Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 46
Filter
1.
J Clin Med ; 13(7)2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38610667

ABSTRACT

Background: Cardiac resynchronization therapy (CRT) has evolved into an established therapy for patients with chronic heart failure and a wide QRS complex. Data on long-term outcomes over time are scarce and the criteria for implantation remain a subject of investigation. Methods: An international, multicenter, retrospective registry includes 2275 patients who received CRT between 30 November 2000 and 31 December 2019, with a mean follow-up of 3.6 ± 2.7 years. Four time periods were defined, based on landmark trials and guidelines. The combined endpoint was a composite of all-cause mortality, heart transplantation, or left ventricular assist device implantation. Results: The composite endpoint occurred in 656 patients (29.2%). The mean annual implantation rate tripled from 31.5 ± 17.4/year in the first period to 107.4 ± 62.4/year in the last period. In the adjusted Cox regression analysis, the hazard ratio for the composite endpoint was not statistically different between time periods. When compared to sinus rhythm with left bundle branch block (LBBB), a non-LBBB conduction pattern (sinus rhythm: HR 1.51, 95% CI 1.12-2.03; atrial fibrillation: HR 2.08, 95% CI 1.30-3.33) and a QRS duration below 130 ms (HR 1.64, 95% CI 1.29-2.09) were associated with a higher hazard ratio. Conclusions: Despite innovations, an adjusted regression analysis revealed stable overall survival over time, which can at least partially be explained by a shift in patient characteristics.

2.
Eur Heart J Cardiovasc Imaging ; 25(5): 615, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38462576
4.
Eur Heart J Cardiovasc Imaging ; 25(3): 328-336, 2024 Feb 22.
Article in English | MEDLINE | ID: mdl-37933672

ABSTRACT

AIMS: Left bundle branch pacing (LBBP) has been shown to better maintain electrical synchrony compared with right ventricular pacing (RVP), but little is known about its impact on mechanical synchrony. This study investigates whether LBBP better preserves left ventricular (LV) mechanical synchronicity and function compared with RVP. METHODS AND RESULTS: Sixty patients with pacing indication for bradycardia were included: LBBP (n = 31) and RVP (n = 29). Echocardiography was performed before and shortly after pacemaker implantation and at 1-year follow-up. The lateral wall-septal wall (LW-SW) work difference was used as a measure of mechanical dyssynchrony. Septal flash, apical rocking, and septal strain patterns were also assessed. At baseline, LW-SW work difference was small and similar in two groups. SW was markedly decreased, while LW work remained mostly unchanged in RVP, resulting in a larger LW-SW work difference compared with LBBP (1253 ± 687 mmHg·% vs. 439 ± 408 mmHg·%, P < 0.01) at last follow-up. In addition, RVP more often induced septal flash or apical rocking and resulted in more advanced strain patterns compared with LBBP. At 1 year follow-up, LV ejection fraction (EF) and global longitudinal strain (GLS) were more decreased in RVP compared with LBBP (ΔLVEF: -7.4 ± 7.0% vs. 0.3 ± 4.1%; ΔLVGLS: -4.8 ± 4.0% vs. -1.4 ± 2.5%, both P < 0.01). In addition, ΔLW-SW work difference was independently correlated with LV adverse remodelling (r = 0.42, P < 0.01) and LV dysfunction (ΔLVEF: r = -0.61, P < 0.01 and ΔLVGLS: r = -0.38, P = 0.02). CONCLUSION: LBBP causes less LV mechanical dyssynchrony than RVP as it preserves a more physiologic electrical conduction. As a consequence, LBBP appears to preserve LV function better than RVP.


Subject(s)
Cardiac Pacing, Artificial , Ventricular Septum , Humans , Cardiac Pacing, Artificial/methods , Electrocardiography , Heart Ventricles/diagnostic imaging , Heart Conduction System , Ventricular Function, Left/physiology , Ventricular Remodeling , Treatment Outcome
5.
Eur J Heart Fail ; 26(2): 511-520, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37905357

ABSTRACT

AIM: Cardiac resynchronization therapy (CRT) is a cornerstone in the management of chronic heart failure in patients with a broad or paced QRS. However, data on long-term outcome after upgrade to CRT are scarce. METHODS AND RESULTS: This international, multicentre retrospective registry included 2275 patients who underwent a de novo or upgrade CRT implantation with a mean follow-up of 3.6 ± 2.7 years. The primary composite endpoint included all-cause mortality, heart transplantation, or ventricular assist device implantation. The secondary endpoint was first heart failure admission. Multivariable Cox regression and propensity score matching (PSM) analyses were performed. Patients who underwent CRT upgrade (n = 605, 26.6%) were less likely female (19.7% vs. 28.8%, p < 0.001), more often had ischeemic cardiomyopathy (49.8% vs. 40.2%, p < 0.001), and had worse renal function (median estimated glomerular filtration rate 50.3 ml/min/1.73 m2 [35.8-69.5] vs. 59.9 ml/min/1.73 m2 [43.0-76.5], p < 0.001). The incidence rate of the composite endpoint was 10.8%/year after CRT upgrade versus 7.1%/year for de novo implantations (p < 0.001). PSM for the primary endpoint resulted in 488 pairs. After propensity score matching, upgrade to CRT was associated with a higher chance to reach the composite endpoint (multivariable hazard ratio [HR] 1.35, 95% confidence interval [CI] 1.08-1.70), for both upgrade from pacemaker (multivariable HR 1.33, 95% CI 1.03-1.70) and implantable cardioverter-defibrillator (ICD) (multivariable HR 1.40, 95% CI 1.01-1.95). PSM for the secondary endpoint resulted in 277 pairs. After PSM, upgrade to CRT was associated with a higher chance for heart failure admission (HR 1.74, 95% CI 1.26-2.41). CONCLUSION: In this retrospective analysis, the outcome of patients who underwent upgrades to CRT differed significantly from patients who underwent de novo CRT implantation, particularly for upgrades from ICD. Importantly, this difference in outcome does not imply a causal relation between therapy and outcome but rather a difference between two different patient populations.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Female , Cardiac Resynchronization Therapy/methods , Propensity Score , Retrospective Studies , Treatment Outcome
6.
J Clin Med ; 12(18)2023 Sep 21.
Article in English | MEDLINE | ID: mdl-37763048

ABSTRACT

Background and aim: The presence of mechanical dyssynchrony on echocardiography is associated with reverse remodelling and decreased mortality after cardiac resynchronization therapy (CRT). Contrarily, myocardial scar reduces the effect of CRT. This study investigated how well a combined assessment of different markers of mechanical dyssynchrony and scarring identifies CRT responders. Methods: In a prospective multicentre study of 170 CRT recipients, septal flash (SF), apical rocking (ApRock), systolic stretch index (SSI), and lateral-to-septal (LW-S) work differences were assessed using echocardiography. Myocardial scarring was quantified using cardiac magnetic resonance imaging (CMR) or excluded based on a coronary angiogram and clinical history. The primary endpoint was a CRT response, defined as a ≥15% reduction in LV end-systolic volume 12 months after implantation. The secondary endpoint was time-to-death. Results: The combined assessment of mechanical dyssynchrony and septal scarring showed AUCs ranging between 0.81 (95%CI: 0.74-0.88) and 0.86 (95%CI: 0.79-0.91) for predicting a CRT response, without significant differences between the markers, but significantly higher than mechanical dyssynchrony alone. QRS morphology, QRS duration, and LV ejection fraction were not superior in their prediction. Predictive power was similar in the subgroups of patients with ischemic cardiomyopathy. The combined assessments significantly predicted all-cause mortality at 44 ± 13 months after CRT with a hazard ratio ranging from 0.28 (95%CI: 0.12-0.67) to 0.20 (95%CI: 0.08-0.49). Conclusions: The combined assessment of mechanical dyssynchrony and septal scarring identified CRT responders with high predictive power. Both visual and quantitative markers were highly feasible and demonstrated similar results. This work demonstrates the value of imaging LV mechanics and scarring in CRT candidates, which can already be achieved in a clinical routine.

8.
Clin Transplant ; 37(3): e14848, 2023 03.
Article in English | MEDLINE | ID: mdl-36374223

ABSTRACT

INTRODUCTION: Cytomegalovirus (CMV) is the most clinically relevant infectious agent following heart transplantation (HTX). Data on the beneficial effects of prophylactic use of CMV immunoglobulins (CMVIG) are scarce. METHODS: In this single-center, retrospective study, we reported patient outcomes following cardiac transplantation using prophylactic CMV treatment, including CMVIG. Distinct clinically relevant outcomes were compared across different CMV risk groups (CMV D-/R-, CMV D-/R+, CMV D+/R+, and CMV D+/R- or CMV high risk group). RESULTS: We included 272 heart transplant procedures, performed between 1/1/2009 and 1/11/2020. Sixty-one (22%) procedures belonged to the CMV high risk group, while 96 (35%), 50 (18%), and 65 (24%) were CMV D-/R-, CMV D-/R+, and CMV D+/R+, respectively. Baseline donor and recipient characteristics (sex, age, body mass index, cause of death, indication for HTX), ischemia times and baseline immunosuppressive regimens were similar across the different CMV risk groups, yet fewer patients were bridged with a mechanical circulatory support in the CMV D+/R- group. CMV disease following cardiac transplantation was more common in the CMV D+/R- risk group (n = 40 or 66.7%; p < .001), yet mortality and re-transplantation rates, cardiac allograft vasculopathy (CAV) severity, rejection episodes, and development of donor-specific antibodies (DSA), post-transplant lymphoproliferative diseases (PTLD), and EBV infections were similar across all four CMV risk groups. CONCLUSION: High risk CMV D+/R- patients had a similar survival compared to low and intermediate CMV risk groups using a prophylactic strategy combining CMVIG and viral DNA polymerase inhibitors. This may be related to a number of factors unrelated to prophylaxis strategy as two out of three CMV D+/R- recipients developed CMV primary infection after prophylaxis was discontinued.


Subject(s)
Cytomegalovirus Infections , Heart Transplantation , Humans , Cytomegalovirus , Antiviral Agents/therapeutic use , Retrospective Studies , Heart Transplantation/adverse effects , Transplant Recipients , Ganciclovir/pharmacology , Ganciclovir/therapeutic use
9.
Acta Cardiol ; 78(6): 687-698, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36222546

ABSTRACT

AIM: To provide a detailed description of the workflow at our telecardiology centre and to analyse the workload of real-world remote monitoring with the aim to assess the feasibility to outsource this service. METHODS: A retrospective analysis was conducted on the telecardiology service provided at the University Hospitals of Leuven by extracting patient demographic data, general time usage and detailed information about the type of remote contacts. 10,869 contacts in 948 patients have been included. A 2-week prospective study was conducted on the same service by documenting and monitoring every action performed by specialised nurses when analysing and solving remote monitoring transmissions. 337 contacts in 262 patients were collected during this period. RESULTS: Both analyses indicated similar numbers of events and interventions. Unplanned transmissions were more challenging and required more interventions than planned transmissions. Relatively little time (retrospective median: 1.83 min; prospective median: 1.56 min, per event) was spent on incoming non-actionable 'normal' transmissions (retrospective: 46%; prospective: 40% of all events). Retrospectively 54% and prospectively 60% of transmissions showed abnormalities and were responsible for most of the time expended. Disease-related issues were the most frequent cause for these 'abnormal' alerts. Contacting patients and physicians were key interventions undertaken. Interaction initiated by patients mainly involved the installation process (42%) and bedside monitoring problems (32%). CONCLUSION: External data centres could deal with 40% of the transmissions, but the decline in workload would be negligible for the in-hospital remote monitoring team, because very little time is spent dealing with the many 'non-event' transmissions whereas most of the time is spent solving clinical problems. Providing sufficient resources and optimising communication protocols is necessary to aid in managing the workload of the remote monitoring team.Implications for practiceContacting patients and physicians are key interventions for specialist nurses in remote monitoring centres.Detailed timing confirmed that most time was spent on relevant disease-related clinical problems.Despite dealing with ∼40% of transmissions, outsourcing to external data centres would decrease the workload only by 15-25%.Patient initiated contacts with questions concerning remote monitoring form a high burden and should be countered by scaling the service and creating communication protocols.


Subject(s)
Defibrillators, Implantable , Humans , Prospective Studies , Retrospective Studies , Tertiary Care Centers , Monitoring, Physiologic/methods
14.
Nucl Med Commun ; 43(5): 502-509, 2022 May 01.
Article in English | MEDLINE | ID: mdl-35045554

ABSTRACT

BACKGROUND: Accurate scar assessment is crucial in cardiac resynchronization therapy (CRT) candidates, since its presence is a negative predictor for CRT response. Therefore, we assessed the performance of different PET parameters to detect scar in CRT candidates. METHODS: Twenty-nine CRT candidates underwent 18F-fluorodeoxyglucose (18F-FDG)-PET/computed tomography (CT), resting 13N-NH3-PET/CT and cardiac magnetic resonance (CMR) prior to CRT implantation. Segmental 18F-FDG uptake, late 13N-NH3 uptake and absolute myocardial blood flow (MBF) were evaluated for scar detection using late gadolinium enhancement (LGE) CMR as reference. A receiver operator characteristic (ROC) area under the curve (AUC) ≥0.8 indicated a good accuracy of the methods evaluated. RESULTS: Scar was present in 111 of 464 segments. None of the approaches could reliably identify segments with nontransmural scar, except for 18F-FDG uptake in the lateral wall (AUC 0.83). Segmental transmural scars could be detected with all methods (AUC ≥ 0.8), except for septal 18F-FDG uptake and MBF in the inferior wall (AUC < 0.8). Late 13N-NH3 uptake was the best parameter for transmural scar detection, independent of its location, with a sensitivity of 80% and specificity of 92% using a cutoff of 66% of the maximum tracer activity. CONCLUSIONS: Late 13N-NH3 uptake is superior to 13N-NH3 MBF and 18F-FDG in detecting transmural scar, independently of its location. However, none of the tested PET parameters was able to accurately detect nontransmural scar.


Subject(s)
Cardiac Resynchronization Therapy , Fluorodeoxyglucose F18 , Cicatrix/diagnostic imaging , Contrast Media , Gadolinium , Humans , Nitrogen Radioisotopes , Positron Emission Tomography Computed Tomography
15.
Transpl Int ; 34(12): 2589-2596, 2021 12.
Article in English | MEDLINE | ID: mdl-34644421

ABSTRACT

Maximal exercise capacity of patients after heart transplantation (HTX) remains limited, affecting their quality of life. Evidence on the evolution of muscle strength and physical activity (PA) post-HTX is lacking, but a prerequisite to tailor cardiac rehabilitation programmes. Forty-five consecutive patients were evaluated every 3 months during the first year post-HTX. Functional exercise capacity (Six minutes walking distance test (6MWD)), peripheral (Quadriceps strength (QF)) and respiratory (Maximal inspiratory strength (MIP)) muscle strength were evaluated. PA (number of steps (PAsteps), active time (PAactive) and sedentary time (PAsed)) was objectively measured. 6MWD, QF, MIP, PAsteps and PAactive significantly improved over time (P < 0.001). No change in PAsed was noticed (P = 0.129). Despite improvements in 6MWD and QF, results remained substantially below those of age-and gender-matched healthy subjects. One year post-HTX, 30% of patients presented with peripheral muscle weakness. Baseline levels of 6MWD and QF were significantly higher in patients with pretransplant LVAD-implantation and this difference was maintained during follow-up. cardiac rehabilitation, combining aerobic exercise training and peripheral muscle strength training, is mandatory in patients post-HTX. Inspiratory muscle training should be implemented when respiratory muscle weakness is present. Programmes improving physical activity and reducing sedentary time post-HTX are essential.


Subject(s)
Exercise Tolerance , Heart Transplantation , Exercise , Exercise Test , Humans , Muscle Strength , Quality of Life
16.
ESC Heart Fail ; 8(4): 2940-2950, 2021 08.
Article in English | MEDLINE | ID: mdl-33960724

ABSTRACT

AIMS: Information on the prevalence, outcome and factors associated with heart failure in patients with adult congenital heart disease (CHD) (ACHD-HF) is lacking. We aimed at assessing the prevalence and outcome of ACHD-HF, the variables associated with ACHD-HF, and the differences between major anatomical/pathophysiological ACHD subgroups. METHODS AND RESULTS: We included 3905 patients (age 35.4 ± 13.2 years) under active follow-up in our institution (last visit >2010). Outcome of ACHD-HF cases was compared with sex- and age-matched cases. Univariable and multivariable binary logistic regression with ACHD-HF diagnosis as a dependent variable was performed. Overall prevalence of ACHD-HF was 6.4% (mean age 49.5 ± 16.7 years), but was higher in patients with cyanotic CHD (41%), Fontan circulation (30%), and a systemic right ventricle (25%). All-cause mortality was higher in ACHD-HF cases when compared with controls (mortality rate ratio 4.67 (2.36-9.27); P = 0.0001). In multivariable logistic regression analysis, age at latest follow-up [per 10 years; odds ratio (OR) 1.52; 95% confidence interval (CI) 1.31-1.77], infective endocarditis (OR 4.11; 95%CI 1.80-9.38), history of atrial arrhythmia (OR 3.52; 95%CI 2.17-5.74), pacemaker implantation (OR 2.66; 95% CI 1.50-4.72), end-organ dysfunction (OR 2.41; 95% CI 1.03-5.63), New York Heart Association class (OR 9.28; 95% CI 6.04-14.25), heart rate (per 10 bpm; OR 1.27; 95% CI 1.08-1.50), ventricular dysfunction (OR 3.62; 95% CI 2.54-5.17), and pulmonary hypertension severity (OR 1.66; 95% CI 1.21-2.30) were independently related to the presence of ACHD-HF. Some variables (age, atrial arrhythmia, pacemaker, New York Heart Association, and ventricular dysfunction) were related to ACHD-HF in all anatomical/physiological subgroups, whereas others were not. CONCLUSIONS: ACHD-HF is prevalent especially in complex CHD and is associated with poor prognosis. Our data provide insight in the factors related to ACHD-HF including differences between specific anatomical and physiological subgroups.


Subject(s)
Heart Defects, Congenital , Heart Failure , Hypertension, Pulmonary , Adult , Aged , Heart Defects, Congenital/complications , Heart Defects, Congenital/epidemiology , Heart Failure/epidemiology , Heart Failure/etiology , Humans , Middle Aged , Prevalence , Risk Factors , Young Adult
17.
Eur J Nucl Med Mol Imaging ; 48(8): 2437-2446, 2021 07.
Article in English | MEDLINE | ID: mdl-33416956

ABSTRACT

BACKGROUND: Cardiac resynchronization therapy (CRT) is effective in selective heart failure (HF) patients, but non-response rate remains high. Positron emission tomography (PET) may provide a better insight into the pathophysiology of left ventricular (LV) remodeling; however, its role for evaluating and selecting patients for CRT remains uncertain. PURPOSE: We investigated if regional LV glucose metabolism in combination with myocardial scar could predict response to CRT. METHODS: Consecutive CRT-eligible HF patients underwent echocardiography, cardiac magnetic resonance (CMR), and 18F-fluorodeoxyglucose (FDG) PET within 1 week before CRT implantation. Echocardiography was additionally performed 12 months after CRT and end-systolic volume reduction ≥ 15% was defined as CRT response. Septal-to-lateral wall (SLR) FDG uptake ratio was calculated from static FDG images. Late gadolinium enhancement (LGE) CMR was analyzed semi-quantitatively to define scar extent. RESULTS: We evaluated 88 patients (67 ± 10 years, 72% males). 18F-FDG SLR showed a linear correlation with volumetric reverse remodeling 12 months after CRT (r = 0.41, p = 0.0001). In non-ischemic HF patients, low FDG SLR alone predicted CRT response with sensitivity and specificity of more than 80%; however, in ischemic HF patients, specificity decreased to 46%, suggesting that in this cohort low SLR can also be caused by the presence of a septal scar. In the multivariate logistic regression model, including low FDG SLR, presence and extent of the scar in each myocardial wall, and current CRT guideline parameters, only low FDG SLR and septal scar remained associated with CRT response. Their combination could predict CRT response with sensitivity, specificity, negative, and positive predictive value of 80%, 83%, 70%, and 90%, respectively. CONCLUSIONS: FDG SLR can be used as a predictor of CRT response and combined with septal scar extent, CRT responders can be distinguished from non-responders with high diagnostic accuracy. Further studies are needed to verify whether this imaging approach can prospectively be used to optimize patient selection.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Cicatrix/diagnostic imaging , Contrast Media , Female , Gadolinium , Glucose , Heart Failure/diagnostic imaging , Heart Failure/therapy , Humans , Male , Tomography, X-Ray Computed , Treatment Outcome , Ventricular Remodeling
18.
Eur J Pharmacol ; 893: 173804, 2021 Feb 15.
Article in English | MEDLINE | ID: mdl-33347826

ABSTRACT

There is no known single therapeutic drug for treating hypercholesterolemia that comes with negligible systemic side effects. In the current study, using next generation RNA sequencing approach in mouse embryonic fibroblasts we discovered that two structurally related flavonoid compounds. Apigenin and Chrysin exhibited moderate blocking ability of multiple transcripts that regulate rate limiting enzymes in the cholesterol biosynthesis pathway. The observed decrease in cholesterol biosynthesis pathway correlated well with an increase in transcripts involved in generation and trafficking of ketone bodies as evident by the upregulation of Bdh1 and Slc16a6 transcripts. The hypocholesterolemic potential of Apigenin and Chrysin at higher concentrations along with their ability to generate ketogenic substrate especially during embryonic stage is useful or detrimental for embryonic health is not clear and still debatable. Our study will serve as a steppingstone to further the investigation in whole animal studies and also in translating this knowledge to human studies.


Subject(s)
Anticholesteremic Agents/pharmacology , Apigenin/pharmacology , Cholesterol/biosynthesis , Fibroblasts/drug effects , Flavonoids/pharmacology , Gene Expression Profiling , Ketone Bodies/metabolism , Lipogenesis/drug effects , Transcriptome , Animals , Anticholesteremic Agents/chemistry , Apigenin/chemistry , Cells, Cultured , Fibroblasts/metabolism , Flavonoids/chemistry , Gene Expression Regulation , Ketone Bodies/genetics , Lipogenesis/genetics , Mice , Molecular Structure
19.
Eur Heart J ; 41(39): 3813-3823, 2020 10 14.
Article in English | MEDLINE | ID: mdl-32918449

ABSTRACT

AIMS: Left ventricular (LV) failure in left bundle branch block is caused by loss of septal function and compensatory hyperfunction of the LV lateral wall (LW) which stimulates adverse remodelling. This study investigates if septal and LW function measured as myocardial work, alone and combined with assessment of septal viability, identifies responders to cardiac resynchronization therapy (CRT). METHODS AND RESULTS: In a prospective multicentre study of 200 CRT recipients, myocardial work was measured by pressure-strain analysis and viability by cardiac magnetic resonance (CMR) imaging (n = 125). CRT response was defined as ≥15% reduction in LV end-systolic volume after 6 months. Before CRT, septal work was markedly lower than LW work (P < 0.0001), and the difference was largest in CRT responders (P < 0.001). Work difference between septum and LW predicted CRT response with area under the curve (AUC) 0.77 (95% CI: 0.70-0.84) and was feasible in 98% of patients. In patients undergoing CMR, combining work difference and septal viability significantly increased AUC to 0.88 (95% CI: 0.81-0.95). This was superior to the predictive power of QRS morphology, QRS duration and the echocardiographic parameters septal flash, apical rocking, and systolic stretch index. Accuracy was similar for the subgroup of patients with QRS 120-150 ms as for the entire study group. Both work difference alone and work difference combined with septal viability predicted long-term survival without heart transplantation with hazard ratio 0.36 (95% CI: 0.18-0.74) and 0.21 (95% CI: 0.072-0.61), respectively. CONCLUSION: Assessment of myocardial work and septal viability identified CRT responders with high accuracy.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Echocardiography , Heart Failure/diagnostic imaging , Heart Failure/therapy , Humans , Magnetic Resonance Spectroscopy , Prospective Studies , Treatment Outcome , Ventricular Function, Left
20.
J Am Coll Cardiol ; 75(12): 1426-1438, 2020 03 31.
Article in English | MEDLINE | ID: mdl-32216911

ABSTRACT

BACKGROUND: The necessity of neurohumoral blockers in patients with heart failure who demonstrate normalized ejection fractions after cardiac resynchronization therapy remains unclear. OBJECTIVES: The aim of this study was to investigate the feasibility and safety of neurohumoral blocker withdrawal in patients with normalized ejection fractions after cardiac resynchronization therapy. METHODS: In this prospective, open-label, randomized controlled pilot trial with a 2 × 2 factorial design, subjects were randomized to withdrawal of renin-angiotensin-aldosterone system inhibitors and/or beta-blockers versus continuation of treatment. The primary endpoint was a recurrence of negative remodeling, defined as an increase in left ventricular end-systolic volume index of >15% at 24 months. The secondary endpoint was a composite safety endpoint of all-cause mortality, heart failure-related hospitalizations, and incidence of sustained ventricular arrhythmias at 24 months. RESULTS: Eighty subjects were consecutively enrolled and randomized among 4 groups (continuation of neurohumoral blocker therapy, n = 20; withdrawal of renin-angiotensin-aldosterone system inhibitors, n = 20; withdrawal of beta-blockers, n = 20; and withdrawal of renin-angiotensin-aldosterone system inhibitors and beta-blockers, n = 20). Of the 80 subjects, 6 (7.5%) met the primary and 4 (5%) the secondary endpoint. However, re-initiation of neurohumoral blockers occurred in 17 subjects because of hypertension or supraventricular arrhythmias. CONCLUSIONS: The incidence of the primary and secondary endpoints over a follow-up period of 2 years was low in both the control group and in the groups in which neurohumoral blockers were discontinued. However, neurohumoral blocker withdrawal was hampered by cardiac comorbidities. (Systematic Withdrawal of Neurohumoral Blocker Therapy in Optimally Responding CRT Patients [STOP-CRT]; NCT02200822).


Subject(s)
Adrenergic beta-Antagonists/administration & dosage , Angiotensin Receptor Antagonists/administration & dosage , Cardiac Resynchronization Therapy/trends , Heart Failure/therapy , Mineralocorticoid Receptor Antagonists/administration & dosage , Withholding Treatment/trends , Aged , Female , Follow-Up Studies , Heart Failure/diagnostic imaging , Humans , Male , Middle Aged , Pilot Projects , Prospective Studies , Renin-Angiotensin System/drug effects , Renin-Angiotensin System/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...