Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Coll Cardiol ; 80(8): 766-778, 2022 08 23.
Article in English | MEDLINE | ID: mdl-35981821

ABSTRACT

BACKGROUND: Nonadherence to antiplatelet therapy after percutaneous coronary intervention (PCI) is common, even in clinical trials. OBJECTIVES: The purpose of this study was to investigate the impact of nonadherence to study protocol regimens in the MASTER DAPT (Management of High Bleeding Risk Patients Post Bioresorbable Polymer Coated Stent Implantation With an Abbreviated Versus Prolonged DAPT Regimen) trial. METHODS: At 1-month after PCI, 4,579 high bleeding risk patients were randomized to single antiplatelet therapy (SAPT) for 11 months (or 5 months in patients on oral anticoagulation [OAC]) or dual antiplatelet therapy (DAPT) for ≥2 months followed by SAPT. Coprimary outcomes included net adverse clinical events (NACE), major adverse cardiac and cerebral events (MACE), and major or clinically relevant nonmajor bleeding (MCB) at 335 days. Inverse probability-of-censoring weights were used to correct for nonadherence Academic Research Consortium type 2 or 3. RESULTS: In total, 464 (20.2%) patients in the abbreviated-treatment and 214 (9.4%) in the standard-treatment groups incurred nonadherence Academic Research Consortium type 2 or 3. At inverse probability-of-censoring weights analyses, NACE (HR: 1.01; 95% CI: 0.88-1.27) or MACE (HR: 1.07; 95% CI: 0.83-1.40) did not differ, and MCB was lower with abbreviated compared with standard treatment (HR: 0.51; 95% CI: 0.60-0.73) consistently across OAC subgroups; among OAC patients, SAPT discontinuation 6 months after PCI was associated with similar MACE and lower MCB (HR: 0.47; 95% CI: 0.22-0.99) compared with SAPT continuation. CONCLUSIONS: In the MASTER DAPT adherent population, 1-month compared with ≥3-month DAPT was associated with similar NACE or MACE and lower MCB. Among OAC patients, SAPT discontinuation after 6 months was associated with similar MACE and lower MCB than SAPT continuation (Management of High Bleeding Risk Patients Post Bioresorbable Polymer Coated Stent Implantation With an Abbreviated Versus Prolonged DAPT Regimen [MASTER DAPT]; NCT03023020).


Subject(s)
Drug-Eluting Stents , Percutaneous Coronary Intervention , Drug Therapy, Combination , Drug-Eluting Stents/adverse effects , Hemorrhage/chemically induced , Hemorrhage/drug therapy , Hemorrhage/epidemiology , Humans , Medication Adherence , Percutaneous Coronary Intervention/methods , Platelet Aggregation Inhibitors/therapeutic use , Polymers , Treatment Outcome
2.
Front Cardiovasc Med ; 9: 882854, 2022.
Article in English | MEDLINE | ID: mdl-35686043

ABSTRACT

Introduction: Severe aortic stenosis, a highly-common valve disease in the elderly, has a poor prognosis if left untreated. To address the concern of effective procedures for severe aortic stenosis, a systematic TAVI program was established at the Dedinje Cardiovascular Institute (Belgrade, Serbia). Methods: Our cohort was composed of 56 patients (74±15 years old). The mean logistic EuroScore was 10.17%; the mean Society of Thoracic Surgeons score was 3.22%. One third of the patients were categorized as class III or IV of the New York Heart Association (NYHA). The valves selected for use were either self-expandable or balloon expandable (Evolut R, Medtronic; Acurate Neo, Boston Scientific and Myval, Meril). The choice of valve type was made by the Institute's Structural Heart Team, in accordance with the patient's native aortic valve, size and calcification of ilio-femoral vessels, as well as the need for alternative access. TAVI procedure was conducted according to current guidelines provided by the European Society of Cardiology. Results: The procedure success rate was 100%. Trans-femoral approach was achieved in 100% of patients; percutaneously in 87.5%, while a surgical cut was necessary in 12.5%. No patient showed moderate or severe aortic regurgitation after the procedure, although trace or mild regurgitation was recorded in 30.3%. Permanent pacemaker was implanted in one patient (1.78%), contrast induced acute kidney injury occured in one patient (1.78%), no stroke was recorded, and three pseudo-aneurysms which required surgical intervention occurred. Three patients required blood transfusions (5.33%). A 30-day all-cause mortality rate was 1.78%. Conclusion: The Dedinje Cardiovascular Institute spearheaded all efforts to establish a TAVI program in Serbia. Our initial TAVI results are promising, encouraging, and comparable with the results of previous large randomized trials. This initial experience opens the door for further development with a goal of our Institute to become a high-volume TAVI center.

3.
Catheter Cardiovasc Interv ; 72(7): 901-8, 2008 Dec 01.
Article in English | MEDLINE | ID: mdl-19016466

ABSTRACT

OBJECTIVES: The aim of this study was to assess the pharmacokinetics and tolerability of Biolimus A9 eluted from Nobori coronary stents. BACKGROUND: : The release kinetics and pharmacokinetics of drugs delivered via coronary stents have been shown to play an essential role in the efficacy and safety of drug eluting stents. METHODS: Twenty patients with coronary artery disease were treated with single 14-mm (10 patients) or 28-mm long stent (10 patients). Blood samples were drawn at 16 time points to determine the pharmacokinetics of Biolimus A9. At seven time points, complete laboratory and toxicology panels were assessed to screen for potential Biolimus A9 toxicity. The primary endpoint of the study was the systemic blood concentrations of Biolimus A9 after 28 days and 6 months as measured using highly specific and sensitive liquid chromatography- tandem mass spectrometry assay. RESULTS: At 28 days, 6 patients (30%) had quantifiable Biolimus A9 concentrations in blood. The highest Biolimus A9 blood concentration measured in any sample was 32.2 pg/mL. The median time to maximum concentration was 2 hr, ranging from 0.05 hr to 3 months. Six months after stent implantation, only 1 of 20 patients had measurable Biolimus A9 concentrations at the lowest level of quantification, while at 9 months no sample had quantifiable Biolimus A9 concentrations. Laboratory and toxicology assessments did not indicate any impact of Biolimus A9 on the evaluated parameters. CONCLUSION: Results of this study suggest that systemic exposure to Biolimus A9 was very low and that Biolimus A9 was well tolerated.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/pharmacokinetics , Coronary Artery Disease/therapy , Drug-Eluting Stents , Sirolimus/analogs & derivatives , Cardiovascular Agents/administration & dosage , Cardiovascular Agents/adverse effects , Cardiovascular Agents/blood , Chromatography, Liquid , Colorado , Coronary Artery Disease/drug therapy , Female , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Design , Serbia , Sirolimus/administration & dosage , Sirolimus/adverse effects , Sirolimus/blood , Sirolimus/pharmacokinetics , Tandem Mass Spectrometry , Treatment Outcome
4.
J Am Coll Cardiol ; 51(22): 2123-9, 2008 Jun 03.
Article in English | MEDLINE | ID: mdl-18510958

ABSTRACT

OBJECTIVES: The aim of our study was to compare coronary vasomotion after implantation of a second-generation biolimus A9-eluting stent (BES) and of a sirolimus-eluting stent (SES). BACKGROUND: Drug-eluting stents (DES) have been associated with impaired local coronary vasomotion, delayed endothelialization, and increased late thrombotic risk. New DES with different drugs, pharmacokinetics, and polymers have been developed. METHODS: Nineteen patients with a BES and 15 patients with a SES were studied 9 months after stent implantation. Endothelium-dependent and -independent coronary vasomotion were tested proximally and distally to the stent as well as at a reference segment during right atrial pacing at increasing heart rates. Quantitative coronary angiographic measurements were performed offline. RESULTS: Of the patients with BES, 2 showed vasoconstriction with increased heart rate and 17 showed vasodilatation. Of the patients with a SES, 9 showed vasoconstriction while 6 showed vasodilatation. The SES showed significant vasoconstriction at both the proximal (-2.3 +/- 10% vs. 7.9 +/- 10%) and the distal (-5.4 +/- 9% vs. 6.1 +/- 8%) segments to the stent compared with the BES (p = 0.003 for proximal, p < 0.001 for distal segment). Endothelium-independent vasomotion after intracoronary nitrates did not differ significantly between the 2 groups (p = NS for proximal and distal segment). CONCLUSIONS: Unlike the case with the SES, endothelium-dependent vasomotion at adjacent stent segments seems to be preserved after BES implantation. This result may be explained by the different drug release kinetics, DES design, or characteristics of polymer used in the stent system.


Subject(s)
Coronary Vessels/physiopathology , Drug-Eluting Stents , Endothelium, Vascular/physiopathology , Immunosuppressive Agents/therapeutic use , Paclitaxel/therapeutic use , Sirolimus/analogs & derivatives , Sirolimus/therapeutic use , Vasoconstriction/drug effects , Vasodilation/drug effects , Coronary Angiography , Coronary Vessels/drug effects , Endothelium, Vascular/drug effects , Female , Hemodynamics , Humans , Immunosuppressive Agents/pharmacology , Male , Middle Aged , Paclitaxel/pharmacology , Prospective Studies , Sirolimus/pharmacology
5.
EuroIntervention ; 3(5): 574-9, 2008 Mar.
Article in English | MEDLINE | ID: mdl-19608483

ABSTRACT

AIM: To compare clinical efficacy and safety of stents eluting limus drugs from biodegradable polymer - Nobori, or durable polymer - Cypher. METHODS AND RESULTS: From May to August 2006, 107 patients with 142 coronary artery lesions were treated with either Nobori, Biolimus A9 eluting stent (54) or Cypher, Sirolimus eluting stent (53) in five centres. The two groups were well matched for baseline clinical and angiographic characteristics. The in-stent late loss at nine months, the primary endpoint of the study, was 0.10+/-0.26 mm in Nobori, and 0.13+/-0.44 mm in Cypher arm (p=0.660) confirming the hypothesis of the similarity between the two stents. In-stent diameter stenosis of 13+/-10% with Nobori was significantly lower than 20+/-12% with Cypher stent (p=0.002) without significant difference in binary restenosis (1.7% in Nobori and 6.3% in Cypher arm; p=0.32). The rate of major adverse cardiac events at 12 months was 1.9% with Nobori and 4.1% with Cypher stent. CONCLUSIONS: The nine months angiographic data from Nobori Core study demonstrate that Biolimus A9 has similar anti-proliferative efficacy to Sirolimus as judged by in-stent late loss and restenosis rate. Low frequency of adverse cardiac events at 12 months indicates that both stents are safe and effective in the studied population.

SELECTION OF CITATIONS
SEARCH DETAIL
...