Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 14(1): 2604, 2024 01 31.
Article in English | MEDLINE | ID: mdl-38297022

ABSTRACT

The scale-free nature of daily human activity has been observed in different aspects; however, the description of its spectral characteristics is incomplete. General findings are complicated by the fact that-although actigraphy is commonly used in many research areas-the activity calculation methods are not standardized; therefore, activity signals can be different. The presence of 1/f noise in activity or acceleration signals was mostly analysed for short time windows, and the complete spectral characteristic has only been examined in the case of certain types of them. To explore the general spectral nature of human activity in greater detail, we have performed Power Spectral Density (PSD) based examination and Detrended Fluctuation Analysis (DFA) on several-day-long, triaxial actigraphic acceleration signals of 42 healthy, free-living individuals. We generated different types of activity signals from these, using different acceleration preprocessing techniques and activity metrics. We revealed that the spectra of different types of activity signals generally follow a universal characteristic including 1/f noise over frequencies above the circadian rhythmicity. Moreover, we discovered that the PSD of the raw acceleration signal has the same characteristic. Our findings prove that the spectral scale-free nature is generally inherent to the motor activity of healthy, free-living humans, and is not limited to any particular activity calculation method.


Subject(s)
Activities of Daily Living , Circadian Rhythm , Humans , Noise , Actigraphy , Acceleration
2.
Sensors (Basel) ; 23(2)2023 Jan 14.
Article in English | MEDLINE | ID: mdl-36679755

ABSTRACT

(1) Background and Goal: Several studies have investigated the association of sleep, diurnal patterns, and circadian rhythms with the presence and with the risk states of mental illnesses such as schizophrenia and bipolar disorder. The goal of our study was to examine actigraphic measures to identify features that can be extracted from them so that a machine learning model can detect premorbid latent liabilities for schizotypy and bipolarity. (2) Methods: Our team developed a small wrist-worn measurement device that collects and identifies actigraphic data based on an accelerometer. The sensors were used by carefully selected healthy participants who were divided into three groups: Control Group (C), Cyclothymia Factor Group (CFG), and Positive Schizotypy Factor Group (PSF). From the data they collected, our team performed data cleaning operations and then used the extracted metrics to generate the feature combinations deemed most effective, along with three machine learning algorithms for categorization. (3) Results: By conducting the training, we were able to identify a set of mildly correlated traits and their order of importance based on the Shapley value that had the greatest impact on the detection of bipolarity and schizotypy according to the logistic regression, Light Gradient Boost, and Random Forest algorithms. (4) Conclusions: These results were successfully compared to the results of other researchers; we had a similar differentiation in features used by others, and successfully developed new ones that might be a good complement for further research. In the future, identifying these traits may help us identify people at risk from mental disorders early in a cost-effective, automated way.


Subject(s)
Bipolar Disorder , Schizophrenia , Humans , Bipolar Disorder/diagnosis , Actigraphy/methods , Schizophrenia/diagnosis , Sleep , Circadian Rhythm
3.
PLoS One ; 16(12): e0261718, 2021.
Article in English | MEDLINE | ID: mdl-34932595

ABSTRACT

Actigraphic measurements are an important part of research in different disciplines, yet the procedure of determining activity values is unexpectedly not standardized in the literature. Although the measured raw acceleration signal can be diversely processed, and then the activity values can be calculated by different activity calculation methods, the documentations of them are generally incomplete or vary by manufacturer. These numerous activity metrics may require different types of preprocessing of the acceleration signal. For example, digital filtering of the acceleration signals can have various parameters; moreover, both the filter and the activity metrics can also be applied per axis or on the magnitudes of the acceleration vector. Level crossing-based activity metrics also depend on threshold level values, yet the determination of their exact values is unclear as well. Due to the serious inconsistency of determining activity values, we created a detailed and comprehensive comparison of the different available activity calculation procedures because, up to the present, it was lacking in the literature. We assessed the different methods by analysing the triaxial acceleration signals measured during a 10-day movement of 42 subjects. We calculated 148 different activity signals for each subject's movement using the combinations of various types of preprocessing and 7 different activity metrics applied on both axial and magnitude data. We determined the strength of the linear relationship between the metrics by correlation analysis, while we also examined the effects of the preprocessing steps. Moreover, we established that the standard deviation of the data series can be used as an appropriate, adaptive and generalized threshold level for the level intersection-based metrics. On the basis of these results, our work also serves as a general guide on how to proceed if one wants to determine activity from the raw acceleration data. All of the analysed raw acceleration signals are also publicly available.


Subject(s)
Actigraphy/statistics & numerical data , Exercise/statistics & numerical data , Actigraphy/instrumentation , Adolescent , Adult , Data Interpretation, Statistical , Female , Humans , Male , Models, Statistical , Young Adult
4.
Sci Rep ; 5: 13653, 2015 Sep 03.
Article in English | MEDLINE | ID: mdl-26333562

ABSTRACT

The Kirchhoff-Law-Johnson-Noise (KLJN) secure key exchange system has been introduced as a simple, very low cost and efficient classical physical alternative to quantum key distribution systems. The ideal system uses only a few electronic components-identical resistor pairs, switches and interconnecting wires-in order to guarantee perfectly protected data transmission. We show that a generalized KLJN system can provide unconditional security even if it is used with significantly less limitations. The more universal conditions ease practical realizations considerably and support more robust protection against attacks. Our theoretical results are confirmed by numerical simulations.

SELECTION OF CITATIONS
SEARCH DETAIL
...