Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Bone Miner Metab ; 39(4): 700-711, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33821304

ABSTRACT

INTRODUCTION: Atypical femoral fractures (AFFs) have been correlated with long-term use of bisphosphonates (BPs), glucocorticoids (GCs), and femoral geometry. We investigated the incidence and characteristics of subtrochanteric (ST) and diaphyseal (DP) AFFs in all institutes in a super-aging prefectural area. MATERIALS AND METHODS: We performed a blinded analysis of radiographic data in 87 patients with 98 AFFs in all institutes in Yamagata prefectural area from 2009 to 2014. Among the 98 AFFs, 57 AFFs comprising 11 ST fractures in 9 patients and 46 DP fractures in 41 patients with adequate medical records and X-rays were surveyed for time to bone healing and geometry. RESULTS: Of the 87 patients, 67 received BPs/denosumab (77%) and 10 received GCs (11%). Surgery was performed in 94 AFFs. Among 4 AFFs with conservative therapy, 3 required additional surgery. In univariate regression analyses for ST group versus DP group, male-to-female ratio was 2/7 versus 1/40, mean age at fracture was 58.2 (37-75) versus 78 (60-89) years, rheumatic diseases affected 55.5% (5/9) versus 4.9% (2/41), femoral lateral bowing angle was 1.7 (0-6) versus 11.8 (0.8-24)°, GC usage was 67% (6/9) versus 4.9% (2/41), and bone healing time was 12.1 (6-20) versus 8.1 (3-38) months (p < 0.05). In multivariate analyses, higher male-to-female ratio, younger age, greater proportion affected by rheumatic diseases, and higher GC usage remained significant (p < 0.05). CONCLUSIONS: The incidence of AFFs in our prefectural area was 1.43 cases/100,000 persons/year. This study suggests that the onset of ST AFFs have greater correlation with the worse bone quality, vice versa, the onset of DP AFFs correlated with the bone geometry. The developmental mechanisms of AFFs may differ significantly between ST and DP fractures.


Subject(s)
Aging/pathology , Diaphyses/pathology , Femoral Fractures/epidemiology , Hip Fractures/epidemiology , Aged , Aged, 80 and over , Female , Femoral Fractures/diagnostic imaging , Hip Fractures/diagnostic imaging , Humans , Incidence , Japan/epidemiology , Male , Middle Aged , Multivariate Analysis , Regression Analysis , Risk Factors
2.
Org Lett ; 22(13): 5046-5050, 2020 07 02.
Article in English | MEDLINE | ID: mdl-32551701

ABSTRACT

A formal synthesis of (-)-haliclonin A, isolated from the marine sponge Haliclona sp. in Korea, is described. The key feature of the synthesis includes the highly stereoselective tandem radical reaction to construct the azabicyclo[3.3.1]nonane core and the enantioselective formation of an all-carbon quaternary center via the Pd-mediated deracemization.

3.
Chirality ; 32(3): 273-281, 2020 03.
Article in English | MEDLINE | ID: mdl-31957912

ABSTRACT

Enantioselective formation of cyclohexene derivatives bearing an all-carbon quaternary stereogenic center is described. The racemic cyclohexenes are readily transformed to chiral substituted cyclohexenes in good yield with excellent enantioselectivity and diastereoselectivity by a palladium-mediated deracemization. The resulting products are promising synthetic intermediates of biologically active natural products. This protocol provides us with a new entry to the concise and scalable synthesis of multifunctionalized compounds.

4.
Tohoku J Exp Med ; 242(4): 327-334, 2017 08.
Article in English | MEDLINE | ID: mdl-28883214

ABSTRACT

Atypical femoral fractures (AFFs) have been reported to occur with minimal or spontaneous subtrochanteric and femoral shaft fractures with a characteristic transverse pattern, compared with typical femoral fractures in young patients with high-energy trauma. AFFs are related to long-term use of bisphosphonates (BPs), glucocorticoids and rheumatic diseases. We have estimated a blind analysis of AFFs in rheumatic patients receiving BPs and glucocorticoids ordinary over a long time in all Yamagata prefectural area through radiographic examination. The 123 AFFs including suspected cases over six years were collected and reviewed by two independent orthopedic surgeons. We found 86 patients with a total of 99 AFFs between 2009 and 2014 (1.43 cases/100,000 person/year). Of these 99 AFFs, 11 were in 8 rheumatic patients including three patients with bilateral AFFs. The incidence of AFFs in rheumatic patients had trend to increase from 2012. The mean age of all 8 patients was 54.9 years. All 8 patients received BPs and 7/8 received prednisolone (PSL). The mean dose of PSL was 14 mg/day. Compared to patients with unilateral AFFs, those with bilateral AFFs in rheumatic patients were on a higher dose of PSL (20 mg/day vs. 7 mg/day) and had less femoral neck-shaft angle (129° vs. 136°, p < 0.05). In conclusion, the incidence of AFFs in rheumatic patients showed a trend to increase from 2012 to 2014 in Yamagata prefecture. Careful management of AFFs is of particular importance in rheumatic patients who have taken high doses of PSL and have small femoral neck-shaft angle.


Subject(s)
Femoral Fractures/complications , Femoral Fractures/epidemiology , Rheumatic Diseases/complications , Adult , Aged , Aged, 80 and over , Female , Femoral Fractures/diagnostic imaging , Humans , Incidence , Japan/epidemiology , Male , Middle Aged , Rheumatic Diseases/diagnostic imaging , Rheumatic Diseases/epidemiology
5.
Article in English | MEDLINE | ID: mdl-22255343

ABSTRACT

We have developed a support system using our ultrasound diagnosis robot, which is able to support manual handling of ultrasound probe in echography to alleviate fatigue of examiner. This system realizes a coordinated motion according to the motion of the probe, which is hold by the robot and is moved by an examiner. We have established four kinds of situations, which are initial fixation, coordinate motions with/without contact on the body surface, and automatic chase motion of an internal organ. The system recognizes when the examiner grasps the ultrasound probe by 6-axis force sensor and touches it on body surface by processing echograms. Not only unskilled examiners but also a professional sonographer have evaluated the performance of the system after elucidating multiple parameters for compliance control and self-weight and moment compensation of the probe. As the results, this system has the potential to be able to support advanced diagnosis for conventional echography.


Subject(s)
Motion , Robotics , Ultrasonics , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...