1.
J Am Med Dir Assoc ; 23(2): 311-314.e2, 2022 02.
Article in English | MEDLINE | ID: mdl-34896058

ABSTRACT

The COVID-19 pandemic presented significant challenges to face-to-face communication with people residing in post-acute and long-term care (PALTC) settings. Telemedicine is an alternative, but facility staff may be overburdened with the management of the equipment. Here we introduce the use of a mobile HIPPA-compliant telepresence robot (MTR) to bridge this barrier, which may be beneficial to reimagine options for PALTC in the future.


Subject(s)
COVID-19 , Robotic Surgical Procedures , Telemedicine , Humans , Nursing Homes , Pandemics , SARS-CoV-2
2.
Clin Infect Dis ; 44(11): 1408-14, 2007 Jun 01.
Article in English | MEDLINE | ID: mdl-17479934

ABSTRACT

BACKGROUND: Needleless intravascular catheter connector valves have been introduced into clinical practice to minimize the risk of needlestick injury. However, infection-control risks associated with these valves may be underappreciated. In March 2005, a dramatic increase in bloodstream infections was noted in multiple patient care units of a hospital in temporal association with the introduction of a needleless valve into use. METHODS: Surveillance for primary bloodstream infection was conducted using standard methods throughout the hospital. Blood culture contamination rates were monitored. Cultures were performed using samples obtained from intravascular catheter connector valves. RESULTS: The relative risk of bloodstream infection for the time period in which the suspect connector valve was in use, compared with baseline, was 2.79 (95% confidence interval, 2.27-3.43). In critical care units, the rate of primary bloodstream infection increased with the introduction of the valve from 3.87 infections per 1000 catheter-days to 10.64 infections per 1000 catheter-days (P<.001), and it decreased to 5.59 infections per 1000 catheter-days (P=.02) in the 6 months following removal of the device from use. Similarly, in inpatient nursing units, the rate of bloodstream infection increased from 3.47 infections per 1000 catheter-days to 7.3 infections per 1000 catheter-days (P=.02) following introduction of the device, and it decreased to 2.88 infections per 1000 catheter-days (P=.57) following removal of the device from use. Similar events occurred in the cooperative care units. The rate of blood culture contamination did not substantially change over the course of the study. Of 37 valves that were subjected to microbiological sample testing, 24.3% yielded microbes, predominantly coagulase-negative staphylococci. CONCLUSION: A significant association between primary bloodstream infection and a needleless connector valve was observed. Evaluation of needleless connector valves should include a thorough assessment of infection risks in prospective randomized trials prior to their introduction to the market.


Subject(s)
Bacteremia/epidemiology , Bacteremia/etiology , Catheterization/instrumentation , Disease Outbreaks , Equipment Contamination , Humans , Risk Factors