Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters











Database
Language
Publication year range
1.
Leukemia ; 29(2): 369-76, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25036192

ABSTRACT

Serial quantification of BCR-ABL1 mRNA is an important therapeutic indicator in chronic myeloid leukaemia, but there is a substantial variation in results reported by different laboratories. To improve comparability, an internationally accepted plasmid certified reference material (CRM) was developed according to ISO Guide 34:2009. Fragments of BCR-ABL1 (e14a2 mRNA fusion), BCR and GUSB transcripts were amplified and cloned into pUC18 to yield plasmid pIRMM0099. Six different linearised plasmid solutions were produced with the following copy number concentrations, assigned by digital PCR, and expanded uncertainties: 1.08±0.13 × 10(6), 1.08±0.11 × 10(5), 1.03±0.10 × 10(4), 1.02±0.09 × 10(3), 1.04±0.10 × 10(2) and 10.0±1.5 copies/µl. The certification of the material for the number of specific DNA fragments per plasmid, copy number concentration of the plasmid solutions and the assessment of inter-unit heterogeneity and stability were performed according to ISO Guide 35:2006. Two suitability studies performed by 63 BCR-ABL1 testing laboratories demonstrated that this set of 6 plasmid CRMs can help to standardise a number of measured transcripts of e14a2 BCR-ABL1 and three control genes (ABL1, BCR and GUSB). The set of six plasmid CRMs is distributed worldwide by the Institute for Reference Materials and Measurements (Belgium) and its authorised distributors (https://ec.europa.eu/jrc/en/reference-materials/catalogue/; CRM code ERM-AD623a-f).


Subject(s)
Fusion Proteins, bcr-abl/genetics , Fusion Proteins, bcr-abl/metabolism , Plasmids/genetics , Real-Time Polymerase Chain Reaction/standards , Calibration , Cloning, Molecular , DNA , Escherichia coli Proteins/genetics , Gene Dosage , Humans , Membrane Transport Proteins/genetics , Proto-Oncogene Proteins c-bcr/genetics , RNA, Messenger/metabolism , Reference Standards
2.
Anal Bioanal Chem ; 404(1): 29-42, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22638881

ABSTRACT

The reliable quantification of genetically modified organisms (GMOs) by real-time PCR requires, besides thoroughly validated quantitative detection methods, sustainable calibration systems. The latter establishes the anchor points for the measured value and the measurement unit, respectively. In this paper, the suitability of two types of DNA calibrants, i.e. plasmid DNA and genomic DNA extracted from plant leaves, for the certification of the GMO content in reference materials as copy number ratio between two targeted DNA sequences was investigated. The PCR efficiencies and coefficients of determination of the calibration curves as well as the measured copy number ratios for three powder certified reference materials (CRMs), namely ERM-BF415e (NK603 maize), ERM-BF425c (356043 soya), and ERM-BF427c (98140 maize), originally certified for their mass fraction of GMO, were compared for both types of calibrants. In all three systems investigated, the PCR efficiencies of plasmid DNA were slightly closer to the PCR efficiencies observed for the genomic DNA extracted from seed powders rather than those of the genomic DNA extracted from leaves. Although the mean DNA copy number ratios for each CRM overlapped within their uncertainties, the DNA copy number ratios were significantly different using the two types of calibrants. Based on these observations, both plasmid and leaf genomic DNA calibrants would be technically suitable as anchor points for the calibration of the real-time PCR methods applied in this study. However, the most suitable approach to establish a sustainable traceability chain is to fix a reference system based on plasmid DNA.


Subject(s)
DNA, Plant/genetics , Genomics/methods , Plants, Genetically Modified/genetics , Plasmids/genetics , Zea mays/genetics , Calibration , Gene Dosage , Genomics/standards
3.
Anal Bioanal Chem ; 378(5): 1168-74, 2004 Mar.
Article in English | MEDLINE | ID: mdl-14513194

ABSTRACT

Over the years, the nature of CRMs has changed considerably. Recently, more and more CRMs have been certified in their "natural" form, that is processed as little as possible, with analytes at their natural concentration level. This and the trend towards certified properties other than the concentrations of clearly defined molecules/elements have made guaranteeing stability of CRMs and estimating a shelf life an even more important issue for reference material producers than it has been before. One way to meet this challenge is to take more care in processing, storage and dispatch of CRMs. At IRMM, approximately 20 % of the RMs are stored at -20 degrees C or below and about 10% require cooled transportation. In addition, increased efforts for assessing stability are needed. Shelf lives are estimated using addition of an uncertainty component based on real-temperature stability studies rather than by accelerated stability studies. These pre-certification efforts are complemented by a stability-monitoring program, which at IRMM includes 80 % of the non-nuclear and non-isotopic materials. Although the costs for these efforts are high in absolute terms, they are only a minor and indispensable contribution to the total costs of CRM production.

4.
Vet Rec ; 149(19): 577-82, 2001 Nov 10.
Article in English | MEDLINE | ID: mdl-11730165

ABSTRACT

The efficacy of a rapid test for detecting PrP(Sc) in central nervous system tissue was evaluated for the postmortem diagnosis of BSE at different times during the course of the disease. One hundred and six samples of brain, at the level of the medulla oblongata, and spinal cord, derived from the experimental study of the pathogenesis of BSE carried out in Great Britain between 1991 and 1995, were examined. PrP(Sc) was detected in the samples from most of the exposed animals killed 32 months or more after they had been exposed to the agent, and before the onset of clinical signs which were first recorded at 35 months. Comparisons with the results of histology, fibril detection, PrP immunohistochemistry and mouse bioassay indicated that the rapid test is at least as sensitive as these conventional confirmatory diagnostic methods and its result can be obtained more quickly.


Subject(s)
Central Nervous System/pathology , Encephalopathy, Bovine Spongiform/diagnosis , PrPSc Proteins/analysis , Animals , Autopsy/veterinary , Cattle , Immunohistochemistry , PrPSc Proteins/immunology , Sensitivity and Specificity
5.
Fresenius J Anal Chem ; 370(7): 935-9, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11569879

ABSTRACT

Homogeneity testing and the determination of minimum sample mass are an important part of the certification of reference materials. The smallest theoretically achievable uncertainty of certified concentration values is limited by the concentration distribution of analyte in the different particle size fractions of powdered biological samples. This might be of special importance if the reference material is prepared by dry mixing, a dilution technique which is used for the production of the new and third generation of genetically modified (GMO) plant certified reference materials. For the production of dry mixed PMON 810 maize reference material a computer program was developed to calculate the theoretically smallest uncertainty for a selected sample intake. This model was used to compare three differently milled maize samples, and the effect of dilution on the uncertainty of the DNA content of GMO maize was estimated as well. In the case of a 50-mg sample mass the lowest achievable standard deviation was 2% for the sample containing 0.1% GMO and the minimum deviation was less than 0.5% for the sample containing 5% GMO.


Subject(s)
DNA/analysis , Zea mays/chemistry , Genetic Engineering , Reference Standards , Zea mays/genetics
6.
Fresenius J Anal Chem ; 370(2-3): 142-6, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11451225

ABSTRACT

In the execution of its mission to promote a common European measurement system in support of EU policies, IRMM's Reference Materials Unit is currently involved in preparation of proficiency-testing samples and candidate reference materials. Recent work related to bovine spongiform encephalopathy in cows, genetically modified organisms, and a variety of environmental materials is described.


Subject(s)
Encephalopathy, Bovine Spongiform/diagnosis , Food Analysis/standards , Reference Standards , Animals , Cattle , European Union , Food Analysis/methods , International Cooperation , Plants, Genetically Modified/chemistry , Glycine max/chemistry , Glycine max/genetics , Glycine max/standards , Zea mays/chemistry , Zea mays/genetics , Zea mays/standards
7.
Environ Sci Pollut Res Int ; 5(1): 17-20, 1998.
Article in English | MEDLINE | ID: mdl-19002623

ABSTRACT

Chloroplast thylakoids are used as biological units to determine herbicides in different kinds of water samples as well as in aqueous extracts of compost, soil or food samples. The thylakoid bioassay shows clearly inhibition of fluorescence yield in the presence of photosystem II specific herbicides. Due to this method the ecotoxicological effect of samples with unknown pollutants can be tested fast and cost effective. It has been proven that all photosynthetic active compounds are recorded at the same time because only additive interactions occur. Therefore, the contamination level can be expressed as cumulative parameter for photosystem II active substances. Application was improved clearly by the addition of the radical scavenger sodium ascorbate to the isolation media and by a higher concentration of the measuring medium. A new data evaluation method is described yielding in a lower detection limit of 0.4 microg diuron/1. The guidelines for the quality of water for human consumption with an allowable concentration of pesticides in groups is 0,5 microg/1 and can be controlled with the thylakoid bioassay without performing any preconcentration steps.

SELECTION OF CITATIONS
SEARCH DETAIL