1.
J Neurol ; 270(8): 4049-4059, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37162578

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) detection and treatment are key elements to reduce recurrence risk in cryptogenic stroke (CS) with underlying arrhythmia. The purpose of the present study was to assess the predictors of AF in CS and the utility of existing AF-predicting scores in The Nordic Atrial Fibrillation and Stroke (NOR-FIB) Study. METHOD: The NOR-FIB study was an international prospective observational multicenter study designed to detect and quantify AF in CS and cryptogenic transient ischaemic attack (TIA) patients monitored by the insertable cardiac monitor (ICM), and to identify AF-predicting biomarkers. The utility of the following AF-predicting scores was tested: AS5F, Brown ESUS-AF, CHA2DS2-VASc, CHASE-LESS, HATCH, HAVOC, STAF and SURF. RESULTS: In univariate analyses increasing age, hypertension, left ventricle hypertrophy, dyslipidaemia, antiarrhythmic drugs usage, valvular heart disease, and neuroimaging findings of stroke due to intracranial vessel occlusions and previous ischemic lesions were associated with a higher likelihood of detected AF. In multivariate analysis, age was the only independent predictor of AF. All the AF-predicting scores showed significantly higher score levels for AF than non-AF patients. The STAF and the SURF scores provided the highest sensitivity and negative predictive values, while the AS5F and SURF reached an area under the receiver operating curve (AUC) > 0.7. CONCLUSION: Clinical risk scores may guide a personalized evaluation approach in CS patients. Increasing awareness of the usage of available AF-predicting scores may optimize the arrhythmia detection pathway in stroke units.


Subject(s)
Atrial Fibrillation , Ischemic Attack, Transient , Ischemic Stroke , Stroke , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Stroke/diagnosis , Stroke/diagnostic imaging , Ischemic Attack, Transient/complications , Ischemic Attack, Transient/diagnosis , Risk Factors , Ischemic Stroke/complications
2.
Eur Stroke J ; 8(1): 148-156, 2023 03.
Article in English | MEDLINE | ID: mdl-37021182

ABSTRACT

Introduction: Secondary stroke prevention depends on proper identification of the underlying etiology and initiation of optimal treatment after the index event. The aim of the NOR-FIB study was to detect and quantify underlying atrial fibrillation (AF) in patients with cryptogenic stroke (CS) or transient ischaemic attack (TIA) using insertable cardiac monitor (ICM), to optimise secondary prevention, and to test the feasibility of ICM usage for stroke physicians. Patients and methods: Prospective observational international multicenter real-life study of CS and TIA patients monitored for 12 months with ICM (Reveal LINQ) for AF detection. Results: ICM insertion was performed in 91.5% by stroke physicians, within median 9 days after index event. Paroxysmal AF was diagnosed in 74 out of 259 patients (28.6%), detected early after ICM insertion (mean 48 ± 52 days) in 86.5% of patients. AF patients were older (72.6 vs 62.2; p < 0.001), had higher pre-stroke CHA2DS2-VASc score (median 3 vs 2; p < 0.001) and admission NIHSS (median 2 vs 1; p = 0.001); and more often hypertension (p = 0.045) and dyslipidaemia (p = 0.005) than non-AF patients. The arrhythmia was recurrent in 91.9% and asymptomatic in 93.2%. At 12-month follow-up anticoagulants usage was 97.3%. Discussion and conclusions: ICM was an effective tool for diagnosing underlying AF, capturing AF in 29% of the CS and TIA patients. AF was asymptomatic in most cases and would mainly have gone undiagnosed without ICM. The insertion and use of ICM was feasible for stroke physicians in stroke units.


Subject(s)
Atrial Fibrillation , Ischemic Attack, Transient , Ischemic Stroke , Stroke , Humans , Atrial Fibrillation/complications , Ischemic Attack, Transient/complications , Electrocardiography, Ambulatory/adverse effects , Stroke/diagnosis , Ischemic Stroke/complications
3.
BMC Neurol ; 23(1): 115, 2023 Mar 21.
Article in English | MEDLINE | ID: mdl-36944929

ABSTRACT

BACKGROUND: Cryptogenic stroke is a heterogeneous condition, with a wide spectrum of possible underlying causes for which the optimal secondary prevention may differ substantially. Attempting a correct etiological diagnosis to reduce the stroke recurrence should be the fundamental goal of modern stroke management. METHODS: Prospective observational international multicenter study of cryptogenic stroke and cryptogenic transient ischemic attack (TIA) patients clinically monitored for 12 months to assign the underlying etiology. For atrial fibrillation (AF) detection continuous cardiac rhythm monitoring with insertable cardiac monitor (Reveal LINQ, Medtronic) was performed. The 12-month follow-up data for 250 of 259 initially included NOR-FIB patients were available for analysis. RESULTS: After 12 months follow-up probable stroke causes were revealed in 43% patients, while 57% still remained cryptogenic. AF and atrial flutter was most prevalent (29%). In 14% patients other possible causes were revealed (small vessel disease, large-artery atherosclerosis, hypercoagulable states, other cardioembolism). Patients remaining cryptogenic were younger (p < 0.001), had lower CHA2DS2-VASc score (p < 0.001) on admission, and lower NIHSS score (p = 0.031) and mRS (p = 0.016) at discharge. Smoking was more prevalent in patients that were still cryptogenic (p = 0.014), while dyslipidaemia was less prevalent (p = 0.044). Stroke recurrence rate was higher in the cryptogenic group compared to the group where the etiology was revealed, 7.7% vs. 2.8%, (p = 0.091). CONCLUSION: Cryptogenic stroke often indicates the inability to identify the cause in the acute phase and should be considered as a working diagnosis until efforts of diagnostic work up succeed in identifying a specific underlying etiology. Timeframe of 6-12-month follow-up may be considered as optimal. TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT02937077, EudraCT 2018-002298-23.


Subject(s)
Atrial Fibrillation , Ischemic Attack, Transient , Ischemic Stroke , Stroke , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/epidemiology , Ischemic Attack, Transient/complications , Ischemic Attack, Transient/epidemiology , Ischemic Attack, Transient/diagnosis , Stroke/epidemiology , Stroke/etiology , Stroke/diagnosis , Ischemic Stroke/complications , Causality , Electrocardiography, Ambulatory/adverse effects
4.
AJNR Am J Neuroradiol ; 38(7): 1356-1361, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28495947

ABSTRACT

BACKGROUND AND PURPOSE: The Embolus Retriever with Interlinked Cages (ERIC) device is a novel stent retriever for mechanical thrombectomy. It consists of interlinked cages and could improve procedural benchmarks and clinical outcome compared with classic stent retrievers. This study compares the rates of recanalization, favorable clinical outcome, procedural adverse events, and benchmarks between the ERIC device and classic stent retrievers. MATERIALS AND METHODS: From 545 patients treated with thrombectomy between 2012 and 2015, 316 patients were included. The mean age was 69 ±13 years, the mean baseline NIHSS score was 17 ± 5, and 174 (55%) were men. The ERIC was used as the primary thrombectomy device in 59 (19%) patients. In a propensity score matched analysis including the NIHSS score, clot location, delay to groin puncture, neurointerventionalist, and anesthetic management, 57 matched pairs were identified. RESULTS: Patients treated with the ERIC device compared with classic stent retrievers showed equal rates of recanalization (86% versus 81%, P = .61), equal favorable 3-month clinical outcome (mRS 0-2: 46% versus 40%, P = .71), and procedural adverse events (28% versus 30%, P = 1.00). However, in patients treated with the ERIC device, thrombectomy procedures were less time-consuming (67 versus 98 minutes, P = .009) and a rescue device was needed less often (18% versus 39%, P = .02) compared with classic stent retrievers. CONCLUSIONS: Mechanical thrombectomy with the ERIC device is effective and safe. Rates of favorable procedural and clinical outcomes are at least as good as those with classic stent retrievers. Of note, the ERIC device might be time-saving and decrease the need for rescue devices. These promising results call for replication in larger prospective clinical trials.


Subject(s)
Brain Ischemia/surgery , Intracranial Embolism/surgery , Stroke/surgery , Surgical Instruments , Thrombectomy/methods , Adult , Aged , Aged, 80 and over , Anesthesia , Case-Control Studies , Device Removal , Female , Groin , Humans , Male , Middle Aged , Postoperative Care , Propensity Score , Punctures , Retrospective Studies , Stents , Surgical Instruments/adverse effects , Thrombectomy/adverse effects , Treatment Outcome