Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 19(6): e0304268, 2024.
Article in English | MEDLINE | ID: mdl-38838004

ABSTRACT

American tegumentary leishmaniasis (ATL) diagnosis is an open question, and the search for a solution is urgent. The available tests that detect the etiological agent of the infection are specific for ATL diagnosis. However, they present disadvantages, such as low sensitivity and the need for invasive procedures to obtain the samples. Immunological methods (leishmanin skin test and search for anti-Leishmania antibodies) are good alternatives to the etiological diagnosis of ATL. Presently, we face problems with disease confirmation due to the discontinuity in the production of leishmanin skin test antigen, particularly in resource-poor settings. Aiming to diagnose ATL, we validated rLb6H-ELISA for IgG antibodies using 1,091 samples from leishmaniasis patients and healthy controls, divided into four panels, living in 19 Brazilian endemic and non-endemic states. The rLb6H-ELISA showed a sensitivity of 98.6% and a specificity of 100.0%, with the reference panel comprising 70 ATL patient samples and 70 healthy controls. The reproducibility evaluation showed a coefficient of variation of positive samples ≤ 8.20% for repeatability, ≤ 17,97% for reproducibility, and ≤ 8.12% for homogeneity. The plates sensitized with rLb6H were stable at 4°C and -20°C for 180 days and 37°C for seven days, indicating 12 months of validity. In samples of ATL patients from five research and healthcare centers in endemic and non-endemic areas, rLb6H-ELISA showed a sensitivity of 84.0%; no significant statistical difference was observed among the five centers (chi-square test, p = 0.13). In samples of healthy controls from four areas with different endemicity, a specificity of 92.4% was obtained; lower specificity was obtained in a visceral leishmaniasis high endemicity locality (chi-square test, p<0.001). Cross-reactivity was assessed in 166 other disease samples with a positivity of 13.9%. Based on the good diagnostic performance and the reproducibility and stability of the antigen, we suggest using ELISA-rLb6H to diagnose ATL.


Subject(s)
Antigens, Protozoan , Enzyme-Linked Immunosorbent Assay , Leishmaniasis, Cutaneous , Humans , Leishmaniasis, Cutaneous/diagnosis , Leishmaniasis, Cutaneous/immunology , Leishmaniasis, Cutaneous/parasitology , Leishmaniasis, Cutaneous/epidemiology , Enzyme-Linked Immunosorbent Assay/methods , Antigens, Protozoan/immunology , Female , Male , Adult , Middle Aged , Sensitivity and Specificity , Adolescent , Reproducibility of Results , Recombinant Proteins/immunology , Young Adult , Immunoglobulin G/blood , Immunoglobulin G/immunology , Antibodies, Protozoan/blood , Antibodies, Protozoan/immunology , Aged , Child , Case-Control Studies , Brazil/epidemiology
2.
PLoS One ; 18(3): e0282483, 2023.
Article in English | MEDLINE | ID: mdl-36862710

ABSTRACT

In the Americas, visceral leishmaniasis (VL) is caused by the protozoan Leishmania infantum, leading to death if not promptly diagnosed and treated. In Brazil, the disease reaches all regions, and in 2020, 1,933 VL cases were reported with 9.5% lethality. Thus, an accurate diagnosis is essential to provide the appropriate treatment. Serological VL diagnosis is based mainly on immunochromatographic tests, but their performance may vary by location, and evaluation of diagnostic alternatives is necessary. In this study, we aimed to evaluate the performance of ELISA with the scantily studied recombinant antigens, K18 and KR95, comparing their performance with the already known rK28 and rK39. Sera from parasitologically confirmed symptomatic VL patients (n = 90) and healthy endemic controls (n = 90) were submitted to ELISA with rK18 and rKR95. Sensitivity (95% CI) was, respectively, 83.3% (74.2-89.7) and 95.6% (88.8-98.6), and specificity (95% CI) was 93.3% (85.9-97.2) and 97.8% (91.8-99.9). For validation of ELISA with the recombinant antigens, we included samples from 122 VL patients and 83 healthy controls collected in three regions in Brazil (Northeast, Southeast, and Midwest). When comparing the results obtained with the VL patients' samples, significantly lower sensitivity was obtained by rK18-ELISA (88.5%, 95% CI: 81.5-93.2) compared with rK28-ELISA (95.9%, 95% CI: 90.5-98.5), but the sensitivity was similar comparing rKR95-ELISA (95.1%, 95% CI: 89.5-98.0), rK28-ELISA (95.9%, 95% CI: 90.5-98.5), and rK39-ELISA (94.3%, 95% CI: 88.4-97.4). Analyzing the specificity, it was lowest with rK18-ELISA (62.7%, 95% CI: 51.9-72.3) with 83 healthy control samples. Conversely, higher and similar specificity was obtained by rKR95-ELISA (96.4%, 95% CI: 89.5-99.2), rK28-ELISA (95.2%, 95% CI: 87.9-98.5), and rK39-ELISA (95.2%, 95% CI: 87.9-98.5). There was no difference in sensitivity and specificity across localities. Cross-reactivity assessment, performed with sera of patients diagnosed with inflammatory disorders and other infectious diseases, was 34.2% with rK18-ELISA and 3.1% with rKR95-ELISA. Based on these data, we suggest using recombinant antigen KR95 in serological assays for VL diagnosis.


Subject(s)
Leishmaniasis, Visceral , Humans , Biological Assay , Brazil , Cross Reactions , Enzyme-Linked Immunosorbent Assay , Leishmaniasis, Visceral/diagnosis , Recombinant Proteins
SELECTION OF CITATIONS
SEARCH DETAIL
...