Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Med Biol Eng Comput ; 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38822996

ABSTRACT

Research at the mesoscale bone trabeculae arrangement yields intriguing results that, due to their clinical resolution, can be applied in clinical field, contributing significantly to the diagnosis of bone-related diseases. While the literature offers quantitative morphometric parameters for a thorough characterization of the mesoscale bone network, there is a gap in understanding relationships among them, particularly in the context of various bone pathologies. This research aims to bridge these gaps by offering a quantitative evaluation of the interplay among morphometric parameters and mechanical response at mesoscale in osteoporotic and non-osteoporotic bones. Bone mechanical response, dependent on trabecular arrangement, is defined by apparent stiffness, computationally calculated using the Gibson-Ashby model. Key findings indicate that: (i) in addition to bone density, measured using X-ray absorptiometry, trabecular connectivity density, trabecular spacing and degree of anisotropy are crucial parameters for characterize osteoporosis state; (ii) apparent stiffness values exhibit strong correlations with bone density and connectivity density; (iii) connectivity density and degree of anisotropy result the best predictors of mechanical response. Despite the inherent heterogeneity in bone structure, suggesting the potential benefit of a larger sample size in the future, this approach presents a valuable method to enhance discrimination between osteoporotic and non-osteoporotic samples.

2.
Medicina (Kaunas) ; 60(3)2024 Mar 07.
Article in English | MEDLINE | ID: mdl-38541166

ABSTRACT

Background and Objectives: Spring-assisted surgery is a popular option for the treatment of non-syndromic craniosynostosis. The main drawback of this procedure is the need for a second surgery for spring removal, which could be avoided if a distractor material could be metabolised over time. Iron-Manganese alloys (FeMn) have a good trade-off between degradation rate and strength; however, their biocompatibility is still debated. Materials and Methods: In this study, the neuro-compatibility of Fe-20Mn (wt.%) was assessed using standard assays. PC-12 cells were exposed to Fe-20Mn (wt.%) and stainless steel via indirect contact. To examine the cytotoxicity, a Cell Tox Green assay was carried out after 1, 2, and 3 days of incubation. Following differentiation, a neurite morphological examination after 1 and 7 days of incubation time was carried out. The degradation response in modified Hank's solution at 1, 3, and 7 days was investigated, too. Results: The cytotoxicity assay showed a higher toxicity of Fe-20Mn than stainless steel at earlier time points; however, at the latest time point, no differences were found. Neurite morphology was similar for cells exposed to Fe-20Mn and stainless steel. Conclusions: In conclusion, the Fe-20Mn alloy shows promising neuro-compatibility. Future studies will focus on in vivo studies to confirm the cellular response to Fe-20Mn.


Subject(s)
Absorbable Implants , Stainless Steel , Humans , Materials Testing , Alloys
3.
J Hand Surg Eur Vol ; 49(4): 512-519, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37606585

ABSTRACT

Thumb amputations affect 50% of hand functionality. Common solutions consist of microsurgical treatments or silicone vacuum prosthesis. Not all patients are eligible for microsurgical treatment and the use of vacuum prosthesis is often discouraged because of their instability. On the contrary, osseointegrated prosthesis provide stable retention and osseoperception. This cadaveric study evaluated the process of a patient-matched osseointegrated prosthesis for the treatment of thumb amputees. Computed tomography (CT) medical images reconstruction provided information on metacarpal stump, used as input for the parametric screw design. Preoperative planning guided the surgeons in the surgery: postoperative placement confirmed the accuracy of the preoperative planning. Surgeons were directly involved in the implant design to meet their requirements and patient needs. Implants were inserted into cadaveric specimens in one-stage surgery. A similar process can be adopted and exploited for the treatment of different levels of thumb amputations and long finger amputations.


Subject(s)
Amputees , Thumb , Humans , Feasibility Studies , Prostheses and Implants , Cadaver , Prosthesis Design
4.
Polymers (Basel) ; 15(20)2023 Oct 18.
Article in English | MEDLINE | ID: mdl-37896373

ABSTRACT

Prosthetic reconstruction can serve as a feasible alternative, delivering both functional and aesthetic benefits to individuals with hand and finger injuries, frequent causes of emergency room visits. Implant-related infections pose significant challenges in arthroplasty and osteosynthesis procedures, contributing to surgical failures. As a potential solution to this challenge, this study developed a new class of silver (Ag)-doped chitosan (CS) coatings via electrophoretic deposition (EPD) on osseointegrated prostheses for infection therapy. These coatings were successfully applied to additively manufactured Ti6Al4V ELI samples. In the initial phase, the feasibility of the composite coating was assessed using the Thermogravimetric Analysis (TGA) and Attenuated Total Reflection (ATR) techniques. The optimized structures exhibited impressive water uptake in the range of 300-360%. Codeposition with an antibacterial agent proved effective, and scanning electron microscopy (SEM) was used to examine the coating morphology. Biologically, CS coatings demonstrated cytocompatibility when in direct contact with a fibroblast cell line (L929) after 72 h. When exposed to the Staphylococcus epidermidis strain (ATCC 12228), these coatings inhibited bacterial growth and biofilm formation within 24 h. These findings underscore the significant potential of this approach for various applications, including endoprostheses like hip implants, internal medical devices, and transcutaneous prostheses such as osseointegrated limb prosthetics for upper and lower extremities.

5.
Med Eng Phys ; 118: 104019, 2023 08.
Article in English | MEDLINE | ID: mdl-37536840

ABSTRACT

Thumb amputations leads to 50 % loss in hand functionality. To date, silicone vacuum prosthesis and autologous transplantation are the most adopted treatment solutions: nevertheless, vacuum prostheses lack in stability and cause skin issue and surgical treatment is not always accepted by patients. Osseointegrated implants were demonstrated to enhance stability, restore osseoperception and increase the time of prosthesis use. Thumb amputations present varying stump sizes: a standard size implant cannot address specificity of each patient, while a patient matched solution can meet surgeon requirements, by geometrical features of implant. The fixture presented in the current paper is the first additively manufactured patient matched osseointegrated implant for the treatment of thumb amputees. The current work aims to verify and validate a predictive finite element model (FEM) for mechanical strength of the presented fixture. FEM was demonstrated to correctly evaluate the mechanical strength of patient matched device. Minimum strength requirements were calculated in different core diameters: FEM were experimentally validated. Safety factor of 1.5 was guaranteed. Finally, considerations on performance of the prototype were carried out by means of insertion tests in Sawbones and axial pull-out force assessment. Cadaver tests to evaluate the entire procedure and production process are ongoing.


Subject(s)
Amputees , Humans , Prosthesis Design , Thumb/surgery , Prosthesis Implantation/methods , Osseointegration
6.
Orthop Surg ; 14(6): 1019-1033, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35524645

ABSTRACT

Digital trauma amputations and digital agenesis strongly affect the functionality and aesthetic appearance of the hand. Autologous reconstruction is the gold standard of treatment. Unfortunately, microsurgical options and transplantation procedures are not possible for patients who present contraindications or refuse to undergo transplantation from the toe (e.g. toe-to-thumb transplantation). To address these issues, osseointegrated finger prostheses are a promising alternative. The functional assessments registered during follow-up confirmed the promising outcomes of osseointegrated prostheses in the treatment of hand finger amputees. This review outlines (a) a detailed analysis of osseointegrated finger metallic components of the implants, (b) the surgical procedures suggested in the literature, and (c) the functional assessments and promising outcomes that demonstrate the potential of these medical osseointegrated devices in the treatment of finger amputees.


Subject(s)
Amputation, Traumatic , Amputees , Artificial Limbs , Amputation, Traumatic/surgery , Fingers/surgery , Humans , Osseointegration
7.
iScience ; 25(4): 104057, 2022 Apr 15.
Article in English | MEDLINE | ID: mdl-35345464

ABSTRACT

Manipulation by external pressure of the optical response of 2D Metal Halide Perovskites (MHPs) is a fascinating route to tune their properties and promote the emergence of novel features. We investigate here DA2PbI4 and DA2GeI4 (DA = decylammonium) perovskites in the pressure range up to ∼12 GPa by X-ray powder diffraction, absorption, and photoluminescence spectroscopy. Although the two systems share a similar structural evolution with pressure, the optical properties are rather different and influenced by Pb or Ge. DA2PbI4 shows a progressive red shift from 2.28 eV (P = 0 GPa) to 1.64 eV at 11.5 GPa, with a narrow PL emission, whereas DA2GeI4, changes from a non-PL system at ambient pressure to a clear broadband emitter centered around 730 nm with an intensity maximum at about 3.7 GPa. These results unveil the role of the central atom on the nature of emission under pressure in 2D MHPs containing a long alkyl chain.

8.
Materials (Basel) ; 14(15)2021 Jul 27.
Article in English | MEDLINE | ID: mdl-34361381

ABSTRACT

The present work explores the effect of a stress relieving heat treatment on the microstructure, tensile properties and residual stresses of the laser powder bed fused AlSi9Cu3 alloy. In fact, the rapid cooling rates together with subsequent heating/cooling cycles occurred during layer by layer additive manufacturing production make low temperature heat treatments desirable for promoting stress relaxation as well as limited grain growth: this combination can offer the opportunity of obtaining the best compromise between high strength, good elongation to failure and limited residual stresses. The microstructural features were analysed, revealing that the high cooling rate, induced by the process, caused a large supersaturation of the aluminum matrix and the refinement of the eutectic structure. Microhardness versus time curve, performed at 250 °C, allowed to identify a stabilization of the mechanical property at a duration of 25 h. The microstructure and the mechanical properties of the samples heat treated at 25 h and at 64 h, considered as a reference for the conventionally produced alloy, were compared with the ones of the as-built alloy. Finally, it was shown that a 59% reduction of the principal residual stresses could be achieved after the 25 h-long treatment and such evolution was correlated to the mechanical behaviour.

9.
Proc Natl Acad Sci U S A ; 116(38): 18777-18782, 2019 09 17.
Article in English | MEDLINE | ID: mdl-31451632

ABSTRACT

As meticulously observed and recorded by Darwin, the leaves of the carnivorous plant Drosera capensis L. slowly fold around insects trapped on their sticky surface in order to ensure their digestion. While the biochemical signaling driving leaf closure has been associated with plant growth hormones, how mechanical forces actuate the process is still unknown. Here, we combine experimental tests of leaf mechanics with quantitative measurements of the leaf microstructure and biochemistry to demonstrate that the closure mechanism is programmed into the cellular architecture of D. capensis leaves, which converts a homogeneous biochemical signal into an asymmetric response. Inspired by the leaf closure mechanism, we devise and test a mechanical metamaterial, which curls under homogeneous mechanical stimuli. This kind of metamaterial could find possible applications as a component in soft robotics and provides an example of bio-inspired design.


Subject(s)
Biomimetic Materials/chemistry , Drosera/physiology , Plant Physiological Phenomena , Biomechanical Phenomena , Cell Wall/physiology , Elastic Modulus , Indoleacetic Acids/metabolism , Movement , Plant Leaves/anatomy & histology , Plant Leaves/growth & development , Plant Leaves/metabolism , Plant Leaves/physiology
10.
J Chem Phys ; 140(21): 214704, 2014 Jun 07.
Article in English | MEDLINE | ID: mdl-24908032

ABSTRACT

In this work, the surface tension and density of Si-Ge liquid alloys were determined by the pendant drop method. Over the range of measurements, both properties show a linear temperature dependence and a nonlinear concentration dependence. Indeed, the density decreases with increasing silicon content exhibiting positive deviation from ideality, while the surface tension increases and deviates negatively with respect to the ideal solution model. Taking into account the Si-Ge phase diagram, a simple lens type, the surface tension behavior of the Si-Ge liquid alloys was analyzed in the framework of the Quasi-Chemical Approximation for the Regular Solutions model. The new experimental results were compared with a few data available in the literature, obtained by the containerless method.

11.
J Mater Sci Mater Med ; 25(10): 2277-85, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24928669

ABSTRACT

Shape memory alloys based on NiTi have found their main applications in manufacturing of new biomedical devices mainly in surgery tools, stents and orthopedics. Porous NiTi can exhibit an engineering elastic modulus comparable to that of cortical bone (12-17 GPa). This condition, combined with proper pore size, allows good osteointegration. Open cells porous NiTi was produced by self propagating high temperature synthesis (SHS), starting from Ni and Ti mixed powders. The main NiTi phase is formed during SHS together with other Ni-Ti compounds. The biocompatibility of such material was investigated by single culture experiment and ionic release on small specimen. In particular, NiTi and porous NiTi were evaluated together with elemental Ti and Ni reference metals and the two intermetallic TiNi3, Ti2Ni phases. This approach permitted to clearly identify the influence of secondary phases in porous NiTi materials and relation with Ni-ion release. The results indicated, apart the well-known high toxicity of Ni, also toxicity of TiNi3, whilst phases with higher Ti content showed high biocompatibility. A slightly reduced biocompatibility of porous NiTi was ascribed to combined effect of TiNi3 presence and topography that requires higher effort for the cells to adapt to the surface.


Subject(s)
Alloys/chemical synthesis , Biocompatible Materials/chemistry , Hot Temperature , Nickel/chemistry , Polymerization , Titanium/chemistry , Alloys/chemistry , Alloys/pharmacology , Cells, Cultured , Humans , Materials Testing , Nickel/pharmacology , Osteoblasts/drug effects , Osteoblasts/physiology , Porosity , Powders , Surface Properties , Titanium/pharmacology
SELECTION OF CITATIONS
SEARCH DETAIL
...