Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Br J Nurs ; 33(14): S42-S49, 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39023024

ABSTRACT

AIM: Acceptability of a new safety-engineered peripherally inserted intravenous catheter (PIVC) with multiple access blood control (MBC) was evaluated in this observational study by experienced volunteer clinicians on healthy volunteers. METHODS: Clinicians and healthy volunteers were recruited for this study. Observers documented study procedures, including if there was any blood leakage from the catheter hub at various times during hub connections and disconnections and how many attempts it took a clinician to get a successful stick. Clinicians responded to yes-or-no and Likert-scale questionnaires describing their experiences with PIVC with MBC after each procedure. Questionnaire data were summarized by frequency and percent of responses; analyses were conducted using binomial statistics. RESULTS: Overall, clinicians considered PIVC with MBC to be acceptable (93.6% agreement). Clinicians were able to easily remove the catheter protective cap, insert the catheter, visualize primary and secondary flashbacks, easily remove the needle from the catheter hub and determine if the safety clip was activated after withdrawing the needle. In addition, they were able to connect or disconnect and flush extension sets. Clinicians did not have to change their insertion technique, found the catheter easy to insert, and believed the catheter would protect them from blood exposure during insertion of the catheter and subsequent hub accesses (agreement ranged from 82.3% to 98.9%). CONCLUSIONS: No blood leakage was observed from the catheter hub at any time during the procedures. Overall, clinicians found the new PIVC with MBC to be acceptable, easy to use, and functioned properly. HIGHLIGHTS: Acceptability, usability, and ease of use of a new safety-engineered PIVC with MBC was evaluated. PIVC with MBC was >93% acceptable: prevented blood exposure after multiple insertions/removals. Most clinicians (96%) achieved first stick success when using their product. PIVC with MBC was easy to use, worked properly and allowed clinicians to keep their PIVC technique.


Subject(s)
Catheterization, Peripheral , Humans , Female , Male , Adult , Attitude of Health Personnel , Surveys and Questionnaires , Equipment Design , Middle Aged
2.
J Clin Aesthet Dermatol ; 16(4): 43-52, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37077927

ABSTRACT

Objectives: The primary aim of this study was to assess the change in acne lesions and severity within all treatment groups over the course of a six-month study. Methods: This was a six-month, multisite, randomized, double-blind, controlled study in female subjects with mild-to-moderate acne to assess the clinical and psychological outcomes of treatment with biofilm disrupting acne cream 2x, biofilm disrupting acne cream 1x, biofilm disrupting acne cream without salicylic acid, 2.5% benzoyl peroxide (BPO) gel, and placebo. Subjects applied the assigned product to their face twice daily and were evaluated for clinical acne and quality of life outcomes at baseline and after six, 12, 18, and 24 weeks of treatment. Results: After 24 weeks of use, subjects treated with biofilm disrupting acne cream 2x had a significantly greater improvement in the Investigator Global Assessment (IGA), compared to those treated with 2.5% BPO gel. Based on dermatologic assessments, biofilm disrupting acne cream 2x, biofilm disrupting acne cream 1x, biofilm disrupting acne cream without salicylic acid, and placebo control were associated with less erythema and dryness, compared to 2.5% BPO gel. Limitations: Assessments within this study had the potential for subjective differences due to variability between evaluators. Conclucion: Biofilm disrupting acne cream 2x and biofilm disrupting acne cream 1x provided equivalent efficacy to 2.5% BPO gel with less of the adverse effects commonly associated with BPO, such as erythema and dryness. Both the biofilm disrupting acne cream without salicylic acid and the placebo control were associated with mild improvements to acne symptoms over the course of the 24-week study. Trial Registry Information: ClinicalTrials.gov, NCT03106766.

3.
Adv Ther ; 36(12): 3381-3389, 2019 12.
Article in English | MEDLINE | ID: mdl-31602573

ABSTRACT

INTRODUCTION: AG200-15, an investigational transdermal contraceptive delivery system or patch, is designed to be a low-dose, non-daily, combined hormonal contraceptive option for women. In this phase 1 study, the in vivo adhesion of the AG200-15 patch was compared to Xulane®, the only contraceptive patch available in the USA. METHODS: This phase 1, randomized, open-label, single-dose, two-treatment, two-period crossover adhesion study compared the 7-day adhesion of the AG200-15 and Xulane contraceptive patches. Eighty-three women, ages 18 to 35 years old, with body mass index (BMI) ≥ 19 kg/m2 and < 35 kg/m2, and weight ≥ 48 kg and < 90 kg were enrolled. Trained study site personnel used a five-point scale to assess patch adhesion daily. A score of 0 reflected at least 90% adhesion; while a score of 4 represented complete detachment of the patch. The primary objective was to compare the adhesion properties of the two patches; AG200-15 would be considered statistically non-inferior to Xulane if the upper 95% confidence limit (CL) of the mean difference in adhesion scores was below + 0.15. RESULTS: The overall mean (standard deviation) scores for AG200-15 (N = 78) and Xulane (N = 77) were 0.14 (0.28) and 0.39 (0.40), respectively (lower scores on the adhesion scale indicate better adhesion). The study demonstrated a difference in mean adhesion scores of - 0.24, meeting the prespecified non-inferiority criterion by demonstrating a one-sided upper CL of - 0.16. Thus, the in vivo adhesion of AG200-15 was shown to be non-inferior to that of Xulane. Most subjects experienced no skin irritation at the application site for either patch and no serious adverse event was reported in the study. CONCLUSION: The in vivo adhesion of AG200-15 is non-inferior to that of Xulane on the basis of the prespecified criterion of the upper bound of the one-sided 95% CL for the mean adhesion score difference being below + 0.15. Both patches were generally well tolerated. FUNDING: Agile Therapeutics, Inc.


Subject(s)
Contraceptive Agents/therapeutic use , Ethinyl Estradiol/therapeutic use , Levonorgestrel/therapeutic use , Norgestrel/analogs & derivatives , Administration, Cutaneous , Adolescent , Adult , Body Mass Index , Contraceptive Agents/administration & dosage , Contraceptive Agents/adverse effects , Cross-Over Studies , Dose-Response Relationship, Drug , Drug Combinations , Equivalence Trials as Topic , Ethinyl Estradiol/administration & dosage , Ethinyl Estradiol/adverse effects , Female , Humans , Levonorgestrel/administration & dosage , Levonorgestrel/adverse effects , Norgestrel/administration & dosage , Norgestrel/adverse effects , Norgestrel/therapeutic use , Oximes/administration & dosage , Oximes/adverse effects , Oximes/therapeutic use , Young Adult
4.
Drugs R D ; 19(1): 57-66, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30649711

ABSTRACT

OBJECTIVE: This study was conducted to evaluate the taste and grittiness of two formulations of Riomet® ER (metformin hydrochloride for extended release [ER] oral suspension 100 mg/mL) differing only in their flavoring agents (strawberry and grape) in comparison with two commercially available immediate-release (IR) formulations of metformin, Riomet® Cherry (metformin hydrochloride oral solution 500 mg/5 mL) and metformin IR tablets (metformin hydrochloride IR tablets 500 mg), in healthy human subjects aged 10-70 years. METHODS: Five comparison sets (i.e., Riomet® Cherry vs. Riomet® ER Strawberry; Riomet® Cherry vs. Riomet® ER Grape; metformin IR vs. Riomet® ER Strawberry; metformin IR vs. Riomet® ER Grape; and Riomet® Cherry vs. metformin IR) were evaluated. Riomet® ER was reconstituted as instructed on the label. Metformin IR tablets were crushed one at a time into a fine powder using a pharmaceutical pill crusher and mixed with 5 mL of water. A 2.5-mL dose of each product was administered to each subject. Subjects were instructed not to swallow any of the products. Each product in the comparison set was rated by the subjects for taste and grittiness according to a 7-point hedonic facial scale and a 5-point level of agreement scale. A comparison questionnaire was also completed by the subjects after evaluating each set. In all, 56 subjects were enrolled and 55 subjects completed the study. The taste preference was statistically evaluated. RESULTS AND CONCLUSIONS: All Riomet® formulations were significantly preferred overall to metformin IR crushed tablets. Both the strawberry and the grape flavors of Riomet® ER tended to be preferred to Riomet® Cherry.


Subject(s)
Flavoring Agents/administration & dosage , Flavoring Agents/chemistry , Metformin/administration & dosage , Metformin/chemistry , Taste/physiology , Administration, Oral , Adolescent , Adult , Aged , Chemistry, Pharmaceutical , Child , Delayed-Action Preparations , Drug Compounding , Female , Humans , Hypoglycemic Agents/administration & dosage , Hypoglycemic Agents/chemistry , Male , Middle Aged , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL