Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
Med. oral patol. oral cir. bucal (Internet) ; 14(10): 499-505, oct. 2009.
Article in English | IBECS | ID: ibc-77313

ABSTRACT

Introduction: The European Union has established specific directives concerning radiological protection which areobligatory for member States. In addition, all Spanish dental clinics with radiological equipment are required tohave an annual quality control check. Objective: To analyze the effect of new European legislation on dental radiologicalpractice in Spain and to determine whether it has resulted in lower doses being administered to patients.Material and Methods: A total of 10,171 official radiological quality control reports on Spanish dental clinics, covering16 autonomous regions, were studied following the passing of Royal Decree 2071/1995 on quality criteriain radiodiagnostic installations. The reports, compiled by U.T.P.R Asigma S.A., a company authorised by the NuclearSafety Council, cover the years 1996 to 2003, which has enabled us to monitor the evolution of radiologicalprocedures in dental clinics over a seven year period. Results: According to the reports for 2003, 77.3 % of clinicscomplied with EU requirements, using equipment of 70 kVp, 8 mA, 1.5 mm Al filters, with a collimator lengthof 20 cm. However, non-compliance was detected in approximately a third (30.8%) of the equipment inspected:alterations in the kilovoltage used, exposure time, performance of the tubing, dosage, linearity/intensity of currentand acoustic-luminous signal 6.86%. The mean skin dose reached 3.11 mGy for patients who received an x-ray ofan upper molar, representing a decrease of 18% over the seven years studied. Conclusion: there has obviously beena general improvement in the parameters studied, but only 77.3% of the installations complied fully with officialEU regulations concerning dental radiological protection (AU)


Subject(s)
Humans , Dental Clinics/standards , Quality Control , Radiation Protection/standards , Radiation Protection/instrumentation , Spain
2.
Med Oral Patol Oral Cir Bucal ; 14(10): e499-505, 2009 Oct 01.
Article in English | MEDLINE | ID: mdl-19680217

ABSTRACT

INTRODUCTION: The European Union has established specific directives concerning radiological protection which are obligatory for member States. In addition, all Spanish dental clinics with radiological equipment are required to have an annual quality control check. OBJECTIVE: To analyze the effect of new European legislation on dental radiological practice in Spain and to determine whether it has resulted in lower doses being administered to patients. MATERIAL AND METHODS: A total of 10,171 official radiological quality control reports on Spanish dental clinics, covering 16 autonomous regions, were studied following the passing of Royal Decree 2071/1995 on quality criteria in radiodiagnostic installations. The reports, compiled by U.T.P.R Asigma S.A., a company authorised by the Nuclear Safety Council, cover the years 1996 to 2003, which has enabled us to monitor the evolution of radiological procedures in dental clinics over a seven year period. RESULTS: According to the reports for 2003, 77.3 % of clinics complied with EU requirements, using equipment of 70 kVp, 8 mA, 1.5 mm Al filters, with a collimator length of 20 cm. However, non-compliance was detected in approximately a third (30.8%) of the equipment inspected: alterations in the kilovoltage used, exposure time, performance of the tubing, dosage, linearity/intensity of current and acoustic-luminous signal 6.86%. The mean skin dose reached 3.11 mGy for patients who received an x-ray of an upper molar, representing a decrease of 18% over the seven years studied. CONCLUSION: there has obviously been a general improvement in the parameters studied, but only 77.3% of the installations complied fully with official EU regulations concerning dental radiological protection.


Subject(s)
Dental Clinics/standards , Quality Control , Radiation Protection/standards , Humans , Radiation Protection/instrumentation , Spain
SELECTION OF CITATIONS
SEARCH DETAIL
...