Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters











Database
Publication year range
1.
Kyobu Geka ; 77(3): 173-176, 2024 Mar.
Article in Japanese | MEDLINE | ID: mdl-38465488

ABSTRACT

A 63-year-old woman with severe aortic regurgitation was admitted to our hospital due to congestive heart failure. She also had antiphospholipid syndrome (APS), necessitating strict coagulation management. Given her history of cerebellar infarction, deep vein thrombosis, and recurrent miscarriages, her thrombosis risk was higher, with all three types of antiphospholipid antibodies testing positive. Before the surgery, we created a heparin-activated clotting time (ACT) titration curve using the patient's blood, and the calculated ACT corresponding to the target heparin concentration of 3 U/ml was 650 seconds. We planned to administer heparin according to this target during cardiopulmonary bypass. The patient underwent an aortic valve replacement (AVR) using a bioprosthesis and was discharged without complications.


Subject(s)
Antiphospholipid Syndrome , Cardiac Surgical Procedures , Heart Valve Prosthesis , Female , Humans , Middle Aged , Anticoagulants , Antiphospholipid Syndrome/complications , Heparin , Thrombosis
2.
Kyobu Geka ; 76(3): 188-192, 2023 Mar.
Article in Japanese | MEDLINE | ID: mdl-36861273

ABSTRACT

A 48-year-old man underwent computed tomography for the examination of lower back pain, which incidentally detected a cardiac tumor in the right atrium. On echocardiography, the tumor was identified as a 30 mm round mass with a thin wall and iso- and hyper-echogenic contents that originated from the atrial septum. The tumor was successfully removed under cardiopulmonary bypass, and the patient was discharged in good health. The cyst was filled with old blood, and focal calcification was observed. Pathological examination revealed that the cystic wall was composed of thin-layered fibrous tissue lined with endothelial cells. Regarding a treatment, it is reported that early surgical removal is preferable to avoid embolic complications, however it is controversial. Furthermore, it needs to discuss about the difference between fetal/neonatal and adult cases.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cysts , Adult , Male , Infant, Newborn , Humans , Middle Aged , Endothelial Cells , Heart Atria/diagnostic imaging , Heart Atria/surgery , Cysts/diagnostic imaging , Cysts/surgery
3.
Int J Implant Dent ; 7(1): 63, 2021 06 30.
Article in English | MEDLINE | ID: mdl-34189641

ABSTRACT

BACKGROUND: Recently, it has become possible to analyze implant placement position using the digital matching data of optical impression data of the oral cavity or plaster models with cone beam computed tomography (CBCT) data, and create a highly accurate surgical guide. It has been reported that CBCT measurements were smaller than the actual values, termed shrinkage. Matching of digital data is reliable when the plaster model or intraoral impression values show shrinkage at the same rate as the CBCT data. However, if the shrinkage rate is significantly different, the obtained digital data become unreliable. To clarify digital matching reliability, we examined dimensional reproducibility and shrinkage in measurements obtained with a model scanner, intra-oral scanner (iOS), and CBCT. MATERIALS AND METHODS: Three implants that were arranged in a triangle were fixed in an acrylic plate. The distance between each implants were measured using model scanner, iOS, and CBCT. The actual size measured by electronic caliper was regarded as control. RESULTS: All values measured with CBCT were significantly smaller than that of model scanner, iOS, and control (p<0.001). The model scanner shrinkage was 0.37-0.39%, iOS shrinkage was 0.9-1.4%, and CBCT shrinkage was 1.8-6.9%. There were statistically significant differences among the shrinkage with iOS, CBCT, and model scanner (p<0.001). CONCLUSION: Our findings showed that all measurements obtained with those modalities showed shrinkage as compared to the actual values. In addition, CBCT shrinkage was largest among three different measuring methods. They indicated that data matching between CBCT and scanner measurements requires attention in regard to the reliability of values obtained with those devices.


Subject(s)
Spiral Cone-Beam Computed Tomography , Cone-Beam Computed Tomography , Dentistry , Imaging, Three-Dimensional , Reproducibility of Results
4.
Gen Thorac Cardiovasc Surg ; 69(1): 14-18, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32845449

ABSTRACT

OBJECTIVES: To control intraoperative hyperglycemia in patients who underwent aortic surgery using STG-55® artificial endocrine pancreas and clarify the effectiveness of this device. METHODS: Blood glucose control using the STG-55® was performed in 18 patients (15 men and 3 women; age, 66 ± 10 years) who required hypothermic circulatory arrest (STG-55® group). Seventeen patients (10 men and 7 women; age, 71 ± 8 years) whose blood glucose was controlled using the conventional method were included in the control group. Glucose concentration was controlled with the aim of maintaining it at 150 mg/dl. RESULTS: In both groups, the blood glucose concentrations did not significantly change during the interruption of systemic perfusion; however, a sharp increase was noted immediately after reperfusion. Although the hyperglycemic status persisted after reperfusion in the control group, it was effectively suppressed in the STG-55® group (STG® vs. control group at 50 min after reperfusion: 180 ± 35 vs. 212 ± 47 mg/dl, p = 0.026) and blood glucose concentration reached the target value of 150 mg/dl at 100 min after reperfusion (STG® vs. control group: 153 ± 29 vs. 215 ± 43 mg/dl, p = 0.0008). The total administered insulin dose was 175 ± 81 U and 5 ± 3 U in the STG® and control groups, respectively (p < 0.0001). CONCLUSIONS: To treat the accelerated hyperglycemic status in aortic surgery requiring circulatory arrest, strict glycemic control using an artificial endocrine pancreas might be beneficial.


Subject(s)
Hyperglycemia , Insulin Infusion Systems , Aged , Blood Glucose , Female , Humans , Hyperglycemia/prevention & control , Insulin , Male , Middle Aged , Reperfusion
6.
Clin Case Rep ; 6(4): 606-608, 2018 04.
Article in English | MEDLINE | ID: mdl-29636923

ABSTRACT

A 65-year-old man had histories of retroperitoneal fibrosis, membranous nephropathy, and acute coronary syndrome. Chest computed tomography showed an enlarged ascending aorta and type B aortic dissection, and he underwent ascending aorta and arch replacement. A pathological examination of the resected aorta showed immunoglobulin G4-positive plasma cell infiltration.

7.
Kyobu Geka ; 70(9): 731-736, 2017 Aug.
Article in Japanese | MEDLINE | ID: mdl-28790237

ABSTRACT

Vacuum-assisted closure(VAC) therapy is mainly used for tissue defects. VAC therapy can remove exudate that could impair the healing process. We applied VAC therapy in patients considered at high risk of surgical site infection who underwent cardiovascular surgery via standard median sternotomy. Risk factors included advanced heart failure, obesity, diabetes mellitus, steroid administration, immunosuppressant administration, and chronic renal failure, etc. VAC therapy was used in 134 patients. Only 3 of these patients (2.2%) developed surgical site infection caused by Staphylococcus epidermidis;2 patients fully recovered after prolonged VAC therapy for 2 weeks, and the other required an additional sternal fixation after the sternal wires were removed for wound infection control. No patient developed infective mediastinitis. Prophylactic VAC therapy can reduce postoperative wound infection in high risk patients undergoing open heart surgery via full sternotomy.


Subject(s)
Cardiac Surgical Procedures/methods , Heart Diseases/surgery , Postoperative Complications/prevention & control , Female , Humans , Male , Mediastinitis/prevention & control , Risk Factors , Sternotomy
8.
Kyobu Geka ; 70(5): 385-388, 2017 May.
Article in Japanese | MEDLINE | ID: mdl-28496087

ABSTRACT

A sinus of Valsalva aneurysm is an uncommon cardiac anomaly. The aneurysm usually ruptures into the cardiac cavity, and rupture into the pericardial cavity is unusual. A 69-year-old man was admitted to our hospital after collapse due to cardiac tamponade. Computed tomography revealed a ruptured right sinus of Valsalva aneurysm (5 cm) with massive pericardial effusion. The right coronary artery arose from the aneurysm. Severe aortic regurgitation due to the lack of coaptation of the valves was detected by echocardiography. Emergency patch closure of the aneurysm orifice, aortic valve replacement, and coronary artery bypass grafting to the right coronary artery were performed. The postoperative course was uneventful and the patient was discharged on postoperative day 28 in good health.


Subject(s)
Aortic Aneurysm/surgery , Aortic Rupture/surgery , Sinus of Valsalva/surgery , Aged , Aortic Aneurysm/complications , Aortic Aneurysm/diagnostic imaging , Aortic Rupture/diagnostic imaging , Aortic Rupture/etiology , Humans , Imaging, Three-Dimensional , Male , Sinus of Valsalva/diagnostic imaging , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL