Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
J Neurointerv Surg ; 14(5)2022 May.
Article in English | MEDLINE | ID: mdl-35115394

ABSTRACT

BACKGROUND: The micro-architectonics of the subarachnoid space (SAS) remain partially understood and largely ignored, likely the result of the inability to image these structures in vivo. We explored transvascular imaging with high-frequency optical coherence tomography (HF-OCT) to interrogate the SAS. METHODS: In vivo HF-OCT was performed in 10 dogs in both the posterior and anterior cerebral circulations. The conduit vessels used were the basilar, anterior spinal, and middle and anterior cerebral arteries through which the perivascular SAS was imaged. The HF-OCT imaging probe was introduced via a microcatheter and images were acquired using a contrast injection (3.5 mL/s) for blood clearance. Segmentation and three-dimensional rendering of HF-OCT images were performed to study the different configurations and porosity of the subarachnoid trabeculae (SAT) as a function of location. RESULTS: Of 13 acquisitions, three were excluded due to suboptimal image quality. Analysis of 15 locations from seven animals was performed showing six distinct configurations of arachnoid structures in the posterior circulation and middle cerebral artery, ranging from minimal presence of SAT to dense networks and membranes. Different locations showed predilection for specific arachnoid morphologies. At the basilar bifurcation, a thick, fenestrated membrane had a unique morphology. SAT average thickness was 100 µm and did not vary significantly based on location. Similarly, the porosity of the SAT averaged 91% and showed low variability. CONCLUSION: We have demonstrated the feasibility to image the structures of the SAS with transvascular HF-OCT. Future studies are planned to further map the SAT to increase our understanding of their function and possible impact on neurovascular pathologies.


Subject(s)
Subarachnoid Space , Tomography, Optical Coherence , Animals , Dogs , Humans , Intravital Microscopy , Microsurgery/methods , Subarachnoid Space/anatomy & histology , Subarachnoid Space/diagnostic imaging , Tomography, Optical Coherence/methods
2.
Front Neuroanat ; 13: 59, 2019.
Article in English | MEDLINE | ID: mdl-31275117

ABSTRACT

The prosomeric brain model contemplates progressive regionalization of the central nervous system (CNS) from a molecular and morphological ontogenetic perspective. It defines the forebrain axis relative to the notochord, and contemplates intersecting longitudinal (zonal, columnar) and transversal (neuromeric) patterning mechanisms. A checkboard pattern of histogenetic units of the neural wall results, where each unit is differentially fated by an unique profile of active genes. These natural neural units later expand their radial dimension during neurogenesis, histogenesis, and correlative differential morphogenesis. This fundamental topologic framework is shared by all vertebrates, as a Bauplan, each lineage varying in some subtle aspects. So far the prosomeric model has been applied only to neural structures, but we attempt here a prosomeric analysis of the hypothesis that major vessels invade the brain wall in patterns that are congruent with its intrinsic natural developmental units, as postulated in the prosomeric model. Anatomic and embryologic studies of brain blood vessels have classically recorded a conserved pattern of branches (thus the conventional terminology), and clinical experience has discovered a standard topography of many brain arterial terminal fields. Such results were described under assumptions of the columnar model of the forebrain, prevalent during the last century, but this is found insufficient in depth and explanatory power in the modern molecular scenario. We have thus explored the possibility that brain vascularization in rodents and humans may relate systematically to genoarchitectonic forebrain subdivisions contemplated in the prosomeric model. Specifically, we examined first whether early vascular invasion of some molecularly characterized prosomeric domains shows heterochrony. We indeed found a heterochronic pattern of vascular invasion that distinguishes between adjacent brain areas with differential molecular profiles. We next mapped topologically on the prosomeric model the major arterial branches serving the human brain. The results of this approach bear on the possibility of a developmentally-based modern arterial terminology.

3.
PLoS One ; 14(5): e0215294, 2019.
Article in English | MEDLINE | ID: mdl-31059517

ABSTRACT

Task-evoked Blood-oxygenation-level-dependent (BOLD-fMRI) signal activation is widely used to interrogate eloquence of brain areas. However, data interpretation can be improved, especially in regions with absent BOLD-fMRI signal activation. Absent BOLD-fMRI signal activation may actually represent false-negative activation due to impaired cerebrovascular reactivity (BOLD-CVR) of the vascular bed. The relationship between impaired BOLD-CVR and BOLD-fMRI signal activation may be better studied in healthy subjects where neurovascular coupling is known to be intact. Using a model-based prospective end-tidal carbon dioxide (CO2) targeting algorithm, we performed two controlled 3 tesla BOLD-CVR studies on 17 healthy subjects: 1: at the subjects' individual resting end-tidal CO2 baseline. 2: Around +6.0 mmHg CO2 above the subjects' individual resting baseline. Two BOLD-fMRI finger-tapping experiments were performed at similar normo- and hypercapnic levels. Relative BOLD fMRI signal activation and t-values were calculated for BOLD-CVR and BOLD-fMRI data. For each component of the cerebral motor-network (precentral gyrus, postcentral gyrus, supplementary motor area, cerebellum und fronto-operculum), the correlation between BOLD-CVR and BOLD-fMRI signal changes and t-values was investigated. Finally, a voxel-wise quantitative analysis of the impact of BOLD-CVR on BOLD-fMRI was performed. For the motor-network, the linear correlation coefficient between BOLD-CVR and BOLD-fMRI t-values were significant (p<0.01) and in the range 0.33-0.55, similar to the correlations between the CVR and fMRI Δ%signal (p<0.05; range 0.34-0.60). The linear relationship between CVR and fMRI is challenged by our voxel-wise analysis of Δ%signal and t-value change between normo- and hypercapnia. Our main finding is that BOLD fMRI signal activation maps are markedly dampened in the presence of impaired BOLD-CVR and highlights the importance of a complementary BOLD-CVR assessment in addition to a task-evoked BOLD fMRI to identify brain areas at risk for false-negative BOLD-fMRI signal activation.


Subject(s)
Brain/blood supply , Hypercapnia/diagnostic imaging , Magnetic Resonance Imaging/methods , Adult , Algorithms , Brain/diagnostic imaging , Cerebrovascular Circulation , Female , Humans , Image Processing, Computer-Assisted , Male , Neurovascular Coupling
4.
Neurosurg Focus ; 46(2): E7, 2019 02 01.
Article in English | MEDLINE | ID: mdl-30717072

ABSTRACT

Blood oxygenation level-dependent functional MRI cerebrovascular reactivity (BOLD-CVR) is a contemporary technique to assess brain tissue hemodynamic changes after extracranial- intracranial (EC-IC) bypass flow augmentation surgery. The authors conducted a preliminary study to investigate the feasibility and safety of intraoperative 3-T MRI BOLD-CVR after EC-IC bypass flow augmentation surgery. Five consecutive patients selected for EC-IC bypass revascularization underwent an intraoperative BOLD-CVR examination to assess early hemodynamic changes after revascularization and to confirm the safety of this technique. All patients had a normal postoperative course, and none of the patients exhibited complications or radiological alterations related to prolonged anesthesia time. In addition to intraoperative flow measurements of the bypass graft, BOLD-CVR maps added information on the hemodynamic status and changes at the brain tissue level. Intraoperative BOLD-CVR is feasible and safe in patients undergoing EC-IC bypass revascularization. This technique can offer immediate hemodynamic feedback on brain tissue revascularization after bypass flow augmentation surgery.


Subject(s)
Cerebral Revascularization/methods , Cerebrovascular Disorders/diagnostic imaging , Cerebrovascular Disorders/metabolism , Intraoperative Neurophysiological Monitoring/methods , Magnetic Resonance Imaging/methods , Oxygen Consumption/physiology , Aged , Cerebrovascular Circulation/physiology , Cerebrovascular Disorders/surgery , Feasibility Studies , Female , Humans , Male , Middle Aged , Treatment Outcome
5.
J Neurooncol ; 140(3): 659-667, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30196368

ABSTRACT

PURPOSE: Preoperative embolization of radiographically suspected meningiomas is often performed to facilitate tumor resection. Its effects on the subsequent disease course of meningioma patients have not been studied in detail and randomized trials are lacking. The purpose of this study was to explore associations of preoperative meningioma embolization with postoperative outcome. PATIENTS AND METHODS: Patients undergoing resection of an intracranial meningioma at the University Hospital Zurich 2000-2013 (N = 741) were reviewed for the inclusion of pre-operative embolization in the management strategy. Annotations included demographics, radiographic, surgical, histological and hematological parameters, cardiovascular risk factors, pre- and postoperative neurological function and gene methylation-based classification. Binary regression and Cox proportional hazards models were applied to determine factors associated with outcome. RESULTS: Pre-operative embolization was performed in 337 patients (42%). Cardiovascular events after surgery comprised mostly deep vein thrombosis (N = 39) and pulmonary embolisms (N = 64). On multivariate analyses of post-operative cardiovascular adverse events controlling for established risk factors, there were associations with embolization (OR 2.38, 95% CI 1.37-4.00), and with female gender (OR 2.18, 95% CI 1.17-4.08). Recurrence-free survival (RFS) of embolized patients was less favorable among patients with WHO grade II or grade III meningiomas (median RFS: 4.3 vs. 7.0 years, P = 0.029) or in patients with intermediate or malignant gene methylation subtype meningiomas (median RFS: 2.0 vs. 8.2 years, P = 0.005). CONCLUSION: Pre-operative meningioma embolization may cause adverse outcomes. Randomized trials to determine benefit-risk ratios are warranted to clarify the role of pre-operative embolization for the treatment of meningioma patients.


Subject(s)
Cardiovascular Diseases/etiology , Embolization, Therapeutic/adverse effects , Meningeal Neoplasms/therapy , Meningioma/therapy , Neoplasm Recurrence, Local/epidemiology , Preoperative Care/adverse effects , Adult , Aged , Aged, 80 and over , Cardiovascular Diseases/epidemiology , Disease-Free Survival , Female , Humans , Male , Meningeal Neoplasms/complications , Meningeal Neoplasms/epidemiology , Meningioma/complications , Meningioma/epidemiology , Middle Aged , Postoperative Complications , Retrospective Studies , Young Adult
6.
Neurology ; 91(14): e1328-e1337, 2018 10 02.
Article in English | MEDLINE | ID: mdl-30185447

ABSTRACT

OBJECTIVE: To study blood oxygen level-dependent cerebrovascular reactivity (BOLD-CVR) as a surrogate imaging marker for crossed cerebellar diaschisis (CCD). METHODS: Twenty-five participants with symptomatic unilateral cerebrovascular steno-occlusive disease underwent a BOLD-CVR and an acetazolamide challenged (15O)-H2O-PET study. CCD and cerebellar asymmetry index were determined from PET and compared to BOLD-CVR quantitative values. Neurologic status at admission and outcome after 3 months were determined with NIH Stroke Scale (NIHSS) and modified Rankin Scale (mRS) scores. RESULTS: For both the BOLD-CVR and PET examination, a significant cerebellar asymmetry index was found for participants exhibiting CCD (CCD+ vs CCD-: for BOLD-CVR 13.11 ± 9.46 vs 1.52 ± 4.97, p < 0.001; and for PET 7.31 ± 2.75 vs 1.68 ± 2.98, p < 0.001). The area under the curve for BOLD-CVR was 0.89 (95% confidence interval: 0.75-1.0) with 0.91 sensitivity and 0.81 specificity to detect CCD. Participants exhibiting CCD were in poorer clinical condition at baseline (CCD+ vs CCD-: NIHSS 7 vs 1, p = 0.003; mRS 3 vs 1, p = 0.001) and after 3-month follow-up (NIHSS 2 vs 0, p = 0.02; mRS 1 vs 0, p = 0.04). Worse performance on both scores showed an agreement with a larger BOLD-CVR cerebellar asymmetry index. This was not found for PET. CONCLUSIONS: BOLD-CVR demonstrates similar sensitivity to detect CCD as compared to (15O)-H2O-PET in patients with symptomatic unilateral cerebrovascular steno-occlusive disease. Furthermore, participants exhibiting CCD had a poorer baseline neurologic performance and neurologic outcome at 3 months. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that BOLD-CVR identifies CCD in patients with symptomatic unilateral cerebrovascular steno-occlusive disease.


Subject(s)
Brain/diagnostic imaging , Brain/physiopathology , Cerebellar Diseases/diagnostic imaging , Cerebellar Diseases/etiology , Cerebrovascular Disorders/complications , Magnetic Resonance Imaging , Adult , Aged , Aged, 80 and over , Cerebellar Diseases/physiopathology , Cerebrovascular Circulation , Cerebrovascular Disorders/diagnostic imaging , Cerebrovascular Disorders/physiopathology , Constriction, Pathologic/complications , Constriction, Pathologic/diagnostic imaging , Constriction, Pathologic/physiopathology , Female , Follow-Up Studies , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Oxygen/blood , Oxygen Radioisotopes , Positron-Emission Tomography , Prospective Studies , Radiopharmaceuticals , Sensitivity and Specificity
7.
Magn Reson Imaging ; 49: 123-130, 2018 06.
Article in English | MEDLINE | ID: mdl-29447850

ABSTRACT

Neurovascular coupling describes the cascade between neuronal activity and subsequent Blood-Oxygenation-Level-Dependent (BOLD) signal increase. Based on this premise, the correlation of this BOLD signal increase with a particular task, such as finger-tapping, is used to map neuronal activation. This signal increase may be dampened in brain areas exhibiting impaired cerebrovascular reactivity (BOLD-CVR), leading to false negative activation. Blood-oxygenation-level-dependent (BOLD) cerebrovascular reactivity (CVR) has also been used to optimize task evoked BOLD signal changes. To measure BOLD-CVR, controlled BOLD-CVR studies have commonly been performed using a preset isocapnic carbon dioxide (CO2; ~40 mmHg) baseline, independent of subjects' resting CO2. This arbitrary baseline, however, may influence BOLD-CVR measurements. We therefore performed BOLD-CVR, as well as BOLD fMRI during a controlled bilateral finger-tapping task in two groups of ten subjects: group A at subject's resting CO2 and group B at a preset isocapnic CO2 baseline (40 mmHg). Whole brain BOLD-CVR was significantly decreased for group B (group A 0.26 (SD 0.05) vs group B 0.16 (SD 0.05), p < 0.001). For the predefined hand area in the precentral cortex, BOLD-CVR and BOLD fMRI signal changes were significantly lower for group B (group A 0.20 (SD 0.04) vs group B 0.13 (SD 0.05), p < 0.01; 1.19 (SD 0.31) vs 0.62 (SD 0.37), p < 0.01).CO2 levels significantly influence both BOLD-CVR and BOLD fMRI measurements. Hence, for an accurate interpretation, baseline CO2 levels and BOLD CVR should be considered complementary to task evoked BOLD fMRI.


Subject(s)
Brain/physiology , Carbon Dioxide/blood , Cerebrovascular Circulation/physiology , Magnetic Resonance Imaging/methods , Signal Processing, Computer-Assisted , Adult , Brain/blood supply , Brain Mapping , Databases, Factual , Female , Fingers/physiology , Humans , Male , Prospective Studies , Reference Values
8.
Neuroradiology ; 60(4): 413-419, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29470603

ABSTRACT

PURPOSE: Intravoxel incoherent motion (IVIM) in diffusion-weighted magnetic resonance imaging (DW-MRI) attributes the signal attenuation to the molecular diffusion and to a faster pseudo-diffusion. Purpose of the study was to demonstrate the feasibility of IVIM for the investigation of intracranial cerebrospinal fluid (CSF) dynamics. METHODS: Cardiac-gated DW-MRI images with fifteen b-values (0-1300s/mm2) along three orthogonal directions (mediolateral (ML), anteroposterior (AP), and craniocaudal (CC)) were acquired during maximum systole and diastole in 10 healthy volunteers (6 males, mean age 36 ± 15 years). A pixel-wise bi-exponential fitting with an iterative nonparametric algorithm was carried out to calculate the following parameters: diffusion coefficient (D), fast diffusion coefficient (D*), and fraction of fast diffusion (f). Region of interest measurements were performed in both lateral ventricles. Comparison of IVIM parameters was performed among two cardiac cycle acquisitions and among the diffusion-encoding directions using a paired Student's t test. RESULTS: f significantly (p < 0.05) depended on the diffusion-encoding direction and on the cardiac cycle (diastole AP 0.30 ± 0.13, ML 0.22 ± 0.12, CC 0.26 ± 0.17; systole AP 0.45 ± 0.17, ML 0.34 ± 0.15, CC 0.40 ± 0.21). Neither a cardiac cycle nor a direction dependency was found among mean D values (which is in line with the expected intraventricular isotropic diffusion) and D* values (p > 0.05 each). CONCLUSION: The fraction of fast diffusion from IVIM is feasible to detect a direction-dependent and cardiac-dependent pulsatile CSF flow within the lateral ventricles allowing for quantitative monitoring of CSF dynamics. This technique might provide opportunities to further investigate the pathophysiology of various neurological disorders involving altered CSF dynamics.


Subject(s)
Cardiac-Gated Imaging Techniques/methods , Cerebrospinal Fluid Pressure/physiology , Diffusion Magnetic Resonance Imaging/methods , Lateral Ventricles/diagnostic imaging , Lateral Ventricles/physiology , Adult , Feasibility Studies , Female , Healthy Volunteers , Humans , Hydrodynamics , Male
9.
Stroke ; 49(3): 621-629, 2018 03.
Article in English | MEDLINE | ID: mdl-29371433

ABSTRACT

BACKGROUND AND PURPOSE: Increased stroke risk correlates with hemodynamic failure, which can be assessed with (15O-)H2O positron emission tomography (PET) cerebral blood flow (CBF) measurements. This gold standard technique, however, is not established for routine clinical imaging. Standardized blood oxygen-level-dependent (BOLD) functional magnetic resonance imaging+CO2 is a noninvasive and potentially widely applicable tool to assess whole-brain quantitative cerebrovascular reactivity (CVR). We examined the agreement between the 2 imaging modalities and hypothesized that quantitative CVR can be a surrogate imaging marker to assess hemodynamic failure. METHODS: Nineteen data sets of subjects with chronic cerebrovascular steno-occlusive disease (age, 60±11 years; 4 women) and unilaterally impaired perfusion reserve on Diamox-challenged (15O-)H2O PET were studied and compared with a standardized BOLD functional magnetic resonance imaging+CO2 examination within 6 weeks (8±19 days). Agreement between quantitative CBF- and CVR-based perfusion reserve was assessed. Hemodynamic failure was staged according to PET findings: stage 0: normal CBF, normal perfusion reserve; stage I: normal CBF, decreased perfusion reserve; and stage II: decreased CBF, decreased perfusion reserve. The BOLD CVR data set of the same subjects was then matched to the corresponding stage of hemodynamic failure. RESULTS: PET-based stage I versus stage II could also be clearly separated with BOLD CVR measurements (CVR for stage I 0.11 versus CVR for stage II -0.03; P<0.01). Hemispheric and middle cerebral artery territory difference analyses (ie, affected versus unaffected side) showed a significant correlation for CVR impairment in the affected hemisphere and middle cerebral artery territory (P<0.01, R2=0.47 and P=0.02, R2= 0.25, respectively). CONCLUSIONS: BOLD CVR corresponded well to CBF perfusion reserve measurements obtained with (15O-)H2O-PET, especially for detecting hemodynamic failure in the affected hemisphere and middle cerebral artery territory and for identifying hemodynamic failure stage II. BOLD CVR may, therefore, be considered for prospective studies assessing stroke risk in patients with chronic cerebrovascular steno-occlusive disease, in particular because it can potentially be implemented in routine clinical imaging.


Subject(s)
Brain Ischemia/diagnostic imaging , Hemodynamics , Magnetic Resonance Angiography/methods , Positron-Emission Tomography/methods , Stroke/diagnostic imaging , Aged , Brain Ischemia/blood , Carbon Dioxide/blood , Female , Humans , Male , Middle Aged , Oxygen/blood , Stroke/blood
10.
Neuroradiology ; 60(3): 281-291, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29356855

ABSTRACT

PURPOSE: To compare and to combine iterative metal artifact reduction (MAR) and virtual monoenergetic extrapolations (VMEs) from dual-energy computed tomography (DECT) for reducing metal artifacts from intracranial clips and coils. METHODS: Fourteen clips and six coils were scanned in a phantom model with DECT at 100 and 150SnkVp. Four datasets were reconstructed: non-corrected images (filtered-back projection), iterative MAR, VME from DECT at 120 keV, and combined iterative MAR + VME images. Artifact severity scores and visibility of simulated, contrast-filled, adjacent vessels were assessed qualitatively and quantitatively by two independent, blinded readers. RESULTS: Iterative MAR, VME, and combined iterative MAR + VME resulted in a significant reduction of qualitative (p < 0.001) and quantitative clip artifacts (p < 0.005) and improved the visibility of adjacent vessels (p < 0.05) compared to non-corrected images, with lowest artifact scores found in combined iterative MAR + VME images. Titanium clips demonstrated less artifacts than Phynox clips (p < 0.05), and artifact scores increased with clip size. Coil artifacts increased with coil size but were reducible when applying iterative MAR + VME compared to non-corrected images. However, no technique improved the severe artifacts from large, densely packed coils. CONCLUSIONS: Combining iterative MAR with VME allows for an improved metal artifact reduction from clips and smaller, loosely packed coils. Limited value was found for large and densely packed coils.


Subject(s)
Artifacts , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Prostheses and Implants , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Contrast Media , Humans , Metals , Phantoms, Imaging
11.
Magn Reson Imaging ; 45: 78-83, 2018 01.
Article in English | MEDLINE | ID: mdl-28986176

ABSTRACT

PURPOSE: Cerebral diffuse gliomas exhibit perilesional impaired cerebrovascular reactivity (CVR), yet the degree of impairment as well as its full spatial extent in the brain remains unknown. With quantitative fMRI, we studied twelve subjects with untreated brain diffuse glioma and twelve healthy controls to assess CVR impairment and determine its distribution throughout the brain. METHODS: In a prospective case-control study, quantitative CVR measurements were derived from BOLD fMRI volumes during standardized iso-oxic changes in carbon dioxide. Whole brain CVR was assessed with additional detailed analyses using specific tumor and tissue masks and compared to datasets of healthy controls. RESULTS: Whole brain CVR was significantly impaired compared to healthy controls (0.11±0.10 versus 0.28±0.8, p<0.01). All diffuse glioma patients exhibited even more severely impaired intralesional CVR (mean 0.01±0.06). Increasing tumor volume significantly correlated with severity of intralesional CVR impairment (p<0.05, R2=0.38), and whole brain CVR impairment (p<0.05, R2=0.55). CONCLUSION: Patients with brain diffuse glioma exhibit intralesional and whole brain impaired CVR with severity correlating to tumor volume. Quantitative fMRI may be entertained to study antitumor therapy efficacy by tracking CVR changes and may have a complementary role to better interpret BOLD associated neurovascular uncoupling.


Subject(s)
Brain Mapping/methods , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/physiopathology , Cerebrovascular Circulation/physiology , Glioma/diagnostic imaging , Glioma/physiopathology , Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Brain/diagnostic imaging , Brain/pathology , Brain/physiopathology , Brain Neoplasms/pathology , Case-Control Studies , Female , Glioma/pathology , Humans , Male , Middle Aged , Prospective Studies
12.
Brain Behav ; 7(9): e00705, 2017 09.
Article in English | MEDLINE | ID: mdl-28948064

ABSTRACT

OBJECTIVE: To improve quantitative cerebrovascular reactivity (CVR) measurements and CO 2 arrival times, we present an iterative analysis capable of decomposing different temporal components of the dynamic carbon dioxide- Blood Oxygen-Level Dependent (CO 2-BOLD) relationship. EXPERIMENTAL DESIGN: Decomposition of the dynamic parameters included a redefinition of the voxel-wise CO 2 arrival time, and a separation from the vascular response to a stepwise increase in CO 2 (Delay to signal Plateau - DTP) and a decrease in CO 2 (Delay to signal Baseline -DTB). Twenty-five (normal) datasets, obtained from BOLD MRI combined with a standardized pseudo-square wave CO 2 change, were co-registered to generate reference atlases for the aforementioned dynamic processes to score the voxel-by-voxel deviation probability from normal range. This analysis is further illustrated in two subjects with unilateral carotid artery occlusion using these reference atlases. PRINCIPAL OBSERVATIONS: We have found that our redefined CO 2 arrival time resulted in the best data fit. Additionally, excluding both dynamic BOLD phases (DTP and DTB) resulted in a static CVR, that is maximal response, defined as CVR calculated only over a normocapnic and hypercapnic calibrated plateau. CONCLUSION: Decomposition and novel iterative modeling of different temporal components of the dynamic CO 2-BOLD relationship improves quantitative CVR measurements.


Subject(s)
Brain/blood supply , Cerebrovascular Circulation/physiology , Hypercapnia/diagnostic imaging , Magnetic Resonance Imaging/methods , Oxygen/metabolism , Brain/diagnostic imaging , Humans
13.
J Comput Assist Tomogr ; 41(6): 843-848, 2017.
Article in English | MEDLINE | ID: mdl-28708725

ABSTRACT

OBJECTIVE: The technical feasibility of virtual noncontrast (VNC) images from dual-energy computed tomography (DECT) for the detection of the hyperdense artery sign (HAS) in ischemic stroke patients was investigated. METHODS: True noncontrast (TNC) scans of 60 patients either with or without HAS (n = 30 each) were investigated. Clot presence and characteristics were assessed on VNC images from DECT angiography and compared with TNC images. Clot characterization included the level of confidence for diagnosing HAS, a qualitative clot burden score, and quantitative attenuation (Hounsfield unit [HU]) measurements. RESULTS: Sensitivity, specificity, and accuracy of VNC for diagnosing HAS were 97%, 90%, and 93%, respectively. No significant differences were found regarding the diagnostic confidence (P = 0.18) and clot burden score (P = 0.071). No significant HU differences were found among vessels with HAS in VNC (56 ± 7HU) and TNC (57 ± 8HU) (P = 0.691) images. CONCLUSIONS: Virtual noncontrast images derived from DECT enable an accurate detection and characterization of HAS.


Subject(s)
Brain Ischemia/diagnostic imaging , Neuroimaging/methods , Radiography, Dual-Energy Scanned Projection , Stroke/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Angiography/methods , Brain Ischemia/complications , Female , Humans , Male , Middle Aged , Retrospective Studies , Stroke/etiology
14.
Invest Radiol ; 52(11): 680-685, 2017 11.
Article in English | MEDLINE | ID: mdl-28542096

ABSTRACT

OBJECTIVES: Computed tomography angiography (CTA) is a valuable tool for the assessment of carotid artery stenosis. However, blooming artifacts from calcified plaques might result in an overestimation of the stenosis grade. The aim of this study was to investigate a new dual-energy computed tomography (DECT) technique with a modified 3-material decomposition algorithm for calcium removal in extracranial carotid artery stenosis. MATERIALS AND METHODS: In this retrospective, institutional review board-approved study, 30 calcified carotid plaques in 22 patients (15 men; mean age, 73 ± 10 years) with clinical suspicion of stroke were included. Dual-energy computed tomography image data were obtained using second-generation dual-source CT with tube voltages at 80 and 140Sn kVp. Conventional CTA and virtual noncalcium (VNCa) images using the modified DECT algorithm were reconstructed. By assessing spectral characteristics, the modified DECT algorithm allows for a selective removal of calcium independent of blooming. Two independent and blinded readers evaluated subjective image quality, blooming artifacts, amount of (residual) calcification, and performed stenosis measurements according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) criteria. Differences were tested using a pairwise sign test. Paired sample t tests with Bonferroni correction (P < 0.017) and Bland-Altman analyses were used to test for differences in carotid stenosis measurements between VNCa and conventional CTA using digital subtraction angiography (DSA) as the standard of reference. RESULTS: Subjective image quality was similar among conventional CTA and VNCa image data sets (P = 0.82), whereas blooming artifacts were significantly reduced in VNCa images compared with conventional CTA (P < 0.001). Residual calcifications in VNCa images were absent in 11 (37%), minor in 12 (40%), medium sized in 2 (7%), and large in 5 (17%) arteries. Stenosis measurements differed significantly between VNCa (mean NASCET stenosis: 27% ± 20%) and conventional CTA images (mean NASCET stenosis: 39% ± 16%; P < 0.001) and between conventional CTA and DSA (23% ± 16%, P < 0.001). No significant differences in stenosis measurements were observed between VNCa and DSA (P = 0.189), with narrow limits of agreement (mean difference ±1.96 standard deviations: -4.7%, -35.1%, and 25.7%). CONCLUSIONS: A modified 3-material decomposition DECT algorithm for calcium removal was introduced, which allows for an accurate removal of calcified carotid plaques in extracranial carotid artery disease. The algorithm might overcome the problem of overestimation of calcified stenosis due to blooming artifacts in conventional CTA.


Subject(s)
Algorithms , Angiography, Digital Subtraction/methods , Calcinosis/diagnostic imaging , Carotid Stenosis/diagnostic imaging , Computed Tomography Angiography/methods , Aged , Aged, 80 and over , Artifacts , Carotid Arteries/diagnostic imaging , Cohort Studies , Female , Humans , Male , Middle Aged , Radiography, Dual-Energy Scanned Projection/methods , Reproducibility of Results , Retrospective Studies
17.
Magn Reson Med ; 77(2): 806-813, 2017 02.
Article in English | MEDLINE | ID: mdl-26918794

ABSTRACT

PURPOSE: To assess the feasibility of functional blood oxygen-level dependent (BOLD) MRI to evaluate intraoperative cerebrovascular reactivity (CVR) at 3 Tesla field strength. METHODS: Ten consecutive neurosurgical subjects scheduled for a clinical intraoperative MRI examination were enrolled in this study. In addition to the clinical protocol a BOLD sequence was implemented with three cycles of 44 s apnea to calculate CVR values on a voxel-by-voxel basis throughout the brain. The CVR range was then color-coded and superimposed on an anatomical volume to create high spatial resolution CVR maps. RESULTS: Ten subjects (mean age 34.8 ± 13.4; 2 females) uneventfully underwent the intraoperative BOLD protocol, with no complications occurring. Whole-brain CVR for all subjects was (mean ± SD) 0.69 ± 0.42, whereas CVR was markedly higher for tumor subjects as compared to vascular subjects, 0.81 ± 0.44 versus 0.33 ± 0.10, respectively. Furthermore, color-coded functional maps could be robustly interpreted for a whole-brain assessment of CVR. CONCLUSION: We demonstrate that intraoperative BOLD MRI is feasible in creating functional maps to assess cerebrovascular reactivity throughout the brain in subjects undergoing a neurosurgical procedure. Magn Reson Med 77:806-813, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Subject(s)
Brain , Cerebrovascular Circulation/physiology , Intraoperative Neurophysiological Monitoring/methods , Magnetic Resonance Imaging/methods , Adult , Brain/blood supply , Brain/diagnostic imaging , Female , Humans , Male , Middle Aged , Oxygen/blood , Oxygen/metabolism , Young Adult
18.
Swiss Med Wkly ; 146: w14361, 2016.
Article in English | MEDLINE | ID: mdl-27878793

ABSTRACT

Previous case studies reported nine patients with cerebral arteriovenous malformations (AVM) who developed amyotrophic lateral sclerosis (ALS) after AVM embolisation. Here, we describe three novel cases of ALS which developed 13-34 years after treatment, including embolisation, of cerebral AVM. This study provides further arguments supporting the thesis that embolisation of cerebral AVM might influence the risk of later ALS development.


Subject(s)
Amyotrophic Lateral Sclerosis/etiology , Embolization, Therapeutic/adverse effects , Intracranial Arteriovenous Malformations/complications , Adult , Amyotrophic Lateral Sclerosis/pathology , Female , Humans , Middle Aged , Risk Factors , Time Factors
19.
World Neurosurg ; 92: 292-297, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27150647

ABSTRACT

OBJECTIVE: To establish an arteriovenous malformation (AVM) grading score for patients with ruptured AVM and associated intracerebral hemorrhage (ICH) to predict clinical outcome. METHODS: Patient data from January 2006 to December 2013 with newly diagnosed ICH caused by ruptured AVM and a modified Rankin Scale (mRS) score <2 before ICH were included for this analysis. Clinical outcome was dichotomized in favorable (mRS score, 0-2) and unfavorable (mRS score, 3-6) to find predictors for outcome and to establish a new score based on the areas under the receiver-operating characteristic curves (AUROC) at 3 months, 1 year, and at last follow-up (mean, 31 months). RESULTS: A total of 67 patients (mean age, 41 years; 66% male) were analyzed including 39 patients with favorable and 28 with unfavorable outcome. Intraventricular hemorrhage (P = 0.048), ICH score (P = 0.003), AVM size (P < 0.001), Spetzler-Martin grade (P < 0.001), nidus structure (P = 0.005), Lawton-Young grade (P = 0.015), and supplemented Spetzler-Martin score (P < 0.001) were significant predictors for clinical outcome in ruptured AVMs. Based on these results, we created a new score named the AVICH (AVM-related ICH) score, which showed an AUROC of 0.842 compared to 0.789 for the supplemented Spetzler-Martin grading system and 0.703 for the ICH score regarding clinical outcome at last follow-up. CONCLUSIONS: Based on the AUROC analysis, the AVICH score predicts outcome of patients with ruptured AVM and associated ICH better than the ICH score, the Spetzler-Martin, or the supplemented Spetzler-Martin grading system. An external validation is needed before the AVICH score is tested in a prospective multicenter cohort.


Subject(s)
Cerebral Hemorrhage , Embolization, Therapeutic/methods , Intracranial Arteriovenous Malformations/complications , Outcome Assessment, Health Care/methods , Severity of Illness Index , Adult , Cerebral Hemorrhage/diagnosis , Cerebral Hemorrhage/etiology , Cerebral Hemorrhage/surgery , Female , Humans , Longitudinal Studies , Male , Middle Aged , Predictive Value of Tests , ROC Curve , Retrospective Studies , Treatment Outcome , Young Adult
20.
Brain Behav ; 6(2): e00426, 2016 02.
Article in English | MEDLINE | ID: mdl-27110448

ABSTRACT

INTRODUCTION: We elaborate on existing analysis methods for breath-hold (BH)-derived cerebrovascular reactivity (CVR) measurements and describe novel insights and models toward more exact CVR interpretation. METHODS: Five blood-oxygen-level-dependent (BOLD) fMRI datasets of neurovascular patients with unilateral hemispheric hemodynamic impairment were used to test various BH CVR analysis methods. Temporal lag (phase), percent BOLD signal change (CVR), and explained variance (coherence) maps were calculated using three different sine models and two novel "Optimal Signal" model-free methods based on the unaffected hemisphere and the sagittal sinus fMRI signal time series, respectively. RESULTS: All models showed significant differences in CVR and coherence between the affected-hemodynamic impaired-and unaffected hemisphere. Voxel-wise phase determination significantly increases CVR (0.60 ± 0.18 vs. 0.82 ± 0.27; P < 0.05). Incorporating different durations of breath hold and resting period in one sine model (two-task) did increase coherence in the unaffected hemisphere, as well as eliminating negative phase commonly obtained by one-task frequency models. The novel model-free "optimal signal" methods both explained the BOLD MR data similar to the two task sine model. CONCLUSIONS: Our CVR analysis demonstrates an improved CVR and coherence after implementation of voxel-wise phase and frequency adjustment. The novel "optimal signal" methods provide a robust and feasible alternative to the sine models, as both are model-free and independent of compliance. Here, the sagittal sinus model may be advantageous, as it is independent of hemispheric CVR impairment.


Subject(s)
Brain/blood supply , Breath Holding , Cerebrovascular Circulation/physiology , Magnetic Resonance Imaging , Models, Cardiovascular , Models, Neurological , Aged , Brain/diagnostic imaging , Brain/physiology , Brain Mapping/methods , Datasets as Topic , Humans , Magnetic Resonance Imaging/methods , Male , Oxygen/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL