Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
1.
J Anal Toxicol ; 47(1): 43-51, 2023 Feb 21.
Article in English | MEDLINE | ID: mdl-35388429

ABSTRACT

Biomonitoring of human exposure to reactive electrophilic chemicals such as ethylene oxide (EO) has been commonly based on the determination of adducts with N-terminal valine in blood protein globin, but a systematic search has also been undertaken to find surrogate markers enabling non-invasive sampling. Recently, N-(2-hydroxyethyl)-L-valyl-L-leucine (HEVL) has been identified as an ultimate cleavage product of EO-adducted globin in the urine of occupationally exposed workers. Herein, full validation of the analytical procedure consisting of solid-phase extraction of HEVL from urine samples (2 mL) followed by high-performance liquid chromatography-electrospray ionization-high-resolution mass spectrometry determination using deuterium-labeled HEVL as an internal standard (IS) is described. Method limit of quantitation is 0.25 ng/mL, and its selectivity is excellent as demonstrated by the invariable ratio of the qualifier and quantifier ion intensities across diverse urine samples and synthetic standard. The linear calibration model was applicable over the whole concentration range tested (0.25-10 ng/mL). The method accuracy assessed as a recovery of HEVL using a spiking experiment was 98-100%. Within-day precision of the method ranged from 1.8% to 3.0%, while the results from consecutive analytical runs conducted within 1 week or within 10-150 weeks differed in the range of 2.2-9.7%. The stability study on urine samples (-20°C up to 3 years, freeze-and-thaw up to 10 cycles) as well as on aqueous solutions (5°C up to 4 months) indicated no relevant changes in HEVL concentration (≤4%) over the time tested. Analytical responses of both HEVL and IS correlated with urinary creatinine as an index of matrix composition, but this matrix effect was mostly eliminated using the HEVL/IS peak area ratio, attaining the IS-normalized relative matrix effect <3%. In conclusion, the method complied successfully with the bioanalytical method validation criteria, making it a reliable tool for HEVL determination in human biomonitoring.


Subject(s)
Dipeptides , Ethylene Oxide , Humans , Chromatography, High Pressure Liquid , Leucine , Globins , Reproducibility of Results
2.
Arch Toxicol ; 95(1): 79-89, 2021 01.
Article in English | MEDLINE | ID: mdl-33156369

ABSTRACT

Novel aminonaphthylcysteine (ANC) adducts, formed via naphthylnitrenium ions and/or their metabolic precursors in the biotransformation of naphthylamines (NA) and nitronaphthalenes (NN), were identified and quantified in globin of rats dosed intraperitoneally with 0.16 mmol/kg b.w. of 1-NA, 1-NN, 2-NA and 2-NN. Using HPLC-ESI-MS2 analysis of the globin hydrolysates, S-(1-amino-2-naphthyl)cysteine (1A2NC) together with S-(4-amino-1-naphthyl)cysteine (4A1NC) were found in rats given 1-NA or 1-NN, and S-(2-amino-1-naphthyl)cysteine (2A1NC) in those given 2-NA or 2-NN. The highest level of ANC was produced by the most mutagenic and carcinogenic isomer 2-NA (35.8 ± 5.4 nmol/g globin). The ratio of ANC adduct levels for 1-NA, 1-NN, 2-NA and 2-NN was 1:2:100:3, respectively. Notably, the ratio of 1A2NC:4A1NC in globin of rats dosed with 1-NA and 1-NN differed significantly (2:98 versus 16:84 respectively), indicating differences in mechanism of the adduct formation. Moreover, aminonaphthylmercapturic acids, formed via conjugation of naphthylnitrenium ions and/or their metabolic precursors with glutathione, were identified in the rat urine. Their amounts excreted after dosing rats with 1-NA, 1-NN, 2-NA and 2-NN were in the ratio 1:100:40:2, respectively. For all four compounds tested, haemoglobin binding index for ANC was several-fold higher than that for the sulphinamide adducts, generated via nitrosoarene metabolites. Due to involvement of electrophilic intermediates in their formation, ANC adducts in globin may become toxicologically more relevant biomarkers of cumulative exposure to carcinogenic or non-carcinogenic arylamines and nitroarenes than the currently used sulphinamide adducts.


Subject(s)
Globins/metabolism , Naphthalenes/blood , 1-Naphthylamine/administration & dosage , 1-Naphthylamine/metabolism , 1-Naphthylamine/toxicity , 2-Naphthylamine/administration & dosage , 2-Naphthylamine/metabolism , 2-Naphthylamine/toxicity , Acetylcysteine/analogs & derivatives , Acetylcysteine/urine , Animals , Biomarkers/blood , Biomarkers/urine , Cysteine , Injections, Intraperitoneal , Male , Naphthalenes/administration & dosage , Naphthalenes/toxicity , Protein Binding , Rats, Wistar
3.
Toxicol Lett ; 326: 18-22, 2020 Jun 15.
Article in English | MEDLINE | ID: mdl-32145395

ABSTRACT

Ethylene oxide (EO), a carcinogenic chemical used as an industrial intermediate and sterilant, forms covalent adducts with DNA and proteins. The adduct with N-terminal valine [N-(2-hydroxyethyl)-l-valine, HEV] in blood protein globin has been employed as a principal biomarker of cumulative exposures to EO. However, as sampling of blood is inconvenient in routine occupational health practice, a non-invasive alternative to globin analysis has been investigated. Following identification of N-(2-hydroxyethyl)-l-valyl-l-leucine (HEVL) as ultimate cleavage product of EO-adducted globin excreted in the rat urine, here we report for the first time on the presence of HEVL in the urine of humans. In 18 sterilization workers, urinary HEVL ranged from 0.67 to 11.98 µg/g creatinine (mean ± SD: 5.04 ± 3.14 µg/g creat) and correlated with HEV: HEVL (µg/g creat) = 0.833 HEV (nmol/g globin) + 1.19 (R2 = 0.45). As unexpectedly high levels of urinary HEVL were found also in controls (mean ± SD: 0.97 ± 0.37 µg/g creat, n = 32), HEVL is not proposed for the accurate assessment of sub-ppm exposures to EO. On the other hand, non-invasive sampling and facile work-up procedure predetermine HEVL for screening purposes to identify subjects approaching to or exceeding occupational exposure limit for EO (1.8 mg/m3) to be re-examined by the more sensitive reference analysis for HEV.


Subject(s)
Biological Monitoring/methods , Biomarkers/urine , Carcinogens/toxicity , Ethylene Oxide/urine , Occupational Exposure/adverse effects , Valine/urine , Adult , Female , Humans , Male , Middle Aged
4.
Toxicol Lett ; 298: 76-80, 2018 Dec 01.
Article in English | MEDLINE | ID: mdl-29936296

ABSTRACT

Ethylene oxide (EO), an industrial intermediate and gaseous sterilant for medical devices, is carcinogenic to humans, which warrants minimization of exposure in the workplaces. The principal analytical strategy currently used in biomonitoring of exposure to EO consists in the conversion of N-(2-hydroxyethyl) adduct at the N-terminal valine (HEV) in globin to a specific thiohydantoin derivative accessible to GC-MS analysis (modified Edman degradation, MED). Though highly sensitive, the method is laborious and, at least in our hands, not sufficiently robust. Here we developed an alternative strategy of HEV determination based on acidic hydrolysis (AH) of globin followed directly by HPLC-ESI-MS2 analysis. Limit of quantitation is ca. 25 pmol HEV/g globin. Comparative analyses of globin samples from EO-exposed workers by both the AH-based and MED-based methods provided results that correlated well with each other (R2 > 0.95) but those obtained with AH were significantly more accurate (according to external quality control programme G-EQUAS) and repeatible (5% and 6% for intra-day and between-day analyses, respectively). In conclusion, the new AH-based method surpassed MED being similarly sensitive, much less laborious and more reliable, thus applicable as an effective tool for biomonitoring of EO in exposure control and risk assessment.


Subject(s)
Chromatography, High Pressure Liquid , Environmental Monitoring/methods , Ethylene Oxide/blood , Globins/analysis , Inhalation Exposure , Occupational Exposure , Occupational Health , Spectrometry, Mass, Electrospray Ionization , Valine/analogs & derivatives , Acids/chemistry , Environmental Biomarkers , Ethylene Oxide/adverse effects , Humans , Hydrolysis , Inhalation Exposure/adverse effects , Male , Occupational Exposure/adverse effects , Reproducibility of Results , Risk Assessment , Valine/blood
5.
Anal Bioanal Chem ; 397(2): 433-8, 2010 May.
Article in English | MEDLINE | ID: mdl-19795109

ABSTRACT

Ethylene glycol monobutyl ether (EGBE), an industrial solvent, is absorbed by the body not only by inhalation but also by dermal absorption (liquid or vapour). EGBE is metabolized to butoxyacetic acid (BAA). Pooled freeze-dried urine candidate reference material (RM) was prepared from urine obtained from persons occupationally exposed to EGBE. This material has the advantage of containing butoxyacetic acid in both the free and conjugated (glutamine and glycine) forms, as found in native urine. In all GC method modifications used, acid hydrolysis was used to release BAA from its conjugated form. The amount of butoxyacetic acid in homogeneity and stability testing was measured by GC after derivatisation with N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide. Detection was by MS in EI mode, in the authors' laboratory. For interlaboratory comparison of the reference material GC methods with MS, FID, and ECD were used. Different extraction solvents (dichloromethane-isopropanol 2:1, ethyl acetate, or dichloromethane) and derivatisation reagents (trimethylsilyldiazomethane, N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide) were used. Using ANOVA (at the statistical level alpha = 0.05) no changes were found in the concentration of butoxyacetic acid during fifteen month isochronous stability testing, or in homogeneity testing. The uncertainty contributions were u (h) = 8.8 mg L(-1) and u (s) = 6.5 mg L(-1). The concentration of butoxyacetic acid in freeze-dried urine RM was evaluated from the results of eight laboratory data sets within an interlaboratory comparison by use of the interactive statistical software IPECA. The contribution to total uncertainty derived from interlaboratory comparison was u (i) = 12.7 mg L(-1). The reference value (c = 273 +/- 33 mg L(-1)) is an unweighted arithmetic average of accepted results. The value is traceable to the pure butoxyacetic acid (98% w/w; Acros Organic #257760010) used as calibrant. The uncertainty given is combined expanded uncertainty derived from the results from interlaboratory comparison, and from homogeneity and stability tests (k = 2). The reference material will be used to verify method performance in the biological monitoring of occupational exposure to EGBE.


Subject(s)
Ethylene Glycols/metabolism , Gas Chromatography-Mass Spectrometry/methods , Glycolates/standards , Glycolates/urine , Humans , Occupational Exposure , Reference Standards
SELECTION OF CITATIONS
SEARCH DETAIL