comparison (TIC) method. TIC is a simple, easy, and paperless method to get images under similar conditions of two endoscope systems for an accurate comparison. We herein report two colorectal lesions in which accurate comparisons of images between TXI and LCI and between improved NBI and BLI obtained in the EVIS X1 and ELUXEO systems were performed using the TIC method. One was IIa 30 mm (high-grade dysplasia) and the other was IIa 25 mm (low-grade adenoma). A detailed comparison between TXI and LCI could be performed by TIC. In these two cases, with a distant view, TXI showed greater redness than LCI. LCI showed slightly higher brightness than TXI. In magnified TXI and LCI, the irregularities observed were similar to NBI and BLI, respectively.

13.
Case Rep Gastroenterol ; 16(1): 37-43, 2022.
Article in English | MEDLINE | ID: mdl-35350675

ABSTRACT

Case Report: A 65-year-old man without any symptoms received colonoscopy for cancer screening and underwent cold snare polypectomy (CSP) for a 3-mm rectal lesion at a local clinic. A histopathological examination revealed neuroendocrine tumor (NET) G1 with a positive margin. The patient was referred to our hospital for further treatment. Then, the post-CSP scar was removed by endoscopic submucosal dissection (ESD), with a sufficient endoscopically normal margin. Histopathology showed 4 NETs and endocrine cell micronests (ECMs) distant from the post-CSP scar, with a positive lateral margin. We considered that the possibility of other NETs was high. Additional surgery was performed. After a histopathological examination, 11 NETs and ECMs were found in the whole rectum, without lymph node metastasis. The patient had no recurrence at 24 months after surgery. In the past 10 years, we have experienced 4 cases (including the present case) of multiple rectal NETs among 56 cases of rectal NETs of ≤10 mm (7.1%). None of our 4 cases showed any recurrence (follow-up period: 12-32 months). Conclusions: We herein report a case involving a patient with 15 rectal NETs and ECMs. We reviewed our experience with multiple rectal NETs, and the rate of multiple rectal NETs was 7.1%. Endoscopists should consider that multiple lesions may be present in cases of rectal NET and be aware that some cannot be detected endoscopically.

14.
Dig Dis Sci ; 67(12): 5657-5665, 2022 12.
Article in English | MEDLINE | ID: mdl-35318554

ABSTRACT

INTRODUCTION: An endoscopic system using 5-color light-emitting diodes (LEDs) (EVIS X1; Olympus Co., Tokyo, Japan), which includes texture and color enhancement imaging (TXI), has been released. In this study, we analyzed the effects of TXI on the visibility of non-polypoid colorectal lesions and its diagnostic accuracy. METHODS: We reviewed 101 non-polypoid lesions from 26 patients observed with white light imaging (WLI), narrow band imaging (NBI), and TXI. One representative image of each mode was evaluated by 6 endoscopists using a polyp visibility score of 4 (excellent) to 1 (poor). We calculated the color difference (CD) values for each lesion in the three modes. For tumor characteristics, one representative image of TXI and NBI magnification was evaluated by 3 experts according to a NBI classification. RESULTS: The least squares means [95% confidence interval] of polyp visibility score of TXI (3.42 [3.06-3.77]) was significantly higher than that of WLI (2.85 [2.49-3.20], p < 0.001) but not that of NBI (3.33 [2.98-3.69], p = 0.258). The CD value of TXI (13.3 ± 6.3) was higher than that of WLI (9.7 ± 6.0, p < 0.001) but not that of NBI (13.1 ± 6.8, p = 0.81). For sessile serrated lesions, the CD value of TXI (11.1 ± 4.4) tended to be lower than that of NBI (12.6 ± 6.0, p = 0.07). The diagnostic accuracy and confidence level of magnification for NBI were significantly better than those for TXI (87.1 vs. 80.5%, p = 0.027, 87.5 vs. 62.7%, p < 0.001, respectively). CONCLUSION: TXI showed better visibility than WLI in terms of the endoscopist's score and CD value and may improve polyp detection.


Subject(s)
Colonic Polyps , Colorectal Neoplasms , Humans , Colonic Polyps/diagnosis , Colonoscopy/methods , Narrow Band Imaging/methods , Colorectal Neoplasms/diagnostic imaging , Colorectal Neoplasms/pathology , Japan , Image Enhancement/methods , Color
15.
Indian J Gastroenterol ; 41(2): 149-159, 2022 04.
Article in English | MEDLINE | ID: mdl-35201600

ABSTRACT

INTRODUCTION: Technical issues and long procedure time still remain a concern in colorectal endoscopic submucosal dissection (ESD). We examined the usefulness of combining the pocket-creation method (PCM) with a traction device (S-O clip; SO) using a scissor-type knife (Clutch Cutter 3.5 mm; CC) for decreasing ESD procedure time. METHODS: We retrospectively analyzed 95 ESD cases of PCM + SO + CC managed from August 2017 to April 2020 and 103 cases of PCM + CC treated from July 2016 to July 2017. We compared these two groups through propensity score matching. The main outcome was the analysis of the ESD procedure times under various conditions in each group. RESULTS: After matching, 52 cases in the PCM + SO + CC and PCM + CC groups were analyzed. The PCM + SO + CC group showed a significantly shorter ESD procedure time than the PCM + CC group (57.8 ± 31.4 vs. 81.7 ± 33.5 min, p < 0.01). Additionally, the ESD procedure time was significantly shorter in the PCM + SO + CC group than in the PCM + CC group: tumor size (tumor size < 40 mm: 45.6 ± 15.8 vs. 72.7 ± 22.9 min, p < 0.01; tumor size ≥ 40 mm: 83.1 ± 40.1 vs. 111.8 ± 45.3 min, p = 0.04), tumor location (right side: 64.7 ± 33.3 vs. 81.0 ± 29.7 min, p = 0.03; left side: 50.5 ± 28.0 vs. 82.3 ± 36.9 min, p < 0.01), tumor morphology (polypoid: 39.2 ± 18.6 vs. 74.7 ± 28.6 min, p < 0.01; nonpolypoid: 62.3 ± 32.3 vs. 84.5 ± 35.2 min, p < 0.01), endoscopist (expert: 67.3 ± 41.2 vs. 91.9 ± 40.2 min, p = 0.02; nonexpert: 50.4 ± 18.3 vs. 73.6 ± 24.9 min, p < 0.01), and fibrosis (severe fibrosis: 82.0 ± 20.5 vs. 99.8 ± 40.4 min, p = 0.169; non-severe fibrosis: 52.1 ± 23.8 vs. 75.6 ± 29.0 min, p < 0.01). CONCLUSIONS: The combination of the PCM and SO using CC achieved a reduction in the colorectal ESD procedure time.


Subject(s)
Colorectal Neoplasms , Endoscopic Mucosal Resection , Colorectal Neoplasms/surgery , Endoscopic Mucosal Resection/methods , Fibrosis , Humans , Retrospective Studies , Traction , Treatment Outcome
16.
Dig Dis Sci ; 67(7): 3192-3199, 2022 07.
Article in English | MEDLINE | ID: mdl-34731360

ABSTRACT

BACKGROUND AND AIMS: Recurrence after cold snare polypectomy (CSP) sometimes occurs. We assessed the feasibility of repeat CSP for recurrence after CSP. METHODS: We retrospectively reviewed recurrent lesions after CSP which were resected by repeat CSP from 2016 to 2021 in our institution and analyzed clinical outcomes of repeat CSP, comparing those of non-recurrent 454 lesions receiving standard CSP in 2016 and follow-up colonoscopy. We also analyzed the recurrent rate among cases receiving follow-up in both groups. Indication of repeat CSP was lesions diagnosed as benign tumors of ≤ 10 mm. RESULTS: We analyzed 80 lesions receiving repeat CSP. The polyp size (mean ± standard deviation: SD) was 4.1 ± 2.3 mm (range 2-10 mm). The right-sided colon and non-polypoid morphology rates were 66.3% and 43.8%, respectively. Histopathological diagnosis was 66 adenomas, 12 sessile serrated lesions (SSLs), 1 SSL with dysplasia, and 1 high-grade dysplasia. The procedure time (min, mean ± SD) of repeat CSP was 0.9 ± 0.8. Regarding the comparison of repeat CSP/ standard CSP group, the en bloc resection and histopathological complete resection rates were 78.8%/ 98.0% (p < 0.001) and 43.8%/59.6% (p = 0.007) and the rates of perioperative hemorrhage requiring endoscopic clipping were 1.3%/ 1.0% (p = 0.646). There were no postoperative hemorrhage and perforation in both groups (p = 1.0). Among lesions receiving follow-up colonoscopy, the mean recurrence rates (number, median follow-up period: interquartile) of repeat CSP and standard CSP group were 2.0% (1/50, 12 months: 12-24) versus 0.7% (3/454, 12 months: 12-24) (p = 0.862). CONCLUSIONS: Repeat CSP for benign recurrent lesions after CSP was safe and feasible.


Subject(s)
Adenoma , Colonic Polyps , Adenoma/pathology , Adenoma/surgery , Colonic Polyps/pathology , Colonic Polyps/surgery , Colonoscopy , Humans , Postoperative Hemorrhage/etiology , Postoperative Hemorrhage/surgery , Retrospective Studies
17.
Int J Colorectal Dis ; 36(10): 2237-2245, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34406437

ABSTRACT

OBJECTIVES: Recently, CAD EYE (Fujifilm, Tokyo, Japan), an artificial intelligence for the lesion recognition (CADe) and the optical diagnosis (CADx) of colorectal polyps, was released. We evaluated the function of CADe and CADx of CAD EYE. METHODS: In this single-center retrospective study, we examined consecutive polyps ≤ 10 mm detected from March to April 2021 to determine whether CAD EYE could recognize them live with both normal- and high-speed observation using white-light imaging (WLI) and linked-color imaging (LCI). We then examined whether the polyps were neoplastic or hyperplastic live with magnified or non-magnified blue-laser imaging (BLI-LASER) or blue-light imaging (BLI-LED) under CAD EYE, comparing the retrospective evaluations with 5 experts and 5 trainees using still images. All polyps were histopathologically examined. RESULTS: We analyzed 100 polyps (mean size 3.9 ± 2.6 mm; 55 neoplastic and 45 hyperplastic lesions) in 25 patients. Regarding CADe, the respective detection rates of CAD EYE with normal- and high-speed observation were 85.0% and 67.0% for WLI (p = 0.002) and 89.0% and 75.0% for LCI (p = 0.009). Regarding CADx for differentiating neoplastic and hyperplastic lesions, the diagnostic accuracy values of CAD EYE with non-magnified and magnified BLI-LASER/LED were 88.8% and 87.8%. Regarding magnified BLI-LASER/LED, the diagnostic accuracy value of CAD EYE was not significantly different from that of experts (92.0%, p = 0.17), but that of trainees (79.0%, p = 0.04). We also found no significant differences in CADe or CADx between LED (53 lesions) and LASER (47 lesions). CONCLUSIONS: CAD EYE was a helpful tool for CADe and CADx in clinical practice.


Subject(s)
Colonic Polyps , Artificial Intelligence , Colonic Polyps/diagnostic imaging , Colonoscopy , Humans , Narrow Band Imaging , Retrospective Studies
18.
United European Gastroenterol J ; 9(3): 370-377, 2021 04.
Article in English | MEDLINE | ID: mdl-33045938

ABSTRACT

BACKGROUND AND AIM: Cold snare polypectomy (CSP) is growing in popularity due to its safety and convenience. Its indication is benign tumours such as adenoma and sessile serrated lesions (SSLs) <10 mm in size. CSP for SSLs ≥10 mm in size has not been well examined. In this study, we aimed the feasibility of this treatment regarding therapeutic results and local recurrence. METHODS: This was a single-centre retrospective cohort study. We reviewed SSLs with or without dysplasia of 10-20 mm that were resected by CSP from 2014 to 2020. All tumours were diagnosed endoscopically as SSLs without dysplasia before CSP with the help of magnifying narrow band imaging or blue laser imaging. We analysed the lesion characteristics, en bloc resection, histopathological diagnosis, adverse events and local recurrence. We analysed risk factors for recurrence, comparing recurrent lesions to non-recurrent lesions. We also compared risk factors for lesions 10-14 mm in size to those for lesions 15-20 mm in size. RESULTS: We analysed 160 lesions in 100 patients (Mage  ± SD = 67.7 ± 10.1 years). The polyp size (M ± SD) was 11.8 ± 2.8 mm, and the en bloc resection rate was 60.0% (96 cases). The rates of massive perioperative haemorrhage, postoperative haemorrhage and perforation were 1.3%, 0% and 0%, respectively. Regarding histopathological diagnosis, two (1.2%) cases showed SSLs with high-grade dysplasia. The recurrence rate in 101 lesions with a median follow-up period of 18 months (interquartile range 12-24 months) was 5.0%. There were no significant risk factors such as tumour size, location, morphology and so on in terms of recurrence. All recurrent cases could be resected by repeat CSP. The recurrence rates of lesions 10-14 mm in size and 15-20 mm in size were 4.7% and 6.3%, respectively (p = 0.713). CONCLUSION: CSP of SSLs ≥10 mm in size according to magnifying endoscopic diagnosis was safe and promising, but the rate of recurrence was slightly high, meaning that close follow-up is required.


Subject(s)
Colonic Polyps/surgery , Adult , Aged , Aged, 80 and over , Colonic Polyps/diagnostic imaging , Colonic Polyps/pathology , Colonoscopy/adverse effects , Colonoscopy/methods , Feasibility Studies , Female , Follow-Up Studies , Humans , Intestinal Perforation/epidemiology , Intraoperative Complications/epidemiology , Male , Middle Aged , Narrow Band Imaging , Postoperative Hemorrhage/epidemiology , Recurrence , Retrospective Studies , Risk Factors
19.
Gastroenterol Res Pract ; 2020: 8886073, 2020.
Article in English | MEDLINE | ID: mdl-33299407

ABSTRACT

MATERIALS AND METHODS: This multicenter retrospective study was conducted from September 2019 to September 2020 at 5 related institutions among patients ≥ 20 years old diagnosed with chronic constipation whose previous colonoscopic BP had had a fair or poor Aronchick score. Two or four sachets of PEG+E (13.7 or 27.4 g/day) were prescribed for 1 week before colonoscopy. We analyzed the rate of improvement in BP, effect-related factors, spontaneous bowel movements (SBMs), stool consistency, improvement of constipation symptoms, and adverse events. RESULTS: We evaluated 106 cases (56 males) with an average age of 69.5 ± 9.4 years old (≤74 years old: 68 cases, ≥75 years old: 38 cases). The improvement rate of BP was 72.6%, and the insertion time and pain score also improved. A performance status of 1 or 2 was associated with poor BP. SBMs (times/week) increased from 4.0 ± 1.9 to 6.1 ± 2.6 (p < 0.001). The overall improvement rates of SBMs, stool consistency, symptoms of constipation, and rate of adverse events were 58.5%, 90.6%, 59.4%, and 6.6%, respectively, showing no significant differences with regard to age or gender. CONCLUSIONS: Short-duration PEG+E was effective for improving poor BP and chronic constipation.

20.
BMJ Open ; 9(11): e029988, 2019 11 03.
Article in English | MEDLINE | ID: mdl-31685498

ABSTRACT

BACKGROUND: Migration is a stressful process of resettlement and acculturation that can often negatively impact the mental health of migrants. International migration to Japan, a country with dominant ethnic homogeneity, is growing steadily amid an ageing domestic population and severe labour shortages. OBJECTIVES: To identify the contemporary barriers to, and facilitators of, mental well-being among the migrant population in Japan. DESIGN: Systematic review DATA SOURCES: PubMed, ProQuest, Web of Science, Ichushi and J-Stage ELIGIBILITY CRITERIA: Research articles examining the mental well-being of international migrants in Japan that were published in English or Japanese between January 2000 and September 2018 were included. DATA EXTRACTION AND SYNTHESIS: Full texts of relevant articles were screened and references of the included studies were hand-searched for further admissible articles. Study characteristics, mental well-being facilitators and barriers, as well as policy recommendations were synthesised into categorical observations and were then thematically analysed. RESULTS: Fifty-five studies (23 published in English), surveying a total of 8649 migrants, were identified. The most commonly studied migrant nationalities were Brazilian (36%), followed by Chinese (27%) and Filipino (8%). Thematic analysis of barriers to mental well-being among migrants chiefly identified 'language difficulties', 'being female' and 'lack of social support', whereas the primary facilitators were 'social networks' followed by 'cultural identity'. Policy recommendations for authorities generally described more migrant support services and cross-cultural awareness among the Japanese public. CONCLUSION: Access to social support networks of various types appears to be an influential factor affecting the mental well-being of international migrants in Japan. More research is necessary on how to promote such connections to foster a more inclusive and multicultural Japanese society amid rapid demographic change. PROSPERO REGISTRATION NUMBER: CRD42018108421.


Subject(s)
Ethnicity/psychology , Mental Disorders/epidemiology , Mental Disorders/psychology , Transients and Migrants/psychology , Acculturation , China/ethnology , Humans , Japan/epidemiology , Philippines/ethnology , Sex Factors , Social Support
SELECTION OF CITATIONS
SEARCH DETAIL
...