1.
Article in English | MEDLINE | ID: mdl-35564983

ABSTRACT

Recently, an occlusal force-measuring device with a capacitive-type pressure-mapping sensor (OFMD-CPS) was developed. We aimed to establish age- and sex-specific standard values for OFMD-CPS-measured occlusal force (OF) and to assess the concurrent validity of the OFMD against another OF measuring system with a pressure-sensitive sheet (Dental Prescale II). Using data from a population-based study, we calculated the OFMD-CPS-measured OF means and deciles in 5-year age groups for each sex. The OFMD-CPS-measured OF was validated against the Dental Prescale II-measured OF with Spearman correlation coefficients. Furthermore, we calculated the area under the receiver operating characteristic curve (AUC) against the preexisting Dental Prescale II-measured OF cutoff value of 350 N. In total, 596 individuals (236 men and 360 women) with a mean (standard deviation (SD)) age of 73.7 (6.7) years were included in the analyses. The mean (SD) OFMD-CPS-measured OFs were 581.6 (284.6) N in men and 446.9 (209.9) N in women. There was a strong positive correlation (Spearman's Rho = 0.73) between OFMD-CPS-measured and Dental Prescale II-measured OF. The diagnostic accuracy of the OFMD-CPS-measured OF for the Dental Prescale II-measured OF cutoff value was high (AUC = 0.88). In conclusion, we demonstrated standard values and concurrent validity of OFMD-CPS-measured OF in community-dwelling older adults.


Subject(s)
Bite Force , Independent Living , Aged , Data Collection , Female , Humans , Male , ROC Curve
2.
Article in English | MEDLINE | ID: mdl-35162299

ABSTRACT

Bite force is an important indicator of masticatory performance. However, existing methods for measuring bite force are either ineffective or expensive. Hence, we developed a novel capacitive-type pressure-mapping sensor that converts mechanical forces into changes in capacitance and calculates bite force. A portable device was fabricated based on this sensor sheet, and the accuracy of the bite-force measurements provided by the device was evaluated. The sensor has a thickness of 1.6 mm and has 63 measurement points. It was inserted into a dental model, where the output value was measured and compared with that of a universal testing machine (AG-IS 100 kN). A regression equation to estimate the bite force was obtained based on the relationship between the output of the capacitive-type pressure-mapping sensor and that of the load cell of the universal testing machine. The estimated bite force from the sensor and the quadratic regression equation closely resembled the known load applied by the compression tester (R2 = 0.992). We therefore conclude that the developed sensor can measure bite force accurately and effectively. A device with a built-in capacitive-type pressure-mapping sensor can potentially be a user-friendly tool for bite-force measurements in both clinical and epidemiological settings.


Subject(s)
Bite Force , Mechanical Phenomena , Pressure