Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Materials (Basel) ; 14(15)2021 Jul 25.
Article in English | MEDLINE | ID: mdl-34361337

ABSTRACT

Cross-laminated Timber (CLT) has become an emerging board material of wood construction that is strong enough to sustain a high-rise building. However, many wooden congregate housing units overseas that utilize CLT have poor sound environments because the low mass of such wood influences sound insulation performance. In this research, we explored the effect of different CLT walls on sound insulation performance and integrated applicable sound insulation simulation tools to simplify the process of designing a CLT wall structure. This research aimed at a double wall and CLT combined with a gypsum board as the research object. The sound insulation performance test was carried out in a laboratory, while the sound insulation performance of the structure was predicted through simulation tools and prediction models and then compared with the measured values to verify the applicability of the simulation tool. The CLT with a double wall and CLT with gypsum board (CLT + GB) achieved Rw of 50 dB. The numerical simulation had better prediction performance than INSUL at the double wall, while the double wall with cavity structure was close to the measured result via mass law calculation. The INSUL-predicted CLT with a gypsum board at 500 Hz~3150 Hz was close to the measured value.

2.
PLoS One ; 14(1): e0210416, 2019.
Article in English | MEDLINE | ID: mdl-30677054

ABSTRACT

The adsorption of volatile organic compounds by building materials reduces the pollutant concentrations in indoor air. We collected three interior building materials with adsorption potentials-latex paint, micro-carbonized plywood, and moisture-buffering siding-used the sorptive building materials test (SBMT) to determine how much they reduced indoor formaldehyde (HCHO) concentrations, and then assessed the consequent reduction in human cancer risk from HCHO inhalation. Adsorption of HCHO by building materials significantly improved the effective ventilation efficiency. For example, the equivalent ventilation rate for Celite siding-used for humidity control-was 1.44 m3/(m2·h) at 25°C, 50% relative humidity (RH); the loading factor (L) was 0.4 m2/m3, and the HCHO concentration was 0.2 ppm; this effect is equivalent to a higher ventilation rate of approximately 0.6 air changes per hour in a typical Taiwanese dwelling. There was also a substantial reduction of risk in Case MCP-2 (Cin,te: 245 µg/m3, 30°C, 50% RH): males: down 5.73 × 10-4; females: down 4.84 × 10-4). The selection of adsorptive building materials for interior surfaces, therefore, significantly reduces human inhalation of HCHO. Our findings should encourage developing and using innovative building materials that help improve indoor air quality and thus provide building occupants with healthier working and living environments.


Subject(s)
Air Pollution, Indoor/analysis , Air Pollution, Indoor/prevention & control , Construction Materials/analysis , Formaldehyde/analysis , Adsorption , Adult , Air Pollutants/adverse effects , Air Pollutants/analysis , Environmental Monitoring/methods , Environmental Monitoring/standards , Female , Formaldehyde/adverse effects , Humans , Male , Paint , Risk Assessment , Taiwan , Ventilation , Volatile Organic Compounds/adverse effects , Volatile Organic Compounds/analysis , Wood
SELECTION OF CITATIONS
SEARCH DETAIL