1.
Environ Mol Mutagen ; 61(5): 508-525, 2020 06.
Article in English | MEDLINE | ID: mdl-32187737

ABSTRACT

Acetaminophen, a nonmutagenic compound as previously concluded from bacteria, in vitro mammalian cell, and in vivo transgenic rat assays, presented a good profile as a nonmutagenic reference compound for use in the international multilaboratory Pig-a assay validation. Acetaminophen was administered at 250, 500, 1,000, and 2,000 mg·kg-1 ·day-1 to male Sprague Dawley rats once daily in 3 studies (3 days, 2 weeks, and 1 month with a 1-month recovery group). The 3-Day and 1-Month Studies included assessments of the micronucleus endpoint in peripheral blood erythrocytes and the comet endpoint in liver cells and peripheral blood cells in addition to the Pig-a assay; appropriate positive controls were included for each assay. Within these studies, potential toxicity of acetaminophen was evaluated and confirmed by inclusion of liver damage biomarkers and histopathology. Blood was sampled pre-treatment and at multiple time points up to Day 57. Pig-a mutant frequencies were determined in total red blood cells (RBCs) and reticulocytes (RETs) as CD59-negative RBC and CD59-negative RET frequencies, respectively. No increases in DNA damage as indicated through Pig-a, micronucleus, or comet endpoints were seen in treated rats. All positive controls responded as appropriate. Data from this series of studies demonstrate that acetaminophen is not mutagenic in the rat Pig-a model. These data are consistent with multiple studies in other nonclinical models, which have shown that acetaminophen is not mutagenic. At 1,000 mg·kg-1 ·day-1 , Cmax values of acetaminophen on Day 28 were 153,600 ng/ml and 131,500 ng/ml after single and repeat dosing, respectively, which were multiples over that of clinical therapeutic exposures (2.6-6.1 fold for single doses of 4,000 mg and 1,000 mg, respectively, and 11.5 fold for multiple dose of 4,000 mg) (FDA 2002). Data generated were of high quality and valid for contribution to the international multilaboratory validation of the in vivo Rat Pig-a Mutation Assay.


Subject(s)
Acetaminophen/pharmacology , Biological Assay , Internationality , Laboratories , Mutagenicity Tests , Animals , Comet Assay , Male , Micronucleus Tests , Mutagens/toxicity , Rats, Sprague-Dawley , Reproducibility of Results
2.
Environ Mol Mutagen ; 52(9): 690-8, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21910140

ABSTRACT

A collaborative international trial was conducted to evaluate the reproducibility and transferability of an in vivo mutation assay based on the enumeration of CD59-negative rat erythrocytes, a phenotype that is indicative of Pig-a gene mutation. Fourteen laboratories participated in this study, where anti-CD59-PE, SYTO 13 dye, and flow cytometry were used to determine the frequency of CD59-negative erythrocytes (RBC(CD59-)) and CD59-negative reticulocytes (RET(CD59-)). To provide samples with a range of mutant phenotype cell frequencies, male rats were exposed to N-ethyl-N-nitrosourea (ENU) via oral gavage for three consecutive days (Days 1-3). Each laboratory studied 0, 20, and 40 mg ENU/kg/day (n = 5 per group). Three sites also evaluated 4 mg/kg/day. At a minimum, blood samples were collected three times: predosing and on Days 15 and 30. Blood samples were processed according to a standardized sample processing and data acquisition protocol, and three endpoints were measured: %reticulocytes, frequency of RET(CD59-) , and frequency of RBC(CD59-) . The methodology was found to be reproducible, as the analysis of technical replicates resulted in experimental coefficients of variation that approached theoretical values. Good transferability was evident from the similar kinetics and magnitude of the dose-related responses that were observed among different laboratories. Concordance correlation coefficients showed a high level of agreement between the reference site and the test sites (range: 0.87-0.99). Collectively, these data demonstrate that with adequate training of personnel, flow cytometric analysis is capable of reliably enumerating mutant phenotype erythrocytes, thereby providing a robust in vivo mutation assay that is readily transferable across laboratories.


Subject(s)
Flow Cytometry , Laboratories , Membrane Proteins/genetics , Mutagenicity Tests , Mutation , Animals , CD59 Antigens/genetics , Calibration , Data Interpretation, Statistical , Endpoint Determination , Erythrocytes/drug effects , Erythrocytes/metabolism , Erythrocytes/ultrastructure , Ethylnitrosourea/toxicity , Flow Cytometry/methods , Flow Cytometry/standards , International Cooperation , Laboratories/standards , Mutagenicity Tests/methods , Mutagenicity Tests/standards , Mutagens/toxicity , Rats , Rats, Inbred F344 , Rats, Sprague-Dawley , Rats, Wistar , Reference Standards , Reproducibility of Results , Reticulocytes/drug effects , Reticulocytes/metabolism , Reticulocytes/ultrastructure , Risk Assessment , Time Factors