Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 114
Filter
3.
Thorac Cardiovasc Surg ; 72(2): 134-141, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37506731

ABSTRACT

BACKGROUND: Computational fluid dynamics (CFD) simulations model blood flow in aortic pathologies. The aim of our study was to understand the local hemodynamic environment at the site of rupture in distal stent graft-induced new entry (dSINE) after frozen elephant trunk with a clinically time efficient steady-flow simulation versus transient simulations. METHODS: Steady-state simulations were performed for dSINE, prior and after its development and prior to aortic rupture. To account for potential turbulences due geometric changes at the dSINE location, Reynolds-averaged Navier-Stokes equations with the realizable k-ε model for turbulences were applied. Transient simulations were performed for comparison. Hemodynamic parameters were assessed at various locations of the aorta. RESULTS: Post-dSINE, jet-like flow due to luminal narrowing was observed which increased prior to rupture and resulted in focal neighbored regions of high and low wall shear stress (WSS). Prior to rupture, aortic diameter at the rupture site increased lowering WSS at the entire aortic circumference. Concurrently, WSS and turbulence increased locally above the entry tear at the inner aortic curvature. Turbulent kinetic energy and WSS elevation in the downstream aorta demonstrated enhanced stress on the native aorta. Results of steady-state simulations were in good qualitative agreement with transient simulations. CONCLUSION: Steady-flow CFD simulations feasible at clinical time scales prior to aortic rupture reveal a hostile hemodynamic environment at the dSINE rupture site in agreement with lengthy transient simulations. Consequently, our developed approach may be of value in treatment planning where a fast assessment of the local hemodynamic environment is essential.


Subject(s)
Aortic Rupture , Humans , Aortic Rupture/diagnostic imaging , Aortic Rupture/etiology , Aortic Rupture/surgery , Models, Cardiovascular , Treatment Outcome , Hemodynamics , Computer Simulation , Stents , Stress, Mechanical , Hydrodynamics
4.
Front Cardiovasc Med ; 10: 1303816, 2023.
Article in English | MEDLINE | ID: mdl-38155987

ABSTRACT

Introduction: Recent reports have questioned the blood impermeability of the novel frozen elephant trunk (FET) device E-vita Open NEO© (EO-NEO). Therefore, standardized in vitro bleeding tests using porcine heparinized blood were performed, as well as stress testing on the blood tightness of the collar suture line, to investigate this observation. Material and methods: EO-NEO prostheses were examined in vitro for blood permeability in three test series. Initially, antegrade perfusion with heparinized porcine blood [activated clotting time (ACT) of 500 s, with a 60 min duration] was performed, followed by ante/retrograde testing via the EO-NEO side port. Testing of the collar suture line under a tension of 10 Newton (N) within a suspension device (blood pressure 120 mmHg, ACT of 560 s, 1 min duration) was carried out with the suture material force fiber white (FFWs) yarn, using standard fixation (5 stitches/cm), FFWh yarn in hemostatic fixation (15 stitches/cm), and flow weave yarn (FWYh). Results: Blood permeability testing of EO-NEO through the prosthetic lumen or via the side port demonstrated minor leakage without statistical difference between the standard and hemostatic suture lines or suture materials used, or positioning on the crimped or tapered portion (p > 0.05). The specific collar anastomosis testing demonstrated leakage volumes of 140 ml/min for FFWs vs. 16 ml/min for FFWh (p = 0.02), vs. 9 ml/min with the FWYh (p = 0.01). Conclusion: Different blood leakage tests showed minimal oozing and no difference in blood loss through the fabric and different collar suture lines, but unphysiological pressurized retrograde perfusion of the collar region showed significantly less leakage using FWYh and FFWh, prompting production modification of EO-NEO. Clinical results confirmed low blood loss using this novel FET device.

5.
Article in English | MEDLINE | ID: mdl-38011667

ABSTRACT

OBJECTIVES: The ideal treatment for aneuryms of aberrant left subclavian arteries with Kommerell's diverticulum arising from right aortic arches remains open. METHODS: Between January 2015 and December 2020, 5 patients with aneurysms from a right-sided aortic arch with aberrant left subclavian artery and Kommerell's diverticulum underwent repair by using the frozen elephant trunk technique in 3 aortic centres. Patients' characteristics were retrospectively reviewed and the surgical procedure and outcomes are presented. RESULTS: The median age of the 2 male and 3 female patients was 59 (range from 49 to 63) years. The median operative times were as follows: surgery 405 min (range from 335 to 534), cardiopulmonary bypass time 244 min (range from 208 to 280) and aortic clamp time 120 min (from 71 to 184). The mean core temperature was 25.94°C (from 24 to 28). The intensive care unit stay was 4 days (range from 1 to 8) and the in-hospital stay 21 days (from 16 to 34). All patients were discharged and we observed no stroke or spinal cord ischaemia postoperatively. During the median follow-up time of 1003 days (range from 450 to 2306), 3 patients required subsequent thoracic endovascular distal stent graft extension. CONCLUSIONS: The frozen elephant trunk technique is a good treatment option for patients with aneuryms of an aberrant left subclavian artery with Kommerell's diverticulum arising from right aortic arches. Secondary stent graft extension is a frequently needed component of the treatment concept.

6.
J Thorac Dis ; 15(2): 281-290, 2023 Feb 28.
Article in English | MEDLINE | ID: mdl-36910066

ABSTRACT

Background: Distal stent graft induced new entry (dSINE) is an emerging complication after frozen elephant trunk (FET) procedure. The aim of this computational fluid dynamics (CFD) study was to investigate the role of wall shear stress (WSS) after the development of dSINE based on hemodynamic changes. Methods: Aortic diameter and WSS of five patients who developed a dSINE after FET procedure were retrospectively analyzed before and after the occurrence of dSINE. Patient-specific 3-dimentional surface models of the aortic lumen were reconstructed from computed tomography angiographic datasets (pre dSINE: n=5, dSINE: n=5) to perform steady-state CFD simulations with laminar blood flow and zero pressure outlet conditions. WSS was calculated at the level of the stent graft (SG), the landing zone of the SG and at a location further distal to the SG, as well as on the outer and inner curvature of the aorta from SG center to its distal end. Results: Post dSINE occurrence, median WSS increased significantly from 0.87 [interquartile range (IQR): 0.83-1.03] to 1.55 (IQR: 1.09-2.70) Pa, (P=0.043) within the SG and from 1.22 (IQR: 0.81-1.44) to 1.76 (IQR: 1.55-3.60) Pa, (P=0.043) at the landing zone of the SG. A non-significant increase from 1.22 (IQR: 0.59-3.50) to 2.58 (IQR: 1.16-3.78) Pa, (P=0.686) further downstream was observed. WSS at the outer curvature of the SG was significantly higher compared to WSS at the inner curvature for dSINE. Conclusions: Adverse hemodynamic conditions in the form of elevated WSS consist inside and at the distal end of the SG as well as at the outer curvature of the aorta, which may contribute to weakening of the aortic wall. These new findings emphasize the relevance and potential of WSS in dSINE for additional adverse events, such as aortic rupture. Further prospective studies are warranted to explore if the combination of clinical parameters with WSS might be useful to decide which patients require an urgent reintervention in terms of a SG extension.

7.
Life (Basel) ; 13(3)2023 Mar 22.
Article in English | MEDLINE | ID: mdl-36984006

ABSTRACT

Chronic type B aortic dissection (cTBAD) is a rare but challenging condition that requires individual treatment strategies. Especially the long-term therapy impacts prognosis. In this single-center retrospective study, we evaluated patients with cTBAD in our vascular outpatient clinic over 10 years. Follow-up consultations included contrast-enhanced, electrocardiogram-triggered, high-resolution CT angiography (CTA) covering the entire aorta. Evaluated characteristics went beyond demographic characteristics combining the treatment approach and the timing and occurrence of potential complications. We analyzed 133 patients in total (n = 92, 69.2% male) with cTBAD with a mean follow-up of 67.7 months. Most of them underwent invasive treatment (n = 102, 76.7%), the majority received thoracic endovascular aortic repair (TEVAR) (n = 82, 61.7%). A total of 80 patients (60.2%) had major complications, whereas over a third was free of complications even after 5 years. Most common complications were progress of dissection and endoleaks, aneurysms of true (TL) and false lumen (FL) were more common in the later time periods. The treatment of cTBAD in terms of timing, therapy approach, and complications is still challenging for the entire aortic team. Nevertheless, the early recognition of complications permits promising treatment options and highlights the importance of frequent follow-up examinations especially within the first years.

8.
Eur J Cardiothorac Surg ; 63(5)2023 05 02.
Article in English | MEDLINE | ID: mdl-36951534

ABSTRACT

OBJECTIVES: The prevalence and aetiology of acute aortic dissection type A (AADA) in patients ≤30 years is unknown. The aims of this clinical study were to determine the prevalence and potential aetiology of AADA in surgically treated patients ≤30 years and to evaluate the respective postoperative outcomes in this selective group of patients in a large multicentre study. METHODS: Retrospective data collection was performed at 16 participating international aortic institutions. All patients ≤30 years at the time of dissection onset were included. The postoperative results were analysed with regard to connective tissue disease (CTD). RESULTS: The overall prevalence of AADA ≤30 years was 1.8% (139 out of 7914 patients), including 51 (36.7%) patients who were retrospectively diagnosed with CTD. Cumulative postoperative mortality was 8.6%, 2.2% and 1.4%. Actuarial survival was 80% at 10 years postoperatively. Non-CTD patients (n = 88) had a significantly higher incidence of arterial hypertension (46.6% vs 9.8%; P < 0.001) while AADA affected the aortic root (P < 0.001) and arch (P = 0.029) significantly more often in the CTD group. A positive family history of aortic disease was present in 9.4% of the study cohort (n = 13). CONCLUSIONS: The prevalence of AADA in surgically treated patients ≤30 years is <2% with CTD and arterial hypertension as the 2 most prevalent triggers of AADA. Open surgery may be performed with good early results and excellent mid- to long-term outcomes.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Humans , Young Adult , Adolescent , Retrospective Studies , Treatment Outcome , Aortic Dissection/epidemiology , Aortic Dissection/surgery , Aorta/surgery , Demography , Aortic Aneurysm, Thoracic/surgery
9.
BMC Cardiovasc Disord ; 22(1): 333, 2022 07 26.
Article in English | MEDLINE | ID: mdl-35883019

ABSTRACT

BACKGROUND: Endovascular treatment of patients with Marfan syndrome (MFS) is not recommended. Hybrid procedures such as frozen elephant trunk (FET), which combines stent-graft deployment with an integrated non-stented fabric graft for proximal grafting and suturing, have not been previously evaluated. The aim of this study was to assess the safety and feasibility of FET operation in patients with MFS. METHODS: Patients enrolled in the International E-vita Open Registry (IEOR) who underwent FET procedure between January 2001 and February 2020 meeting Ghent criteria for MFS were included in the study. Early and midterm results were retrospectively analyzed. Preoperative, postoperative and follow-up computed tomography angiography scans were analysed. RESULTS: We analyzed 37 patients [mean age 38 ± 11 years, 65% men]. Acute or chronic aortic dissection was present in 35 (95%) patients (14 and 21 patients respectively). Two (5%) patients had an aneurysm without dissection. Malperfusion syndrome was present in 4 patients. Twenty-nine (78%) patients had history of aortic surgical interventions. The 30-day and in-hospital mortality amounted to 8 and 14% respectively. False lumen exclusion was present in 73% in stented segment in last postoperative CT. The overall 5-year survival was 71% and freedom from reintervention downstream was 58% at 5 years. Of the nine patients who required reintervention for distal aortic disease, one patient died. CONCLUSIONS: FET operation for patients with MFS can be performed with acceptable mortality and morbidity. In long-term follow-up no reinterventions on the aortic arch were required. FET allows for easier second stage operations providing platform for surgical and endovascular reinterventions.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Marfan Syndrome , Adult , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Female , Humans , Male , Marfan Syndrome/complications , Marfan Syndrome/diagnosis , Marfan Syndrome/surgery , Middle Aged , Retrospective Studies , Stents , Treatment Outcome
11.
Ann Vasc Surg ; 84: 211-217, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35248740

ABSTRACT

BACKGROUND: The ever-changing landscape of aortic arch surgery necessitates a constant update on the available devices and technologies for the contemporary management of complex aortic diseases. The E-Vita OPEN NEO hybrid stent graft system offers a unique approach for aortic arch replacement with the frozen elephant trunk technique. In contrast to its predecessors and other commercially available devices, it fits to each individual patient's needs by allowing for more proximal graft anastomosis. We sought to present our initial experience with the novel E-Vita OPEN NEO hybrid stent graft system focusing on its description, optimal graft selection, operative technique, and results in a clinical setting. METHODS: We prospectively collected data on all patients in whom the E-Vita OPEN NEO device was used between October 2020 and May 2021. The primary outcome was perioperative or with 30-day mortality. Secondary outcomes were the incidence of neurologic complications (stroke and spinal cord ischemia) and endoleak on a postoperative computed tomography angiography. RESULTS: During the study period, six patients received the novel hybrid stent device. The mean patient age was 59.3 ± 13.3 years and 83% were male. Two patients were operated on an emergent setting due to acute Stanford type A aortic dissection and there were two reoperations in patients with a history of previous repaired type A dissection. There was no perioperative or 30-day mortality and none of the patients exhibited adverse neurologic events. Two patients required completion thoracic endovascular repair due to type Ib endoleak. One patient died after a prolonged stay in the intensive care unit due to pneumonia and multiorgan failure. CONCLUSIONS: This novel device adapts to each patient's characteristics and offers a curative option for acute and chronic aortic arch and descending aortic conditions such as aneurysmal disease and aortic dissection. In addition, it offers an excellent landing station for potential endovascular therapies and allows for complete aortic remodeling.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Diseases , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aged , Aortic Dissection/diagnostic imaging , Aortic Dissection/etiology , Aortic Dissection/surgery , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/etiology , Aortic Aneurysm, Thoracic/surgery , Aortic Diseases/surgery , Blood Vessel Prosthesis , Endoleak/etiology , Female , Humans , Male , Middle Aged , Stents , Treatment Outcome
12.
J Thorac Cardiovasc Surg ; 163(2): 568-574.e1, 2022 Feb.
Article in English | MEDLINE | ID: mdl-32653283

ABSTRACT

OBJECTIVE: Acute type I aortic dissection (AAD) represents a surgical emergency with time-dependent evolving complications. Frozen elephant trunk (FET) enables false lumen exclusion downstream but is still debated in AAD due to its greater dimension of surgery. To combine the benefits of fast proximal repair with the FET benefits, a 3-zone hybrid graft was developed consisting of an ascending polyester portion, an arch noncovered stent, and a descending stent graft. Mid-term results of this new technique are presented. METHODS: A total of 6 patients (age mean 69 years) with type I AAD in critical status (Penn classification B n = 5, BC n = 1) were operated between July 2016 and April 2018 using the 3-zone hybrid graft. The device was implanted on the basis of strict compassionate use. Operations were performed under distal hypothermic circulatory arrest and selective antegrade cerebral perfusion (SACP). RESULTS: Operative mortality was 17% (n = 1). Mean crossclamp and SACP time were 92 and 34 minutes, respectively, but came down in the last 2 cases to 75/65 crossclamp and 23/24 SACP minutes each. During follow up, mean 19 ± 12 months, one endovascular extension downstream was performed. Imaging control demonstrated no anastomotic-related proximal entry and no true lumen collapse downstream. CONCLUSIONS: The goal to achieve fast and reliable repair of complicated type I AAD down to midthoracic level seems to be achievable. Noncovered stenting of the head vessel's origin does not cause stenosis or obstruction. A multicenter studying of this concept is next.


Subject(s)
Aortic Aneurysm/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Acute Disease , Adult , Aged , Aortic Dissection/diagnostic imaging , Aortic Dissection/mortality , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Humans , Male , Prosthesis Design , Time Factors , Treatment Outcome
13.
J Am Heart Assoc ; 10(18): e021182, 2021 09 21.
Article in English | MEDLINE | ID: mdl-34514809

ABSTRACT

Background Coronary artery bypass grafting has remained an important treatment option for acute coronary syndromes, particularly in patients (1) with ongoing ischemia and large areas of jeopardized myocardium, if percutaneous coronary intervention (PCI) cannot be performed; (2) following successful PCI of the culprit lesion with further indication for coronary artery bypass grafting; and (3) where PCI is incomplete, not sufficient, or failed. Methods and Results We aimed to analyze coronary artery bypass grafting outcome following prior PCI in acute coronary syndromes from the North-Rhine-Westphalia surgical myocardial infarction registry comprising 2616 patients. Primary end points were in-hospital all-cause mortality and major adverse cardio-cerebral event. Patients were 68±11 years of age, had 3-vessel and left main-stem disease in 80.4% and 45.3%, presenting a logistic EuroSCORE of 15.1% in unstable angina, 20.3% in non-ST-segment-elevation myocardial infarction, and 23.5% in ST-segment-elevation myocardial infarction. A history of PCI was present in 36.2% and PCI was performed within 24 hours before surgery in 5.2% in unstable angina, 5.9% in non-ST-segment-elevation myocardial infarction, and 16.1% in ST-segment-elevation myocardial infarction. PCI failed in 5.3% in unstable angina, 6.8% in non-ST-segment-elevation myocardial infarction and 17.2% in ST-segment-elevation myocardial infarction, and 28.8% of patients presented with cardiogenic shock. In-hospital mortality without PCI was 7.4%, but increased to 8.7% with prior PCI >24 hours, 14.5% with prior PCI <24 hours, and 14.1% with failed PCI (P<0.003). The in-hospital major adverse cardio-cerebral event rate was 16.4% without PCI, but 17.4% with prior PCI >24 hours, 25.6% with prior PCI <24 hours, and 41.3% with failed PCI (P=0.014). Multivariable logistic regression analysis showed prior PCI (P=0.039), as well as failed PCI (P=0.001) to be predictors for in-hospital all-cause mortality and major adverse cardio-cerebral event. Conclusions In the current PCI era, immediately prior or failed PCI before coronary artery bypass grafting in acute coronary syndromes is associated with high perioperative risk, cardiogenic shock, and increased morbidity and mortality.


Subject(s)
Acute Coronary Syndrome , Coronary Artery Bypass , Myocardial Infarction , Percutaneous Coronary Intervention , Acute Coronary Syndrome/surgery , Angina, Unstable , Germany , Humans , Myocardial Infarction/epidemiology , Myocardial Infarction/therapy , Non-ST Elevated Myocardial Infarction , Percutaneous Coronary Intervention/adverse effects , Registries , ST Elevation Myocardial Infarction , Shock, Cardiogenic
14.
Eur J Cardiothorac Surg ; 61(1): 195-203, 2021 Dec 27.
Article in English | MEDLINE | ID: mdl-34378023

ABSTRACT

OBJECTIVES: To improve organ protection with the frozen elephant trunk (FET) procedure, a so-called four-sites perfusion in combination with proximalization for the distal aortic anastomosis was performed. The impact of these techniques on patient outcome is reported. METHODS: Between February 2005 and April 2020, a total of 357 patients underwent the FET procedure for acute (54%) or chronic (22%) aortic dissection or aneurysmal disease (24%). The level of the distal FET anastomosis was defined according to aortic arch zones 0-3. Patients were divided into 3 groups according to the intraoperative perfusion strategy: (i) selective antegrade cerebral perfusion (SACP) alone (N = 96, 2 sites); (ii) SACP plus left subclavian artery or distal aorta (N = 84, 3 sites) and (iii) SACP plus left subclavian artery plus distal aorta (N = 177, 4 sites). Early outcome was addressed by a composite end point: occurrence of either a disabling stroke, a disabling spinal cord injury, extracorporeal circulatory support, kidney dialysis or death within 90 days. RESULTS: Preoperative characteristics were similar among the groups. Surgery in group C was characterized by FET proximalization in arch zone ≤2, moderate hypothermia at 28°C and shorter periods of extracorporeal circulation, SACP, hypothermic circulatory arrest and cardioplegic arrest (P < 0.001, respectively). Occurrence of the composite end point was reduced in group C (P = 0.008). The combination of FET proximalization and four-sites perfusion was a protective factor for the composite outcome in multivariable analysis (P = 0.009). The 5-year survival was improved in patients who underwent FET proximalization in zone ≤2 (hazard ratio 0.7, 95% confidence interval 0.4-1.0; P = 0.036). CONCLUSIONS: FET proximalization in combination with four-sites perfusion has the potential to improve patient outcomes in terms of survival and major events. SUBJECT COLLECTION: 120; 161.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Aortic Dissection/surgery , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Humans , Perfusion , Retrospective Studies , Treatment Outcome
15.
Eur J Cardiothorac Surg ; 61(1): 142-149, 2021 Dec 27.
Article in English | MEDLINE | ID: mdl-34329387

ABSTRACT

OBJECTIVES: Our goal was to evaluate the extent of stent-graft (SG) elastic recoil in the descending aorta after the frozen elephant trunk procedure in acute (AAD) and chronic (CAD) aortic dissection as well as the impact of SG movement on distal stent graft-induced new entry (d-SINE). METHODS: We retrospectively analysed 149 (105 AAD, 44 CAD) of 259 aortic dissection patients after the frozen elephant trunk procedure between January 2005 and April 2019. Inclusion criteria were at least 1-year computed tomography angiography (CTA) aortic examinations during a follow-up time of 3.8 ± 2.7 years and absence of open or endovascular reintervention. Multiplanar reconstruction of CTA scans was used to define the SG vector position and movement in a virtual Cartesian coordinate system. The angle φ of vector movement and changes of aortic areas at the distal landing zone were analysed. RESULTS: The distal SG position changed over time in the cranial (10.06 ± 11.12 mm), dorsal (8.45 ± 11.12 mm) and lateral (4.96 ± 9.89 mm) directions (P < 0.001). The total change of φ (4.08 ± 7.03°) was greater in AAD than in CAD (P = 0.026). d-SINE was more common in CAD (P < 0.001) and was associated with the size of the aortic area, aortic area enlargement and continuous SG unfolding (P < 0.001). CONCLUSIONS: With the frozen elephant trunk technique, movement and change of SG orientation in the descending aorta were observed over time. Elastic recoil was greater in AAD than in CAD. The incidence of d-SINE was particularly dependent on the size of the aortic lumen and SG radial expansion and less on elastic recoil.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/methods , Humans , Retrospective Studies , Stents , Treatment Outcome
16.
Eur J Cardiothorac Surg ; 59(1): 65-73, 2021 01 04.
Article in English | MEDLINE | ID: mdl-33011773

ABSTRACT

Since its clinical implementation in the late nineties, thoracic endovascular aortic repair (TEVAR) has become the standard treatment of several acute and chronic diseases of the thoracic aorta. While TEVAR has been embraced by many, this disruptive technology has also stimulated the continuing evolution of open surgery, which became even more important as late TEVAR failures do need open surgical correction justifying the need to unite both treatment options under one umbrella. This fact shows the importance of-in analogy to the heart team-aortic centre formation and centralization of care, which stimulates continuing development and improves outcome . The next frontier to be explored is the most proximal component of the aorta-the aortic root, in particular in acute type A aortic dissection-which remains the main challenge for the years to come. The aim of this document is to provide the reader with a synopsis of current evidence regarding the use or non-use of TEVAR in acute and chronic thoracic aortic disease, to share latest recommendations for a modified terminology and for reporting standards and finally to provide a glimpse into future developments.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Diseases , Cardiology , Endovascular Procedures , Peripheral Vascular Diseases , Thoracic Surgery , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Diseases/surgery , Chronic Disease , Consensus , Humans , Treatment Outcome
19.
J Thorac Dis ; 12(10): 5639-5646, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33209396

ABSTRACT

BACKGROUND: This study aims to compare the operative and postoperative results of on-pump (ONCAB) and off-pump (OPCAB) coronary artery bypass surgery (CABG) for multi-vessel coronary revascularization (≥4 anastomoses). METHODS: From May 2018 to August 2019, a total of 120 patients (22.5% women, mean age 61.5±8.4 years) received either ONCAB (Group 1, n=60) or OPCAB (Group 2, n=60) for multi-vessel coronary artery disease (CAD). Preoperative left ventricular (LV) ejection fraction (EF) was 53.1%±8.4%. Median EuroSCORE II was 1.59 (interquartile range, 1.01-2.54). The median number of performed coronary anastomoses was 4 (interquartile range, 4-5), with equal distribution in both groups (P=0.4). All procedures were performed by highly experienced surgeons. The primary endpoints were overall survival at 30 days and freedom from severe adverse events (SAE), which included myocardial infarction (MI), coronary artery re-operation, and re-thoracotomy, caused by bleeding and stroke. RESULTS: The overall survival in both groups was 100% with no intraoperative OPCAB-to-on-pump conversion. The median procedure time was 169 min (interquartile range, 150-179 min) for Group 1 and 183 min (interquartile range, 169-205 min) for Group 2 (P<0.001). The overall freedom from SAE numbered 93.3% (98.3% vs. 88.3%, P=0.030). Postoperative MI rate was 2.5% (n=3) with no significant difference for either group (0 vs. 5.0%, P=0.100). One MI patient underwent a re-operation, and two other patients received a conservative treatment. A total of 2.5% (n=3) of patients underwent a re-thoracotomy on account of bleeding (0 vs. 5.0%, P=0.100); no anastomosis-related bleeding was detected. Blood transfusion was applied in 31.7% of patients (38.3% vs. 25.0%, P=0.090). A total of 1.7% of patients (1.7% vs. 1.7%, P=0.800) developed a stroke. Ventilation time, intensive care unit stay, and hospital stay were similar in both groups. CONCLUSIONS: ONCAB showed superior freedom from SAE and shorter procedure times when compared to OPCAB for multi-vessel coronary artery revascularization.

20.
J Cardiothorac Surg ; 15(1): 330, 2020 Nov 16.
Article in English | MEDLINE | ID: mdl-33198774

ABSTRACT

OBJECTIVES: Long-term data on isolated surgical tricuspid valve procedures is limited. Current guidelines on heart valve disease recommend valve repair over valve replacement. In this study we report our 12-year single-center experience with isolated surgical tricuspid valve repair in patients with various tricuspid valve pathologies. METHODS: Between May 2007 and December 2019, 26 consecutive patients underwent isolated tricuspid valve annuloplasty/repair for various indications. In 18 patients (69.2%) an open ring or band annuloplasty (26.9 and 42.3%, respectively) was performed, 5 patients (19.2%) underwent a tightening of the annulus using the DeVega technique, 5 patients (19.2%) had a leaflet reconstruction with patch or bicuspidalization and in 3 patients (11.5%) a leaflet debridement was performed. In 15.4% of the cohort a combination of the techniques was utilized. RESULTS: The mean follow-up time was 2.1 (0.3-5.0) years. Early survival at 30 days after surgery was 84.6%. Mean hospital stay was 11 (6.7-16) days. One-year survival was 73%. No patient required a redo procedure on the tricuspid valve during follow-up. CONCLUSION: Tricuspid valve repair is suggested as a treatment of choice according to recent guidelines on heart valve disease. If chosen correctly, various repair techniques provide good long-term results. Tricuspid valve repair may be safely applied in patients undergoing surgical isolated tricuspid valve procedures.


Subject(s)
Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Female , Germany , Humans , Length of Stay , Male , Middle Aged , Postoperative Complications , Retrospective Studies , Survival Analysis , Tricuspid Valve Insufficiency/mortality
SELECTION OF CITATIONS
SEARCH DETAIL
...