Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 60
Filter
1.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Article in English | MEDLINE | ID: mdl-38506737

ABSTRACT

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Subject(s)
Aortic Valve Insufficiency , Bioprosthesis , Coronary Occlusion , Transcatheter Aortic Valve Replacement , Humans , Catheters , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Heart Valves , Registries , Transcatheter Aortic Valve Replacement/adverse effects
2.
EuroIntervention ; 20(2): e158-e167, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38224253

ABSTRACT

BACKGROUND: Both surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) are Class Ia recommended therapies for specific subgroups of severe aortic stenosis (AS) patients in the latest 2021 European guidelines. AIMS: We aimed to report on the multidisciplinary Heart Team evaluation process and real-world practice of treating severe symptomatic AS in East Denmark in the context of the latest European guideline recommendations. METHODS: All consecutive patients with severe AS referred for intervention in 2021 (N=672) were discussed in a multidisciplinary Heart Team meeting. All patients (100%) had a cardiac computed tomography (CT) analysis prior to the meeting. Baseline characteristics, Heart Team decision-making, final treatment and 30-day clinical outcomes were prospectively recorded. RESULTS: The majority of severe AS patients (N=456, 68%) were referred for TAVI following discussion in the Heart Team. Ultimately, 94% of patients (N=632) received the Heart Team-recommended treatment. Patients undergoing TAVI (N=439) were significantly older (78.4±6.7 vs 67.2±8.3 years; p<0.001) and more comorbid than patients undergoing SAVR (N=189). The overall 30-day clinical outcomes were satisfactory for both treatment groups (overall 30-day mortality: 1.1%). The mean index hospitalisation length was markedly longer in the SAVR group (8.6±8.3 days) as compared to the TAVI group (1.8±3.2 days). CONCLUSIONS: TAVI was routinely performed in low surgical risk patients in 2021 with two-thirds of all severe AS patients undergoing TAVI, thereby applying the latest European guidelines. A dedicated Heart Team meeting, including CT evaluation for all AS patients, is needed to make individualised management decisions in this new era of aortic valve interventions.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Heart , Hospitalization , Patients , Aortic Valve Stenosis/surgery
3.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38079535

ABSTRACT

AIMS: Guidelines recommend opportunistic screening for atrial fibrillation (AF), using a 30 s single-lead electrocardiogram (ECG) recorded by a wearable device. Since many patients have paroxysmal AF, identification of patients at high risk presenting with sinus rhythm (SR) may increase the yield of subsequent long-term cardiac monitoring. The aim is to evaluate an AI-algorithm trained on 10 s single-lead ECG with or without risk factors to predict AF. METHODS AND RESULTS: This retrospective study used 13 479 ECGs from AF patients in SR around the time of diagnosis and 53 916 age- and sex-matched control ECGs, augmented with 17 risk factors extracted from electronic health records. AI models were trained and compared using 1- or 12-lead ECGs, with or without risk factors. Model bias was evaluated by age- and sex-stratification of results. Random forest models identified the most relevant risk factors. The single-lead model achieved an area under the curve of 0.74, which increased to 0.76 by adding six risk factors (95% confidence interval: 0.74-0.79). This model matched the performance of a 12-lead model. Results are stable for both sexes, over ages ranging from 40 to 90 years. Out of 17 clinical variables, 6 were sufficient for optimal accuracy of the model: hypertension, heart failure, valvular disease, history of myocardial infarction, age, and sex. CONCLUSION: An AI model using a single-lead SR ECG and six risk factors can identify patients with concurrent AF with similar accuracy as a 12-lead ECG-AI model. An age- and sex-matched data set leads to an unbiased model with consistent predictions across age groups.


Subject(s)
Atrial Fibrillation , Male , Female , Humans , Atrial Fibrillation/diagnosis , Artificial Intelligence , Retrospective Studies , Electrocardiography/methods , Risk Factors
4.
Clin Res Cardiol ; 113(1): 86-93, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37391628

ABSTRACT

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic valve stenosis in elderly patients, but there is uncertainty on their long-term effectiveness. We aimed to assess the long-term outcome of patients undergoing TAVI with the Portico valve. METHODS: We retrospectively collected the data on patients in whom TAVI with Portico was attempted from 7 high-volume centres. Only patients theoretically eligible for 3 or more years of follow-up were included. Clinical outcomes, including death, stroke, myocardial infarction, reintervention for valve degeneration and hemodynamic valve performance were systematically assessed. RESULTS: A total of 803 patients were included, with 504 (62.8%) women, mean age of 82 years, median EuroSCORE II of 3.1%, and 386 (48.1%) subjects at low/moderate risk. The median follow-up was 3.0 years (3.0; 4.0). The composite of death, stroke, myocardial infarction, and reintervention for valve degeneration occurred in 37.5% (95% confidence interval: 34.1-40.9%), with all-cause death in 35.1% (31.8-38.4%), stroke in 3.4% (1.3-3.4%), myocardial infarction in 1.0% (0.3-1.5%), and reintervention for valve degeneration in 1.1% (0.6-2.1%). The mean aortic valve gradient at follow-up was 8.1 ± 4.6 mmHg, and at least moderate aortic regurgitation was present in 9.1% (6.7-12.3%). Independent predictors of major adverse events or death were: peripheral artery disease, chronic obstructive pulmonary disease, estimated glomerular filtration rate, atrial fibrillation, prior pacemaker implantation, EuroSCORE II, and reduced left ventricular ejection fraction (all p < 0.05). CONCLUSIONS: Portico use is associated with favorable long-term clinical outcomes. Clinical outcomes were largely impacted by baseline risk factors and surgical risk.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Myocardial Infarction , Stroke , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Retrospective Studies , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Aortic Valve Stenosis/surgery , Stroke/etiology
5.
Cardiovasc Revasc Med ; 60: 82-86, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37714726

ABSTRACT

BACKGROUND: The percutaneous treatment of calcified coronary lesions remains challenging and is associated with worse clinical outcomes. In addition, coronary artery calcification is associated with more frequent peri-procedural myocardial infarction. STUDY DESIGN AND OBJECTIVES: The ShOckwave ballooN or Atherectomy with Rotablation in calcified coronary artery lesions (SONAR) study is an investigator-initiated, prospective, randomized, international, multicenter, open label trial (NCT05208749) comparing a lesion preparation strategy with either shockwave intravascular lithotripsy (IVL) or rotational atherectomy (RA) before drug-eluting stent implantation in 170 patients with moderate to severe calcified coronary lesions. The primary endpoint is difference in the rate of peri-procedural myocardial infarction. Key secondary endpoints include rate of peri-procedural microvascular dysfunction, peri-procedural myocardial injury, descriptive study of IMR measurements in calcified lesions, technical and procedural success, interaction between OCT calcium score and primary endpoint, 30-day and 1-year major adverse clinical events. CONCLUSIONS: The SONAR trial is the first randomized controlled trial comparing the incidence of peri-procedural myocardial infarction between 2 contemporary calcium modification strategies (Shockwave IVL and RA) in patients with calcified coronary artery lesions. Furthermore, for the first time, the incidence of peri-procedural microvascular dysfunction after Shockwave IVL and RA will be evaluated and compared.


Subject(s)
Atherectomy, Coronary , Coronary Artery Disease , Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Vascular Calcification , Humans , Atherectomy, Coronary/adverse effects , Prospective Studies , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Calcium , Coronary Angiography , Treatment Outcome , Vascular Calcification/diagnostic imaging , Vascular Calcification/therapy , Vascular Calcification/etiology , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/etiology , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Atherectomy
6.
Front Cardiovasc Med ; 10: 1227217, 2023.
Article in English | MEDLINE | ID: mdl-37645516

ABSTRACT

Background: A steep rise in the use of transcatheter aortic valve implantation (TAVI) for the management of symptomatic severe aortic stenosis occurred. Minimalist TAVI procedures and streamlined patient pathways within experienced Heart Valve Centres are designed to overcome the challenges of ever-increasing procedural volume. Aims: The 2022 European TAVI Pathway Survey aims to describe contemporary TAVI practice across Europe. Materials and methods: Between October and December 2022, TAVI operators from 32 European countries were invited to complete an online questionnaire regarding their current practice. Results: Responses were available from 147 TAVI centres in 26 countries. In 2021, the participating centres performed a total number of 27,223 TAVI procedures, with a mean of 185 TAVI cases per centre (median 138; IQR 77-194). Treatment strategies are usually (87%) discussed at a dedicated Heart Team meeting. Transfemoral TAVI is performed with local anaesthesia only (33%), with associated conscious sedation (60%), or under general anaesthesia (7%). Primary vascular access is percutaneous transfemoral (99%) with secondary radial access (52%). After uncomplicated TAVI, patients are transferred to a high-, medium-, or low-care unit in 28%, 52%, and 20% of cases, respectively. Time to discharge is day 1 (12%), day 2 (31%), day 3 (29%), or day 4 or more (28%). Conclusion: Reported adoption of minimalist TAVI techniques is common among European TAVI centres, but rates of next-day discharge remain low. This survey highlights the significant progress made in refining TAVI treatment and pathways in recent years and identifies possible areas for further improvement.

7.
Eur Heart J Case Rep ; 7(7): ytad310, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37501711

ABSTRACT

Background: The transfemoral (TF) approach drives most of the advantages of transcatheter aortic valve implantation (TAVI) over surgical aortic valve replacement. Alternative accesses for TAVI are associated with higher complication rates, but are still considered in ∼5% of cases due to peripheral arterial disease (PAD). Percutaneous transluminal angioplasty can still allow TF-TAVI in selected cases with severe calcific PAD; however, ancillary techniques for calcium management are often needed. Case Summary: Orbital atherectomy was selected to facilitate TF-TAVI in two patients with different degrees and aspects of calcific PAD. Pre-procedural computed tomography analysis was key to choose the most appropriate technique for calcium management. We describe our experience with a step-by-step procedural approach to orbital atherectomy-assisted TF-TAVI. Discussion: PAD is not uncommon in patients affected by severe symptomatic aortic valve stenosis. Orbital atherectomy can still allow TF-TAVI in selected cases with severe calcific PAD. A meticulous patient selection and a standardized, step-wise procedural execution are mandatory to optimize outcomes.

8.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Article in English | MEDLINE | ID: mdl-37480891

ABSTRACT

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Subject(s)
Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Incidence , Bundle-Branch Block , Prognosis , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
9.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Article in English | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

ABSTRACT

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Subject(s)
Pacemaker, Artificial
10.
Biomedicines ; 11(4)2023 Apr 01.
Article in English | MEDLINE | ID: mdl-37189684

ABSTRACT

Circulating biomarkers reflecting cardiac inflammation are needed to improve the diagnostics and guide the treatment of heart failure patients. The cardiac production and shedding of the transmembrane proteoglycan syndecan-4 is upregulated by innate immunity signaling pathways. Here, we investigated the potential of syndecan-4 as a blood biomarker of cardiac inflammation. Serum syndecan-4 was measured in patients with (i) non-ischemic, non-valvular dilated cardiomyopathy (DCM), with (n = 71) or without (n = 318) chronic inflammation; (ii) acute myocarditis (n = 15), acute pericarditis (n = 3) or acute perimyocarditis (23) and (iii) acute myocardial infarction (MI) at day 0, 3 and 30 (n = 119). Syndecan-4 was investigated in cultured cardiac myocytes and fibroblasts (n = 6-12) treated with the pro-inflammatory cytokines interleukin (IL)-1ß and its inhibitor IL-1 receptor antagonist (IL-1Ra), or tumor necrosis factor (TNF)α and its specific inhibitor infliximab, an antibody used in treatment of autoimmune diseases. The levels of serum syndecan-4 were comparable in all subgroups of patients with chronic or acute cardiomyopathy, independent of inflammation. Post-MI, syndecan-4 levels were increased at day 3 and 30 vs. day 0. IL-1Ra attenuated IL-1ß-induced syndecan-4 production and shedding in vitro, while infliximab had no effect. In conclusion, syndecan-4 shedding from cardiac myocytes and fibroblasts was attenuated by immunomodulatory therapy. Although its circulating levels were increased post-MI, syndecan-4 did not reflect cardiac inflammatory status in patients with heart disease.

11.
JACC Cardiovasc Interv ; 16(4): 396-411, 2023 02 27.
Article in English | MEDLINE | ID: mdl-36858659

ABSTRACT

BACKGROUND: The optimal access route in patients with severe peripheral artery disease (PAD) undergoing transcatheter aortic valve replacement (TAVR) remains undetermined. OBJECTIVES: This study sought to compare clinical outcomes with transfemoral access (TFA), transthoracic access (TTA), and nonthoracic transalternative access (TAA) in TAVR patients with severe PAD. METHODS: Patients with PAD and hostile femoral access (TFA impossible, or possible only after percutaneous treatment) undergoing TAVR at 28 international centers were included in this registry. The primary endpoint was the propensity-adjusted risk of 30-day major adverse events (MAE) defined as the composite of all-cause mortality, stroke/transient ischemic attack (TIA), or main access site-related Valve Academic Research Consortium 3 major vascular complications. Outcomes were also stratified according to the severity of PAD using a novel risk score (Hostile score). RESULTS: Among the 1,707 patients included in the registry, 518 (30.3%) underwent TAVR with TFA after percutaneous treatment, 642 (37.6%) with TTA, and 547 (32.0%) with TAA (mostly transaxillary). Compared with TTA, both TFA (adjusted HR: 0.58; 95% CI: 0.45-0.75) and TAA (adjusted HR: 0.60; 95% CI: 0.47-0.78) were associated with lower 30-day rates of MAE, driven by fewer access site-related complications. Composite risks at 1 year were also lower with TFA and TAA compared with TTA. TFA compared with TAA was associated with lower 1-year risk of stroke/TIA (adjusted HR: 0.49; 95% CI: 0.24-0.98), a finding confined to patients with low Hostile scores (Pinteraction = 0.049). CONCLUSIONS: Among patients with PAD undergoing TAVR, both TFA and TAA were associated with lower 30-day and 1-year rates of MAE compared with TTA, but 1-year stroke/TIA rates were higher with TAA compared with TFA.


Subject(s)
Ischemic Attack, Transient , Peripheral Arterial Disease , Stroke , Transcatheter Aortic Valve Replacement , Humans , Treatment Outcome , Registries
12.
Circ Cardiovasc Interv ; 16(1): e012538, 2023 01.
Article in English | MEDLINE | ID: mdl-36649387

ABSTRACT

BACKGROUND: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Time Factors , Treatment Outcome , Registries , Prosthesis Design , Risk Factors
15.
EuroIntervention ; 18(12): 977-986, 2023 Jan 23.
Article in English | MEDLINE | ID: mdl-36093795

ABSTRACT

BACKGROUND: The ACURATE neo2 (NEO2) and Evolut PRO/PRO+ (PRO) bioprostheses are new-generation self-expanding valves developed for transcatheter aortic valve replacement (TAVR). AIMS: We sought to compare the performance of the ACURATE neo2 and Evolut PRO/PRO+ devices. METHODS: The NEOPRO-2 registry retrospectively included patients who underwent TAVR for severe aortic stenosis with either the NEO2 or PRO devices between August 2017 and December 2021 at 20 centres. In-hospital and 30-day Valve Academic Research Consortium (VARC)-3 defined outcomes were evaluated. Propensity score (PS) matching and binary logistic regression were performed to adjust the treatment effect for PS quintiles. A subgroup analysis assessed the impact of aortic valve calcification. RESULTS: A total of 2,175 patients (NEO2: n=763; PRO: n=1,412) were included. The mean age was 82±6.2 years and the mean Society of Thoracic Surgeons score was 4.2%. Periprocedural complications were low, and both groups achieved high rates of technical success (93.1% vs 94.1%; p=0.361) and predischarge intended valve performance (96.0% vs 94.1%; p=0.056), both in the unmatched and matched analysis (452 pairs). Device success at 30 days was comparable (84.3% vs 83.6%; p=0.688), regardless of aortic valve calcification severity (p>0.05 for interaction). A suggestion for higher VARC-3 early safety in the NEO2 group was mainly driven by reduced rates of new permanent pacemaker implantation (7.7% vs 15.6%; p<0.001). CONCLUSIONS: This retrospective analysis reports a similar short-term performance of the ACURATE neo2 platform compared with the new-generation Evolut PRO/PRO+ devices. Randomised studies are needed to confirm our exploratory findings.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Humans , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Heart Valve Prosthesis/adverse effects , Postoperative Complications/etiology , Prosthesis Design , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
16.
Article in English | MEDLINE | ID: mdl-36542648

ABSTRACT

BACKGROUND: Use of a right-left (R-L) cusp overlap view for transcatheter aortic valve replacement (TAVR) with self-expanding valves has recently been proposed aiming to reduce permanent pacemaker implantation (PPMI). An objective, data-driven explanation for this observation is missing. AIMS: To assess the impact of different implantation techniques on the risk of PPMI following TAVR with the Portico/NavitorTM transcatheter heart valve (THV; Abbott). METHODS: A TAVR-population treated with Portico/NavitorTM had the THV implanted in a right versus left anterior oblique (RAO/LAO) fluoroscopic view with no parallax in the delivery system. The impact of these different implantation views on the spatial relationship between THV and native aortic annulus and the risk of conduction disturbances and PPMI after TAVR was studied. RESULTS: A total of 366 matched TAVR patients were studied: 183 in the RAO group and 183 in the LAO group. The degree of aortic annulus plane tilt was significantly smaller in the RAO versus LAO group (median: 0° vs. 23°, p < 0.001), with no plane tilt in 105 out of 183 cases (57.3%) in the RAO group. At 30 days after TAVR, the overall PPMI and guideline-directed PPMI rates were 12.6% versus 18.0% (p = 0.15) and 8.2% versus 15.3% (p = 0.04) in the RAO versus LAO group, respectively. CONCLUSIONS: Use of a R-L cusp overlap (RAO-caudal) view for implantation of the Portico/NavitorTM valve results in less tilt of the native aortic annulus plane and a clear trend toward a lower 30-day PPMI rate as compared to TAVR using the conventional LAO implantation view.

19.
Catheter Cardiovasc Interv ; 100(5): 795-800, 2022 11.
Article in English | MEDLINE | ID: mdl-35880854

ABSTRACT

OBJECTIVES: This study aimed to assess the rate of difficult interatrial septum (IAS) crossing with the intracardiac echocardiography (ICE) probe during percutaneous left atrial appendage (LAA) closure and to identify techniques that facilitate IAS crossing with the ICE probe. BACKGROUND: Percutaneous LAA closure is increasingly performed by ICE guidance. Although such an approach omits the need for general anesthesia, crossing of the IAS with the ICE probe may sometimes be challenging. METHODS: All consecutive patients that underwent ICE-guided percutaneous LAA closure with an Amplatzer Amulet (Abbott) or WatchmanFLX (Boston Scientific) at our center in the period 2018-2021 were included. Cases in which IAS crossing with ICE was difficult were identified and techniques used to facilitate IAS crossing were identified and listed. RESULTS: In 17 (5%) out of 354 cases, IAS crossing with the ICE probe was difficult and required use of additional techniques. Ultimately, IAS crossing was also successful in these 17 cases by using one of three possible facilitation techniques: the probing technique (12 cases), the double-wire technique (3 cases), and the snaring technique (2 cases). In one case, the double-wire technique was converted to the snaring technique, as crossing of the ICE probe remained challenging despite the use of two stiff guidewires. CONCLUSION: Crossing of the IAS with the ICE probe can be challenging in 5% of ICE-guided percutaneous LAA closure procedures. Operators should be aware of possible facilitation techniques in challenging cases, as these show to be safe and effective.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Humans , Atrial Appendage/diagnostic imaging , Echocardiography, Transesophageal , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/therapy , Ultrasonography, Interventional/methods , Treatment Outcome
20.
EuroIntervention ; 18(10): 804-811, 2022 Nov 18.
Article in English | MEDLINE | ID: mdl-35678222

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) with the ACURATE neo device has been associated with a non-negligible incidence of paravalvular aortic regurgitation (AR). The new-generation ACURATE neo2 has been designed to mitigate this limitation. AIMS: The aim of the study was to compare TAVR with the ACURATE neo and neo2 devices. METHODS: The NEOPRO and NEOPRO-2 registries retrospectively included patients undergoing transfemoral TAVR with self-expanding valves at 24 and 20 centres, respectively. Patients receiving the ACURATE neo and neo2 devices (from January 2012 to December 2021) were included in this study. Predischarge and 30-day VARC-3 defined outcomes were evaluated. The primary endpoint was predischarge moderate or severe paravalvular AR. Subgroup analyses per degree of aortic valve calcification were performed. RESULTS: A total of 2,026 patients (neo: 1,263, neo2: 763) were included. Predischarge moderate or severe paravalvular AR was less frequent for the neo2 group (2% vs 5%; p<0.001), resulting in higher VARC-3 intended valve performance (96% vs 90%; p<0.001). Furthermore, more patients receiving the neo2 had none/trace paravalvular AR (59% vs 38%; p<0.001). The reduction in paravalvular AR with neo2 was mainly observed with heavy aortic valve calcification. New pacemaker implantation and VARC-3 technical and device success rates were similar between the 2 groups; there were more frequent vascular and bleeding complications for the neo device. Similar 1-year survival was detected after TAVR (neo2: 90% vs neo: 87%; p=0.14). CONCLUSIONS: TAVR with the ACURATE neo2 device was associated with a lower prevalence of moderate or severe paravalvular AR and more patients with none/trace paravalvular AR. This difference was particularly evident with heavy aortic valve calcification.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Heart Valve Prosthesis/adverse effects , Retrospective Studies , Prosthesis Design , Treatment Outcome , Time Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Hemodynamics
SELECTION OF CITATIONS
SEARCH DETAIL
...