Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Publication year range
1.
Biochem Biophys Res Commun ; 702: 149631, 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38335703

ABSTRACT

Major depressive disorder is accompanied by a high metabolic illness comorbidity and patients with atypical depression are a subgroup with particularly high risk of obesity, dyslipidemia, and metabolic syndrome; however, the underlying mechanisms have not been fully elucidated. In this study, we examined visceral fat deposition, lipid profiles in the liver, and gut microbiota in sub-chronic and mild social defeat stress (sCSDS)-exposed C57BL/6J mice, which exhibit atypical depression-like phenotypes, i.e., increased body weight and food and water intake. We found that visceral fat mass and levels of hepatic cholesterol and bile acids in sCSDS-exposed mice were significantly increased compared to those in controls. The expression of hepatic small heterodimer partner, a negative regulator of cholesterol metabolism, was significantly elevated in sCSDS-exposed mice. We also found that gut microbial diversity and composition including lower relative abundance of Bacteroides spp. and Bifidobacterium spp. in sCSDS-exposed mice were different from those in controls. In addition, relative abundance of Bacteroides spp. and Bifidobacterium spp. was significantly and negatively correlated with body weight, visceral fat mass, and hepatic cholesterol and bile acids levels. These results indicate that sCSDS-exposure induces dysbiosis, and thereby contributes to metabolic disorder development.


Subject(s)
Depressive Disorder, Major , Social Defeat , Humans , Mice , Animals , Mice, Inbred C57BL , Bile Acids and Salts/metabolism , Depressive Disorder, Major/metabolism , Intra-Abdominal Fat , Cholesterol/metabolism , Body Weight , Liver/metabolism , Diet, High-Fat
2.
J Radiat Res ; 64(4): 644-650, 2023 Jul 18.
Article in English | MEDLINE | ID: mdl-37280131

ABSTRACT

In volumetric modulated arc therapy (VMAT), the effect of an increase in skin surface dose due to topical agents might be negligible. We investigated the bolus effects of three types of topical agents in VMAT for head and neck cancer (HNC). Topical agents of different thicknesses (0.1, 0.5 and 2 mm) were prepared. When each topical agent was set, the surface doses were measured for the anterior static field and VMAT, with and without a thermoplastic mask. No significant differences were observed among the three topical agents. For topical agent thicknesses of 0.1, 0.5 and 2 mm, the increases in surface dose for the anterior static field without the thermoplastic mask were 7-9, 30-31 and 81-84%, respectively. With the thermoplastic mask, the corresponding increases were 5, 12-15 and 41-43%, respectively. The increases in surface dose for VMAT without the thermoplastic mask were 5-8, 16-19 and 36-39%, respectively, and those with the thermoplastic mask were 4, 7-10 and 15-19%, respectively. The rate of increase in surface dose with the thermoplastic mask was smaller than that without the thermoplastic mask. The increase in surface dose with topical agents of clinical standard thickness (0.02 mm) was estimated to be 2% with the thermoplastic mask. The increase in surface dose with topical agents in dosimetric simulation, compared with control situation, is not significant in clinical conditions for HNC patients.


Subject(s)
Head and Neck Neoplasms , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Head and Neck Neoplasms/radiotherapy , Radiometry
3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(3): 252-261, 2023 Mar 20.
Article in Japanese | MEDLINE | ID: mdl-36709971

ABSTRACT

PURPOSE: The questionnaire survey investigated whether "Explainer videos about radiation therapy (RT-Video)", "Treatment of breast cancer patients by female radiation therapists (F-RTT)" and "Treating male patients while wearing underwear in pelvic radiation therapy (M-RTT)" can improve patient's satisfaction. METHODS: The RT-Video survey included questions regarding the impression of radiation therapy, improving its understanding, and anxiety reduction (102 patients received radiation therapy). Fifty-one breast cancer patients were asked whether they preferred an F-RTT treatment. Subsequently, the patients treated with F-RTT (41 patients) and M-RTT (50 patients) were surveyed about their treatment satisfaction on a five-point scale. RESULTS: RT-Video improved the understanding of radiation therapy for 86 out of 102 patients (84%). In all, 68 out of 102 patients (68%) had a negative impression of radiotherapy; among them, watching the RT-Video reduced anxiety in 63% of patients. A total of 14 out of 51 breast cancer patients (28%) preferred the F-RTT treatment. The percentage of patients who received treatment satisfaction by F-RTT and M-RTT was 95% and 84%, respectively. CONCLUSION: RT-Video, F-RTT and M-RTT treatments improved patients' satisfaction.


Subject(s)
Breast Neoplasms , Radiation Oncology , Humans , Male , Female , Patient Satisfaction , Breast Neoplasms/radiotherapy
4.
Phys Med ; 92: 24-31, 2021 Nov 24.
Article in English | MEDLINE | ID: mdl-34837857

ABSTRACT

PURPOSE: To evaluate the utility of the use of iterative cone-beam computed tomography (CBCT) for machine log file-based dose verification during volumetric modulated arc therapy (VMAT) for prostate cancer patients. METHODS: All CBCT acquisition data were used to reconstruct images with the Feldkamp-Davis-Kress algorithm (FDK-CBCT) and the novel iterative algorithm (iCBCT). The Hounsfield unit (HU)-electron density curves for CBCT images were created using the Advanced Electron Density Phantom. The I'mRT and anthropomorphic phantoms were irradiated with VMAT after CBCT registration. Subsequently, fourteen prostate cancer patients received VMAT after CBCT registration. Machine log files and both CBCT images were exported to the PerFRACTION software, and a 3D patient dose was reconstructed. Mean dose for planning target volume (PTV), the bladder, and rectum and the 3D gamma analysis were evaluated. RESULTS: For the phantom studies, the variation of HU values was observed at the central position surrounding the bones in FDK-CBCT. There were almost no changes in the difference of doses at the isocenter between measurement and reconstructed dose for planning CT (pCT), FDK-CBCT, and iCBCT. Mean dose differences of PTV, rectum, and bladder between iCBCT and pCT were approximately 2% lower than those between FDK-CBCT and pCT. For the clinical study, average gamma analysis for 2%/2 mm was 98.22% ± 1.07 and 98.81% ± 1.25% in FDK-CBCT and iCBCT, respectively. CONCLUSIONS: A similar machine log file-based dose verification accuracy is obtained for FDK-CBCT and iCBCT during VMAT for prostate cancer patients.

5.
Rep Pract Oncol Radiother ; 26(2): 281-290, 2021.
Article in English | MEDLINE | ID: mdl-34211779

ABSTRACT

BACKGROUND: The aim of the study was to evaluate analysis criteria for the identification of the presence of rectal gas during volumetric modulated arc therapy (VMAT) for prostate cancer patients by using electronic portal imaging device (EPID)-based in vivo dosimetry (IVD). MATERIALS AND METHODS: All measurements were performed by determining the cumulative EPID images in an integrated acquisition mode and analyzed using PerFRACTION commercial software. Systematic setup errors were simulated by moving the anthropomorphic phantom in each translational and rotational direction. The inhomogeneity regions were also simulated by the I'mRT phantom attached to the Quasar phantom. The presence of small and large air cavities (12 and 48 cm3) was controlled by moving the Quasar phantom in several timings during VMAT. Sixteen prostate cancer patients received EPID-based IVD during VMAT. RESULTS: In the phantom study, no systematic setup error was detected in the range that can happen in clinical (< 5-mm and < 3 degree). The pass rate of 2% dose difference (DD2%) in small and large air cavities was 98.74% and 79.05%, respectively, in the appearance of the air cavity after irradiation three quarter times. In the clinical study, some fractions caused a sharp decline in the DD2% pass rate. The proportion for DD2% < 90% was 13.4% of all fractions. Rectal gas was confirmed in 11.0% of fractions by acquiring kilo-voltage X-ray images after the treatment. CONCLUSIONS: Our results suggest that analysis criteria of 2% dose difference in EPID-based IVD was a suitable method for identification of rectal gas during VMAT for prostate cancer patients.

6.
J Appl Clin Med Phys ; 22(3): 254-260, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33656261

ABSTRACT

PURPOSE: This study investigated the intra-fractional motion (IM) of patients immobilized using the QFix Encompass Immobilization System during HyperArc (HA) treatment. METHOD: HA treatment was performed on 89 patients immobilized using the Encompass. The IM during treatment (including megavoltage (MV) registration) was analyzed for six degrees of freedom including three axes of translation (anterior-posterior, superior-inferior (SI) and left-right (LR)) and three axes of rotation (pitch, roll, and yaw). Then, the no corrected IM (IMNC ) was retrospectively simulated (excluding MV registration) in three directions (SI, LR, and yaw). Finally, the correlation between the treatment time and the IM of the 3D vector was assessed. RESULTS: The average IM in terms of the absolute displacement were 0.3 mm (SI), 0.3 mm (LR) and 0.2° (yaw) for Stereotactic radiosurgery (SRS), and 0.3 mm (SI), 0.2 mm (LR), and 0.2° (yaw) for stereotactic radiotherapy (SRT). The absolute maximum values of IM were <1 mm along the SI and LR axes and <1° along the yaw axis. The absolute maximum displacements for IMNC were >1 mm along the SI and LR axes and >1° along the yaw axis. In the correlation between the treatment time and the IM, the r-values were -0.025 and 0.027 for SRS and SRT respectively, along the axes of translation. For the axes of rotation, the r-values were 0.012 and 0.206 for SRS and SRT, respectively. CONCLUSION: Encompass provided patient immobilization with adequate accuracy during HA treatment. The absolute maximum displacement IM was less than IMNC along the translational/rotational axes, and no statistically significant relationship between the treatment time and the IM was observed.


Subject(s)
Brain Neoplasms , Radiosurgery , Brain Neoplasms/radiotherapy , Humans , Immobilization , Patient Positioning , Radiotherapy Planning, Computer-Assisted , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...