Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 82
Filter
1.
Rev Esp Cardiol (Engl Ed) ; 76(12): 1021-1031, 2023 Dec.
Article in English, Spanish | MEDLINE | ID: mdl-37863184

ABSTRACT

INTRODUCTION AND OBJECTIVES: This article presents the annual activity report of the Interventional Cardiology Association of the Spanish Society of Cardiology (ACI-SEC) for the year 2022. METHODS: All Spanish centers with catheterization laboratories were invited to participate. Data were collected online and were analyzed by an external company in collaboration with the members of the board of the ACI-SEC. RESULTS: A total of 111 centers participated. The number of diagnostic studies increased by 4.8% compared with 2021, while that of percutaneous coronary interventions (PCI) remained stable. PCIs on the left main coronary artery increased by 22%. The radial approach continued to be preferred for PCI (94.9%). There was an upsurge in the use of drug-eluting balloons, as well as in intracoronary imaging techniques, which were used in 14.7% of PCIs. The use of pressure wires also increased (6.3% vs 2021) as did plaque modification techniques. Primary PCI continued to grow and was the most frequent treatment (97%) in ST-segment elevation myocardial infarction. Most noncoronary procedures maintained their upward trend, particularly percutaneous aortic valve implantation, atrial appendage closure, mitral/tricuspid edge-to-edge therapy, renal denervation, and percutaneous treatment of pulmonary arterial disease. CONCLUSIONS: The Spanish cardiac catheterization and coronary intervention registry for 2022 reveals a rise in the complexity of coronary disease, along with a notable growth in procedures for valvular and nonvalvular structural heart disease.


Subject(s)
Cardiology , Coronary Artery Disease , Percutaneous Coronary Intervention , Humans , Cardiac Catheterization , Registries
2.
Int J Cardiol ; 373: 1-6, 2023 02 15.
Article in English | MEDLINE | ID: mdl-36435331

ABSTRACT

BACKGROUND: Some patients with spontaneous coronary artery dissection (SCAD) present as ST-segment-elevation myocardial infarction (STEMI). This study evaluates the characteristics, management and outcomes of SCAD patients presenting as STEMI compared to non-ST-segment elevation myocardial infarction (NSTEMI). METHODS: We analysed data from consecutive patients included in the prospective Spanish Registry on SCAD. All coronary angiograms were centrally reviewed. All adverse events were adjudicated by an independent Clinical Events Committee. RESULTS: Between June 2015 to December 2020, 389 patients were included. Forty-two percent presented with STEMI and 56% with NSTEMI. STEMI patients showed a worse distal flow (TIMI flow 0-1 38% vs 19%, p < 0.001) and more severe (% diameter stenosis 85 ± 18 vs 75 ± 21, p < 0.001) and longer (42 ± 23 mm vs 35 ± 24 mm, p = 0.006) lesions. Patients with STEMI were more frequently treated with percutaneous coronary intervention (PCI) (31% vs 16%, p < 0.001) and developed more frequently left ventricular systolic dysfunction (21% vs 8%, p < 0.001). No differences were found in combined major adverse events during admission (7% vs 5%, p = 0.463), but in-hospital reinfarctions (5% vs 1.4%, p = 0.039) and cardiogenic shock (2.6% vs 0%, p = 0.019) were more frequently seen in the STEMI group. At late follow-up (median 29 months) no differences were found in the incidence of major adverse cardiac and cerebrovascular events (13% vs 13%, p-value = 0.882) between groups. CONCLUSIONS: Patients with SCAD and STEMI had a worse angiographic profile and were more frequently referred to PCI compared to NSTEMI patients. Despite these disparities, both short and long-term prognosis were similar in STEMI and NSTEMI SCAD patients.


Subject(s)
Non-ST Elevated Myocardial Infarction , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , ST Elevation Myocardial Infarction/diagnostic imaging , ST Elevation Myocardial Infarction/epidemiology , Non-ST Elevated Myocardial Infarction/diagnostic imaging , Non-ST Elevated Myocardial Infarction/epidemiology , Percutaneous Coronary Intervention/adverse effects , Coronary Vessels , Risk Factors , Prospective Studies , Treatment Outcome
3.
Rev. esp. cardiol. (Ed. impr.) ; 75(12): 1001-1010, dic. 2022. tab, graf, ilus
Article in Spanish | IBECS | ID: ibc-212933

ABSTRACT

Introducción y objetivos: En insuficiencia cardiaca persistente con insuficiencia mitral (IM) secundaria se debe considerar la reparación transcatéter borde-a-borde (TEER) de la válvula mitral. Los inhibidores de neprilisina (ARNIs) demostraron mejorar el pronóstico en insuficiencia cardiaca. Nuestro objetivo fue evaluar el impacto de los ARNIs en la selección y resultados. Métodos: La población del registro nacional de TEER (marzo/2012-enero/2021) se dividió en 2 grupos: a) TEER pre-ARNI (n=450) y b) TEER una vez que los ARNIs se recomendaron en guías europeas (n=639), teniendo en cuenta si se prescribieron (n=52) o no (n=587). Resultados: Un total de 1.089 pacientes consecutivos se sometieron a TEER para el tratamiento de la IM. Presentaron menor tamaño ventricular izquierdo (100 frente a 82mL, p=0,025) y mejor función (35 frente a 38%, p=0,011) en la era ARNI. A los 2 años, la mortalidad (10,6 frente a 17,3%, p <0,001) y los ingresos por insuficiencia cardiaca (16,6 frente a 27,8%, p <0,001) fueron menores, pero no la recurrencia de IM. En la era ARNI, la mortalidad fue comparable independientemente de la prescripción de ARNIs, pero tuvieron menor tasa de muerte+re-hospitalización a 2 años (OR=0,369, IC95%, 0,137-0,992, p=0,048), mejor NYHA y menor recurrencia de IM (1,9 frente al 14,3%, p=0,011). Conclusiones: Se observó una mejor selección y resultados en candidatos a TEER en la era ARNI y su prescripción se asoció a una reducción significativa de eventos globales, mejor NYHA y menor recurrencia de la IM.(AU)


Introduction and objectives: Transcatheter edge-to-edge repair (TEER) should be considered in patients with heart failure and secondary mitral regurgitation (MR). Angiotensin receptor-neprilysin inhibitors (ARNIs) have been demonstrated to improve prognosis in heart failure. We aimed to evaluate the impact ARNIs on patient selection and outcomes. Methods: The population of the Spanish TEER prospective registry (March 2012 to January 2021) was divided into 2 groups: a) TEER before the ARNI era (n=450) and b) TEER after the recommendation of ARNIs by European Guidelines (n=639), with further analysis according to intake (n=52) or not (n=587) of ARNIs. Results: A total of 1089 consecutive patients underwent TEER for secondary MR. In the ARNI era, there was a reduction in left ventricle dilation (82mL vs 100mL, P=.025), and better function (35% vs 38%, P=.011). At 2 years of follow-up, mortality (10.6% vs 17.3%, P <.001) and heart failure readmissions (16.6% vs 27.8%, P <.001) were lower in the ARNI era, but not recurrent MR. In the ARNI era, 1- and 2-year mortality were similar irrespective of ARNI intake but patients on ARNIs had a lower risk of readmission+mortality at 2 years (OR, 0.369; 95%CI, 0.137-0.992; P=.048), better NYHA class, and lower recurrence of MR III-IV (1.9% vs 14.3%, P=.011). Conclusions: Better patient selection for TEER has been achieved in the last few years with a parallel improvement in outcomes. The use of ARNIs was associated with a significant reduction in overall events, better NYHA class, and lower MR recurrence.(AU)


Subject(s)
Humans , Male , Female , Neprilysin , Receptors, Angiotensin , Heart Failure , Mitral Valve Insufficiency , Mitral Valve , Cardiology , Heart Diseases
4.
Hellenic J Cardiol ; 66: 1-10, 2022.
Article in English | MEDLINE | ID: mdl-35513299

ABSTRACT

BACKGROUND: Renal dysfunction in patients with ST-elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (pPCI) indicates a poor long-term prognosis. However, the prognostic value of the improvement or stabilisation of renal function during follow-up has not yet been assessed. This study aimed to investigate the long-term predictive impact of the improvement or stabilisation of renal function after one year of follow-up in patients with STEMI undergoing pPCI with renal dysfunction at discharge. METHODS: This prospective, single-centre cohort study included 2170 consecutive patients with STEMI who underwent pPCI. The glomerular filtration rate (GFR) was determined at hospital discharge and one-year follow-up. The median clinical follow-up was 72 months. RESULTS: Among the 2004 patients, 393 (19.6%) had a GFR <60 ml/min, and 1611 (80.4%) had a GFR ≥ 60 ml/min at discharge. Among patients with GFR <60 ml/min, data at one-year follow-up were available for 342. Of these patients, 127 (32%) showed improvement in renal function (defined as improvement in the Kidney Disease Improving Global Outcomes (KDIGO) chronic kidney disease (CKD) classification), 47 (12%) showed worsening of renal function (defined as worsening of the KDIGO CKD classification), and 168 (43%) showed no category changes. Improvement or stabilisation of GFR at one year of follow-up was associated with a reduction of major adverse cardiovascular events (MACE) [HR 0.51, 95% CI: 0.35-0.75, p = 0.001] and all-cause mortality [HR 0.54, 95% CI: 0.34-0.84, p = 0.007] during follow-up. CONCLUSIONS: The improvement or stabilisation of renal function at one-year follow-up in patients with STEMI and renal dysfunction is associated with a better long-term prognosis.


Subject(s)
Percutaneous Coronary Intervention , Renal Insufficiency, Chronic , ST Elevation Myocardial Infarction , Cohort Studies , Humans , Kidney/physiology , Percutaneous Coronary Intervention/adverse effects , Prognosis , Prospective Studies , Registries , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/epidemiology , Risk Factors , ST Elevation Myocardial Infarction/complications , ST Elevation Myocardial Infarction/surgery
5.
Rev Esp Cardiol (Engl Ed) ; 75(12): 1001-1010, 2022 Dec.
Article in English, Spanish | MEDLINE | ID: mdl-35272968

ABSTRACT

INTRODUCTION AND OBJECTIVES: Transcatheter edge-to-edge repair (TEER) should be considered in patients with heart failure and secondary mitral regurgitation (MR). Angiotensin receptor-neprilysin inhibitors (ARNIs) have been demonstrated to improve prognosis in heart failure. We aimed to evaluate the impact ARNIs on patient selection and outcomes. METHODS: The population of the Spanish TEER prospective registry (March 2012 to January 2021) was divided into 2 groups: a) TEER before the ARNI era (n=450) and b) TEER after the recommendation of ARNIs by European Guidelines (n=639), with further analysis according to intake (n=52) or not (n=587) of ARNIs. RESULTS: A total of 1089 consecutive patients underwent TEER for secondary MR. In the ARNI era, there was a reduction in left ventricle dilation (82mL vs 100mL, P=.025), and better function (35% vs 38%, P=.011). At 2 years of follow-up, mortality (10.6% vs 17.3%, P <.001) and heart failure readmissions (16.6% vs 27.8%, P <.001) were lower in the ARNI era, but not recurrent MR. In the ARNI era, 1- and 2-year mortality were similar irrespective of ARNI intake but patients on ARNIs had a lower risk of readmission+mortality at 2 years (OR, 0.369; 95%CI, 0.137-0.992; P=.048), better NYHA class, and lower recurrence of MR III-IV (1.9% vs 14.3%, P=.011). CONCLUSIONS: Better patient selection for TEER has been achieved in the last few years with a parallel improvement in outcomes. The use of ARNIs was associated with a significant reduction in overall events, better NYHA class, and lower MR recurrence.


Subject(s)
Heart Failure , Mitral Valve Insufficiency , Neprilysin , Humans , Heart Failure/drug therapy , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/drug therapy , Mitral Valve Insufficiency/surgery , Neprilysin/antagonists & inhibitors , Receptors, Angiotensin , Treatment Outcome
6.
Catheter Cardiovasc Interv ; 99(4): 961-967, 2022 03.
Article in English | MEDLINE | ID: mdl-34962059

ABSTRACT

OBJECTIVES: The aim of this analysis was to assess the effect of the coronary revascularization strategy during index admission on clinical outcomes among patients undergoing percutaneous coronary intervention (PCI) with multivessel coronary artery disease (MVD). BACKGROUND: The value of complete revascularization (CR) over incomplete revascularization (IR) in MVD patients is not fully established. METHODS: Patients with MVD defined as ≥2 major epicardial vessels with ≥50% stenosis were selected from the observational all-comer e-Ultimaster registry. Patients were treated with a sirolimus-eluting thin-strut coronary stent. Completeness of revascularization was physician assessed at the index procedure or an eventually staged procedure during the index hospitalization. Outcomes measures at 1 year were target lesion failure (TLF) (composite of cardiac death, target vessel-related myocardial infarction [MI], and clinically driven target lesion revascularization [TLR]), and patient-oriented composite endpoint (POCE) (all-cause mortality, MI, or revascularization). The inverse probability of treatment weights (IPTW) methodology was used to perform a matched analysis. RESULTS: The registry recruited 37,198 patients of whom 15,441 (41.5%) had MVD. CR on hospital discharge was achieved in 7413 (48.0%) patients and IR in 8028 (52.0%) patients. Mean age was 64.6 ± 11.1 versus 65.7 ± 11.0 years (p < 0.01), male gender 77.9% and 77.3% (p = 0.41) and diabetes 31.3% versus 33.4% (p = 0.01) for CR and IR, respectively. Chronic stable angina patients more commonly underwent CR (47.6% vs. 36.8%, p < 0.01). After propensity weighted analysis, 90.5% of CR patients were angina-free at 1 year compared with 87.5% of IR patients (p < 0.01). TLF (3.3% vs. 4.4%; p < 0.01), POCE (6.8% vs. 10.8%; p < .01), and all-cause mortality (2.3% vs. 3.1%; p < .01) were all lower in CR patients. CONCLUSIONS: A physician-directed use of a CR strategy utilizing sirolimus-eluting thin-strut stent results in optimized clinical outcomes and less angina in an all-comer population. Our findings suggest that a CR should be aimed for.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Aged , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/etiology , Coronary Artery Disease/therapy , Humans , Male , Middle Aged , Myocardial Infarction/etiology , Registries , Risk Factors , Sirolimus/adverse effects , Treatment Outcome
7.
Eur Heart J Acute Cardiovasc Care ; 10(8): 898-908, 2021 Oct 27.
Article in English | MEDLINE | ID: mdl-34327531

ABSTRACT

AIMS: Left ventricular ejection fraction (LVEF) recovery after an ST-segment elevation myocardial infarction (STEMI) identifies a group of patients with a better prognosis. However, the association between long-term outcomes and LVEF recovery among patients with STEMI undergoing primary percutaneous coronary intervention (PCI) has not yet been well investigated. Our study aims to detect differences in long-term all-cause and cardiovascular mortality between patients who recover LVEF at 1-year post-PCI and those who do not, and search for predictors of LVEF recovery. METHODS AND RESULTS: This is a retrospective, single-centre study of 2170 consecutive patients admitted for STEMI in which primary PCI is performed. LVEF was determined at admission and at 1-year follow-up. The primary outcomes were long-term all-cause and cardiovascular mortality. Among the 2168 patients with baseline LVEF data, 822 (38%) had a LVEF < 50% and 1346 (62%) ≥ 50%. Among those with LVEF < 50%, LVEF data at 1-year were available in 554, and 299 (54.0%) presented with complete recovery (LVEF ≥ 50%). LVEF recovery was associated with a reduction in long-term all-cause and cardiovascular mortality (P < 0.0001). Female sex, treatment with ACEIs, lower creatinine levels, infarct-related artery different from the left main or left anterior descendent artery, and absence of prior ischaemic heart disease were independently associated with LVEF recovery. CONCLUSIONS: Nearly 40% of patients with STEMI undergoing primary PCI presented with LVEF depression at hospital admission. Among them, LVEF recovery at 1-year occurred in more than 50% and was independently associated with a significant decrease in long-term all-cause and cardiovascular mortality.


Subject(s)
Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Female , Humans , Prognosis , Registries , Retrospective Studies , ST Elevation Myocardial Infarction/diagnosis , ST Elevation Myocardial Infarction/surgery , Stroke Volume , Ventricular Function, Left
8.
J Am Coll Cardiol ; 77(17): 2187-2199, 2021 05 04.
Article in English | MEDLINE | ID: mdl-33926655

ABSTRACT

BACKGROUND: Among patients with acute coronary syndrome following transcatheter aortic valve replacement (TAVR), those presenting with ST-segment elevation myocardial infarction (STEMI) are at highest risk. OBJECTIVES: The goal of this study was to determine the clinical characteristics, management, and outcomes of STEMI after TAVR. METHODS: This was a multicenter study including 118 patients presenting with STEMI at a median of 255 days (interquartile range: 9 to 680 days) after TAVR. Procedural features of STEMI after TAVR managed with primary percutaneous coronary intervention (PCI) were compared with all-comer STEMI: 439 non-TAVR patients who had primary PCI within the 2 weeks before and after each post-TAVR STEMI case in 5 participating centers from different countries. RESULTS: Median door-to-balloon time was higher in TAVR patients (40 min [interquartile range: 25 to 57 min] vs. 30 min [interquartile range: 25 to 35 min]; p = 0.003). Procedural time, fluoroscopy time, dose-area product, and contrast volume were also higher in TAVR patients (p < 0.01 for all). PCI failure occurred more frequently in patients with previous TAVR (16.5% vs. 3.9%; p < 0.001), including 5 patients in whom the culprit lesion was not revascularized owing to coronary ostia cannulation failure. In-hospital and late (median of 7 months [interquartile range: 1 to 21 months]) mortality rates were 25.4% and 42.4%, respectively (20.6% and 38.2% in primary PCI patients), and estimated glomerular filtration rate <60 ml/min (hazard ratio [HR]: 3.02; 95% confidence interval [CI]: 1.42 to 6.43; p = 0.004), Killip class ≥2 (HR: 2.74; 95% CI: 1.37 to 5.49; p = 0.004), and PCI failure (HR: 3.23; 95% CI: 1.42 to 7.31; p = 0.005) determined an increased risk. CONCLUSIONS: STEMI after TAVR was associated with very high in-hospital and mid-term mortality. Longer door-to-balloon times and a higher PCI failure rate were observed in TAVR patients, partially due to coronary access issues specific to the TAVR population, and this was associated with poorer outcomes.


Subject(s)
Aortic Valve Stenosis/surgery , Postoperative Complications/etiology , Risk Assessment/methods , ST Elevation Myocardial Infarction/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Aged, 80 and over , Coronary Angiography , Female , Follow-Up Studies , Global Health , Hospital Mortality/trends , Humans , Incidence , Male , Percutaneous Coronary Intervention , Postoperative Complications/epidemiology , Risk Factors , ST Elevation Myocardial Infarction/diagnosis , ST Elevation Myocardial Infarction/epidemiology , Time Factors
9.
J Clin Med ; 10(5)2021 Mar 02.
Article in English | MEDLINE | ID: mdl-33801311

ABSTRACT

BACKGROUND: Transcatheter mitral valve repair (TMVR) is an effective therapy for high-risk patients with severe mitral regurgitation (MR) but heart failure (HF) readmissions and death remain substantial on mid-term follow-up. Recently, right ventricular (RV) to pulmonary arterial (PA) coupling has emerged as a relevant prognostic predictor in HF. In this study, we aimed to assess the prognostic value of tricuspid annular plane systolic excursion (TAPSE) to PA systolic pressure (PASP) ratio as a non-invasive measure of RV-to-PA coupling in patients undergoing TMVR with MitraClip (Abbott, CA, USA). METHODS: Multicentre registry including 228 consecutive patients that underwent successful TMVR with MitraClip. The sample was divided in two groups according to TAPSE/PASP median value: 0.35. The primary combined endpoint encompassed HF readmissions and all-cause mortality. RESULTS: Mean age was 72.5 ± 11.5 years and 154 (67.5%) patients were male. HF readmissions and all-cause mortality were more frequent in patients with TAPSE/PASP ≤ 0.35: Log-Rank 8.844, p = 0.003. On Cox regression, TAPSE/PASP emerged as a prognostic predictor of the primary combined endpoint, together with STS-Score. TAPSE/PASP was a better prognostic predictor than either TAPSE or PASP separately. CONCLUSIONS: TAPSE/PASP ratio appears as a novel prognostic predictor in patients undergoing MitraClip implantation that might improve risk stratification and candidate selection.

10.
Circ Cardiovasc Interv ; 14(2): e009342, 2021 02.
Article in English | MEDLINE | ID: mdl-33541099

ABSTRACT

BACKGROUND: Limited data are available regarding change in the nutritional status after transcatheter aortic valve replacement (TAVR). This study evaluated the prognostic impact of the change in the geriatric nutritional risk index following TAVR. METHODS: TAVR patients were analyzed in a prospective and observational study. To analyze the change in nutritional status, geriatric nutritional risk index of the patients was calculated on the day of TAVR and at 3-month follow-up. The impact of the change in nutritional risk index after TAVR on all-cause mortality, heart failure hospitalization (HF-h), and the composite of all-cause death and HF hospitalization was analyzed using the Cox Proportional Hazards model. RESULTS: Four hundred thirty-three patients were included. After TAVR, 68.4% (n=182) patients with baseline nutritional risk improved compared with 31.6% (n=84) who remained at nutritional risk. The change from no-nutritional risk to nutritional risk after TAVR occurred in 15.0% (n=25), while 85.0% (n=142) remained without risk of malnutrition. During follow-up, 157 (36.3%) patients died and 172 patients (39.7%) were hospitalized due to HF. Patients who continued to be at nutritional risk had a higher risk of mortality (hazard ratio [HR], 2.10 [95% CI, 1.30-3.39], P=0.002), HF-h (HR, 1.97 [95% CI, 1.26-3.06], P=0.000), and the composite of death and HF-h (HR, 2.0 [95% CI, 1.37-2.91], P<0.001). The change to non-nutritional risk after TAVR significantly impacted mortality (HR, 0.48 [95% CI, 0.30-0.78], P=0.003), HF-h (HR, 0.50 [95% CI, 0.34-0.74], P=0.001), and the composite outcome (HR, 0.44 [95% CI, 0.32-0.62], P<0.001). CONCLUSIONS: Remaining at nutritional risk after TAVR confers a poor prognosis and is associated with an increased risk of mortality and HF-h, while the change from risk of malnutrition to non-nutritional risk after TAVR was associated with a halving of the risk of mortality and HF-h. Further studies are needed to identify whether patients at nutritional risk would benefit from nutritional intervention during processes of care of TAVR programs.


Subject(s)
Aortic Valve Stenosis , Heart Failure , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Heart Failure/therapy , Humans , Prognosis , Prospective Studies , Risk Factors , Severity of Illness Index , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
11.
Circulation ; 142(25): 2431-2442, 2020 12 22.
Article in English | MEDLINE | ID: mdl-33054367

ABSTRACT

BACKGROUND: Few randomized trials have compared bioprostheses for transcatheter aortic valve replacement, and no trials have compared bioprostheses with supra-annular design. The SCOPE 2 trial (Safety and Efficacy Comparison of Two TAVI Systems in a Prospective Randomized Evaluation 2) was designed to compare the clinical outcomes of the ACURATE neo and CoreValve Evolut bioprostheses for transcatheter aortic valve replacement. METHODS: SCOPE 2 was a randomized trial performed at 23 centers in 6 countries between April 2017 and April 2019. Patients ≥75 years old with an indication for transfemoral transcatheter aortic valve replacement as agreed by the heart team were randomly assigned to receive treatment with either the ACURATE neo (n=398) or the CoreValve Evolut bioprostheses (n=398). The primary end point, powered for noninferiority of the ACURATE neo bioprosthesis, was all-cause death or stroke at 1 year. The key secondary end point, powered for superiority of the ACURATE neo bioprosthesis, was new permanent pacemaker implantation at 30 days. RESULTS: Among 796 randomized patients (mean age, 83.2±4.3 years; mean Society of Thoracic Surgeons Predicted Risk of Mortality score, 4.6±2.9%), clinical follow-up information was available for 778 (98%) patients. Within 1 year, the primary end point occurred in 15.8% of patients in the ACURATE neo group and in 13.9% of patients in the CoreValve Evolut group (absolute risk difference, 1.8%, upper 1-sided 95% confidence limit, 6.1%; P=0.0549 for noninferiority). The 30-day rates of new permanent pacemaker implantation were 10.5% in the ACURATE neo group and 18.0% in the CoreValve Evolut group (absolute risk difference, -7.5% [95% CI, -12.4 to -2.60]; P=0.0027). No significant differences were observed in the components of the primary end point. Cardiac death at 30 days (2.8% versus 0.8%; P=0.03) and 1 year (8.4% versus 3.9%; P=0.01), and moderate or severe aortic regurgitation at 30 days (10% versus 3%; P=0.002) were significantly increased in the ACURATE neo group. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement with the self-expanding ACURATE neo did not meet noninferiority compared with the self-expanding CoreValve Evolut in terms of all-cause death or stroke at 1 year, and it was associated with a lower incidence of new permanent pacemaker implantation. In secondary analyses, the ACURATE neo was associated with more moderate or severe aortic regurgitation at 30 days and cardiac death at 30 days and 1 year. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03192813.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Europe , Female , Hemodynamics , Humans , Male , Prosthesis Design , Recovery of Function , Risk Assessment , Risk Factors , Severity of Illness Index , Stroke/etiology , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
12.
Heart ; 2020 Aug 25.
Article in English | MEDLINE | ID: mdl-32843495

ABSTRACT

OBJECTIVE: The aim of this work is to assess the relationship between significant paravalvular leak (SPL) after transcatheter aortic valve implantation (TAVI) on anaemia and their impact on prognosis. METHODS: Observational analytic study developed at two university hospitals, including all consecutive patients who underwent TAVI during a 10-year period (2009 to 2018). A logistic regression model was created to determine independent predictors of anaemia at 3 months. Time to event outcomes were analysed with Cox regression. Median follow-up was 21.3±21.9 months. RESULTS: 788 patients were included. 5.3% had SPL. SPL was an independent predictor of anaemia 3 months after TAVI (OR: 8.31, 95% CI: 2.06 to 33.50). SPL and anaemia at 3 months were independently associated with long-term mortality (HR: 1.82, 95% CI: 1.16 to 2.85; HR: 2.07, 95% CI: 1.39 to 3.08). CONCLUSION: SPL is an independent predictor of anaemia at 3 months after TAVI, a condition that doubles long-term mortality. Our findings could explain in part the worse prognosis of SPL after TAVI. Further pathophysiological studies are necessary to explain this association.

13.
Rev. esp. cardiol. (Ed. impr.) ; 73(8): 643-651, ago. 2020. tab, graf
Article in Spanish | IBECS | ID: ibc-198250

ABSTRACT

INTRODUCCIÓN Y OBJETIVOS: La reparación de la válvula mitral transcatéter (RVMT) con el sistema MitraClip es un tratamiento para los pacientes con insuficiencia mitral (IM) grave de alto riesgo quirúrgico. El objetivo principal fue analizar los resultados del RVMT en pacientes con IM grave, según la etiología. MÉTODOS: Estudio observacional, prospectivo y multicéntrico con inclusión de pacientes consecutivos. El objetivo primario fue el combinado de mortalidad por todas las causas y reingresos hospitalarios por insuficiencia cardiaca al año. Se compararon las características clínicas y del procedimiento y los eventos para cada grupo de IM. Se realizó un análisis multivariable para determinar las variables asociadas con el objetivo primario. RESULTADOS: Se incluyó a 558 pacientes; 364 (65,2%) tenían etiología funcional; 111 (19,9%), degenerativa, y 83 (14,9%), mixta. La media de edad fue 72,8±11,1 años y eran varones el 70,3%. Respecto al objetivo primario, hubo 95 (17%) eventos en toda la serie. No hubo diferencias significativas entre los 3 grupos en el número de eventos del objetivo primario: 11 (11,3%) en la IM degenerativa, 71 (21,3%) en la funcional y 13 (18,1%) en la mixta (p = 0,101). Los predictores independientes fueron la clase funcional (p = 0,029), la revascularización quirúrgica previa (p = 0,031), el EuroSCORE II (p = 0,003), la diabetes mellitus (p = 0,037) y la fracción de eyección del ventrículo izquierdo (p = 0,015). CONCLUSIONES: Este trabajo confirma con datos de la práctica clínica la seguridad y la eficacia de la RVMT independientemente de la etiología de la IM y se documentan los principales factores asociados con el pronóstico durante el primer año de seguimiento


INTRODUCTION AND OBJECTIVES: Transcatheter mitral valve repair (TMVR) with MitraClip is a therapeutic option for high surgical risk patients with severe mitral regurgitation (MR). The main objective of this study was to analyze differences in outcomes in patients with severe MR according to the cause of MR. METHODS: Observational, multicenter, and prospective study with consecutive patient inclusion. The primary endpoint was the combination of all-cause mortality and new readmissions due to heart failure after 1 year. We compared clinical and procedural characteristics and the event rate for each MR group. We performed a multivariate analysis to identify predictive variables for the primary endpoint. RESULTS: A total of 558 patients were included: 364 (65.2%) with functional etiology, 111 (19.9%) degenerative and 83 (14.9%) mixed. The mean age was 72.8±11.1 years and 70.3% of the sample were men. There were 95 (17%) events in the overall sample. No significant differences were found in the 3 groups in the number of primary outcome events: 11 (11.3%) in degenerative MR, 71 (21.3%) in functional MR, and 13 (18.1%) in mixed MR (P=.101). Independent predictors were functional class (P=.029), previous surgical revascularization (P=.031), EuroSCORE II (P=.003), diabetes mellitus (P=.037), and left ventricular ejection fraction (P=.015). CONCLUSIONS: This study confirms the safety and efficacy of TMVR with MitraClip irrespective of MR etiology in real-life data and shows the main factors related to prognosis during the first year of follow up


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Mitral Valve Insufficiency/surgery , Heart Valve Prosthesis Implantation/methods , Heart-Assist Devices , Ventricular Dysfunction, Left/classification , Treatment Outcome , Patient Safety , Severity of Illness Index , Prospective Studies , Cardiac Catheterization/methods , Spain/epidemiology
14.
J Clin Med ; 9(6)2020 Jun 09.
Article in English | MEDLINE | ID: mdl-32526978

ABSTRACT

BACKGROUND: Transcatheter mitral valve repair (TMVR) could improve survival in functional mitral regurgitation (FMR), but it is necessary to consider the influence of left ventricular ejection fraction (LVEF). Therefore, we compare the outcomes after TMVR with Mitraclip® between two groups according to LVEF. METHODS: In an observational registry study, we compared the outcomes in patients with FMR who underwent TMVR with and without LVEF <30%. The primary endpoint was the combined one-year all-cause mortality and unplanned hospital readmissions due to HF. The secondary end-points were New York Heart Association (NYHA) functional class and mitral regurgitation (MR) severity. Propensity-score matching was used to create two groups with the same baseline characteristics, except for baseline LVEF. RESULTS: Among 535 FMR eligible patients, 144 patients with LVEF <30% (group 1) and 144 with LVEF >30% (group 2) had similar propensity scores and were included in the analyses. The primary study endpoint was significantlly higher in group 1 (33.3% vs. 9.4%, p = 0.002). There was a maintained improvement in secondary endpoints without significant differences among groups. CONCLUSION: FMR patients with LVEF <30% treated with MitraClip® had higher mortality and readmissions than patients with LVEF ≥30% treated with the same device. However, both groups improved the NYHA functional class and MR severity.

15.
Rev. esp. cardiol. (Ed. impr.) ; 73(5): 383-392, mayo 2020. tab, graf
Article in Spanish | IBECS | ID: ibc-194546

ABSTRACT

INTRODUCCIÓN Y OBJETIVOS: El objetivo es analizar la incidencia, los predictores y el impacto pronóstico de la insuficiencia cardiaca (IC) aguda tras el implante percutáneo de una válvula aórtica (TAVI) con una prótesis autoexpandible. MÉTODOS: Desde 2008, se incluye prospectivamente en nuestro registro de TAVI a todos los pacientes sometidos a TAVI en nuestro centro. Se analizan los factores pronósticos determinantes de IC aguda, y la relación con la mortalidad mediante modelos de regresión de Cox. RESULTADOS: Se sometieron a TAVI 399 pacientes, con una media de edad de 82,4 ± 5,8 años, de los que 213 (53,4%) eran mujeres. Durante el seguimiento (27,0 ± 24,1 meses), el 29,8% de los pacientes (n = 119) ingresaron en el hospital con el diagnóstico de IC aguda, lo que representa una incidencia anual del 13,2% (IC95%, 11,1-15,8%). Al final del seguimiento, habían fallecido 150 pacientes (37,59%). En el grupo de IC aguda se evidenció una tasa de mortalidad significativamente mayor (el 52,1 frente al 31,4%; HR = 1,84; IC95%, 1,14-2,97; p < 0,012). El diagnóstico previo de IC (p = 0,019) y la puntuación de la Society of Thoracic Surgeons (p = 0,004) se identificaron como predictores independientes de IC aguda tras el TAVI. Además, el índice de riesgo nutricional y la enfermedad pulmonar obstructiva crónica son los principales factores que ensombrecen el pronóstico dentro del grupo de IC aguda. CONCLUSIONES: El TAVI se asocia con una alta incidencia de eventos de IC aguda, lo que supone un gran impacto en la mortalidad. La IC aguda previa al implante y la puntuación de la Society of Thoracic Surgeons fueron los únicos predictores de IC aguda hallados. Un índice de riesgo nutricional bajo y la enfermedad pulmonar obstructiva crónica son potentes determinantes de mortalidad en el grupo de IC aguda


INTRODUCTION AND OBJECTIVES: The purpose of this analysis was to assess the incidence, predictors and prognostic impact of acute heart failure (AHF) after transcatheter aortic valve implantation (TAVI) using a self-expanding prosthesis. METHODS: From November 2008 to June 2017, all consecutive patients undergoing TAVI in our center were prospectively included in our TAVI registry. The predictive effect of AHF on all-cause mortality following the TAVI procedure was analyzed using Cox regression models. RESULTS: A total of 399 patients underwent TAVI with a mean age of 82.4 ± 5.8 years, of which 213 (53.4%) were women. During follow-up (27.0 ± 24.1 months), 29.8% (n = 119) were admitted due to AHF, which represents a cumulative incidence function of 13.2% (95%CI, 11.1%-15.8%). At the end of follow-up, 150 patients (37.59%) had died. Those who developed AHF showed a significantly higher mortality rate (52.1% vs 31.4%; HR, 1.84; 95%CI, 1.14-2.97; P = .012). Independent predictors of AHF after TAVI were a past history of heart failure (P = .019) and high Society of Thoracic Surgeons score (P = .004). We found that nutritional risk index and chronic obstructive pulmonary disease were strongly correlated with outcomes in the AHF group. CONCLUSIONS: TAVI was associated with a high incidence of clinical AHF. Those who developed AHF had higher mortality. Pre-TAVI AHF and high Society of Thoracic Surgeons score were the only independent predictors of AHF in our cohort. A low nutritional risk index and chronic obstructive pulmonary disease were independent markers of mortality in the AHF group


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Heart Failure/surgery , Transcatheter Aortic Valve Replacement , Severity of Illness Index , Heart Failure/mortality , Follow-Up Studies , Prospective Studies , Risk Factors , Prognosis
16.
Rev Esp Cardiol (Engl Ed) ; 73(5): 383-392, 2020 May.
Article in English, Spanish | MEDLINE | ID: mdl-31501029

ABSTRACT

INTRODUCTION AND OBJECTIVES: The purpose of this analysis was to assess the incidence, predictors and prognostic impact of acute heart failure (AHF) after transcatheter aortic valve implantation (TAVI) using a self-expanding prosthesis. METHODS: From November 2008 to June 2017, all consecutive patients undergoing TAVI in our center were prospectively included in our TAVI registry. The predictive effect of AHF on all-cause mortality following the TAVI procedure was analyzed using Cox regression models. RESULTS: A total of 399 patients underwent TAVI with a mean age of 82.4 ± 5.8 years, of which 213 (53.4%) were women. During follow-up (27.0 ± 24.1 months), 29.8% (n = 119) were admitted due to AHF, which represents a cumulative incidence function of 13.2% (95%CI, 11.1%-15.8%). At the end of follow-up, 150 patients (37.59%) had died. Those who developed AHF showed a significantly higher mortality rate (52.1% vs 31.4%; HR, 1.84; 95%; CI, 1.14-2.97; P = .012). Independent predictors of AHF after TAVI were a past history of heart failure (P = .019) and high Society of Thoracic Surgeons score (P = .004). We found that nutritional risk index and chronic obstructive pulmonary disease were strongly correlated with outcomes in the AHF group. CONCLUSIONS: TAVI was associated with a high incidence of clinical AHF. Those who developed AHF had higher mortality. Pre-TAVI AHF and high Society of Thoracic Surgeons score were the only independent predictors of AHF in our cohort. A low nutritional risk index and chronic obstructive pulmonary disease were independent markers of mortality in the AHF group.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Failure/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Female , Heart Failure/epidemiology , Humans , Male , Prospective Studies , Risk Factors , Treatment Outcome
17.
Rev Esp Cardiol (Engl Ed) ; 73(8): 643-651, 2020 Aug.
Article in English, Spanish | MEDLINE | ID: mdl-31732437

ABSTRACT

INTRODUCTION AND OBJECTIVES: Transcatheter mitral valve repair (TMVR) with MitraClip is a therapeutic option for high surgical risk patients with severe mitral regurgitation (MR). The main objective of this study was to analyze differences in outcomes in patients with severe MR according to the cause of MR. METHODS: Observational, multicenter, and prospective study with consecutive patient inclusion. The primary endpoint was the combination of all-cause mortality and new readmissions due to heart failure after 1 year. We compared clinical and procedural characteristics and the event rate for each MR group. We performed a multivariate analysis to identify predictive variables for the primary endpoint. RESULTS: A total of 558 patients were included: 364 (65.2%) with functional etiology, 111 (19.9%) degenerative and 83 (14.9%) mixed. The mean age was 72.8±11.1 years and 70.3% of the sample were men. There were 95 (17%) events in the overall sample. No significant differences were found in the 3 groups in the number of primary outcome events: 11 (11.3%) in degenerative MR, 71 (21.3%) in functional MR, and 13 (18.1%) in mixed MR (P=.101). Independent predictors were functional class (P=.029), previous surgical revascularization (P=.031), EuroSCORE II (P=.003), diabetes mellitus (P=.037), and left ventricular ejection fraction (P=.015). CONCLUSIONS: This study confirms the safety and efficacy of TMVR with MitraClip irrespective of MR etiology in real-life data and shows the main factors related to prognosis during the first year of follow up.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aged , Aged, 80 and over , Cardiac Catheterization , Female , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/epidemiology , Mitral Valve Insufficiency/surgery , Prospective Studies , Registries , Stroke Volume , Treatment Outcome , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL
...