Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-37869412

ABSTRACT

SwissSPAD3 is the latest of a family of widefield time-gated SPAD imagers developed for fluorescence lifetime imaging (FLI) applications. Its distinctive features are (i) the ability to define shorter gates than its predecessors (width W < 1 ns), (ii) support for laser repetition rates up to at least 80 MHz and (iii) a dual-gate architecture providing an effective duty cycle of 100%. We present widefield macroscopic FLI measurements of short lifetime NIR dyes, analyzed using the phasor approach. The results are compared with those previously obtained with SwissSPAD2 and to theoretical predictions.

2.
Opt Express ; 31(13): 21935-21953, 2023 Jun 19.
Article in English | MEDLINE | ID: mdl-37381279

ABSTRACT

The overall sensitivity of frontside-illuminated, silicon single-photon avalanche diode (SPAD) arrays has often suffered from fill factor limitations. The fill factor loss can however be recovered by employing microlenses, whereby the challenges specific to SPAD arrays are represented by large pixel pitch (> 10 µm), low native fill factor (as low as ∼10%), and large size (up to 10 mm). In this work we report on the implementation of refractive microlenses by means of photoresist masters, used to fabricate molds for imprints of UV curable hybrid polymers deposited on SPAD arrays. Replications were successfully carried out for the first time, to the best of our knowledge, at wafer reticle level on different designs in the same technology and on single large SPAD arrays with very thin residual layers (∼10 µm), as needed for better efficiency at higher numerical aperture (NA > 0.25). In general, concentration factors within 15-20% of the simulation results were obtained for the smaller arrays (32×32 and 512×1), achieving for example an effective fill factor of 75.6-83.2% for a 28.5 µm pixel pitch with a native fill factor of 28%. A concentration factor up to 4.2 was measured on large 512×512 arrays with a pixel pitch of 16.38 µm and a native fill factor of 10.5%, whereas improved simulation tools could give a better estimate of the actual concentration factor. Spectral measurements were also carried out, resulting in good and uniform transmission in the visible and NIR.

3.
Biomed Opt Express ; 14(2): 703-713, 2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36874503

ABSTRACT

Diffuse correlation spectroscopy (DCS) is a promising noninvasive technique for monitoring cerebral blood flow and measuring cortex functional activation tasks. Taking multiple parallel measurements has been shown to increase sensitivity, but is not easily scalable with discrete optical detectors. Here we show that with a large 500 × 500 SPAD array and an advanced FPGA design, we achieve an SNR gain of almost 500 over single-pixel mDCS performance. The system can also be reconfigured to sacrifice SNR to decrease correlation bin width, with 400 ns resolution being demonstrated over 8000 pixels.

4.
Opt Express ; 31(26): 44295-44314, 2023 Dec 18.
Article in English | MEDLINE | ID: mdl-38178504

ABSTRACT

We report on LinoSPAD2, a single-photon camera system, comprising a 512×1 single-photon avalanche diode (SPAD) front-end and one or two FPGA-based back-ends. Digital signals generated by the SPADs are processed by the FPGA in real time, whereas the FPGA offers full reconfigurability at a very high level of granularity both in time and space domains. The LinoSPAD2 camera system can process 512 SPADs simultaneously through 256 channels, duplicated on each FPGA-based back-end, with a bank of 64 time-to-digital converters (TDCs) operating at 133 MSa/s, whereas each TDC has a time resolution of 20 ps (LSB). To the best of our knowledge, LinoSPAD2 is the first fully reconfigurable SPAD camera system of large format. The SPAD front-end features a pitch of 26.2 µm, a native fill factor of 25.1%, and a microlens array achieving 2.3× concentration factor. At room temperature, the median dark count rate (DCR) is 80 cps at 7 V excess bias, the peak photon detection probability (PDP) is 53% at 520 nm wavelength, and the single-photon timing resolution (SPTR) is 50 ps FWHM. The instrument response function (IRF) is around 100 ps FWHM at system level. The LinoSPAD2 camera system is suitable for numerous applications, including LiDAR imaging, heralded spectroscopy, compressive Raman sensing, and other computational imaging techniques.

5.
Article in English | MEDLINE | ID: mdl-31156324

ABSTRACT

We report on SwissSPAD2, an image sensor with 512×512 photon-counting pixels, each comprising a single-photon avalanche diode (SPAD), a 1-bit memory, and a gating mechanism capable of turning the SPAD on and off, with a skew of 250ps and 344ps, respectively, for a minimum duration of 5.75ns. The sensor is designed to achieve a frame rate of up to 97,700 binary frames per second and sub-40ps gate shifts. By synchronizing it with a pulsed laser and using multiple successive overlapping gates, one can reconstruct a molecule's fluorescent response with picosecond temporal resolution. Thanks to the sensor's number of pixels (the largest to date) and the fully integrated gated operation, SwissSPAD2 enables widefield FLIM with an all-solid-state solution and at relatively high frame rates. This was demonstrated with preliminary results on organic dyes and semiconductor quantum dots using both decay fitting and phasor analysis. Furthermore, pixels with an exceptionally low dark count rate and high photon detection probability enable uniform and high quality imaging of biologically relevant fluorescent samples stained with multiple dyes. While future versions will feature the addition of microlenses and optimize firmware speed, our results open the way to low-cost alternatives to commercially available scientific time-resolved imagers.

SELECTION OF CITATIONS
SEARCH DETAIL