Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 63
Filter
1.
Osteoporos Sarcopenia ; 10(1): 16-21, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38690542

ABSTRACT

Objectives: Diagnosis and treatment of osteoporosis are instrumental in obtaining good outcomes of hip surgery. Measuring bone mineral density (BMD) using dual-energy X-ray absorptiometry (DXA) is the gold standard for diagnosing osteoporosis. However, due to limited access to DXA, there is a need for a screening tool to identify patients at a higher risk of osteoporosis. We analyzed the potential utility of the Osteoporosis Self-assessment Tool for Asians (OSTA) as a screening tool for osteoporosis. Methods: A total of 1378 female patients who underwent hip surgery at 8 institutions were analyzed. For each patient, the BMD of the proximal femoral region was measured by DXA (DXA-BMD), and the correlation with OSTA score (as a continuous variable) was assessed. Receiver operating characteristic (ROC) curve analysis was performed to assess the ability of OSTA score to predict osteoporosis. Lastly, the OSTA score was truncated to yield an integer (OSTA index) to clarify the percentage of patients with osteoporosis for each index. Results: DXA-BMD showed a strong correlation with OSTA (r = 0.683; P < 0.001). On ROC curve analysis, the optimal OSTA score cut-off value of -5.4 was associated with 73.8% sensitivity and 80.9% specificity for diagnosis of osteoporosis (area under the curve: 0.842). A decrease in the OSTA index by 1 unit was associated with a 7.3% increase in the probability of osteoporosis. Conclusions: OSTA is a potentially useful tool for screening osteoporosis in patients undergoing hip surgery. Our findings may help identify high-risk patients who require further investigation using DXA.

2.
J Arthroplasty ; 2024 May 11.
Article in English | MEDLINE | ID: mdl-38735547

ABSTRACT

BACKGROUND: Periprosthetic femoral fractures (PFFs) are serious complications in hip arthroplasty for femoral neck fractures. The rates of intraoperative (iPFFs) and postoperative PFFs (pPFFs) are higher in cementless stem cases than in cemented cases. This study aimed to investigate the effects of cerclage cabling on PFF prevention in cementless arthroplasty for femoral neck fractures. METHODS: This retrospective study included 329 consecutive patients who underwent hip arthroplasty using a cementless stem for femoral neck fractures. A total of 159 and 170 patients were in the non-cabling and cabling groups, respectively. Patient characteristics were comparable in both groups. The PFF occurrence (iPFF and pPFF) rates, reoperation rates, operative time, and blood loss volume were compared between the groups. RESULTS: The iPFF rate was significantly higher in the noncabling group (6.3%) than in the cabling group (0%, P < .001). The rate of pPFF was significantly higher in the non-cabling group (5.1%) than in the cabling group (0.6%; P = .016). All patients in the non-cabling group required reoperation (5.1%), whereas the patient in the cabling group was an ambulatory case and required no reoperation (0%, P = .003). No significant difference in either operative time or blood loss volume was observed between the non-cabling (50 minutes, 133 mL) and cabling (52 minutes, P = .244; 149 mL, P = .212, respectively) groups. CONCLUSIONS: When a cementless stem is used to treat unstable femoral neck fractures, cerclage cabling effectively prevents iPPF and pPPF without increasing surgical time or blood loss volume.

3.
Cureus ; 16(3): e56402, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38633935

ABSTRACT

Introduction Recently, large-scale language models, such as ChatGPT (OpenAI, San Francisco, CA), have evolved. These models are designed to think and act like humans and possess a broad range of specialized knowledge. GPT-3.5 was reported to be at a level of passing the United States Medical Licensing Examination. Its capabilities continue to evolve, and in October 2023, GPT-4V became available as a model capable of image recognition. Therefore, it is important to know the current performance of these models because they will be soon incorporated into medical practice. We aimed to evaluate the performance of ChatGPT in the field of orthopedic surgery. Methods We used three years' worth of Japanese Board of Orthopaedic Surgery Examinations (JBOSE) conducted in 2021, 2022, and 2023. Questions and their multiple-choice answers were used in their original Japanese form, as was the official examination rubric. We inputted these questions into three versions of ChatGPT: GPT-3.5, GPT-4, and GPT-4V. For image-based questions, we inputted only textual statements for GPT-3.5 and GPT-4, and both image and textual statements for GPT-4V. As the minimum scoring rate acquired to pass is not officially disclosed, it was calculated using publicly available data. Results The estimated minimum scoring rate acquired to pass was calculated as 50.1% (43.7-53.8%). For GPT-4, even when answering all questions, including the image-based ones, the percentage of correct answers was 59% (55-61%) and GPT-4 was able to achieve the passing line. When excluding image-based questions, the score reached 67% (63-73%). For GPT-3.5, the percentage was limited to 30% (28-32%), and this version could not pass the examination. There was a significant difference in the performance between GPT-4 and GPT-3.5 (p < 0.001). For image-based questions, the percentage of correct answers was 25% in GPT-3.5, 38% in GPT-4, and 38% in GPT-4V. There was no significant difference in the performance for image-based questions between GPT-4 and GPT-4V. Conclusions ChatGPT had enough performance to pass the orthopedic specialist examination. After adding further training data such as images, ChatGPT is expected to be applied to the orthopedics field.

4.
Bone Joint J ; 106-B(3 Supple A): 104-109, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38425294

ABSTRACT

Aims: Femoral component anteversion is an important factor in the success of total hip arthroplasty (THA). This retrospective study aimed to investigate the accuracy of femoral component anteversion with the Mako THA system and software using the Exeter cemented femoral component, compared to the Accolade II cementless femoral component. Methods: We reviewed the data of 30 hips from 24 patients who underwent THA using the posterior approach with Exeter femoral components, and 30 hips from 24 patients with Accolade II components. Both groups did not differ significantly in age, sex, BMI, bone quality, or disease. Two weeks postoperatively, CT images were obtained to measure acetabular and femoral component anteversion. Results: The mean difference in femoral component anteversion between intraoperative and postoperative CT measurements (system accuracy of component anteversion) was 0.8° (SD 1.8°) in the Exeter group and 2.1° (SD 2.3°) in the Accolade II group, respectively (p = 0.020). The mean difference in anteversion between the plan and the postoperative CT measurements (clinical accuracy of femoral component anteversion) was 1.2° (SD 3.6°) in the Exeter group, and 4.2° (SD 3.9°) in the Accolade II group (p = 0.003). No significant differences were found in acetabular component inclination and anteversion; however, the clinical accuracy of combined anteversion was significantly better in the Exeter group (0.6° (SD 3.9°)) than the Accolade II group (3.6° (SD 4.1°)). Conclusion: The Mako THA system and software helps surgeons control the femoral component anteversion to achieve the target angle of insertion. The Exeter femoral component, inserted using Mako THA system, showed greater precision for femoral component and combined component anteversion than the Accolade II component.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Robotic Surgical Procedures , Humans , Acetabulum/diagnostic imaging , Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Retrospective Studies , Tomography, X-Ray Computed , Male , Female
5.
Int J Comput Assist Radiol Surg ; 19(5): 903-915, 2024 May.
Article in English | MEDLINE | ID: mdl-38472690

ABSTRACT

PURPOSE: Progression of hip osteoarthritis (hip OA) leads to pain and disability, likely leading to surgical treatment such as hip arthroplasty at the terminal stage. The severity of hip OA is often classified using the Crowe and Kellgren-Lawrence (KL) classifications. However, as the classification is subjective, we aimed to develop an automated approach to classify the disease severity based on the two grades using digitally-reconstructed radiographs from CT images. METHODS: Automatic grading of the hip OA severity was performed using deep learning-based models. The models were trained to predict the disease grade using two grading schemes, i.e., predicting the Crowe and KL grades separately, and predicting a new ordinal label combining both grades and representing the disease progression of hip OA. The models were trained in classification and regression settings. In addition, the model uncertainty was estimated and validated as a predictor of classification accuracy. The models were trained and validated on a database of 197 hip OA patients, and externally validated on 52 patients. The model accuracy was evaluated using exact class accuracy (ECA), one-neighbor class accuracy (ONCA), and balanced accuracy. RESULTS: The deep learning models produced a comparable accuracy of approximately 0.65 (ECA) and 0.95 (ONCA) in the classification and regression settings. The model uncertainty was significantly larger in cases with large classification errors ( P < 6 e - 3 ). CONCLUSIONS: In this study, an automatic approach for grading hip OA severity from CT images was developed. The models have shown comparable performance with high ONCA, which facilitates automated grading in large-scale CT databases and indicates the potential for further disease progression analysis. Classification accuracy was correlated with the model uncertainty, which would allow for the prediction of classification errors. The code will be made publicly available at https://github.com/NAIST-ICB/HipOA-Grading .


Subject(s)
Deep Learning , Osteoarthritis, Hip , Severity of Illness Index , Tomography, X-Ray Computed , Humans , Osteoarthritis, Hip/diagnostic imaging , Tomography, X-Ray Computed/methods , Female , Male , Aged , Middle Aged , Uncertainty , Disease Progression
6.
Bone Jt Open ; 5(2): 79-86, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38295838

ABSTRACT

Aims: This study aimed to investigate the incidence of ≥ 5 mm asymmetry in lower and whole leg lengths (LLs) in patients with unilateral osteoarthritis (OA) secondary to developmental dysplasia of the hip (DDH-OA) and primary hip osteoarthritis (PHOA), and the relationship between lower and whole LL asymmetries and femoral length asymmetry. Methods: In total, 116 patients who underwent unilateral total hip arthroplasty were included in this study. Of these, 93 had DDH-OA and 23 had PHOA. Patients with DDH-OA were categorized into three groups: Crowe grade I, II/III, and IV. Anatomical femoral length, femoral length greater trochanter (GT), femoral length lesser trochanter (LT), tibial length, foot height, lower LL, and whole LL were evaluated using preoperative CT data of the whole leg in the supine position. Asymmetry was evaluated in the Crowe I, II/III, IV, and PHOA groups. Results: The incidences of whole and lower LL asymmetries were 40%, 62.5%, 66.7%, and 26.1%, and 21.7%, 20.8%, 55.6%, and 8.7% in the Crowe I, II/III, and IV, and PHOA groups, respectively. The incidence of tibial length asymmetry was significantly higher in the Crowe IV group (44.4%) than that in the PHOA group (4.4%). In all, 50% of patients with DDH-OA with femoral length GT and LT asymmetries had lower LL asymmetry, and 75% had whole LL asymmetry. The incidences of lower and whole LL asymmetries were 20% and 42.9%, respectively, even in the absence of femoral length GT and LT asymmetries. Conclusion: Overall, 43% of patients with unilateral DDH-OA without femoral length asymmetry had whole LL asymmetry of ≥ 5 mm. Thus, both the femur length and whole LL should be measured to accurately assess LL discrepancy in patients with unilateral DDH-OA.

7.
Article in English | MEDLINE | ID: mdl-38282095

ABSTRACT

PURPOSE: Manual annotations for training deep learning models in auto-segmentation are time-intensive. This study introduces a hybrid representation-enhanced sampling strategy that integrates both density and diversity criteria within an uncertainty-based Bayesian active learning (BAL) framework to reduce annotation efforts by selecting the most informative training samples. METHODS: The experiments are performed on two lower extremity datasets of MRI and CT images, focusing on the segmentation of the femur, pelvis, sacrum, quadriceps femoris, hamstrings, adductors, sartorius, and iliopsoas, utilizing a U-net-based BAL framework. Our method selects uncertain samples with high density and diversity for manual revision, optimizing for maximal similarity to unlabeled instances and minimal similarity to existing training data. We assess the accuracy and efficiency using dice and a proposed metric called reduced annotation cost (RAC), respectively. We further evaluate the impact of various acquisition rules on BAL performance and design an ablation study for effectiveness estimation. RESULTS: In MRI and CT datasets, our method was superior or comparable to existing ones, achieving a 0.8% dice and 1.0% RAC increase in CT (statistically significant), and a 0.8% dice and 1.1% RAC increase in MRI (not statistically significant) in volume-wise acquisition. Our ablation study indicates that combining density and diversity criteria enhances the efficiency of BAL in musculoskeletal segmentation compared to using either criterion alone. CONCLUSION: Our sampling method is proven efficient in reducing annotation costs in image segmentation tasks. The combination of the proposed method and our BAL framework provides a semi-automatic way for efficient annotation of medical image datasets.

8.
J Artif Organs ; 2024 Jan 10.
Article in English | MEDLINE | ID: mdl-38195733

ABSTRACT

Research is lacking on the effect of intraoperative pelvic tracker displacement relative to the pelvis on cup orientation accuracy in computed tomography (CT)-based navigation (CTN) or multivariable analysis to detect factors associated with CTN accuracy. Here, we asked: (1) how pelvic tracker displacement influences the CTN accuracy of cup orientation in total hip arthroplasty (THA)? and (2) what factors are associated with CTN accuracy on multivariable analysis? Regarding cup orientation in 446 THA procedures using CTN, we evaluated clinical error defined as the difference between postoperative measurement and preoperative planning and measurement error defined as the difference between postoperative and intraoperative measurements. Multivariable regression analyses detected the associated factors. Subjects with an intraoperative tracker displacement of < 2 mm were classified in the verified group. Mean absolute clinical and measurement errors were < 1.5° in the verified group, whereas the measurement error of 2.6° for cup inclination and 1.3° for anteversion was larger in the non-verified versus verified group. Tracker displacement and screw fixation were associated with larger clinical errors, while tracker displacement and surgeon inexperience were associated with larger measurement errors. Clinical and measurement accuracies were high for CTN cup placement with rigid pelvic tracker fixation.

9.
J Bone Miner Metab ; 42(1): 37-46, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38057601

ABSTRACT

INTRODUCTION: Forearm dual-energy X-ray absorptiometry (DXA) is often performed in clinics where central DXA is unavailable. Accurate bone mineral density (BMD) measurement is crucial for clinical assessment. Forearm rotation can affect BMD measurements, but this effect remains uncertain. Thus, we aimed to conduct a simulation study using CT images to clarify the effect of forearm rotation on BMD measurements. MATERIALS AND METHODS: Forearm CT images of 60 women were analyzed. BMD was measured at the total, ultra-distal (UD), mid-distal (MD), and distal 33% radius regions with the radius located at the neutral position using digitally reconstructed radiographs generated from CT images. Then, the rotation was altered from - 30° to 30° (supination set as positive) with a one-degree increment, and the percent BMD changes from the neutral position were quantified for all regions at each angle for each patient. RESULTS: The maximum mean BMD changes were 5.8%, 7.0%, 6.2%, and 7.2% for the total, UD, MD, and distal 33% radius regions, respectively. The analysis of the absolute values of the percent BMD changes from the neutral position showed that BMD changes of all patients remained within 2% when the rotation was between - 5° and 7° for the total region, between - 3° and 2° for the UD region, between - 4° and 3° for the MD region, and between - 3° and 1° for the distal 33% radius region. CONCLUSION: Subtle rotational changes affected the BMD measurement of each region. The results showed the importance of forearm positioning when measuring the distal radius BMD.


Subject(s)
Forearm , Radius , Humans , Female , Forearm/diagnostic imaging , Radius/diagnostic imaging , Bone Density , Absorptiometry, Photon/methods
10.
J Orthop Res ; 42(2): 474-483, 2024 02.
Article in English | MEDLINE | ID: mdl-37728980

ABSTRACT

A carbon fiber-reinforced polyetheretherketone (CFR/PEEK) hip stem with a special antibiotic elution mechanism is under development to treat periprosthetic joint infection (PJI). The antibiotic elution characteristics of intramedullary implants were experimentally investigated, and the efficacy of revision surgery using a therapeutic stem in treating ovine PJI was examined. To evaluate elution characteristics, the intramedullary vancomycin-loaded CFR/PEEK cylindrical implants were inserted in the distal femur of nine sheep, and the vancomycin elution rate was measured at 2, 7, and 21 days. To evaluate therapeutic efficacy, the PJI model with staphylococcus aureus was attempted to create for five sheep. Moreover, the therapeutic vancomycin-loaded CFR/PEEK stem was implanted during one-stage revision surgery. Three weeks after revision surgery, the treatment efficacy was evaluated based on bacterial cultures and wound findings. In addition, the vancomycin elution rate from the stem was measured. On average, the cylindrical implants eluted approximately 70% vancomycin in 21 days. Of the five sheep attempting to create a PJI model, three were successfully infected with S. aureus as intended for verification of treatment efficacy. In all three joints, negative bacterial cultures and no purulence were observed 3 weeks after revision surgery. The vancomycin elution rates from the stems were >70%. Efficient elution of vancomycin was confirmed by the experimental implant inserted into the bone marrow and the stem in actual PJI treatment. Using a novel therapeutic stem with an antibiotic elution mechanism in one-stage revision surgery, successful treatment was demonstrated in all S. aureus-induced PJIs.


Subject(s)
Arthritis, Infectious , Prosthesis-Related Infections , Animals , Sheep , Vancomycin/therapeutic use , Carbon Fiber/therapeutic use , Pilot Projects , Staphylococcus aureus , Prosthesis-Related Infections/drug therapy , Prosthesis-Related Infections/microbiology , Polyethylene Glycols/therapeutic use , Anti-Bacterial Agents/therapeutic use , Ketones/therapeutic use , Arthritis, Infectious/drug therapy , Retrospective Studies , Reoperation
11.
J Orthop Res ; 2023 Dec 12.
Article in English | MEDLINE | ID: mdl-38084832

ABSTRACT

To avoid dislocation after total hip arthroplasty, it is desirable to avoid implant impingement during activities of daily living. Numerous simulation studies have been performed at 30° of internal rotation (IR) with 90° of flexion. However, these studies may not reflect the impingement that occurs during activities such as floor sitting, which require a larger IR during flexion. The purpose of this study was to assess the impact of varying IR angles during flexion on the impingement-free safe zone and optimal stem anteversion. In this study, implant impingement simulation was evaluated in computer simulation. The prosthesis used a flat liner, and a 32- or 40-mm femoral head and stem. Three patterns of required IR angle (30° IR/40° IR/50° IR with 90° flexion) combined with 13 directions of the required range of motion were simulated. The optimal stem anteversion to maximize the safe zone was analyzed. Increasing the required IR at 90° flexion decreased the safe zone, particularly with small stem anteversion angles. With a 32-mm head, the desirable stem anteversion at 40° of cup inclination was 15°/25°/35° in required 30° IR/40° IR/50° IR with 90° flexion, respectively. The safe zone area of the 32-mm head was smaller than that of the 40-mm head. For patients who require a larger IR with 90° flexion, the stem and cup target anteversion should be adjusted according to the implant design, head diameter, and patient's required IR at flexion in their lifestyle.

12.
Mod Rheumatol ; 2023 Oct 07.
Article in English | MEDLINE | ID: mdl-37804206

ABSTRACT

OBJECTIVES: Systemic steroid administration has been suggested for the treatment of coronavirus disease 2019 (COVID-19), but the occurrence of osteonecrosis of the femoral head (ONFH) was one of the concerns for this treatment. This study aimed to use magnetic resonance imaging (MRI) to assess the incidence of ONFH after treatment COVID-19. METHODS: The study included 41 patients who were hospitalized and treated for pneumonia or other COVID-19-induced diseases. We conducted interviews with these patients regarding hip pain and performed MRI screenings for ONFH. The incidence and timing of ONFH after COVID-19 treatment were investigated. RESULTS: Of the 41 patients, one died of pneumonia, and the remaining patients did not complain of hip pain. MRI screening of 26 patients was performed, and asymptomatic ONFH was detected in one patient (3.8%) whose ONFH appeared 1 month after the COVID-19 infection. CONCLUSION: Our MRI screening of ONFH in post-COVID-19 patients revealed asymptomatic ONFH, which would not have been identified without active screening. Physicians should be aware that ONFH may occur in patients after treating COVID-19.

13.
Med Image Anal ; 90: 102970, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37774535

ABSTRACT

Osteoporosis is a prevalent bone disease that causes fractures in fragile bones, leading to a decline in daily living activities. Dual-energy X-ray absorptiometry (DXA) and quantitative computed tomography (QCT) are highly accurate for diagnosing osteoporosis; however, these modalities require special equipment and scan protocols. To frequently monitor bone health, low-cost, low-dose, and ubiquitously available diagnostic methods are highly anticipated. In this study, we aim to perform bone mineral density (BMD) estimation from a plain X-ray image for opportunistic screening, which is potentially useful for early diagnosis. Existing methods have used multi-stage approaches consisting of extraction of the region of interest and simple regression to estimate BMD, which require a large amount of training data. Therefore, we propose an efficient method that learns decomposition into projections of bone-segmented QCT for BMD estimation under limited datasets. The proposed method achieved high accuracy in BMD estimation, where Pearson correlation coefficients of 0.880 and 0.920 were observed for DXA-measured BMD and QCT-measured BMD estimation tasks, respectively, and the root mean square of the coefficient of variation values were 3.27 to 3.79% for four measurements with different poses. Furthermore, we conducted extensive validation experiments, including multi-pose, uncalibrated-CT, and compression experiments toward actual application in routine clinical practice.

14.
Bone Joint Res ; 12(9): 590-597, 2023 Sep 20.
Article in English | MEDLINE | ID: mdl-37728034

ABSTRACT

Aims: This study aimed to develop and validate a fully automated system that quantifies proximal femoral bone mineral density (BMD) from CT images. Methods: The study analyzed 978 pairs of hip CT and dual-energy X-ray absorptiometry (DXA) measurements of the proximal femur (DXA-BMD) collected from three institutions. From the CT images, the femur and a calibration phantom were automatically segmented using previously trained deep-learning models. The Hounsfield units of each voxel were converted into density (mg/cm3). Then, a deep-learning model trained by manual landmark selection of 315 cases was developed to select the landmarks at the proximal femur to rotate the CT volume to the neutral position. Finally, the CT volume of the femur was projected onto the coronal plane, and the areal BMD of the proximal femur (CT-aBMD) was quantified. CT-aBMD correlated to DXA-BMD, and a receiver operating characteristic (ROC) analysis quantified the accuracy in diagnosing osteoporosis. Results: CT-aBMD was successfully measured in 976/978 hips (99.8%). A significant correlation was found between CT-aBMD and DXA-BMD (r = 0.941; p < 0.001). In the ROC analysis, the area under the curve to diagnose osteoporosis was 0.976. The diagnostic sensitivity and specificity were 88.9% and 96%, respectively, with the cutoff set at 0.625 g/cm2. Conclusion: Accurate DXA-BMD measurements and diagnosis of osteoporosis were performed from CT images using the system developed herein. As the models are open-source, clinicians can use the proposed system to screen osteoporosis and determine the surgical strategy for hip surgery.

15.
J Artif Organs ; 2023 Jun 02.
Article in English | MEDLINE | ID: mdl-37266841

ABSTRACT

Periprosthetic joint infection (PJI) is a catastrophic complication after total hip arthroplasty. A new drug-loaded carbon fiber-reinforced polymer (CFRP) prosthesis with a sustained drug-release mechanism is being developed for one-stage surgery. We aimed to examine the diffusion dynamics of vancomycin from vancomycin paste-loaded CFRP implants. The differences in the in vitro diffusion dynamics of vancomycin paste were investigated using the elution test by varying parameters. These included the mixing ratio of vancomycin and distilled water (1:0.8, 1:1.2, and 1:1.4) for vancomycin paste, and hole diameter (1 mm and 2 mm) on the container. The in vivo diffusion dynamics were investigated using a rabbit model with vancomycin-loaded CFRP implants placed subcutaneously. The in vitro experiments showed that the diffusion effect of vancomycin was highest in the parameters of vancomycin paste with distilled water mixed in a ratio of 1:1.4, and with a 2 mm hole diameter. The in vivo experiments revealed diffusion dynamics similar to those observed in the in vitro study. The drug diffusion effect tended to be high for vancomycin paste with a large water ratio, and a large diameter of holes. These results indicate that the drug diffusion dynamics from a CFRP implant with holes can be adjusted by varying the water ratio of the vancomycin paste, and the hole size on the CFRP implant.

17.
Sci Rep ; 13(1): 8482, 2023 05 25.
Article in English | MEDLINE | ID: mdl-37231008

ABSTRACT

This paper presents methods of decomposition of musculoskeletal structures from radiographs into multiple individual muscle and bone structures. While existing solutions require dual-energy scan for the training dataset and are mainly applied to structures with high-intensity contrast, such as bones, we focused on multiple superimposed muscles with subtle contrast in addition to bones. The decomposition problem is formulated as an image translation problem between (1) a real X-ray image and (2) multiple digitally reconstructed radiographs, each of which contains a single muscle or bone structure, and solved using unpaired training based on the CycleGAN framework. The training dataset was created via automatic computed tomography (CT) segmentation of muscle/bone regions and virtually projecting them with geometric parameters similar to the real X-ray images. Two additional features were incorporated into the CycleGAN framework to achieve a high-resolution and accurate decomposition: hierarchical learning and reconstruction loss with the gradient correlation similarity metric. Furthermore, we introduced a new diagnostic metric for muscle asymmetry directly measured from a plain X-ray image to validate the proposed method. Our simulation and real-image experiments using real X-ray and CT images of 475 patients with hip diseases suggested that each additional feature significantly enhanced the decomposition accuracy. The experiments also evaluated the accuracy of muscle volume ratio measurement, which suggested a potential application to muscle asymmetry assessment from an X-ray image for diagnostic and therapeutic assistance. The improved CycleGAN framework can be applied for investigating the decomposition of musculoskeletal structures from single radiographs.


Subject(s)
Algorithms , Deep Learning , Humans , Image Processing, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Bone and Bones
18.
Arch Osteoporos ; 18(1): 35, 2023 02 24.
Article in English | MEDLINE | ID: mdl-36826629

ABSTRACT

The patient's position may affect the bone mineral density (BMD) measurements; however, the extent of this effect is undefined. This CT image-based simulation study quantified changes in BMD induced by hip flexion, adduction, and rotations to recommend appropriate patient positioning when acquiring dual-energy x-ray absorptiometry images. PURPOSE: Several studies have analyzed the effect of hip rotation on the measurement of bone mineral density (BMD) of the proximal femur by dual-energy x-ray absorptiometry (DXA). However, as the effects of hip flexion and abduction on BMD measurements remain uncertain, a computational simulation study using CT images was performed in this study. METHODS: Hip CT images of 120 patients (33 men and 87 women; mean age, 82.1 ± 9.4 years) were used for analysis. Digitally reconstructed radiographs of the proximal femur region were generated from CT images to calculate the BMD of the proximal femur region. BMD at the neutral position was quantified, and the percent changes in BMD when hip internal rotation was altered from -30° to 15°, when hip flexion was altered from 0° to 30°, and when hip abduction was altered from -15° to 30° were quantified. Analyses were automatically performed with a 1° increment in each direction using computer programming. RESULTS: The alteration of hip angles in each direction affected BMD measurements, with the largest changes found for hip flexion (maximum change of 17.7% at 30° flexion) and the smallest changes found for hip rotation (maximum change of 2.2% at 15° internal rotation). The BMD measurements increased by 0.34% for each 1° of hip abduction, and the maximum change was 12.3% at 30° abduction. CONCLUSION: This simulation study quantified the amount of BMD change induced by altering the hip position. Based on these results, we recommend that patients be positioned carefully when acquiring DXA images.


Subject(s)
Bone Density , Femur , Male , Humans , Female , Aged , Aged, 80 and over , Absorptiometry, Photon/methods , Tomography, X-Ray Computed/methods , Patient Positioning
19.
J Biomech ; 146: 111424, 2023 01.
Article in English | MEDLINE | ID: mdl-36603366

ABSTRACT

Femoroacetabular impingement syndrome (FAIS) is a motion-related pathology of the hip characterized by pain, morphological abnormalities of the proximal femur, and an elevated risk of joint deterioration and hip osteoarthritis. Activities that require deep flexion are understood to induce impingement in cam FAIS patients, however, less demanding activities such as walking and pivoting may induce pain as well as alterations in kinematics and joint stability. Still, the paucity of quantitative descriptions of cam FAIS has hindered understanding underlying hip joint mechanics during such activities. Previous in silico studies have employed generalized model geometry or kinematics to simulate impingement between the femur and acetabulum, which may not accurately capture the interplay between morphology and motion. In this study, we utilized models with participant-specific bone and articular soft tissue anatomy and kinematics measured by dual-fluoroscopy to compare hip contact mechanics of cam FAIS patients to controls during four activities of daily living (internal/external pivoting and level/incline walking). Averaged across the gait cycle during incline walking, patients displayed increased strain in the anterior joint (labrum strain: p-value = 0.038, patients: 11.7 ± 6.7 %, controls: 5.0 ± 3.6 %; cartilage strain: p-value = 0.029, patients: 9.1 ± 3.3 %, controls: 4.2 ± 2.3). Patients also exhibited increased average anterior cartilage strains during external pivoting (p-value = 0.039; patients: 13.0 ± 9.2 %, controls: 3.9 ± 3.2 %]). No significant differences between patient and control contact area and strain were found for level walking and internal pivoting. Our study provides new insights into the biomechanics of cam FAIS, including spatiotemporal hip joint contact mechanics during activities of daily living.


Subject(s)
Femoracetabular Impingement , Humans , Activities of Daily Living , Hip Joint , Acetabulum , Walking , Cartilage , Pain
20.
Arch Osteoporos ; 18(1): 22, 2023 01 21.
Article in English | MEDLINE | ID: mdl-36680601

ABSTRACT

This study developed a system to quantify the lumbar spine's bone mineral density (BMD) in two and three dimensions for osteoporosis screening using quantitative CT images. Measuring the two-dimensional BMD could reproduce the BMD measurement performed in dual-energy X-ray absorptiometry, and an accurate diagnosis of osteoporosis was possible. PURPOSE: To date, the assessment of bone mineral density (BMD) using CT images has been made in three dimensions, leading to errors in detecting osteoporosis based on the two-dimensional assessments of BMD using dual-energy X-ray absorptiometry (DXA-BMD). Herein, we aimed to develop a system that measures two- and three-dimensional lumbar BMD from quantitative CT images and validated the accuracy of the system in diagnosing osteoporosis with regard to the DXA classification. METHODS: Fifty-nine pairs of spinal CT and DXA images were analyzed. First, the three-dimensional BMD was measured at the axial slice of the L1 vertebra on CT images (L1-vBMD). Then, the L1-L4 vertebrae were segmented from the CT images to measure the three-dimensional BMD at the trabecular region of the L1-L4 vertebral bodies (CT-vBMD). Lastly, the segmented vertebrae were projected onto the coronal plane to measure the two-dimensional BMD (CT-aBMD). Each parameter was correlated with DXA-BMD, and the receiver operating characteristic (ROC) curve to diagnose osteoporosis was assessed. RESULTS: The correlation coefficients of DXA-BMD with L1-vBMD, CT-vBMD, and CT-aBMD were 0.364, 0.456, and 0.911, respectively (all p < 0.01). In the ROC curve analysis to diagnose osteoporosis, the area under the curve for CT-aBMD (0.941) was significantly higher than those for L1-vBMD (0.582) and CT-vBMD (0.657) (both p < 0.01). CONCLUSION: Compared with L1-vBMD and CT-vBMD, CT-aBMD could accurately predict DXA-BMD and detect patients with osteoporosis. Given that our method can quantify BMD in both two and three dimensions, it could be used to screen for osteoporosis from quantitative CT images.


Subject(s)
Bone Density , Osteoporosis , Humans , Lumbar Vertebrae/diagnostic imaging , Tomography, X-Ray Computed/methods , Osteoporosis/diagnostic imaging , Absorptiometry, Photon/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...