Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Endovasc Ther ; 30(3): 364-371, 2023 06.
Article in English | MEDLINE | ID: mdl-35236169

ABSTRACT

PURPOSE: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) is gaining popularity for the quantification of tissue perfusion, including foot perfusion in patients with lower extremity arterial disease (LEAD). However, the absolute fluorescence intensity is influenced by patient-and system-related factors limiting reliable and valid quantification. To enhance the quality of quantitative perfusion assessment using ICG NIR fluorescence imaging, normalization of the measured time-intensity curves seems useful. MATERIALS AND METHODS: In this cohort study, the effect of normalization on 2 aspects of ICG NIR fluorescence imaging in assessment of foot perfusion was measured: the repeatability and the region selection. Following intravenous administration of ICG, the NIR fluorescence intensity in both feet was recorded for 10 mins using the Quest Spectrum platform®. The effect of normalization on repeatability was measured in the nontreated foot in patients undergoing unilateral revascularization preprocedural and postprocedural (repeatability group). The effect of normalization on region selection was performed in patients without LEAD (region selection group). Absolute and normalized time-intensity curves were compared. RESULTS: Successful ICG NIR fluorescence imaging was performed in 54 patients (repeatability group, n = 38; region selection group, n = 16). For the repeatability group, normalization of the time-intensity curves displayed a comparable inflow pattern for repeated measurements. For the region selection group, the maximum fluorescence intensity (Imax) demonstrated significant differences between the 3 measured regions of the foot (P = .002). Following normalization, the time-intensity curves in both feet were comparable for all 3 regions. CONCLUSION: This study shows the effect of normalization of time-intensity curves on both the repeatability and region selection in ICG NIR fluorescence imaging. The significant difference between absolute parameters in various regions of the foot demonstrates the limitation of absolute intensity in interpreting tissue perfusion. Therefore, normalization and standardization of camera settings are essential steps toward reliable and valid quantification of tissue perfusion using ICG NIR fluorescence imaging.


Subject(s)
Indocyanine Green , Lower Extremity , Humans , Cohort Studies , Treatment Outcome , Optical Imaging/methods , Perfusion
2.
Ann Vasc Surg ; 78: 281-287, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34182113

ABSTRACT

BACKGROUND: Patients with chronic limb threatening ischemia have a risk of undergoing a major amputation within 1 year of nearly 30% with a substantial risk of re-amputation since wound healing is often impaired. Quantitative assessment of regional tissue viability following amputation surgery can identify patients at risk for impaired wound healing. In quantification of regional tissue perfusion, near-infrared (NIR) fluorescence imaging using Indocyanine Green (ICG) seems promising. METHODS: This pilot study included adult patients undergoing lower extremity amputation surgery due to peripheral artery disease or diabetes mellitus. ICG NIR fluorescence imaging was performed within 5 days following amputation surgery using the Quest Spectrum PlatformⓇ. Following intravenous administration of ICG, the NIR fluorescence intensity of the amputation wound was recorded for 10 minutes. The NIR fluorescence intensity videos were analyzed and if a fluorescence deficit was observed, this region was marked as "low fluorescence." All other regions were marked as "normal fluorescence." RESULTS: Successful ICG NIR fluorescence imaging was performed in 10 patients undergoing a total of 15 amputations. No "low fluorescence" regions were observed in 11 out of 15 amputation wounds. In 10 out of these 11 amputations, no wound healing problems occurred during follow-up. Regions with "low fluorescence" were observed in 4 amputation wounds. Impaired wound healing corresponding to these regions was observed in all wounds and a re-amputation was necessary in 3 out of 4. When observing time-related parameters, regions with low fluorescence had a significantly longer time to maximum intensity (113 seconds vs. 32 seconds, P = 0.003) and a significantly lesser decline in outflow after five minutes (80.3% vs. 57.0%, P = 0.003). CONCLUSIONS: ICG NIR fluorescence imaging was able to predict postoperative skin necrosis in all four cases. Quantitative assessment of regional perfusion remains challenging due toinfluencing factors on the NIR fluorescence intensity signal, including camera angle, camera distance and ICG dosage. This was also observed in this study, contributing to a large variety in fluorescence intensity parameters among patients. To provide surgeons with reliable NIR fluorescence cut-off values for prediction of wound healing, prospective studies on the intra-operative use of this technique are required. The potential prediction of wound healing using ICG NIR fluorescence imaging will have a huge impact on patient mortality, morbidity as well as the burden of amputation surgery on health care.


Subject(s)
Amputation, Surgical , Diabetic Angiopathies/surgery , Fluorescent Dyes/administration & dosage , Indocyanine Green/administration & dosage , Ischemia/surgery , Perfusion Imaging , Peripheral Arterial Disease/surgery , Skin/blood supply , Spectroscopy, Near-Infrared , Aged , Chronic Disease , Diabetic Angiopathies/diagnostic imaging , Diabetic Angiopathies/physiopathology , Female , Humans , Ischemia/diagnostic imaging , Ischemia/physiopathology , Male , Middle Aged , Necrosis , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Pilot Projects , Predictive Value of Tests , Prospective Studies , Regional Blood Flow , Skin/pathology , Tissue Survival , Treatment Outcome , Wound Healing
SELECTION OF CITATIONS
SEARCH DETAIL