Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
J 3D Print Med ; 6(1): 13-23, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35211330

ABSTRACT

3D models have been used as an asset in many clinical applications and a variety of disciplines, and yet the available literature studying the use of 3D models in communication is limited. This scoping review has been conducted to draw conclusions on the current evidence and learn from previous studies, using this knowledge to inform future work. Our search strategy revealed 269 papers, 19 of which were selected for final inclusion and analysis. When assessing the use of 3D models in doctor-patient communication, there is a need for larger studies and studies including a long-term follow up. Furthermore, there are forms of communication that are yet to be researched and provide a niche that may be beneficial to explore.

2.
Front Cardiovasc Med ; 8: 642011, 2021.
Article in English | MEDLINE | ID: mdl-34150862

ABSTRACT

This is a 7-years single institution study on low-cost cardiac three-dimensional (3D) printing based on the use of free open-source programs and affordable printers and materials. The process of 3D printing is based on several steps (image acquisition, segmentation, mesh optimization, slicing, and three-dimensional printing). The necessary technology and the processes to set up an affordable three-dimensional printing laboratory are hereby described in detail. Their impact on surgical and interventional planning, medical training, communication with patients and relatives, patients' perception on care, and new cardiac device development was analyzed. A total of 138 low-cost heart models were designed and printed from 2013 to 2020. All of them were from different congenital heart disease patients. The average time for segmentation and design of the hearts was 136 min; the average time for printing and cleaning the models was 13.5 h. The average production cost of the models was €85.7 per model. This is the most extensive series of 3D printed cardiac models published to date. In this study, the possibility of manufacturing three-dimensional printed heart models in a low-cost facility fulfilling the highest requirements from a technical and clinical point of view is demonstrated.

3.
J Magn Reson Imaging ; 53(5): 1446-1457, 2021 05.
Article in English | MEDLINE | ID: mdl-33155758

ABSTRACT

BACKGROUND: Improvements in outcomes for patients with congenital heart disease (CHD) have increased the need for diagnostic and interventional procedures. Cumulative radiation risk is a growing concern. MRI-guided interventions are a promising ionizing radiation-free, alternative approach. PURPOSE: To assess the feasibility of MRI-guided catheterization in young patients with CHD using advanced visualization passive tracking techniques. STUDY TYPE: Prospective. POPULATION: A total of 30 patients with CHD referred for MRI-guided catheterization and pulmonary vascular resistance analysis (median age/weight: 4 years / 15 kg). FIELD STRENGTH/SEQUENCE: 1.5T; partially saturated (pSAT) real-time single-shot balanced steady-state free-precession (bSSFP) sequence. ASSESSMENT: Images were visualized by a single viewer on the scanner console (interactive mode) or using a commercially available advanced visualization platform (iSuite, Philips). Image quality for anatomy and catheter visualization was evaluated by three cardiologists with >5 years' experience in MRI-catheterization using a 1-5 scale (1, poor, 5, excellent). Catheter balloon signal-to-noise ratio (SNR), blood and myocardium SNR, catheter balloon/blood contrast-to-noise ratio (CNR), balloon/myocardium CNR, and blood/myocardium CNR were measured. Procedure findings, feasibility, and adverse events were recorded. A fraction of time in which the catheter was visible was compared between iSuite and the interactive mode. STATISTICAL TESTS: T-test for numerical variables. Wilcoxon signed rank test for categorical variables. RESULTS: Nine patients had right heart catheterization, 11 had both left and right heart catheterization, and 10 had single ventricle circulation. Nine patients underwent solely MRI-guided catheterization. The mean score for anatomical visualization and contrast between balloon tip and soft tissue was 3.9 ± 0.9 and 4.5 ± 0.7, respectively. iSuite provided a significant improvement in the time during which the balloon was visible in relation to interactive imaging mode (66 ± 17% vs. 46 ± 14%, P < 0.05). DATA CONCLUSION: MRI-guided catheterizations were carried out safely and is feasible in children and adults with CHD. The pSAT sequence offered robust and simultaneous high contrast visualization of the catheter and cardiac anatomy. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 1.


Subject(s)
Heart Defects, Congenital , Magnetic Resonance Imaging, Interventional , Adult , Cardiac Catheterization , Child , Child, Preschool , Heart Defects, Congenital/diagnostic imaging , Humans , Magnetic Resonance Imaging , Prospective Studies
5.
Int J Cardiovasc Imaging ; 35(11): 2067-2076, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31203535

ABSTRACT

The use of 3D printed models of the right ventricular outflow tract (RVOT) for surgical and interventional planning is growing and often requires image segmentation of cardiac magnetic resonance (CMR) images. Segmentation results may vary based on contrast, image sequence, signal threshold chosen by the operator, and manual post-processing. The purpose of this study was to determine potential biases and post-processing errors in image segmentation to enable informed decisions. Models of the RVOT and pulmonary arteries from twelve patients who had contrast enhanced CMR angiography with gadopentetate dimeglumine (GPD), gadofosveset trisodium (GFT), and a post-GFT inversion-recovery (IR) whole heart sequence were segmented, trimmed, and aligned by three operators. Geometric agreement and minimal RVOT diameters were compared between sequences and operators. To determine the contribution of threshold, interoperator variability was compared between models created by the same two operators using the same versus different thresholds. Geometric agreement by Dice between objects was high (intraoperator: 0.89-0.95; interoperator: 0.95-0.97), without differences between sequences. Minimal RVOT diameters differed on average by - 1.9 to - 1.3 mm (intraoperator) and by 0.4 to 1.4 mm (interoperator). The contribution of threshold to interoperator geometric agreement was not significant (same threshold: 0.96 ± 0.06, different threshold: 0.93 ± 0.05; p = 0.181), but minimal RVOT diameters were more variable with different versus constant thresholds (- 9.12% vs. 2.42%; p < 0.05). Thresholding does not significantly change interoperator variability for geometric agreement, but does for minimal RVOT diameter. Minimal RVOT diameters showed clinically relevant variation within and between operators.


Subject(s)
Contrast Media/administration & dosage , Gadolinium DTPA/administration & dosage , Gadolinium/administration & dosage , Heart Defects, Congenital/diagnostic imaging , Heart Ventricles/diagnostic imaging , Imaging, Three-Dimensional , Magnetic Resonance Angiography , Models, Cardiovascular , Organometallic Compounds/administration & dosage , Patient-Specific Modeling , Pulmonary Artery/diagnostic imaging , Heart Defects, Congenital/physiopathology , Heart Ventricles/physiopathology , Humans , Observer Variation , Predictive Value of Tests , Pulmonary Artery/physiopathology , Reproducibility of Results
6.
J Cardiovasc Magn Reson ; 21(1): 13, 2019 02 25.
Article in English | MEDLINE | ID: mdl-30798789

ABSTRACT

AIMS: To investigate the use of respiratory motion compensation using image-based navigation (iNAV) with constant respiratory efficiency using single end-expiratory thresholding (CRUISE) for coronary magnetic resonance angiography (CMRA), and compare it to the conventional diaphragmatic navigator (dNAV) in paediatric patients with congenital or suspected heart disease. METHODS: iNAV allowed direct tracking of the respiratory heart motion and was generated using balanced steady state free precession startup echoes. Respiratory gating was achieved using CRUISE with a fixed 50% efficiency. Whole-heart CMRA was acquired with 1.3 mm isotropic resolution. For comparison, CMRA with identical imaging parameters were acquired using dNAV. Scan time, visualization of coronary artery origins and mid-course, imaging quality and sharpness was compared between the two sequences. RESULTS: Forty patients (13 females; median weight: 44 kg; median age: 12.6, range: 3 months-17 years) were enrolled. 25 scans were performed in awake patients. A contrast agent was used in 22 patients. The scan time was significantly reduced using iNAV for awake patients (iNAV 7:48 ± 1:26 vs dNAV 9:48 ± 3:11, P = 0.01) but not for patients under general anaesthesia (iNAV = 6:55 ± 1:50 versus dNAV = 6:32 ± 2:16; P = 0.32). In 98% of the cases, iNAV image quality had an equal or higher score than dNAV. The visual score analysis showed a clear difference, favouring iNAV (P = 0.002). The right coronary artery and the left anterior descending vessel sharpness was significantly improved (iNAV: 56.8% ± 10.1% vs dNAV: 53.7% ± 9.9%, P < 0.002 and iNAV: 55.8% ± 8.6% vs dNAV: 53% ± 9.2%, P = 0.001, respectively). CONCLUSION: iNAV allows for a higher success-rate and clearer depiction of the mid-course of coronary arteries in paediatric patients. Its acquisition time is shorter in awake patients and image quality score is equal or superior to the conventional method in most cases.


Subject(s)
Coronary Vessels/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Magnetic Resonance Angiography , Magnetic Resonance Imaging, Cine , Respiration , Adolescent , Artifacts , Child , Child, Preschool , Contrast Media/administration & dosage , Coronary Vessels/physiopathology , Female , Heart Defects, Congenital/physiopathology , Humans , Infant , Male , Meglumine/administration & dosage , Organometallic Compounds/administration & dosage , Predictive Value of Tests , Reproducibility of Results , Time Factors , Workflow
8.
EuroIntervention ; 14(8): 868-876, 2018 Oct 20.
Article in English | MEDLINE | ID: mdl-30012542

ABSTRACT

AIMS: Superior sinus venosus atrial septal defect (SVASD) is commonly associated with partial anomalous pulmonary venous drainage (PAPVD). We aimed to describe the first series of percutaneous SVASD and PAPVD correction using a two-step simulation for procedural planning. METHODS AND RESULTS: Patients with SVASD and right PAPVD with a clinical indication for correction were selected. They underwent an ex vivo procedural simulation on a 3D-printed model followed by an in vivo simulation using balloon inflation in the targeted stent landing zone. The percutaneous procedure consisted in deploying a 10-zig custom-made covered stent in the SVC-RA junction. Five patients were referred for preprocedural evaluation and were deemed suitable for percutaneous correction. The procedure was successful in all patients with no residual interatrial shunt and successful redirection of the pulmonary venous drainage to the left atrium. At a median clinical follow-up of 8.1 months (2.6-19.8), no adverse events were noted, and all patients showed clinical improvement. During follow-up, transthoracic echocardiography and multidetector cardiac tomography in four patients or invasive angiography in one patient demonstrated a patent SVC stent, and no residual SVASD and unobstructed PV drainage in all patients. CONCLUSIONS: In selected patients using a two-stage simulation strategy, percutaneous correction of SVASD with PAPVD is feasible and safe, and led to favourable short-term outcomes.


Subject(s)
Heart Septal Defects, Atrial , Pulmonary Veins , Drainage , Heart Atria , Humans , Vena Cava, Superior
9.
JRSM Cardiovasc Dis ; 7: 2048004018773958, 2018.
Article in English | MEDLINE | ID: mdl-29760913

ABSTRACT

OBJECTIVES: Stent implantation for the treatment of aortic coarctation has become a standard approach for the management of older children and adults. Criteria for optimal stent design and construction remain undefined. This study used computational modelling to compare the performance of two generations of the Cheatham-Platinum stent (NuMED, Hopkinton, NY, USA) deployed in aortic coarctation using finite element analysis. DESIGN: Three-dimensional models of both stents, reverse engineered from microCT scans, were implanted in the aortic model of one representative patient. They were virtually expanded in the vessel with a 16 mm balloon and a pressure of 2 atm. RESULTS: The conventional stent foreshortened to 96.5% of its initial length, whereas the new stent to 99.2% of its initial length. Diameters in 15 slices across the conventional stent were 11.6-15 mm (median 14.2 mm) and slightly higher across the new stent: 10.7-15.3 mm (median 14.5 mm) (p= 0.021). Apposition to the vessel wall was similar: conventional stent 31.1% and new stent 28.6% of total stent area. CONCLUSIONS: The new design Cheatham-Platinum stent showed similar deployment results compared to the conventional design. The new stent design showed slightly higher expansion, using the same delivery balloon. Patient-specific computational models can be used for virtual implantation of new aortic stents and promise to inform subsequent in vivo trials.

11.
J Cardiovasc Magn Reson ; 19(1): 60, 2017 Aug 15.
Article in English | MEDLINE | ID: mdl-28806996

ABSTRACT

BACKGROUND: Cardiac catheterization is a common procedure in patients with congenital heart disease (CHD). Although cardiovascular magnetic resonance imaging (CMR) represents a promising alternative approach to fluoroscopy guidance, simultaneous high contrast visualization of catheter, soft tissue and the blood pool remains challenging. In this study, a novel passive tracking technique is proposed for enhanced positive contrast visualization of gadolinium-filled balloon catheters using partial saturation (pSAT) magnetization preparation. METHODS: The proposed pSAT sequence uses a single shot acquisition with balanced steady-state free precession (bSSFP) readout preceded by a partial saturation pre-pulse. This technique was initially evaluated in five healthy subjects. The pSAT sequence was compared to conventional bSSFP images acquired with (SAT) and without (Non-SAT) saturation pre-pulse. Signal-to-noise ratio (SNR) of the catheter balloon, blood and myocardium and the corresponding contrast-to-noise ratio (CNR) are reported. Subjective assessment of image suitability for CMR-guidance and ideal pSAT angle was performed by three cardiologists. The feasibility of the pSAT sequence is demonstrated in two adult patients undergoing CMR-guided cardiac catheterization. RESULTS: The proposed pSAT approach provided better catheter balloon/blood contrast and catheter balloon/myocardium contrast than conventional Non-SAT sequences. It also resulted in better blood and myocardium SNR than SAT sequences. When averaged over all volunteers, images acquired with a pSAT angle of 20° to 40° enabled simultaneous visualization of the catheter balloon and the cardiovascular anatomy (blood and myocardium) and were found suitable for CMR-guidance in >93% of cases. The pSAT sequence was successfully used in two patients undergoing CMR-guided diagnostic cardiac catheterization. CONCLUSIONS: The proposed pSAT sequence offers real-time, simultaneous, enhanced contrast visualization of the catheter balloon, soft tissues and blood. This technique provides improved passive tracking capabilities during CMR-guided catheterization in patients.


Subject(s)
Cardiac Catheterization/instrumentation , Cardiac Catheters , Contrast Media/administration & dosage , Heart Defects, Congenital/diagnosis , Magnetic Resonance Imaging, Interventional , Meglumine/administration & dosage , Organometallic Compounds/administration & dosage , Adolescent , Adult , Case-Control Studies , Feasibility Studies , Female , Heart Defects, Congenital/physiopathology , Heart Defects, Congenital/therapy , Humans , Image Interpretation, Computer-Assisted , Male , Predictive Value of Tests
12.
EuroIntervention ; 13(9): e1080-e1083, 2017 Oct 13.
Article in English | MEDLINE | ID: mdl-28555593

ABSTRACT

AIMS: Coronary artery fistulae represent one of the most challenging anatomical defects to define accurately. We aimed to investigate the additional benefit conferred by volume rendering of tomographic images and 3D printing for diagnosis and interventional planning. METHODS AND RESULTS: Four cases of coronary fistulae were considered for transcatheter closure. Multidetector computed tomography (three cases) or cardiac magnetic resonance (one case) images were acquired and segmented using Mimics software. Each case was reviewed after incremental consideration of diagnostic resources: two cardiologists reported source and volume-rendered images; device closure was discussed by the interventional cardiology team. All diagnoses and planned management were reviewed after inspection of a 3D model. Using source images alone, both cardiologists correctly described the course and drainage in two out of four cases. Aided by volume rendering, this improved to three out of four cases. Inspection of the 3D printed model prompted the planned interventional approach and device sizing to be altered in two out of four cases. In one out of four cases, the intervention was abandoned after inspection of the 3D printed model. CONCLUSIONS: Diagnosis and management of patients with coronary artery fistulae rely on detailed image analyses. 3D models add value when determining the feasibility of, and the approach to intervention in these cases.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Models, Anatomic , Vascular Fistula/diagnostic imaging , Adult , Aged , Cardiac Imaging Techniques , Child, Preschool , Clinical Decision-Making , Female , Humans , Male , Middle Aged , Printing, Three-Dimensional
13.
Front Pediatr ; 5: 39, 2017.
Article in English | MEDLINE | ID: mdl-28293551

ABSTRACT

INTRODUCTION: Patients with Tetralogy of Fallot (TOF) and pulmonary insufficiency and a dilated right ventricle (RV) may suffer from a reduction in left ventricular (LV) performance. It is not clear whether timely pulmonary valve replacement (PVR) preserves LV mechanics. METHODS: Ten TOF patients who underwent PVR were identified from hospital records, and pre- and postoperative cardiac magnetic resonance images were post-processed with a semi-automatic tissue tracking software. LV circumferential strain, time to peak strain, and torsion were compared before and after PVR. A control group of 10 age-matched normal volunteers was assessed as a comparison. RESULTS: LV circumferential strain did not change before vs. after PVR (basal -18.3 ± 3.7 vs. -20.5 ± 3%, p = 0.082; mid-ventricular -18.4 ± 3.6 vs. -19.1 ± 2%, p = 0.571; apical -22.7 ± 5.2 vs. -22.1 ± 4%; p = 0.703). There was also no difference seen between the baseline strain and normal controls (control basal -18.2 ± 3.3%, p = 0.937; mid -18 ± 3.2%, p = 0.798; apex -24.1 ± 5%, p = 0.552). LV torsion remained unchanged from baseline to post PVR [systolic 2.75 (1.23-9.51) °/cm vs. 2.3 ± 1.2°/cm, p = 0.285; maximum 5.5 ± 3.5°/cm vs. 2.34 (1.37-8.07) °/cm, p = 0.083]. There was no difference in time to measured peak LV circumferential strain before vs. after PVR (basal 0.44 ± 0.1 vs. 0.43 ± 0.05, p = 0.912; mid-ventricular 0.42 ± 0.08 vs. 0.38 ± 0.06, p = 0.186; apical 0.40 ± 0.08 vs. 0.40 ± 0.06, p = 0.995). At the same time, pulmonary regurgitation and RV end-diastolic and end-systolic volume indices decreased and LV end-diastolic volume increased after PVR. RV and LV ejection fractions remained constant. CONCLUSION: PVR allows for favorable remodeling of both ventricular volumes for TOF patients with significant pulmonary regurgitation. In this cohort, LV myocardial functional parameters such as circumferential strain, time to peak strain, and LV torsion were normal at baseline and remain unchanged after PVR.

SELECTION OF CITATIONS
SEARCH DETAIL
...