Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Oral Investig ; 27(11): 6413-6420, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37704914

ABSTRACT

AIM: To assess the observed volume of filled C-shaped root canals from different CBCT and micro-CT having nano-CT as a reference. MATERIALS AND METHODS: Twelve extracted mandibular molars with C-shaped root canals were endodontically treated using Reciproc Blue R25 (VDW GMBH, Munich, Germany) in a reciprocating system and filled with gutta-percha (Dentsply Maillefer) and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany). CBCT scans were performed using 3 units-3D Accuitomo 170 (J. Morita, Kyoto, Japan), ProMax 3D Max (Planmeca, Helsinki, Finland), and NewTom VGi EVO (Cefla QR, Verona, Italy)-at two resolution modes: standard and high. Micro-CT and nano-CT scans were also obtained. The volume of all filled C-shaped root canals was obtained using CTAn software (Bruker, Kontich, Belgium), and the blooming artifact, in relation to nano-CT volume, was calculated. The data were evaluated by the Bland-Altman plots and ANOVA two-way for repeated measures (α = 0.05). RESULTS: All CBCT units and micro-CT showed significantly larger observed volume of root canal filling when compared to nano-CT. The blooming artifact of root canal filling in standard resolution was significantly larger than that in high resolution (p < 0.05) in all CBCT units. CONCLUSIONS: Endodontic filling material with AH Plus sealer causes blooming artifacts in CBCT units and micro-CT. CLINICAL RELEVANCE: Considering the anatomical complexity of C-shaped root canals and the challenges associated with endodontic treatment, CBCT is frequently recommended for follow-up evaluations. However, the presence of endodontic filling material can result in blooming artifacts that may potentially impact the accurate diagnosis of endodontic complications.


Subject(s)
Root Canal Filling Materials , Dental Pulp Cavity , X-Ray Microtomography , Root Canal Preparation , Retreatment , Gutta-Percha , Root Canal Obturation , Cone-Beam Computed Tomography
2.
Dentomaxillofac Radiol ; 50(4): 20200450, 2021 May 01.
Article in English | MEDLINE | ID: mdl-33237809

ABSTRACT

OBJECTIVES: To evaluate the influence of exomass-related metal artefacts on the detection of simulated vertical root fracture (VRF) in cone-beam computed tomography (CBCT). METHODS: 20 teeth were endodontically instrumented and VRF was induced in half of them. All teeth were individually placed in an empty socket of a human mandible. Metallic materials were differently arranged in the exomass [zone outside of the field of view (FOV) but between the X-ray source and the receptor] and/or endomass (zone inside of the FOV), and CBCT scans were obtained. Four radiologists evaluated the presence of VRF using a 5-point scale. Sensitivity, specificity, and area under the receiver operating curve (AUC) were compared using ANOVA. Also, the tooth of interest was replaced with a tube filled with a radiopaque solution and all CBCT scans were repeated to analyse the data objectively. Mean grey and noise values were obtained from the tube and compared using ANOVA followed by Tukey's test (α = 0.05). RESULTS: Mean grey values were significantly lower and noise was significantly higher when metallic materials were present in the endomass or both the exomass and endomass. Sensitivity, specificity, and AUC were not influenced by the artefacts from the metallic materials irrespective of the arrangement condition. CONCLUSIONS: Exomass-related metal artefacts did not influence the diagnosis of simulated VRF in CBCT.


Subject(s)
Cone-Beam Computed Tomography , Tooth Fractures , Artifacts , Humans , Metals , Rotation , Tooth Fractures/diagnostic imaging , Tooth Root/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL