1.
BMC Ophthalmol ; 22(1): 498, 2022 Dec 19.
Article in English | MEDLINE | ID: mdl-36536321

ABSTRACT

BACKGROUND: Refraction is one of the key components of a comprehensive eye examination. Auto refractometers that are reliable and affordable can be beneficial, especially in a low-resource community setting. The study aimed to validate the accuracy of a novel wave-front aberrometry-based auto refractometer, Instaref R20 against the open-field system and subjective refraction in an adult population. METHODS: All the participants underwent a comprehensive eye examination including objective refraction, subjective acceptance, anterior and posterior segment evaluation. Refraction was performed without cycloplegia using WAM5500 open-field auto refractometer (OFAR) and Instaref R20, the study device. Agreement between both methods was evaluated using Bland-Altman analysis. The repeatability of the device based on three measurements in a subgroup of 40 adults was assessed. RESULTS: The refractive error was measured in 132 participants (mean age,30.53 ± 9.36 years, 58.3% female). The paired mean difference of the refraction values of the study device against OFAR was - 0.13D for M, - 0.0002D (J0) and - 0.13D (J45) and against subjective refraction (SR) was - 0.09D (M), 0.06 (J0) and 0.03D (J45). The device agreed within +/- 0.50D of OFAR in 78% of eyes for M, 79% for J0 and 78% for J45. The device agreed within +/- 0.5D of SR values for M (84%), J0 (86%) and J45 (89%). CONCLUSION: This study found a good agreement between the measurements obtained with the portable autorefractor against open-field refractometer and SR values. It has a potential application in population-based community vision screening programs for refractive error correction without the need for highly trained personnel.


Subject(s)
Refractive Errors , Vision Screening , Humans , Adult , Female , Young Adult , Male , Prospective Studies , Aberrometry , Reproducibility of Results , Refraction, Ocular , Refractive Errors/diagnosis , Vision Tests , Vision Screening/methods
2.
Clin Ophthalmol ; 16: 4281-4291, 2022.
Article in English | MEDLINE | ID: mdl-36578668

ABSTRACT

Purpose: InstaRef R20 is a handheld, affordable auto refractometer based on Shack Hartmann aberrometry technology. The study's objective was to compare InstaRef R20's performance for identifying refractive error in a paediatric population to that of standard subjective and objective refraction under both pre- and post-cycloplegic conditions. Methods: Refraction was performed using 1) standard clinical procedure consisting of retinoscopy followed by subjective refraction (SR) under pre- and post-cycloplegic conditions and 2) InstaRef R20. Agreement between both methods was evaluated using Bland-Altman analysis. The repeatability of the device based on three measurements in a subgroup of 20 children was assessed. Results: The refractive error was measured in 132 children (mean age 12.31 ± 3 years). The spherical equivalent (M) and cylindrical components (J0 and J45) of the device had clinically acceptable differences (within ±0.50D) and acceptable agreement compared to standard pre- and post-cycloplegic manual retinoscopy and subjective refraction (SR). The device agreed within ± 0.50D of retinoscopy in 67% of eyes for M, 78% for J0 and 80% for J45 and within ± 0.50D of SR in 70% for M and 77% for cylindrical components. Conclusion: InstaRef R20 has an acceptable agreement compared to standard retinoscopy in paediatric population. The measurements from this device can be used as a starting point for subjective acceptance. The device being simple to use, portable, reliable and affordable has the potential for large-scale community-based refractive error detection.

SELECTION OF CITATIONS
SEARCH DETAIL
...