Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 17(8): e0272722, 2022.
Article in English | MEDLINE | ID: mdl-36006969

ABSTRACT

BACKGROUND: Accurate restoration of joint line height and posterior offset in primary Total Knee Arthroplasty (TKA) have been shown to be important factors in post-operative range of movement and function. The aim of this study was to assess the accuracy of joint line and posterior offset restoration in a group of patients that underwent robotic-assisted TKA (raTKA). A matched cohort of patients that underwent a TKA using a conventional jig-based technique was assessed for comparison. The null hypothesis was that there would be no difference between groups. METHODS: This study was a retrospective analysis of a cohort of 120 patients with end-stage knee osteoarthritis that received a TKA using the Navio Surgical System (n = 60), or Conventional manual TKA (n = 60). Procedures were performed between 1 January 2019 and 1 October 2019 at six different centres. Joint line height and posterior offset was measured pre-operatively and post-operatively on calibrated weight bearing plain radiographs of the knee. Two observers performed measurements using validated measuring tools. A BMI and age-matched cohort of patients that underwent TKA using a conventional technique in the same six centres were assessed for comparison. Mean values, standard deviations and confidence intervals are presented for change and absolute change in joint line height and posterior offset. Student's t-test was used to compare the changes between techniques. RESULTS: Patients that underwent robotic-assisted TKA had joint line height and posterior offset restored more accurately than patients undergoing TKA using a conventional technique. Average change from pre-operative measurement in joint line height using raTKA was -0.38mm [95% CI: -0.79 to 0.03] vs 0.91 [0.14 to 1.68] with the conventional technique. Average absolute change in joint line height using raTKA was 1.96mm [1.74 to 2.18] vs 4.00mm [3.68 to 4.32] with the conventional technique. Average change in posterior offset using raTKA was 0.08mm [-0.40 to 0.56] vs 1.64mm [2.47 to 0.81] with the conventional technique. Average absolute change in posterior offset with raTKA was 2.19mm [1.92 to 2.46] vs 4.24mm [3.79 to 4.69] with the conventional technique. There was a significant difference when comparing absolute change in joint line height and posterior offset between groups (p<0.01). CONCLUSION: Robotic-assisted primary TKA restores the joint line height and posterior offset more accurately than conventional jig-based techniques.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Robotic Surgical Procedures , Arthroplasty, Replacement, Knee/methods , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Retrospective Studies , Robotic Surgical Procedures/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...